J2R0019-41-31 l OR D229 REED SWITCH ORD229 High Breakdown Voltage n GENERAL DESCRIPTION The ORD229 is a single-contact reed switch designed for high breakdown voltage of 600 VDC and high power of AC 70 VA and DC 50 W. The contacts are sealed within the glass tube with inert gas to maintain contact reliability. n FEATURES (1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any influence from the external atmospheric environment. (2) Quick response (3) The structure comprises an operating system and electrical circuits coaxially. Reed switches are suited to applications in radio frequency. (4) Reed switches are compact and light weight. (5) Superior corrosion resistance and wear resistance of the contacts assures stable switching operation and long life. (6) With a permanent magnet installed, reed switches economically and easily become proximity switches. n EXTERNAL DIMENSIONS (Unit: mm) f0.6 MAX f2.75 MAX 21.0 55.40.3 n APPLICATIONS l Automotive electronic devices l Control equipment l Communication equipment l Measurement equipment l Household appliances 95 l ORD229 n ELECTRICAL CHARACTERISTICS Parameter Rated value Unit 2060 AT Pull-in Value (PI) Drop-out Value (DO) 6min AT Contact resistance (CR) 100 mW 600 min (PI35) VDC 500 min (PI 20 to 35) VDC Breakdown voltage Insulation resistance 1010min W Electrostatic capacitance 0.5max pF 50 W 70 VA 300AC V Contact rating Maximum switching voltage Maximum switching current 350DC V DC0.7/AC0.5 A 2.5 A Maximum carry current (2) Contact resistance (1) Drop-out Value vs. Pull-in Value (Measurement length: 32mm) 99.9 Cumulative frequency percent (%) Drop-out Value AT 50 40 30 20 10 0 95 90 80 70 60 50 40 30 20 10 5 1 0.1 10 20 30 40 Pull-in Value 96 99 50 60 AT 40 60 80 Contact resistance 100 mW ORD229 l (3) Breakdown voltage (4) Insulation resistance DC100V Cumulative frequency percent (%) 99.9 Breakdown voltage DCV 800 600 400 200 0 10 20 30 40 50 Pull-in Value 60 AT 99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 1010 1011 1012 1013 1014 W Insulation resistance (5) Electrostatic capacitance (1MHz) Electrostatic capacitance pF 0.4 0.3 0.2 0.1 0 10 20 30 Pull-in Value 40 50 60 AT 97 l ORD229 n OPERATING CHARACTERISTICS Rated value Unit Operate time Parameter 0.6max ms Bounce time 0.5max ms Release time 0.05max ms 2500250 Hz 500 Hz Resonant frequency Maximum operating frequency (1) Operate time (2) Bounce time (25Hz: 100AT energized) (25Hz: 100AT energized) 99.9 Cumulative frequency percent (%) ms 0.5 Operate time 0.4 0.3 0.2 0.1 99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 0 10 20 30 40 50 Pull-in Value 0 60 AT 0.1 0.2 (3) Release time Release time ms 15 10 5 20 30 40 Drop-out Value 98 50 Cumulative frequency percent (%) (25Hz: 100AT energized) 10 0.4 ms (4) Resonant frequency (25Hz: 100AT energized) 99.9 0 0.3 Bounce time 99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 AT 2250 2500 2750 Resonant frequency Hz ORD229 l n MECHANICAL CHARACTERISTICS (1) Lead tensile test (static load) (2) Lead tensile strength 2.27kg-10sec 99.9 Cumulative frequency percent (%) Pull-in Value * Drop-out Value AT 60 50 40 PI 30 DO 20 10 99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 0 2 4 Contact resistance 6 8 10kg Breaking load 0 mW 80 60 CR 40 Before test After test n ENVIRONMENTAL CHARACTERISTICS (1) Temperature characteristics 40 CR Rate of change percent 30 20 DO 10 PI 0 -10 -20 -30 -40 -20 0 20 40 60 80 100 120 Temperature 99 l ORD229 (2) Temperature cycle (3) Temperature and humidity cycle -10 to 65 80% to 98% (-55 to 125 ) AT 60 Pull-in Value * Drop-out Value Pull-in Value * Drop-out Value AT 60 50 40 PI 30 DO 20 40 PI 30 DO 20 10 0 0 mW 80 mW 80 Contact resistance Contact resistance 10 50 60 CR 40 Before test 60 CR 40 After test Before test (4) High temperature storage test (5) Low temperature storage test (-40-500H) (+125-500H) AT 60 Pull-in Value * Drop-out Value Pull-in Value * Drop-out Value AT 60 50 40 PI 30 20 DO 40 PI 30 DO 20 0 0 mW 80 mW 80 Contact resistance Contact resistance 50 10 10 60 CR 40 Before test 100 After test After test 60 CR 40 Before test After test ORD229 l (6) Shock test 1) Electrical characteristics 2) Misoperation area (openclose) (30G: 11ms) AT 60 G 50 40 PI Acceleration Pull-in Value * Drop-out Value 1500 30 DO 20 1000 Misoperation area 10 500 Contact resistance 0 mW 80 60 0 CR 10 20 30 40 50 60 AT Pull-in Value 40 Before test After test (7) Vibration test (20G: 101000Hz) Pull-in Value * Drop-out Value AT 60 50 40 PI 30 DO 20 10 Contact resistance 0 mW 80 60 CR 40 Before test After test 101 l ORD229 n LIFE EXPECTANCY DATA: ORD229 Load conditions Voltage: 200VAC Current: 200mA , 250mA Load: Resistive load Cumulative failure rate % 99.9 90 70 50 30 No failure 200mA 250mA 10 5 1 0.1 0 2 3 5 7 105 23 57 106 57 107 23 23 57 108 * Arrow indicates number of operations where test was completed. Number of operations Load conditions Voltage: 350VDC, 270VDC Current: 1mA, 270A Load: Resistive load Cumulative failure rate % 99.9 90 70 50 30 No failure 350V 1mA 270V 270mA 10 5 1 0.1 0 2 3 5 7 105 23 57 106 23 Number of operations 57 107 23 57 108 * Arrow indicates number of operations where test was completed. Load conditions Voltage: 100VDC, 50VDC Current: 0.5A, 1.0A, 0.5A Load: Resistive load Cumulative failure rate % 99.9 50V 1A 90 70 50 30 100V 0.5A No failure 50V-0.5A 10 5 1 0.1 0 2 3 5 7 105 2 3 5 7 106 2 3 Number of operations 102 5 7 107 2 3 5 7 108 * Arrow indicates number of operations where test was completed. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Standex Electronics: ORD229-2530 ORD229/20-25 AT