26
ASoftline Matt
BSplash resistant (with Arcshield)
VCurved
WSplash resistant (with Arcshield)
PLit window Matt
XTwo color Matt
FFlat lens Gloss (0480 only)
ASoftline lens Matt (0480 only)
as F but with raised profile
RRound
ORDER FORMAT TERMINAL FUNCTION ROCKER BODY BODY ROCKER LAMP VOLTAGE LEGEND &
CODE CODE CODE CODE COLOR COLOR OR ON LIGHT” OPTIONS
C 1353 A L B R 2 602AW
NON-LIT LIT
BBLACK BBLACK AAMBER X’ ROCKER COLOR R,G,W,B
RRED RRED CCLEAR 2125V NEON
WWHITE WWHITE GGREEN 3250V NEON
RRED 712V INCANDESCENT
Standard rocker switch
1350/53 high inrush
Choice of switching
circuits including 3
position
Push-on, solder and
PCB terminals
Choice of bezel styles
Choice of 6 panel cut
outs
We match all major
brands
Matching indicator
Double pole
Splashproof option
Panel cut out A style:
27.2 x 22.3mm
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
28
1550 Series 16(4)A 250Vac T125
UL CSA 16A 250Vac, (2 posn) 250Vac 1hp, 125Vac 1/2hp,
(3 posn) 250 Vac 1/2hp, 125Vac 1/4hp.
UL 85˚C, file E45221, CSA file LR10990.
10A 24Vdc.
1350 series 16(4)A 250Vac T85 1E4 (10,000 Ops.)
1330 series 16(6)A 250Vac T125 5E4 (50,000 Ops.)
150A Inrush to EN61058-1.
UL CSA 20A 250Vac 1hp, 125Vac 1/2hp.
UL 72Vdc 7A, 36Vdc 14A.
UL 85˚C, file E45221, CSA file LR10990.
20A 24Vdc
RoHS compliant
3mm contact gap except if marked µ.
Technical data on pages 4 & 5 (switches), 6 (indicators).
ON - OFF
1550 Standard & 1350 High Inrush Switches150A to EN61058-1 and 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminal 1
TERMINAL
High Inrush
1350
Not W, X or B rocker
C
6.3 x 0.8
H
4.8 x 0.8*
K
2.8 x 0.8*
T
Solder
U
Right angle T Solder (Not DP)
X
PCB 0.8Sq*
*Contact sales for details on 1350 series
9.1
7.0
Ø2.1
9.1
9.1
2.0
1.2
3.2
Ø2.1
9.1
4.0
12 3
45 6
In house test
In house test
Standard
1550
ON - OFF
(momentary ON)
1551
HP rating N/A
ON - OFF
(momentary OFF)
1552
HP rating N/A
ON - OFF
Lit
1353
Not W, X or B rocker
1553
Not W, X or B rocker
ON - ON
1560 µ
ON - ON
(momentary 1 side)
1561 µ
HP rating N/A
2 Circuit
ON - ON
1562 µ
In house tests only
ON - OFF - ON
1570 µ
125V & 250V 1/2 HP
H terminal rated T100 only
ON - OFF - ON
(momentary 1 side)
1571 µ
HP rating N/A
H terminal rated T100 only
ON - OFF - ON
(momentary 2 sides)
1572 µ
HP rating N/A
H terminal rated T100 only
3 position selective
1484 µ
In-house tested to 10(3)A 250Vac
(B rocker only)
3 position selective
(Consult sales for other switch options)
1487 µ
In-house tested to 10(3)A 250Vac
(B rocker only)
Indicator
Technical data on page 6
0480
X terminal N/A
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
Lit (not momentary)
Lit (not momentary)
Lit (not momentary)
Matt or gloss Gloss only
Top view
RoHS
CAT 170 P18-29 1500-6000_2_11-0328:CAT 170 P18-29 1500/6000 23/5/11 08:42 Page 28
602A(W) 730(W) 822(W)
Examples of our range of legend printing
( ) is legend color B-Black, W-White, R-Red
27
Finish Matt is standard
Color Call factory for custom colors.
A full range is available for large orders
Legend printing Select from the examples or
call factory for custom legends
Lamp voltage Call factory for details
Hole plug 1580ABB
Dummy units to fill unused panel holes
Protective cover (designed to IP65)
Snaps on to A, L, Q or T bodies
(add G72 as a suffix). This reduces panel
thickness by 1mm.
Panel sealing washer W42 is available for the
above body sizes but reduces panel
thickness by a further 0.8mm.
Covers are not suitable for momentary types.
For all options call the factory
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
29
A
Gloss or Matt
B
Matt only
L
Matt only
Q
Gloss or matt
R
Matt only
T
Matt only
BODY DIMENSIONS (mm)
Panel cut-out * Bezel
OPTIONS
Panel thickness
A,Q 0.75 to 3.3mm
L,B,T 0.75 to 2.5mm
R0.75 to 3.0mm
* For cut-out details on
momentary switches call sales.
