STTH9012TV Ultrafast recovery - 1200 V diode Main product characteristics IF(AV) 2 x 45 A VRRM 1200 V Tj 150 C VF (typ) 1.20 V trr (typ) 50 ns K2 A2 A2 K1 K1 A1 K2 A1 STTH9012TV2 STTH9012TV1 A1 Features and benefits Ultrafast, soft recovery Very low conduction and switching losses High frequency and/or high pulsed current operation High reverse voltage capability High junction temperature Insulated package: Electrical insulation = 2500 VRMS Capacitance = 45 pF A1 K1 A2 K2 K1 A2 K2 ISOTOP Order codes Part Number Marking STTH9012TV1 STTH9012TV1 STTH9012TV2 STTH9012TV2 Description The high quality design of this diode has produced a device with low leakage current, regularly reproducible characteristics and intrinsic ruggedness. These characteristics make it ideal for heavy duty applications that demand long term reliability. Such demanding applications include industrial power supplies, motor control, and similar mission-critical systems that require rectification and freewheeling. These diodes also fit into auxiliary functions such as snubber, bootstrap, and demagnetization applications. The improved performance in low leakage current, and therefore thermal runaway guard band, is an immediate competitive advantage for this device. March 2006 Rev 1 1/8 www.st.com 8 Characteristics STTH9012TV 1 Characteristics Table 1. Absolute ratings (limiting values per diode at 25 C, unless otherwise specified) Symbol Parameter Value Unit VRRM Repetitive peak reverse voltage 1200 V IF(RMS) RMS forward current 150 A 45 A IF(AV) Average forward current, = 0.5 IFRM Repetitive peak forward current tp = 5 s, F = 5 kHz square 600 A IFSM Surge non repetitive forward current tp = 10 ms Sinusoidal 420 A Tstg Storage temperature range -65 to + 150 C 150 C Tj Table 2. Tc = 75 C per diode Maximum operating junction temperature Thermal parameters Symbol Parameter Value Rth(j-c) Junction to case Rth(c) Coupling thermal resistance Per diode 0.74 Total 0.42 Unit C/W 0.1 When the diodes are used simultaneously: Tj(diode1) = P(diode1) x Rth(j-c) (per diode) + P(diode2) x Rth(c) Table 3. Symbol IR(1) Static electrical characteristics Parameter Reverse leakage current Test conditions Tj = 25 C Tj = 125 C Min. Typ Forward voltage drop Tj = 125 C A 30 300 2.10 IF = 45 A Tj = 150 C 1. Pulse test: tp = 5 ms, < 2 % 2. Pulse test: tp = 380 s, < 2 % To evaluate the conduction losses use the following equation: P = 1.40 x IF(AV) + 0.0089 IF2(RMS) 2/8 Unit 30 VR = VRRM Tj = 25 C VF(2) Max. 1.25 1.90 1.20 1.80 V STTH9012TV Characteristics Table 4. Dynamic characteristics Symbol Parameter Test conditions Min. Typ Max. IF = 1 A, dIF/dt = -50 A/s, VR = 30 V, Tj = 25 C Unit 125 IF = 1 A, dIF/dt = -100 A/s, VR = 30 V, Tj = 25 C 63 85 IF = 1 A, dIF/dt = -200 A/s, VR = 30 V, Tj = 25 C 50 70 Reverse recovery current IF = 45 A, dIF/dt = -200 A/s, VR = 600 V, Tj = 125 C 32 45 A S Softness factor IF = 45 A, dIF/dt = -200 A/s, VR = 600 V, Tj = 125 C 1 tfr Forward recovery time dIF/dt = 100 A/s IF = 45 A VFR = 1.5 x VFmax, Tj = 25 C 700 ns Forward recovery voltage IF = 45 A, dIF/dt = 100 A/s, Tj = 25 C trr Reverse recovery time IRM VFP Figure 1. Conduction losses versus average current Figure 2. P(W) 4.5 ns V Forward voltage drop versus forward current IFM(A) 110 =0.05 100 200 =1 =0.5 =0.2 =0.1 180 90 Tj=150C (Maximum values) 160 80 140 70 Tj=150C (Typical values) 120 60 100 50 Tj= 25 C (Maximum values) 80 40 30 60 T 40 20 10 =tp/T IF(AV)(A) tp 20 0 0 10 20 30 40 50 60 0 0.0 VFM(V) 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 3/8 Characteristics Figure 3. STTH9012TV Relative variation of thermal impedance junction to case versus pulse duration Figure 4. Zth(j-c)/Rth(j-c) Peak reverse recovery current versus dIF/dt (typical values) IRM(A) 1.0 80 0.9 70 0.8 VR=600V Tj=125C IF= 2 x IF(AV) 60 IF= IF(AV) 0.7 50 0.6 IF=0.5 x IF(AV) 40 0.5 0.4 30 Single pulse 0.3 20 0.2 0.1 10 tp(s) dIF/dt(A/s) 0 0.0 1.E-03 1.E-02 Figure 5. 1.E-01 1.E+00 0 1.E+01 Reverse recovery time versus dIF/dt (typical values) 50 Figure 6. 100 150 200 250 300 350 400 450 500 Reverse recovery charges versus dIF/dt (typical values) Qrr(C) trr(ns) 12 1000 VR=600V Tj=125C 900 VR=600V Tj=125C 10 IF= 2 x IF(AV) IF= 2 x IF(AV) 800 8 IF= IF(AV) 700 600 6 IF= IF(AV ) IF=0.5 x IF(AV) 500 4 400 IF=0.5 x IF(AV) 2 300 dIF/dt(A/s) dIF/dt(A/s) 200 0 50 Figure 7. 