For the Latest Information
On the Internet: www.sti.com
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D36
D
Position Detection Muting Function
Position Detection
Muting Function is
used in applications
where the workpiece
is set in position
each time by an
operator, and a
turntable or position-
ing robot then moves
the workpiece to the
area where the work
is performed. A limit switch or other means is used to detect when
the robot is in a safe position and muting is then applied.
Partial Muting Function
Muting temporarily disables the F3SJ-A when an object must
pass through the detection zone, such as when supplying a
workpiece to your equipment.
Partial muting
increases the level of
safety by only muting
the beams of the
safety light curtain
where the workpiece
passes through, while
preventing muting in
all other areas.
Warning Zone Function
With the F3SJ-A, part of the detection zone can be used as
warning zone to generate an alarm when someone approaches
the danger zone. If the person then enters the danger zone the
F3SJ-A will send a stop signal to the guarded machine. In addi-
tion, the auxiliary output can be used to activate a flashing lamp
to alert the person in the warning zone.
The detection zone for a single F3SJ-A can be divided into two
zones or set a single warning zone for multiple, cascaded F3SJ-A
units.
The F3SJ-A beams
continue to guard all
areas except for where
the workpiece passes
through.
Only the beams of the safety
light curtain interrupted by
the workpiece are muted.
Detection zone
Warning zone
Dividing the zone between series-connected sensors
Safety Light Curtains
Resolution: 14 mm (0.55 in.), 20 mm (0.79 in.), 25 mm (1.01 in.)
30 mm (1.18 in.), or 55 mm (2.17 in.)
Range: 7 m (23 ft.) or 9 m (29.5 ft.) dependent on minimum
object resolution and protected height
Protected heights: 14 mm protected heights from 245 to 1631
mm (9.6 to 64 in.), 20 mm, 25 mm and 30 mm protected
heights from 245 to 2495 mm (9.6 to 98 in.), 55 mm from 270 to
2470 mm (10.6 to 97 in.)
Very compact size – 30 x 24 mm (1.18 x 0.94 in.)
Cascaded designs possible – 4 segments, up to 400 beams
Partial muting and position detection muting
Cross-talk prevention
Description
Safety Light Curtains
F3SJ-A F3SJA
Rev. 2.12
This datasheet has been downloaded fromhttp://www.digchip.com at this page
D37
For the Latest Information
On the Internet: www.sti.com
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D
Using the SD Manager software, all
features of the F3SJ-A can be set and
checked. Features include:
Display of system specifications:
Model
Number of beams
Minimum object resolution
Response time
Settings for:
Fixed blanking
Floating blanking
Warning zone configuration
Muting – Both partial and position
detection
External indicator function
Auxiliary outputs
EDM parameters
Operating range
Monitoring of received and ambient
light intensity
Maintenance information:
Power on time
OSSD switching frequency
Recovery of settings
Safety distance calculations based on
parameters for connected system
Setting Console
When you don’t want to take a computer into
the field with you the F39-MC21 setting console
is a convenient way to set parameters and
check the system status.
“SD Manager” PC Setting Software
F3SJ-A
Branch
Connector
Connection Cable
To a USB terminal
All parameters can be set and the system status can be checked
with a personal computer. In addition to making it easy to monitor
the beam alignment, the ambient incident light intensity can be
displayed in bar graph form for an easy check of the system status.
F39-GWUM
“SD Manager”
PC Setting
Software
F3SJ-A Safety Light Curtains
SD Manager Software
With built-in muting and
blanking functions, the F3SJ-A
can be employed in a wide
variety of applications from
robotic work cells to small
machines. The potential
for cascaded design and a
broad selection of minimum
object resolutions adds to this
versatility.
Applications
Selecting the Best Configuration
Space Efficient and Low Cost
The built-in external device monitoring function
eliminates the need for a safety relay unit.
No Safety Relay Unit
F39-JC®A
G7SA Contactor Motor
Connector Type
Reduced Wiring and Easy Maintenance
Cables with connectors on both ends simplify
connections and prevent wiring errors.
F39-JC®B
F3SP-B1P
Dedicated controller
Contactor Motor
The ambient incident light
intensity can be checked.
The error log can be displayed.
