RECOMMENDED OPERATING CONDITIONS
Symbol Parameter Value Unit
VCC Supply Voltage 2 to 6 V
VIInput Voltage 0 to VCC V
VOOutput Voltage 0 to VCC V
Top Operating Temperature: M54HC Series
M74HC Series -55 to +125
-40 to +85
oC
oC
tr,t
fInput Rise and Fall Time VCC = 2 V 0 to 1000 ns
VCC = 4.5 V 0 to 500
VCC = 6 V 0 to 400
ABSOLUTE MAXIMUM RATINGS
Symbol Parameter Value Unit
VCC Supply Voltage -0.5 to +7 V
VIDC Input Voltage -0.5 to VCC + 0.5 V
VODC Output Voltage -0.5 to VCC + 0.5 V
IIK DC Input Diode Current ±20 mA
IOK DC Output Diode Current ±20 mA
IODC Output Source Sink Current Per Output Pin ±25 mA
ICC or IGND DC VCC or Ground Current ±50 mA
PDPower Dissipation 500 (*) mW
Tstg Storage Temperature -65 to +150 oC
TLLead Temperature (10 sec) 300 oC
AbsoluteMaximumRatingsarethose values beyond whichdamage tothedevicemayoccur. Functional operation under these conditionisnotimplied.
(*) 500 mW: ≅65oC derate to 300 mWby 10mW/oC: 65 oCto85o
C
M54/M74HC74
3/11