MW 100W Single Output with Battery Charger (UPS Function) D R C = 1 0 0 series W #2 " mea ve all m= Ay Whus 4=/CBC fl @ Features HM Applications * Universal AC input / Full range * Security system * Protections: Short circuit / Overload / Over voltage * Emergency lighting system * Battery low protection / Battery reverse polarity protection * Alarm system by fuse * DC UPS system * Can be installed on DIN rail TS-35/7.5 or 15 * Central monitoring system * Alarm signal for AC OK and Battery low (via relay) * Access systems * Cooling by free air convection * LED indicator for power on * 100% full load burn-in test * 3 years warranty MH Description DRC-100 is a 96W AC/DC DIN rail type security power supply series. In addition to the primary output, there is a charger output with a smaller rated current, enabling the backup power supply application the security access systems require. DRC-100 accepts the universal input between 90VAC and 264VAC, and supplies 13.8VDC and 27.6VDC at output, respectively. With the efficiency up to 89%, it can operate with air convection cooling under -30C through 70C. In addition to the key protection features such as overload protection, over voltage protection, battery low cut off, and battery reverse polarity protection (by fuse), the alarm signal for AC OK and battery low signaling is provided, via relay contact output, to facilitate the system design. Hi Model Encoding DRC - 100/A| Le Output voltage Output wattage Series name File Name:DRC-100-SPEC 2018-12-20MW DRC-1 00 series 100W Single Output with Battery Charger (UPS Function) SPECIFICATION MODEL DRC-100A DRC-100B OUTPUT NUMBER CH1 CH2 CH1 CH2 DC VOLTAGE 13.8V 13.8V 27.6V 27.6V RATED CURRENT 4.5A 2.5A 2.25A 1.25A CURRENT RANGE O~7TA | natn O~3.5A J meee nnne RATED POWER 96.6W 96.6W RIPPLE & NOISE (max.) Note.2}120mMVp-p J rsseeee= 240MVp-p J wetnnne OUTPUT VOLTAGE ADJ.RANGE | CH1:12~ 15V CH1:24 ~ 30V VOLTAGE TOLERANCE Note.3}=61.0% = | netnnenee E1.0% (J neem LINE REGULATION H05% J renee H0.5% (J renee LOAD REGULATION H05% J renee 0.5% =| neem SETUP, RISE TIME Note.4) 2400ms, 50ms/230VAC 2400ms, 50ms/115VAC at full load HOLD UP TIME (Typ.) 50ms/230VAC 10ms/115VAC at full load VOLTAGE RANGE 90 ~ 264VAC 127~370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)] FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY (Typ.) 87% 89% AC CURRENT (Typ.) 1.8A/115VAC 1.1A/230VAC INRUSH CURRENT (Typ.) | COLD START 30A/115VAC 60A/230VAC 105 ~ 150% rated output power OVERLOAD - - - Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION Bee eee CH1 me ~ 18.63V | CH1:28.98 ~ 37.26V Protection type : Shut down o/p voltage, re-power on to recover BATTERY CUT OFF 10+0.5V | 20+1V AC OK Relay contact output, ON : AC OK ; OFF : AC Fail ; max. rating : 30V/1A FUNCTION Relay contact output, OFF : Battery OK ; ON : Battery Low ; max. rating : 30V/1A BATTERY LOW Battery low voltage : < 11V | Battery low voltage : < 22V WORKING TEMP. -30 ~ +70C (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT) STORAGE TEMP., HUMIDITY | -40 ~ +85C, 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/C (0 ~ 50C) on CH1 output VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1, EAC TP TC 004, AS/NZS 60950.1 approved SAFETY g,| WITHSTAND VOLTAGE =| I/P-O/P:3KVAC_I/P-FG:2KVAC O/P-FG:0.5KVAC (Note 5) ISOLATION RESISTANCE | |/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25C/ 70% RH EMC EMISSION Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61204-3, light industry level, criteriaA, EAC TP TC 020; meet EN54-4 for fire detection and fire alarm systems MTBF 410.1Khrs min. MIL-HDBK-217F (25C) OTHERS | DIMENSION 55*90*100mm (W*H*D) PACKING 0.37Kg; 30pes/12.1Kg/0.82CUFT NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature. 