The incident light level can be displayed in a bar
graph for each beam.
The incident light level when the light emission of the
Safety Light Curtain is stopped is displayed in a bar
graph.
The cause of the errors and countermeasures are
both displayed.
Beam alignment is easier.
Beam Alignment is Easier
The incident light level can be displayed
in a bar graph for each beam.
For the Latest Information
On the Internet: www.sti.com
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D38
D
F3SP-B1P Control Unit
Power Supply Voltage: 24 VDC ±10%
Power Consumption: DC1.7 W max (not including sensor’s current consumption)
Operation Time: 100 ms max. (not including the sensor’s response time)
Response Time: 10 ms max. (not including the sensor’s response time)
Relay Output
Number of Contacts: 3 N.O., 1 N.C.
Rated Load: 250 VAC 5 A (cos = 1); 30 VDC 5 A L/R = 0 ms
Rated Current: 5 A
Connection Type
Between Sensors: M12 connector (8-pin)
Others: Terminal block
Weight: Approx. 280 g (9.9 oz.)
Specifications are subject to change without notice.
Specifications
Performance
Resolution: 14 mm, 20 mm, 25 mm, 30 mm, 55 mm
Protected Height: 14 mm – 245 to 1631 mm (9.6 to 64.2 in.)
20 mm, 25 mm and 30 mm – 245 to 2495 mm (9.6 to 98.2 in.)
55 mm – 270 to 2470 mm (10.6 to 97.2 in.)
Operating Range: 0.2 to 9 m for all protective heights up to 1640 mm (64.6 in.)
0.2 to 7 m for all protective heights longer than 1640 mm (64.6 in.):
Effective Aperture Angle: ±2.5° maximum, transmitter and receiver at operating range greater than 3 m (9.8 ft.)
Response Time: For 14 mm resolution systems up to 983 mm (38.7 in.) protected height 17.5 ms
For 14 mm resolution systems above 983 mm (38.7 in.) protected height 25 ms
For 20 mm resolution systems up to 1205 mm (47.4 in.) protected height 15 ms
For 20 mm resolution systems above 1205 mm (47.4 in.) protected height 22.5ms
For 25 mm resolution systems up to 1600 mm (63.0 in.) protected height 15 ms
For 25 mm resolution systems above 1600 mm (63.0 in.) protected height 20.0ms
For 30 mm resolution systems, all protected heights 17.5 ms
For 55 mm resolution systems, all protected heights 13 ms
Safety Output Rating: Two 24 VDC PNP outputs sourcing 300 mA max.
Auxiliary (Non-Safety) Output Ratings: One 24 VDC PNP output sourcing 300 mA max.
Light Source: Infrared LED, 870 nm
Indicators: Transmitter: 5 LED Light Level Indicators, 3 LED Error Indicators, Power, Interlock, EDM, Blanking/Test
Receiver: 5 LED Light Level Indicators, 3 LED Error Indicators, Machine Run, Machine Stop
Mechanical
Enclosure: Anodized aluminum housing
Cable Length: Optional cables are available up to 20 m (65.6 ft.) in length
Transmitter and Receiver Cable
Connections:
M12, 8-pin
Electrical
Power Supply: 24 VDC ± 20%
Environmental
Protection Rating: IP65
Operating Temperature: -10 to 55°C (14 to 131°F)
Storage Temperature: -30 to 70°C (-22 to 158°F)
Relative Humidity: 35 to 85% non-condensing
Vibration: 10 to 55 Hz, double amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions
Shock: 100 m/s2, 1000 times each in X, Y and Z directions
Approvals ESPE Type 4 (IEC 61496-1/ -2)
Category 4 / PL e (EN ISO 13849-1)
SIL3 / SIL3 CL3 (IEC 61508)UL508, UL1998, CAN/CSA-C22.2 No. 14, CAN/CSA-C22.2 No. 0.8
Specifications are subject to change without notice.
