Pb GBU10005 - GBU1010 10A GLASS PASSIVATED BRIDGE RECTIFIER Features Mechanical Data * * * * * * * * * Glass Passivated Die Construction High Case Dielectric Strength of 1500VRMS Low Reverse Leakage Current Surge Overload Rating to 220A Peak Ideal for Printed Circuit Board Applications UL Listed Under Recognized Component Index, File Number E94661 Lead-Free Finish; RoHS Compliant (Notes 1 & 2) * * * * * * * Case: GBU Case Material: Molded Plastic. UL Flammability Classification Rating 94V-0 Moisture Sensitivity: Level 1 per J-STD-020 Terminals: Matte Tin Finish. Solderable per MIL-STD 202, Method 208 Polarity: Marked on Body Mounting: Through Hole for #6 Screw Mounting Torque: 5.0 Inch-pounds Maximum Marking: Date Code and Type Number Weight: 4 grams (approximate) Ordering Information (Note 3) Part Number GBU10005-GBU1010 Notes: Case GBU Packaging 20/Tube 1. EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant. All applicable RoHS exemptions applied. 2. See http://www.diodes.com for more information about Diodes Incorporated's definitions of Halogen- and Antimony-free, "Green" and Lead-free. 3. For packaging details, go to our website at http://www.diodes.com. Maximum Ratings and Electrical Characteristics (@TA = +25C, unless otherwise specified.) Single phase, half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%. Characteristic Symbol Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage RMS Reverse Voltage Average Forward Rectified Current (Note 4) @ TC = +100C Non-Repetitive Peak Forward Surge Current 8.3ms Single Half Sine-Wave Superimposed on Rated Load Forward Voltage (per element) @ IF = 5.0A @ TC = +25C Peak Reverse Current at Rated DC Blocking Voltage @ TC = +125C 2 I t Rating for Fusing (Note 5) Typical Total Capacitance per Element (Note 6) Typical Thermal Resistance Junction to Case (Note 4) Operating and Storage Temperature Range Notes: VRRM VRWM VR VR(RMS) I(AV) GBU 10005 GBU 1001 GBU 1002 GBU 1004 GBU 1006 GBU 1008 GBU 1010 Unit 50 100 200 400 600 800 1000 V 35 70 140 280 10 420 560 700 V A IFSM 220 A VFM 1.0 5.0 500 200 60 2.2 -55 to +150 V IR 2 I t CT RJC TJ, TSTG A 2 A s pF C/W C 4. Unit mounted on 100mm x 100mm x 1.6mm copper plate heatsink. 5. Non-repetitive, for t > 1.0ms and < 8.3ms. 6. Measured at 1.0MHz and applied reverse voltage of 4.0V DC. GBU10005 - GBU1010 Document number: DS30052 Rev. 6 - 2 1 of 4 www.diodes.com November 2012 (c) Diodes Incorporated 10 IF, INSTANTANEOUS FORWARD CURRENT (A) I(AV), AVG FORWARD RECTIFIED CURRENT (A) GBU10005 - GBU1010 Resistive or Inductive Load 8 6 4 2 0 0 50 100 TC, CASE TEMPERATURE ( C) Figure 1 Forward Current Derating Curve 1.0 0.1 1,000 T J = 25 C f = 1.0MHz 200 CT, TOTAL CAPACITANCE (pF) IFSM, PEAK FORWARD SURGE CURRENT (A) TJ = 25 C 10 1.4 0 0.2 0.6 1.0 1.8 VF, INSTANTANEOUS FORWARD VOLTAGE (V) Figure 2 Typical Forward Characteristics, per element 150 250 100 Single half-sine wave 150 100 50 100 TJ = 25 C 0 1 10 100 NUMBER OF CYCLES AT 60Hz Figure 3 Maximum Non-Repetitive Surge Current GBU10005 - GBU1010 Document number: DS30052 Rev. 6 - 2 2 of 4 www.diodes.com 10 0.1 1.0 10 100 VR, REVERSE VOLTAGE (V) Figure 4 Typical Total Capacitance, per element November 2012 (c) Diodes Incorporated GBU10005 - GBU1010 Package Outline Dimensions Please see AP02002 at http://www.diodes.com/datasheets/ap02002.pdf for latest version. A B K M C L O - ~ ~ + D E F J N G P H GBU10005 - GBU1010 Document number: DS30052 Rev. 6 - 2 3 of 4 www.diodes.com GBU Dim Min Max A 21.8 22.3 B 3.5 4.1 C 7.4 7.9 D 1.65 2.16 E 2.25 2.75 F 1.95 2.35 G 1.02 1.27 H 4.83 5.33 J 17.5 18.0 K 3.2 X 45 L 18.3 18.8 M 3.30 3.56 N 0.46 0.56 O 1.90R P 0.76 1.0 All Dimensions in mm November 2012 (c) Diodes Incorporated GBU10005 - GBU1010 IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. This document is written in English but may be translated into multiple languages for reference. Only the English version of this document is the final and determinative format released by Diodes Incorporated. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright (c) 2012, Diodes Incorporated www.diodes.com GBU10005 - GBU1010 Document number: DS30052 Rev. 6 - 2 4 of 4 www.diodes.com November 2012 (c) Diodes Incorporated