2.0 25.3 Max
9.2
13.2
7.6
Terminal spacing - Poles 10.2 between centres
22.3/22.4
27.2
27.3
22.1/22.2
30.0
30.1
22.3/22.4
28.2
28.3
22.3/22.4
28.2
28.3
23.0/25.4
28.4
28.5
22.1/22.2
30.0
30.1
25.0
30.2
25.0
33.4
R3.5
32.0
25.0
R1.0
25.0
30.2
R1.6
28.9
33.2
30.2
25.0
R1.6
Cut-outs must be punched in the direction of insertion
plunger tube
1350 High inrush, positive break switching
The 1350 series mechanism ensures
contact welds formed at switch-on,
are positively separated by the
plunger tube acting directly on the
step in the moving contact.
step
C1350AL ---
C0480AL ---
C1550XL --- C1553PL --- C1553RA ---
Shown with M614 bezel cover
C0480RA ---
Shown with M614 bezel cover
C1553AA with M616 guard
Cut-out 22.0/22.1 x 29.4/29.5
Guard accepts “A body only
Optional snap-in M441 barrier
CAT 170 P18-29 1500-6000_2_11-0328:CAT 170 P18-29 1500/6000 23/5/11 08:42 Page 29
26
ASoftline Matt
VCurved
PLit window Matt
ORDER FORMAT TERMINAL FUNCTION ROCKER BODY BODY ROCKER LAMP VOLTAGE LEGEND &
CODE CODE CODE CODE COLOR COLOR OR ON LIGHT” OPTIONS
C 1353 A G B R 2 602AW
NON-LIT LIT
BBLACK BBLACK AAMBER X’ ROCKER COLOR R,G,W,B
RRED RRED CCLEAR 2125V NEON
WWHITE WWHITE GGREEN 3250V NEON
RRED 712V INCANDESCENT
With Integral Guard or Cover
Standard rocker switch
1350/53 high inrush
Choice of switching
circuits including 3
position
Push-on, solder and
PCB terminals
Choice of bezel styles
Choice of panel cut outs
Matching indicator
Double pole
Option with integral
guard & cover
Bezel size ‘G’ style
32.0 x 25.0
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
GGUARD
HCOVER
rocker
switches
30
1550 Series 16(4)A 250Vac T125
UL CSA 16A 250Vac, (2 posn) 250Vac 1hp, 125Vac 1/2hp,
(3 posn) 250 Vac 1/2hp, 125Vac 1/4hp.
UL 85˚C, file E45221, CSA file LR10990.
10A 24Vdc.
1350 Series
UL CSA 20A 250Vac 1hp, 125Vac 1/2hp.
UL 72Vdc 7A, 36Vdc 14A.
UL 85˚C, file E45221, CSA file LR10990.
20A 24Vdc
RoHS compliant
3mm contact gap except if marked µ.
Technical data on pages 4 & 5 (switches), 6 (indicators).
ON - OFF
1550 Standard & 1350 High Inrush Switches150A to EN61058-1 and 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminal 1
TERMINAL
High Inrush
1350
C
6.3 x 0.8
H
4.8 x 0.8*
K
2.8 x 0.8*
T
Solder
U
Right angle T Solder (Not DP)
X
PCB 0.8Sq*
*Contact sales for details on 1350 series
9.1
7.0
Ø2.1
9.1
9.1
2.0
1.2
3.2
Ø2.1
9.1
4.0
12 3
45 6
In house test
In house test
Standard
1550
ON - OFF
(momentary ON)
1551
HP rating N/A
ON - OFF
(momentary OFF)
1552
HP rating N/A
ON - OFF
Lit
1353
1553
ON - ON
1560 µ
ON - ON
(momentary 1 side)
1561 µ
HP rating N/A
2 Circuit
ON - ON
1562 µ
In house tests only
ON - OFF - ON
1570 µ
125V & 250V 1/2 HP
H terminal rated T100 only
ON - OFF - ON
(momentary 1 side)
1571 µ
HP rating N/A
H terminal rated T100 only
ON - OFF - ON
(momentary 2 sides)
1572 µ
HP rating N/A
H terminal rated T100 only
Lit (not momentary)
Lit (not momentary)
Lit (not momentary)
Matt or gloss Gloss only
RoHS
CAT 170 P30-31 1500G_11-0328:1500 with Guard DS 23/5/11 08:49 Page 30
602A(W) 730(W) 822(W)
Examples of our range of legend printing
( ) is legend color B-Black, W-White, R-Red
27
Finish Matt is standard
Color Call sales for custom colors.
A full range is available for large orders
Legend printing Select from the examples or
call sales for custom legends
GGuard color must match body color
HClear cover standard with lighted switches.
Black standard with non-lighted
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
GWith Guard
Matt only
HWith Cover
Matt only
BODY DIMENSIONS (mm)
Panel cut-out * Bezel
OPTIONS
Panel thickness
G, H 0.75 to 2.5mm
* For cut-out details on
momentary switches call sales.
2.0 25.3 Max
9.2
13.2
7.6
9.2
Terminal spacing - Poles 10.2 between centres
22.1/22.2
30.0
30.1
22.1/22.2
30.0
30.1
32.0
25.0
25.0
32.0
Cut-outs must be punched in the direction of insertion
plunger tube
1350 High inrush, positive break switching
The 1350 series mechanism ensures
contact welds formed at switch-on,
are positively separated by the
plunger tube acting directly on the
step in the moving contact.
step
C1550AH --- C1553AH ---
31
CAT 170 P30-31 1500G_11-0328:1500 with Guard DS 23/5/11 08:49 Page 31