F3SJ-A Safety Light Curtains
D39
For the Latest Information
On the Internet: www.sti.com
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D
Wiring
Emitter
F39-JC@A-L F39-JC@A-D
Receiver
OUT
PLC
IN
Communication
line (+) (Gray)
Communication
line () (Pink)
Shield
0 V (Blue)
Auxiliary output 2 (Red)
S1
S2
Test input (Green)
Reset input (Yellow)
Interlock selection input (White)
+24 V (Brown)
+24 V (Brown)
External device monitoring input (Red)
KM1
KM2
Auxiliary output 1 (Yellow)
Control output 1 (Green)
Control output 2 (White)
0 V (Blue)
Shield
E1
+24 VDC
0 V
M
KM2
KM1
KM4
Light incident
Light interrupted
External test switch (S1)
Reset switch (S2)
Control output
KM1,KM2 N.O. contact
KM1,KM2 N.C. contact
PLC input (See note.)
PLC output
KM2KM1
KM3
Wiring for Single F3SJ-A Application
Detection of a welded relay contact is possible without a controller relay unit.
Manual reset mode
Using external device monitoring
function
F3SJ-A Safety Light Curtains
For the Latest Information
On the Internet: www.sti.com
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D40
D
Dimensions (mm)
Protective Height
Number of
Intermediate Brackets E*
245 to 596 mm (9.6 to 23.5 in.) 0
600 to 1130 mm (23.6 to 44.5 in.) 1 E = B/2
1136 to 1658 mm (44.7 to 65.3 in.) 2 E = B/3
1660 to 2180 mm (65.4 to 85.8 in.) 3 E = B/4
2195 to 2500 mm (86.4 to 98.4 in.) 4 E = B/5
*Use E = 530 or less when none of the E values shown above are used.
1
24
Intermediate mounting
bracket
300
43
6 dia.
15 dia. M12 Waterproof connector
9 dia.
13.75
2-Mounting holes
6.5 dia.
4-Mounting holes
37
10
Beam E
2-Mounting holes
C (Protective
height)
D53 42
5.5
7
22
31
30
16.5
2-Mounting holes
2-Top/bottom mounting brackets
5.5 20
20
30
3.75
6.25
(13.75)
B A
4-M5
22
2-M5
42
E
B
46
26
How to Calculate Your System Dimensions:
C (protective height) = 4-digit number in the table
A = C + 74
B = C + 46.5
D = C - 20
E = see chart below
Mounting Screw Holes
F3SJ-A Safety Light Curtains
D41
For the Latest Information
On the Internet: www.sti.com
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D
Ordering
The minimum components required for an F3SJ-A system are a emitter receiver set and a set of
single or double-ended connector cables. See the table below for an overview of the versions avail-
able. The pages which follow provide specific part numbers and accessory descriptions.
Safety Light Curtain F3SJ-A
Designator Protection Detection Beam Gap Operating Range No. of Beams Protective Height
F3SJ-A££££P141Finger 14 mm 9 mm 0.2 to 9 m (0.7 to 29.5 ft.) 26 to 197 245 to 1784 mm (9.6 to 70.2 in.)
F3SJ-A££££P201Finger/Hand 20 mm 15 mm 0.2 to 9 m (0.7 to 29.5 ft.) 16 to 100 245 to 1505 mm (9.6 to 59.3 in.)
F3SJ-A££££P201Finger/Hand 20 mm 15 mm 0.2 to 7 m (0.7 to 23.0 ft.) 110 to 166 1655 to 2495 mm (65.2 to 98.2 in.)
F3SJ-A££££P20-TS2Finger/Hand 20 mm 15 mm 0.2 to 9 m (0.7 to 29.5 ft.) 16 to 100 245 to 1505 mm (9.6 to 59.3 in.)
F3SJ-A££££P20-TS2Finger/Hand 20 mm 15 mm 0.2 to 7 m (0.7 to 23.0 ft.) 110 to 166 1655 to 2495 mm (65.2 to 98.2 in.)
F3SJ-A££££P251Hand 25 mm 20 mm 0.2 to 9 m (0.7 to 29.5 ft.) 13 to 79 260 to 1580 mm (10.2 to 62.2 in.)
F3SJ-A££££P251Hand 25 mm 20 mm 0.2 to 7 m (0.7 to 23.0 ft.) 87 to 125 1740 to 2500 mm (68.5 to 98.4 in.)
