E2EM
2
Accessories (Order Separately)
Sensor I/O Connectors (M12, Sockets on One Cable End)
(Models for Connectors and with Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.)
[Refer to XS2.]
Note: Refer to Introduction to Sensor I/O Connectors/Sensor Controllers for details.
Use the XS2F-D42@-@CO-A for the E2EM-X@X1-M1J. (Terminal 3: 0 V (+V), Terminal 4: +V (0 V))
Ratings and Specifications
E2EM-X@X@ DC 2-Wire Models
*1. Use the Sensor within the range in which the setting indicator (green LED) is ON (except X2 Models).
*2. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*3. The residual voltage is 5 V. Make sure that the device connected to the Sensor can withstand the residual voltage. (Refer to page 6 for details.)
Appearance Cable length Sensor I/O Connector model number Applicable Proximity Sensor model number
2 m XS2F-D421-DC0-F E2EM-X@C1-M1
5 m XS2F-D421-GC0-F
2 m XS2F-D421-D80-F E2EM-X@C@-M1
5 m XS2F-D421-G80-F
2 m XS2F-D422-DC0-F E2EM-X@C1-M1
5 m XS2F-D422-GC0-F
2 m XS2F-D422-D80-F E2EM-X@C@-M1
5 m XS2F-D422-G80-F
Size M12 M18 M30
Shielded Shielded Shielded Unshielded Shielded Unshielded
Item Model E2EM-X4X@E2EM-X8X@E2EM-X16MX@E2EM-X15X@E2EM-X30MX@
Sensing distance 4 mm ±10% 8 mm ±10% 16 mm ±10% 15 mm ±10% 30 mm ±10%
Set distance *10 to 3.2 mm 0 to 6.4 mm 0 to 12.8 mm 0 to 12 mm 0 to 24 mm
Differential travel 15% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 4.)
Standard sensing object Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 45 × 45 × 1 mm Iron, 30 × 30 × 1 mm Iron, 70 × 70 × 1 mm
Response frequency *21 kHz 0.5 kHz 0.4 kHz 0.25 kHz 0.1 kHz
Power supply voltage
(operating voltage
range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current 0.8 mA max.
Con-
trol out-
put
Load current 3 to 100 mA
Residual volt-
age *35 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators X1 Models: Operation indicator (red), Setting indicator (green)
X2 Models: Operation indicator (red)
Operation mode
(with sensing object
approaching)
X1 Models: NO
X2 Models: NC
Protection circuits Surge suppressor, Load short-circuit protection
Ambient temperature
range Operating: −25 to 70°C, Storage: −40 to 85°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±15% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 60 g Approx. 130 g Approx. 150 g Approx. 180 g Approx. 210 g
Materi-
als
Case Nickel-plated brass
Sensing sur-
face PBT
Clamping nuts Nickel-plated brass
Toothed washer
Zinc-plated iron
Accessories Instruction manual
Refer to the timing charts under I/O Circuit Diagrams on page 5 for details.