APTM20SKM04
APTM20SKM04 – Rev 1 May, 2004
APT website
htt
:/
www.advanced
ower.com 2
6
All ratings @ Tj = 25°C unless otherwise specified
Electrical Characteristics
Symbol Characteristic Test Conditions Min Typ Max Unit
BVDSS Drain - Source Breakdown Voltage VGS = 0V, ID = 500µA 200 V
VGS = 0V,VDS = 200V Tj = 25°C 200
IDSS Zero Gate Voltage Drain Current VGS = 0V,VDS = 160V Tj = 125°C 1000
µA
RDS(on) Drain – Source on Resistance VGS = 10V, ID = 186A 4
mW
VGS(th) Gate Threshold Voltage VGS = VDS, ID = 10mA 3 5 V
IGSS Gate – Source Leakage Current VGS = ±30 V, VDS = 0V ±200 nA
Dynamic Characteristics
Symbol Characteristic Test Conditions Min Typ Max Unit
Ciss Input Capacitance 28.9
Coss Output Capacitance 9.32
Crss Reverse Transfer Capacitance
VGS = 0V
VDS = 25V
f = 1MHz 0.58
nF
Qg Total gate Charge 584
Qgs Gate – Source Charge 560
Qgd Gate – Drain Charge
VGS = 10V
VBus = 100V
ID = 372A 212
nC
Td(on) Turn-on Delay Time 32
Tr Rise Time 64
Td(off) Turn-off Delay Time 88
Tf Fall Time
Inductive switching @ 125°C
VGS = 15V
VBus = 133V
ID = 372A
RG = 1.2W 116
ns
Eon Turn-on Switching Energy u 3396
Eoff Turn-off Switching Energy v
Inductive switching @ 25°C
VGS = 15V, VBus = 133V
ID = 372A, RG = 1.2Ω 3716
µJ
Eon Turn-on Switching Energy u 3744
Eoff Turn-off Switching Energy v
Inductive switching @ 125°C
VGS = 15V, VBus = 133V
ID = 372A, RG = 1.2Ω 3944
µJ
Diode ratings and characteristics
Symbol Characteristic Test Conditions Min Typ Max Unit
IF(AV) Maximum Average Forward Current 50% duty cycle Tc = 90°C 300 A
IF = 300A 1 1.1
IF = 600A 1.4 VF Diode Forward Voltage
IF = 300A Tj = 125°C 0.9
V
Tj = 25°C 60
trr Reverse Recovery Time
IF = 300A
VR = 133V
di/dt = 600A/µs Tj = 125°C 110
ns
Tj = 25°C 600
Qrr Reverse Recovery Charge
IF = 300A
VR = 133V
di/dt = 600A/µs Tj = 125°C 2520 nC
u Eon includes diode reverse recovery.
v In accordance with JEDEC standard JESD24-1.