F3SJ-A££££P25-TS2Hand 25 mm 20 mm 0.2 to 9 m (0.7 to 29.5 ft.) 13 to 79 260 to 1580 mm (10.2 to 62.2 in.)
F3SJ-A££££P25-TS2Hand 25 mm 20 mm 0.2 to 7 m (0.7 to 23.0 ft.) 87 to 125 1740 to 2500 mm (68.5 to 98.4 in.)
F3SJ-A££££P301Hand/arm 30 mm 25 mm 0.2 to 9 m (0.7 to 29.5 ft.) 10 to 65 245 to 1620 mm (9.6 to 63.8 in.)
F3SJ-A££££P301Hand/arm 30 mm 25 mm 0.2 to 7 m (0.7 to 23.0 ft.) 70 to 100 1745 to 2495 mm (68.7 to 98.2 in.)
F3SJ-A££££P551Leg/body 55 mm 50 mm 0.2 to 9 m (0.7 to 29.5 ft.) 6 to 33 270 to 1620 mm (10.6 to 63.8 in.)
F3SJ-A££££P551Leg/body 55 mm 50 mm 0. 2 to 7 m (0.7 to 23.0 ft.) 36 to 50 1770 to 2470 mm (69.7 to 97.2 in.)
Notes: Connection cables are not included with the products and must be purchased separately as needed.
Specific Model Numbers
Model
No. of
Beams
Protective
Height
(mm)
F3SJ-A14 Series
F3SJ-A0245P14 26 245
F3SJ-A0263P14 28 263
F3SJ-A0299P14 32 299
F3SJ-A0317P14 34 317
F3SJ-A0389P14 42 389
F3SJ-A0425P14 46 425
F3SJ-A0461P14 50 461
F3SJ-A0533P14 58 533
F3SJ-A0551P14 60 551
F3SJ-A0605P14 66 605
F3SJ-A0623P14 68 623
F3SJ-A0695P14 76 695
F3SJ-A0731P14 80 731
F3SJ-A0767P14 84 767
F3SJ-A0803P14 88 803
F3SJ-A0875P14 96 875
F3SJ-A0911P14 100 911
F3SJ-A0983P14 108 983
F3SJ-A1055P14 116 1055
F3SJ-A1127P14 124 1127
F3SJ-A1199P14 132 1199
F3SJ-A1271P14 140 1271
F3SJ-A1487P14 164 1487
F3SJ-A1631P14 180 1631
F3SJ-A1784P14 197 1784
F3SJ-A20, F3SJ-A20-TS* Series
F3SJ-A0245P20 16 245
F3SJ-A0275P20 18 275
F3SJ-A0305P20 20 305
F3SJ-A0395P20 26 395
F3SJ-A0455P20 30 455
F3SJ-A0545P20 36 545
F3SJ-A0575P20 38 575
F3SJ-A0605P20 40 605
Model
No. of
Beams
Protective
Height
(mm)
F3SJ-A0635P20 42 635
F3SJ-A0665P20 44 665
F3SJ-A0695P20 46 695
F3SJ-A0755P20 50 755
F3SJ-A0785P20 52 785
F3SJ-A0815P20 54 815
F3SJ-A0875P20 58 875
F3SJ-A0905P20 60 905
F3SJ-A0935P20 62 935
F3SJ-A0965P20 64 965
F3SJ-A1025P20 68 1025
F3SJ-A1115P20 74 1115
F3SJ-A1205P20 80 1205
F3SJ-A1265P20 84 1265
F3SJ-A1445P20 96 1445
F3SJ-A1505P20 100 1505
F3SJ-A1655P20 110 1655
F3SJ-A1805P20 120 1805
F3SJ-A1955P20 130 1955
F3SJ-A2105P20 140 2105
F3SJ-A2255P20 150 2255
F3SJ-A2405P20 160 2405
F3SJ-A2495P20 166 2495
F3SJ-A25, F3SJ-A25-TS* Series
F3SJ-A0260P25 13 260
F3SJ-A0300P25 15 300
F3SJ-A0460P25 23 460
F3SJ-A0540P25 27 540
F3SJ-A0620P25 31 620
F3SJ-A0700P25 35 700
F3SJ-A0780P25 39 780
F3SJ-A0860P25 43 860
F3SJ-A0940P25 47 940
F3SJ-A1020P25 51 1020
F3SJ-A1100P25 55 1100
Model
No. of
Beams
Protective
Height
(mm)
F3SJ-A1180P25 59 1180
F3SJ-A1260P25 63 1260
F3SJ-A1420P25 71 1420
F3SJ-A1500P25 75 1500
F3SJ-A1580P25 79 1580
F3SJ-A1740P25 87 1740
F3SJ-A1900P25 95 1900
F3SJ-A2060P25 103 2060
