+1 507.833.8822
cinchconnectivity.com
16
SMP Straight Female Solder Style for .086 OD
Semi-Rigid Cable
1. Identify tools (6 piece parts) and connector parts (2
piece parts).
2. Strip cable jacket and dielectric to dimension shown. Do
not nick center conductor. Clean all debrisfrom prepared
cable.
3. Place contact onto center conductor, insert solder shim
between cable jacket and contact.
4. Insert contact into contact holderxture and clamp
cable in vise. Tighten stop screw until light pressure is
applied between con-tact, solder shim and cable jacket.
5. Solder contact to center conductor through solder hole
using .016 (0.41) diameterux core solder wire or solder
paste. Use a minimum amount of solder and heatfor
a good joint. Do not allow heat to build upfor a long
period of time as cable dielectric will expand.
6. After solder joint has cooled, remove solder shim and
cablefrom vise. Remove any excess solderfrom contact
with a sharp blade and clean all debrisfrom contact and
cable.
7. Insert contact into connector assembly, making sure
cable jacket bottoms out against internal shoulder
of connector body. Insert connector assembly into
interface locationxture and clamp cable in vise. Make
sure connector assembly isfully en-gaged within
locationxture. Tighten stop screw until light pres-sure is
applied between connector assembly and cable jacket.
8. 8. Solder end of connector body to cable jacket, using
a minimum amount of solder and heatfor afullllet joint.
Allow assembly to cool before removing connectorfrom
vise and locationxture. Best results are obtained when
contact location isush to .004 (0.10) recessedfrom
reference plane. Interface locationxture is pre-set
atfactory, but can be adjusted to control location.
Cable Group Part Number
RG-405, .086 Semi-Rigid 127-0693-001
Tool Part Number
Cable Vise 140-0000-962
Stop Screw 140-0000-981
Clamp Inserts 140-0000-964
Solder Shim 140-0000-984
Contact Holder 127-0000-902
Interface Location Fixture 127-0000-903