100 150 200 250 0 300 350 400 450 500 Softness factor versus dIF/dt (typical values) 0 50 Figure 8. S factor 100 150 200 250 300 350 400 450 500 Relative variations of dynamic parameters versus junction temperature 2.00 2.00 IF = 2 x IF(AV) VR=600V Tj=125C 1.75 IF = IF(AV) VR=600V Reference: Tj=125C 1.75 Sfactor 1.50 1.50 1.25 1.00 1.25 IRM 0.75 1.00 0.50 tRR 0.25 0.75 dIF/dt(A/s) 0.00 25 0.50 0 4/8 50 100 150 200 250 300 350 400 450 500 QRR Tj(C) 50 75 100 125 STTH9012TV Figure 9. Characteristics Transient peak forward voltage versus dIF/dt (typical values) Figure 10. Forward recovery time versus dIF/dt (typical values) tfr(ns) VFP(V) 1400 25 IF = IF(AV) Tj=125C IF = IF(AV) VFR = 1.5 x V F max. Tj=125C 1200 20 1000 15 800 10 600 5 400 dIF/dt(A/s) dIF/dt(A/s) 200 0 0 100 200 300 400 500 0 100 200 300 400 500 Figure 11. Junction capacitance versus reverse voltage applied (typical values) C(pF) 1000 F=1MHz Vosc=30mVRMS Tj=25C 100 VR(V) 10 1 10 100 1000 5/8 Package information 2 STTH9012TV Package information Epoxy meets UL94, V0 Cooling method: by conduction (C) Table 5. ISOTOP dimensions DIMENSIONS REF. E Inches Min. Max Min. Max. A 11.80 12.20 0.465 0.480 A1 8.90 9.10 0.350 0.358 B 7.8 8.20 0.307 0.323 E2 C 0.75 0.85 0.030 0.033 F C2 1.95 2.05 0.077 0.081 D 37.80 38.20 1.488 1.504 D1 31.50 31.70 1.240 1.248 E 25.15 25.50 0.990 1.004 E1 23.85 24.15 0.939 0.951 G2 A Millimeters C A1 C2 F1 P1 D G S D1 E2 24.80 typ. 0.976 typ. G 14.90 15.10 0.587 0.594 G1 12.60 12.80 0.496 0.504 G2 3.50 4.30 0.138 0.169 F 4.10 4.30 0.161 0.169 G1 F1 4.60 5.00 0.181 0.197 E1 P 4.00 4.30 0.157 0.69 P1 4.00 4.40 0.157 0.173 S 30.10 30.30 1.185 1.193 B OP In order to meet environmental requirements, ST offers these devices in ECOPACK(R) packages. These packages have a lead-free second level interconnect. The category of second level interconnect is marked on the package and on the inner box label, in compliance with JEDEC Standard JESD97. The maximum ratings related to soldering conditions are also marked on the inner box label. ECOPACK is an ST trademark. ECOPACK specifications are available at: www.st.com. 6/8 STTH9012TV 3 4 Ordering information Ordering information Part Number Marking Package Weight Base qty Delivery mode STTH9012TV1 STTH9012TV1 ISOTOP 27 g 10 Tube STTH9012TV2 STTH9012TV2 ISOTOP 27 g 10 Tube Revision history Date Revision 02-Mar-2006 1 Description of Changes First issue. 7/8 STTH9012TV Please Read Carefully: Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries ("ST") reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notice. All ST products are sold pursuant to ST's terms and conditions of sale. Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no liability whatsoever relating to the choice, selection or use of the ST products and services described herein. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products or services, or any intellectual property contained therein or considered as a warranty covering the use in any manner whatsoever of such third party products or services or any intellectual property contained therein. UNLESS OTHERWISE SET FORTH IN ST'S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION), OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. UNLESS EXPRESSLY APPROVED IN WRITING BY AN AUTHORIZE REPRESENTATIVE OF ST, ST PRODUCTS ARE NOT DESIGNED, AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING APPLICATIONS, NOR IN PRODUCTS OR SYSTEMS, WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL INJURY, DEATH, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE. Resale of ST products with provisions different from the statements and/or technical features set forth in this document shall immediately void any warranty granted by ST for the ST product or service described herein and shall not create or extend in any manner whatsoever, any liability of ST. ST and the ST logo are trademarks or registered trademarks of ST in various countries. Information in this document supersedes and replaces all information previously supplied. The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners. (c) 2006 STMicroelectronics - All rights reserved STMicroelectronics group of companies Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America www.st.com 8/8