F3SJ-A2220P25 111 2220
F3SJ-A2380P25 119 2380
F3SJ-A2420P25 121 2420
F3SJ-A2500P25 125 2500
F3SJ-A30 Series
F3SJ-A0245P30 10 245
F3SJ-A0295P30 12 295
F3SJ-A0320P30 13 320
F3SJ-A0395P30 16 395
F3SJ-A0470P30 19 470
F3SJ-A0520P30 21 520
F3SJ-A0545P30 22 545
F3SJ-A0570P30 23 570
F3SJ-A0620P30 25 620
F3SJ-A0695P30 28 695
F3SJ-A0720P30 29 720
F3SJ-A0770P30 31 770
F3SJ-A0795P30 32 795
F3SJ-A0820P30 33 820
F3SJ-A0870P30 35 870
F3SJ-A0920P30 37 920
F3SJ-A0945P30 38 945
F3SJ-A0995P30 40 995
F3SJ-A1020P30 41 1020
F3SJ-A1045P30 42 1045
F3SJ-A1095P30 44 1095
F3SJ-A1120P30 45 1120
Model
No. of
Beams
Protective
Height
(mm)
F3SJ-A1195P30 48 1195
F3SJ-A1220P30 49 1220
F3SJ-A1270P30 51 1270
F3SJ-A1395P30 56 1395
F3SJ-A1495P30 60 1495
F3SJ-A1620P30 65 1620
F3SJ-A1745P30 70 1745
F3SJ-A1820P30 73 1820
F3SJ-A1870P30 75 1870
F3SJ-A1995P30 80 1995
F3SJ-A2245P30 90 2245
F3SJ-A2370P30 95 2370
F3SJ-A2495P30 100 2495
F3SJ-A55 Series
F3SJ-A0270P55 6 270
F3SJ-A0320P55 7 320
F3SJ-A0370P55 8 370
F3SJ-A0420P55 9 420
F3SJ-A0470P55 10 470
F3SJ-A0570P55 12 570
F3SJ-A0620P55 13 620
F3SJ-A0720P55 15 720
F3SJ-A0770P55 16 770
F3SJ-A0870P55 18 870
F3SJ-A0920P55 19 920
F3SJ-A0970P55 20 970
F3SJ-A1020P55 21 1020
F3SJ-A1120P55 23 1120
F3SJ-A1170P55 24 1170
F3SJ-A1220P55 25 1220
F3SJ-A1270P55 26 1270
F3SJ-A1320P55 27 1320
F3SJ-A1420P55 29 1420
F3SJ-A1570P55 32 1570
F3SJ-A Safety Light Curtains
(Continued on next page)
= Highlighted Rapid Delivery products are available for shipment today or within THREE days.
Notes: Connection cables are not included with the products and must be purchased separately as needed.
* The suffix “-TS” is attached to the model number of models with fixed auto reset.
1
Models with S-mark certification have an “-S” at the end of the model number. S-mark certification is for equipment sold in South Korea. Example: F3SJ-A0245P14-S.
2
Models with fixed auto reset (-TS). Parameters cannot be set using the F39-MC21 Setting Console or F39-GWUM “SD Manager” Support Software for F3SJ-A.
For the Latest Information
On the Internet: www.sti.com
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D42
D
Model
No. of
Beams
Protective
Height
(mm)
F3SJ-A1620P55 33 1620
F3SJ-A1770P55 36 1770
F3SJ-A1920P55 39 1920
F3SJ-A2070P55 42 2070
F3SJ-A2220P55 45 2220
F3SJ-A2370P55 48 2370
F3SJ-A2470P55 50 2470
Ordering (continued)
F3SJ-A Safety Light Curtains
Accessories
Model Description
Single-End Connector Cable (2 cables per set, for emitter and receiver)
For wiring with safety circuit such as single safety relay, safety relay unit, and safety controller
F39-JC3A M12 connector (8-pin), 3 m (9.8 ft.)
