TYPE
APPLICATION SPECIFICATION
NUMBER
BUS-20-059
TITLE PAGE REVISION
1 of 8 D
Metral™ B series Vertical Solder to Board Receptacles
(Signal and Power types)
J.R. Volstorf 31 Oct 05
UNRESTRICTED
Copyright 2005 FCI USA, INC.
Form E-3334
Rev B 06/06/05
V05-0553
GS-01-001
1.0 OBJECTIVE
This specification provides information and requirements regarding customer application of MetralTM B series
vertical solder to board receptacles. This specification is intended to provide general guidance for process
development. It is recognized that no single process will work under all customer applications and that customers
will develop their processes to meet their needs. However, FCI cannot guarantee results if these processes vary
from the recommendations.
2.0 SCOPE
This specification provides information and requirements regarding customer application of MetralTM B series
vertical solder to board receptacles.
3.0 REFERENCE DOCUMENTS
Any applicable product drawing
GS-12-002, MetralTM Connector System
4.0 GENERAL
This document is meant to be an application guide. If information varies from that in the product drawings and
specifications, the drawings and specifications take precedence.
This document contains the following sections:
Paragraph Title Page
1.0 Objective 1
2.0 Scope 1
3.0 Reference Documents 1
4.0 General 1
5.0 Application Information 2
5.1 General Product Information 2
5.1.1 Location peg information 2
5.1.2 Component masses 2
5.1.3 Application forces 2
5.2 Available Product Features 3
5.3 PCB Requirements 4
5.4 Customer Design Considerations 6
5.5 Customer Application Machines (CAMS) 7
5.6 Post-Installation Inspection Criteria 7
Revision Record 8
4.1 Banned/Restricted Substances
All product where the part number ends in ‘LF’ meet the European Union directives and other
country regulations as described in GS-22-008. The part numbers that do not end in ‘LF’ meet all
regulations except for Pb in SnPb plating.
4.2 Manufacturing Processability
All products covered by this specification will withstand exposure to 260°C for 60 seconds in a
convection, infra-red or vapor phase reflow oven.