53RV Series
• Three-phase Motor Reversing solid-state relay;
• Ratings from 25A and 50A per phase @ 48-530 VAC
• Interlock Circuit Prevents Inadvertent Actuation of Both Directions
• SCR output for heavy industrial loads
• DC control
• LED input status indicator
PRODUCT SELECTION
Control Voltage 25A 50A
4-32 VDC D53RV25C D53RV50C
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description D53RV25C D53RV50C
Operating Voltage (47-63Hz) [Vrms] 48-530 48-530
Maximum Load Current [Arms] (2) 25 50
Transient Overvoltage [Vpk] 1100 1100
Maximum Off-State Leakage Current @ Rated Voltage [mArms] (3) 6 6
Minimum Load Current [Arms] 0.1 0.1
Maximum Surge Current 50/60 Hz (16.6ms) [Apk] 475/500 710/750
1 Second Surge Current 50/60 Hz [Apk] 100 150
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.35 1.35
Maximum I²T for Fusing (50/60 Hz, 1/2 cycle) [A² sec] 1139/1038 2520/2320
Thermal Resistance Junction to Case (Rjc ) [°C/W] 0.26 0.25
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (4) 500 500
UL/IEC 60947 Motor Control Ratings at 120V [HP/KW] (5) 0.75/0.56 1.5/1.11
UL/IEC 60947 Motor Control Ratings at 240V [HP/KW] (5) 1/0.74 3/2.22
UL/IEC 60947 Motor Control Ratings at 380V [HP/KW] (5) 2/1.48 5/3.7
UL/IEC 60947 Motor Control Ratings at 480V [HP/KW] (5) 3/2.22 7.5/5.55
INPUT SPECIFICATIONS (1)
Description Parameters
Control Voltage Range 4-32 VDC
Minimum Turn-On Voltage 4.0 VDC
Minimum T urn -Off Voltage 1.0 VDC
Minimum Input Current (for on-state) 23mA
Maximum Input Current 35mA
Input Resistance Current Regulated
Maximum Turn-On Time [msec] 150
Maximum Turn-Off Time [msec] 1/2 Cycle
Interlocking Time [msec] 100
GENERAL SPECIFICATIONS
Description Parameters
Input to Output Isolation 4000 Vrms
Input/ Output to Ground Isolation 2500 Vrms
Maximum Capacitance, Input/Output 8 pF
Ambient Operating Temperature Range -40 to 80°C
Ambient Storage Temperature Range -40 to 100 °C
Weight (typical) 13.1 oz (370g)
Housing Material UL 94V0 (self extinguishing
Terminals Mounted
Input Terminal Screw Torque Range:[in lbs/Nm] 16.8/1.9
Output Terminal Screw Torque Range:[in lbs/Nm] 21.2/2.4
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) When mounted to the proper size heat sink (see derating curves)
3) Measured between 1/L1 and 2/T1 or 3/L2 and 4/T2
4) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
5) At 40°C Ambient temperature.
THERMAL DERATE INFORMATION
MECHANICAL SPECIFICATIONS
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
Rev. 120811