F39-JC7A M12 connector (8-pin), 7 m (23.0 ft.)
F39-JC10A M12 connector (8-pin), 10 m (32.8 ft.)
F39-JC15A M12 connector (8-pin), 15 m (49.2 ft.)
F39-JC20A M12 connector (8-pin), 20 m (65.6 ft.)
Double-End Connector Cable (2 cables per set, for emitter and receiver) For connection with F3SP-
B1P control unit, and for extension when series-connected. Note: To extend the cable length under
series connection, use F39-JJR3W and F39-JC£B in combination.
F39-JCR5B M12 connector (8-pin), 0.5 m (1.6 ft.)
F39-JC1B M12 connector (8-pin), 1 m (3.3 ft.)
F39-JC3B M12 connector (8-pin), 3 m (9.8 ft.)
F39-JC5B M12 connector (8-pin), 5 m (16.4 ft.)
F39-JC7B M12 connector (8-pin), 7 m (23.0 ft.)
F39-JC10B M12 connector (8-pin), 10 m (32.8 ft.)
F39-JC15B M12 connector (8-pin), 15 m (49.2 ft.)
F39-JC20B M12 connector (8-pin), 20 m (65.6 ft.)
Series Connection Cable (2 cables per set, for emitter and receiver)
F39-JJR3W Series connection cable3 or when using water-resistant case4, 0.3 m (1.0 ft.)
F39-JC£B Extension cable, 0.5 to 15 m (1.6 to 49.2 ft.)
To change series connection length in combination with F39-JJR3W
F39-JJR06L Side-by-side series connection cable, 0.06 m (2.4 in.) Dedicated series connection
cable with minimum length, used in place of the sensor’s cable with connector
F39-JJR15L Side-by-side series connection cable, 0.15 m (5.9 in.) Dedicated series connection
cable with minimum length, used in place of the sensor’s cable with connector
Sensor Mounting Brackets (spare parts)
F39-LJ1 Standard mounting bracket (for top/bottom), included with F3SJ system,
2 for emitter and 2 for receiver (total of 4 per set)
F39-LJ2 Flat side mounting bracket, Use these small-sized brackets when performing side
mounting with standard mounting brackets so that they do not protrude from the
detection surface, 2 for emitter and 2 for receiver (total of 4 per set)
F39-LJ3 Free-location mounting bracket (also used as standard intermediate bracket), Use
these brackets for mounting any place without using standard bracket, 1 set with 2
pieces
Key Cap for Muting
F39-CN6 Cap attaches to the main unit to enable muting function, attach to either an emitter or
a receiver, orange case
Setting Tools5
F39-GWUM SD Manager Software Accessories:
SD Manager CD-ROM, F39-CN1 Branch Connector, Connector Cap, 2 m Dedicated
Cable, 0.3 m Dedicated Cable with Plug, Instruction Manual
F39-MC21 Setting Console Accessories:
F39-CN1 Branch Connector, Connector Cap, 2 m Dedicated Cable,
0.3 m Dedicated Cable with Plug, Instruction Manual
F39-JC2M Spare cable for F39-GWUM and F39-MC21
3 Total cable length of series connection is 0.6 m to connect to connector cable of the main sensor unit.
For series connection with minimum length, use the F39-JJR06L or F39-JJR15L.
4 When using the F39-EJ££££-L/D water-resistant case in series connection configurations, use the
special series connection cables for the water-resistant case.
= Highlighted Rapid Delivery products are available for shipment today or within THREE days.
(Continued on next page)
For information on safety light
curtain accessories, see page D74.
For information on Resource
Modules, see page D59.
