http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
TEL 3 Series 3 Watt
Input Specifications
Input current (no load) 5 Vin models 40 mA typ.
12 Vin models 20 mA typ.
20 Vin models 15 mA typ.
24 Vin models 5 mA typ.
48 Vin models 3 mA typ.
Input current (full load) 5 Vin models 820 mA typ.
12 Vin models 320 mA typ.
20 Vin models 190 mA typ.
24 Vin models 155 mA typ.
48 Vin models 80 mA typ.
Surge voltage (1 sec. max.) 5 Vin models 11 VDC
12 Vin models 25 VDC
20 Vin models 50 VDC
24 Vin models 50 VDC
48 Vin models 100 VDC
Reverse voltage protection 1.0 A max.
Output Specifications
Voltage set accuracy ±1 %
Regulation – Input variation Vin min. to Vin max. 0.5 % max.
– Load variation 10 – 100 %
single output models 0.5 % max.
dual output models balanced load 1.0 % max.
dual output models unbalanced load 2.0 % max
Ripple and noise (20 MHz Bandwidth) <60 mVpk-pk typ.
Temperature coefficient ±0.02 %/°K
Output current limitation >110 % Iout max., constant current
Short circuit protection indefinite (automatic recovery)
Capacitive load single output models 2000 µF max.
dual output models 1000 µF max.
General Specifications
Temperature ranges – Operating –40°C to +85°C
– Case +95°C max.
– Storage –40°C to +125°C
Load derating 3.3 %/K above 70°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F at +25°C, ground benign) >1 Mio. h
Isolation voltage (60 sec.) – Input/Output/Case 1500 VDC
Isolation capacitance – Input/Output 500 pF typ.
Isolation resistance – Input/Output (500 VDC) >1‘000 M Ohm
Switching frequency 300 kHz typ. (Pulse frequency modulation PFM)
Safety standards UL 60950-1, IEC/EN 60950-1
Compliance up to 60 VDC input voltage
(SELV limit)
Safety approvals CSA File No. 226037
http://directories.csa-international.org
– Certification documents www.tracopower.com/overview/tel3
Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU