TYPE
APPLICATION SPECIFICATION
NUMBER
BUS-20-059
TITLE PAGE REVISION
1 of 8 D
AUTHORIZED BY
DATE
Metral™ B series Vertical Solder to Board Receptacles
(Signal and Power types)
J.R. Volstorf 31 Oct 05
CLASSIFICATION
UNRESTRICTED
Copyright 2005 FCI USA, INC.
Form E-3334
Rev B 06/06/05
V05-0553
GS-01-001
1.0 OBJECTIVE
This specification provides information and requirements regarding customer application of MetralTM B series
vertical solder to board receptacles. This specification is intended to provide general guidance for process
development. It is recognized that no single process will work under all customer applications and that customers
will develop their processes to meet their needs. However, FCI cannot guarantee results if these processes vary
from the recommendations.
2.0 SCOPE
This specification provides information and requirements regarding customer application of MetralTM B series
vertical solder to board receptacles.
3.0 REFERENCE DOCUMENTS
Any applicable product drawing
GS-12-002, MetralTM Connector System
4.0 GENERAL
This document is meant to be an application guide. If information varies from that in the product drawings and
specifications, the drawings and specifications take precedence.
This document contains the following sections:
Paragraph Title Page
1.0 Objective 1
2.0 Scope 1
3.0 Reference Documents 1
4.0 General 1
5.0 Application Information 2
5.1 General Product Information 2
5.1.1 Location peg information 2
5.1.2 Component masses 2
5.1.3 Application forces 2
5.2 Available Product Features 3
5.3 PCB Requirements 4
5.4 Customer Design Considerations 6
5.5 Customer Application Machines (CAMS) 7
5.6 Post-Installation Inspection Criteria 7
Revision Record 8
4.1 Banned/Restricted Substances
All product where the part number ends in ‘LF’ meet the European Union directives and other
country regulations as described in GS-22-008. The part numbers that do not end in ‘LF’ meet all
regulations except for Pb in SnPb plating.
4.2 Manufacturing Processability
All products covered by this specification will withstand exposure to 260°C for 60 seconds in a
convection, infra-red or vapor phase reflow oven.
PDM: Rev:D Released .STATUS: Printed: Nov 28, 2010
TYPE
APPLICATION SPECIFICATION
NUMBER
BUS-20-059
TITLE PAGE REVISION
2 of 8 D
AUTHORIZED BY
DATE
Metral™ B series Vertical Solder to Board Receptacles
(Signal and Power types)
J.R. Volstorf 31 Oct 05
CLASSIFICATION
UNRESTRICTED
Copyright 2005 FCI USA, INC.
Form E-3334
Rev B 06/06/05
V05-0553
GS-01-001
5.0 APPLICATION INFORMATION
5.1 General Product Information
5.1.1 Location peg information
There are two location pegs on the bottom side of the connector. These pegs perform two functions:
1) They properly locate the connector onto the PCB
2) They serve as a retention feature during the subsequent soldering process
5.1.2 Component masses:
5.1.3 Application forces:
For a vertical receptacle assembly the number location pegs will determine the force required to properly apply the
assembly to the board before soldering. The recommended insertion force for each location peg is 53 N (12 lbf).
Figure 1: 4 row vertical solder to board signal receptacle.
Table 1: Approximate mass of components (in grams)
4 row 1 mod 2 mod 4 mod 8 mod
Housing (plastic) 1.18 2.36 4.72 9.44
Wafer (plastic) 0.51 1.02 2.04 4.08
Total assembly 2.95 5.9 11.8 23.6
5 row 1 mod 2 mod 4 mod 8 mod
Housing (plastic) 1.37 2.74 5.48 10.96
Wafer (plastic) 0.57 1.14 2.28 4.56
Total assembly 3.51 7.02 14.04 28.08
PDM: Rev:D Released .STATUS: Printed: Nov 28, 2010
TYPE
APPLICATION SPECIFICATION
NUMBER
BUS-20-059
TITLE PAGE REVISION
3 of 8 D
AUTHORIZED BY
DATE
Metral™ B series Vertical Solder to Board Receptacles
(Signal and Power types)
J.R. Volstorf 31 Oct 05
CLASSIFICATION
UNRESTRICTED
Copyright 2005 FCI USA, INC.
Form E-3334
Rev B 06/06/05
V05-0553
GS-01-001
5.2 Available Product Features
The features of vertical solder to board B-style MetralTM receptacle connectors include:
Standard module size is 12 mm.
4 row and 5 row configurations are available.
Each 4 row 12mm module contains 24 signal terminals or 8 power terminals.
Each 5 row 12mm module contains 30 signal terminals or 10 power terminals.
Signal terminals are located on a 2 mm x 2 mm grid for high signal density.
1, 2, 4, and 8 module connectors are standard. Other sizes are available.
Standard tail lengths include 2.65mm (for use with a 1.6mm nominal thickness PCB), 3.45mm (for use
with a 2.4mm nominal thickness PCB), and 4.25mm (for use with a 3.2mm nominal thickness PCB)
Terminals may be selectively loaded.
Available accessories which are end-to-end stackable include guide, keying, DIN power, and Din coax.