F39-JC7A
F39-JC15B
F39-JJR06L
F39-JJR15L
F39-JJR3W
F39-CN6
F39-LJ1 F39-LJ2
F39-LJ3
D43
For the Latest Information
On the Internet: www.sti.com
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D
Accessories (continued)
Model Description
Setting Tools5
F39-GWUM SD Manager Software Accessories:
SD Manager CD-ROM, F39-CN1 Branch Connector, Connector Cap, 2 m
Dedicated Cable, 0.3 m Dedicated Cable with Plug, Instruction Manual
F39-MC21 Setting Console Accessories:
F39-CN1 Branch Connector, Connector Cap, 2 m Dedicated Cable,
0.3 m Dedicated Cable with Plug, Instruction Manual
F39-JC2M Spare cable for F39-GWUM and F39-MC21
Control Unit
F3SP-B1P Relay, 3 N.O. + 1 N.C. output, for connection with F3SJ-A, use an F39-
JC£B double-end connector cable
Force-Guided Relays
G7SA-2A2B 4 contacts, 2 N.O. + 2 N.C., Rated switch load: 250 VAC 6 A, 30 VDC 6 A
G7SA-3A1B 4 contacts, 3 N.O. + 1 N.C., Rated switch load: 250 VAC 6 A, 30 VDC 6 A
G7S-4A2B-E 6 contacts, 4 N.O. + 2 N.C., Rated switch load: 250 VAC 10 A, 30 VDC 10 A
G7S-3A3B-E
6 contacts, 3 N.O. + 3 N.O., Rated switch load: 250 VAC 10 A, 30 VDC 10 A
Dedicated External Indicator Set (Can be connected to either an emitter or a receiver)
F39-A01PR-PAC Indicator (red), mounting bracket (1 set), and dedicated connection cable
(0.1 m)
F39-A01PG-PAC Indicator (green), mounting bracket (1 set), and dedicated connection cable
(0.1 m)
F39-A01PY-PAC Indicator (yellow), mounting bracket (1 set), and dedicated connection
cable (0.1 m)
General External Indicator Cable
F39-JJ3N Cable to connect top of the main unit and an off-the-shelf external indicator
(2-wire), 3 m (9.8 ft.)
Spatter Protection Cover
F39-HJ££££ For F3SJ-A series sensor, reduces operating range by 10%, includes two
pieces for emitter and receiver
Water-Resistant Case (Set of 1 tube, packing, and dedicated connector cable)
When using for both emitter and receiver, order two sets.
F39-EJ££££-L Water-resistant case for emitter, includes gray cable for emitter
F39-EJ££££-D Water-resistant case for receiver, includes black cable for receiver
F39-EJ-R6Rear mounting brackets, top/bottom 1 each, total of 2
F39-EJ-S6Side mounting brackets, top/bottom 1 each, total of 2
F39-JJR3WE-L Series connection cable for emitter, purchase additionally for series
connection when using the water-resistant case
F39-JJR3WE-D Series connection cable for receiver, purchase additionally for series
connection when using the water-resistant case
Branch Connector for F3SX (F39-JC£T to F39-JC£B)
F39-CN5 Branch connector for F3SX
Wire-Saving Devices
F39-CN8 Short-circuit connector
F39-TC5P01 Connector terminal box with muting sensor output mode (PNP)
F39-TC5P02 Connector terminal box with override mode (PNP)
F39-TC5N01 Connector terminal box with muting sensor output mode (NPN)
F39-TC5N02 Connector terminal box with override mode (NPN)
F3SP-T01 Safety terminal relays for F3SJ-A_-P_
Laser Alignment Tool
F39-PTJ Laser alignment tool for the F3SJ
Ordering (continued)
F3SJ-A Safety Light Curtains
= Highlighted Rapid Delivery products are available for shipment today or within THREE days.
F3SP-B1P
F39-A01-PR-PAC
F39-HJ££££
F39-JJ3N
F39-EJ££££-L/D
F39-EJ-R
F39-EJ-S
G7SA
G7S
F39-TC5
F39-CN5
F3SP-T01
F39-PTJ
5 The setting tools described above can be connected only to F3SJ-A models with built-in software of
Ver. 2 or later. Note that the setting tools cannot be used with products shipped prior to December 2005.
The setting tools cannot be used for setting parameters on the F3SJ-A£-TS series, but the monitoring
function can be used.
6 Be sure to purchase brackets with the case to match the mounting direction (rear or side).
F39-GWUM
F39-MC21