Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1821R Multi-Conductor - CMR Rated Cable For more Information please call 1-800-Belden1 General Description: 22 AWG stranded (7x30) TC conductor, polyolefin insulation, individually shielded with bonded Beldfoil(R), numbered/color-coded PVC jackets, jackets and shields are bonded so both strip simultaneously, overall black PVC jacket and nylon rip cord. Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material Dia. (mm) 24 22 7x30 TC - Tinned Copper 0.762 Total Number of Conductors: 48 Insulation Insulation Material: Insulation Material Dia. (mm) PO - Polyolefin 1.27 Inner Shield Inner Shield Material: Inner Shield Trade Name Type Inner Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape 100 Inner Shield Drain Wire AWG: AWG 22 Inner Shield Drain Wire Stranding: 7x30 Inner Shield Drain Wire Conductor Material: TC - Tinned Copper Inner Jacket Inner Jacket Material: Inner Jacket Material Nom. Dia. (mm) PVC - Polyvinyl Chloride 3.3782 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 18 19x30 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Outer Jacket Ripcord: Yes Overall Cable Overall Cabling Color Code Chart: Page 1 of 4 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1821R Multi-Conductor - CMR Rated Cable Number Color 1 Brown 2 Red 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White 10 Black 11 Tan 12 Pink 13 Gray/Brown Stripe 14 Gray/Red Stripe 15 Gray/Orange Stripe 16 Gray/Yellow Stripe 17 Gray/Green Stripe 18 Gray/Blue Stripe 19 Gray/Purple Stripe 20 Gray/Gray Stripe 21 Gray/White Stripe 22 Gray/Black Stripe 23 Gray/Tan Stripe 24 Gray/Pink Stripe Overall Nominal Diameter: 24.613 mm Pair Pair Color Code Chart: Color Red and Black Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +60C Bulk Cable Weight: 711.360 Kg/Km Max. Recommended Pulling Tension: 3020.328 N Min. Bend Radius/Minor Axis: 247.650 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMR CEC/C(UL) Specification: CMG EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1666 Riser Page 2 of 4 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1821R Multi-Conductor - CMR Rated Cable CSA Flame Test: FT4 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 50 Nom. Inductance: Inductance (H/m) 0.59058 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 101.711 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 183.736 Nominal Velocity of Propagation: VP (%) 66 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 48.5588 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/km) 38.7158 Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 46.262 Ohm/km Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 1.45 Amps per conductor @ 25C Notes (Overall) Notes: Pair jackets and shields are bonded so both strip simultaneously with automatic stripping equipment. Beldfoil(R) provides high reliability with ease of termination. Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc 1821R 0101000 305 MT 234.962 KG BLACK C 24 #22 FS PR PVC FS PVC 1821R 010500 152 MT 119.522 KG BLACK C 24 #22 FS PR PVC FS PVC Notes: C = CRATE REEL PUT-UP. Revision Number: 1 Revision Date: 10-03-2012 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, Page 3 of 4 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1821R Multi-Conductor - CMR Rated Cable statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 4 of 4 10-30-2013