Tail
Length
Figure 2: Vertical solder to board 4 row signal receptacle (all dimensions in mm)
PDM: Rev:D Released .STATUS: Printed: Nov 28, 2010
TYPE
APPLICATION SPECIFICATION
NUMBER
BUS-20-059
TITLE PAGE REVISION
4 of 8 D
AUTHORIZED BY
DATE
Metral™ B series Vertical Solder to Board Receptacles
(Signal and Power types)
J.R. Volstorf 31 Oct 05
CLASSIFICATION
UNRESTRICTED
Copyright 2005 FCI USA, INC.
Form E-3334
Rev B 06/06/05
V05-0553
GS-01-001
5.3 PCB Requirements
The features that are important to define on the printed circuit board when using press fit technology are:
Drilled hole diameter
Plated hole diameter
Plating type in thru hole
Printed circuit board thickness
Land/pad size
The recommended values are shown on customer drawing 58531, and a sketch showing these features is shown in
Figure 3.
Figure 3: Critical features of PCB design for MetralTM Connectors.
PDM: Rev:D Released .STATUS: Printed: Nov 28, 2010
TYPE
APPLICATION SPECIFICATION
NUMBER
BUS-20-059
TITLE PAGE REVISION
5 of 8 D
AUTHORIZED BY
DATE
Metral™ B series Vertical Solder to Board Receptacles
(Signal and Power types)
J.R. Volstorf 31 Oct 05
CLASSIFICATION
UNRESTRICTED
Copyright 2005 FCI USA, INC.
Form E-3334
Rev B 06/06/05
V05-0553
GS-01-001
Figure 4: Board layout for right vertical solder to board receptacles (all dimensions in mm)
PDM: Rev:D Released .STATUS: Printed: Nov 28, 2010
TYPE
APPLICATION SPECIFICATION
NUMBER
BUS-20-059
TITLE PAGE REVISION
6 of 8 D
AUTHORIZED BY
DATE
Metral™ B series Vertical Solder to Board Receptacles
(Signal and Power types)
J.R. Volstorf 31 Oct 05
CLASSIFICATION
UNRESTRICTED
Copyright 2005 FCI USA, INC.
Form E-3334
Rev B 06/06/05
V05-0553
GS-01-001
5.4 Customer Design Considerations
Receptacles should be placed on 12 mm increments within a slot to be consistent with the preferred module
placement). If 12 mm increments are not possible, receptacles should be placed on multiples of 2 mm within a
slot.
Keep receptacles a minimum of 4 mm from any edge of the backpanel to avoid handling and shipping damage.
In applications that require additional components to be mounted from the non-component side, a minimum slot
spacing of 22 mm is preferred to accommodate fixturing.
The solder tail on the vertical solder to board receptacle is offset relative to the mating contact window. This
offset distance, 0.63 mm, is shown in Fig. 5.
Refer to Fig. 6 for nominal board-to-board offsets for fully mated vertical receptacles.
Figure 6: Nominal board-to-board offsets for vertical receptacles mated to r/a and vertical headers
Figure 5: Vertical solder to board receptacle offset
PDM: Rev:D Released .STATUS: Printed: Nov 28, 2010
TYPE
APPLICATION SPECIFICATION
NUMBER
BUS-20-059
TITLE PAGE REVISION
7 of 8 D
AUTHORIZED BY
DATE
Metral™ B series Vertical Solder to Board Receptacles
(Signal and Power types)
J.R. Volstorf 31 Oct 05
CLASSIFICATION
UNRESTRICTED
Copyright 2005 FCI USA, INC.
Form E-3334
Rev B 06/06/05
V05-0553
GS-01-001
5.5 Customer Application Machines (CAMS)
There are no special CAM’s for this product. The required top press tool is simply a “flat rock” tool. Be sure there is
a bottom fixture that allows the tails to protrude through the board while applying the connectors.
5.6 Post-Installation Inspection Criteria
Gap between bottom surface of receptacle housing and top surface of PCB
In order to decrease the risk of interference between mating connector parts during insertion of the circuit board into
the shelf system, it is desirable to not have a gap larger than 0.2mm (.008in) between the bottom surface of the
connector receptacle housing and the top surface of the PCB.
PDM: Rev:D Released .STATUS: Printed: Nov 28, 2010
TYPE
APPLICATION SPECIFICATION
NUMBER
BUS-20-059
TITLE PAGE REVISION
8 of 8 D
AUTHORIZED BY
DATE
Metral™ B series Vertical Solder to Board Receptacles
(Signal and Power types)
J.R. Volstorf 31 Oct 05
CLASSIFICATION
UNRESTRICTED
Copyright 2005 FCI USA, INC.
Form E-3334
Rev B 06/06/05
V05-0553
GS-01-001
REVISION RECORD
REV PAGE DESCRIPTION EC# DATE
A All New Release V90298 03/19/99
B All Revised format to be consistent with GS-01-001, and
change BERG, Dupont, etc. references to FCI.
V01922 08/07/00
C All Extensive revisions including removal of performance
specifications, part number tables, and order forms;
added location peg force requirement of 12 lb; added
post-installation inspection criteria
V11863 12/28/01
D All Add lead free information V05-0936 10/31/05
PDM: Rev:D Released .STATUS: Printed: Nov 28, 2010