2 3 4. 5 . Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. . Tolerance : includes set up tolerance, line regulation and load regulation. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. . The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http:/Awww.meanwell.com) . Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. than 2000m(6500ft). . The ambient temperature derating of 3.5C/1000m with fanless models and of 5C/1000m with fan models for operating altitude higher File Name:DRC-100-SPEC 2018-12-20MW 100W Single Output with Battery Charger (UPS Function) D R C = 1 0 0 series Hi Block Diagram {$$ RL1 5 4 AC OK _| ALARM i o CIRCUIT Po RL2 \ Bat. Low Popo EMI FILTER POWER RECTIFIERS ; oO 4y uP O & 5 & SWITCHING Oo - RECTIFIER FILTER [ vet . at. > vy |__| DETECTION |_| oS)\ 0 Bat.- PWM LI | CIRCUIT CONTROL ry Battery Charger ) Ly 0.V.P. Back up Control Hi Derating Curve Hi Static Characteristics toot 4 100 = 4 | 90} 4 80 , 4 230VAC 80 4 Input only: 607 1 70, 7 1 _ 1 = aol | = Hy J < 2 sop J g 20+ | 4 g 40+ 4 1 | 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 L 1 3000-2000 15-30, 40. 45 50 60,70 (VERTICAL) 90 100 125 135 145 155 165 175 180 200 230 264 AMBIENT TEMPERATURE (C) INPUT VOLTAGE (V) 60Hz File Name:DRC-100-SPEC 2018-12-20100W Single Output with Battery Charger (UPS Function) D R C - 1 0 0 series Hi Suggested Application 1.Backup connection for AC interruption (1) Please refer to Fig1.1 for suggested connection. The power supply charges the battery and provides energy to the load at the same time when AC mains is OK. The battery starts to supply power to the load when AC mains fails. A:12V B:24V Load Battery + Ba Batt | Bat- V+ | V- O00 Fig 1.1 Suggested system connection 2.Alarm signal for AC OK and battery low (1) Alarm signal is sent out through "AC OK" &" Battery Low " pins via relay contact. (2) An external voltage source is required for this function. The maximum applied voltage is 30V and the maximum sink current is 1A. Please refer to Fig 2.2. (3) Table2.1 explains the alarm function built in the power supply (4) AC OK signal (RL1, referring to Block Diagram) will go into hiccup mode when the overload protection is activated. Function Description Output of alarm The signal is "Low" when the power supply turns ON. Low or short AC OK The signal turns to be "High" when the power supply turns OFF. High or open (External applied voltage 30V max.) The signal is "Low" when the voltage of battery is under A:11V, B:22V. Low or short Battery Low The signal is "High" when the voltage of battery is above A:11V, B:22V. High or open (External applied voltage 30V max.) Table 2.1 Explanation of alarm signal AC OK (Battery low) External voltage sorece (V) and resistor (R) (The max. Sink is 1A and 30V) a Fig 2.2 Internal circuit of AC OK (Battery Low), via relay contact File Name:DRC-100-SPEC 2018-12-20100W Single Output with Battery Charger (UPS Function) D R C - 1 0 0 series @ Mechanical Specification Case No.973A Unit:mm (oT) 55 3.81x9 GHGGHSHOHGOHSH) 90 Terminal Pin No. Assignment (TB1): Pin No. | Assignment 1 AC/L or DC+ 2 ACIN or DC- 3 FG + Terminal Pin No. Assignment (TB2): PinNo. | Assignment | Pin No. | Assignment 1,2 -V 6 Bat. - 3,4 +V 7,8 AC OK 5 Bat. + 9,10 Bat. Low Hi Installation Instruction This series fits DIN rail TS35/7.5 or TS35/15. For installation details, please refer to the Instruction manual. bo = a 4 ADMISSIBLE DIN rail:TS35/7.5 OR TS35/15 (For reference only. Not included with unit.) Back View Hi Installation Manual Please refer to : http://www.meanwell.com/manual.html File Name:DRC-100-SPEC 2018-12-20