www.recom-power.com REV.: 0/2018 P-1
Description
The R-78S3.3-0.1-EVM-1/SBL-1 is a breakout board developed to be used with a SensiBLE v1.0 (1)
module from SensiEDGE and the R-78S3.3-0.1-EVM-1 evaluation module to demonstrate IoT appli-
cations using the SensiBLE v1.0 module. Functions of the SensiBLE v1.0 module include 3-axis ac-
celerometer, 3-axis magnetometer, 3-axis digital gyroscope, pressure, microphone, relative humidity,
ambient light and temperature sensors. SensiBLE v1.0 contains an on-board coin battery which must
be removed prior to connecting to the R-78S3.3-0.1-EVM-1/SBL-1. When supplied by R-78S3.3-0.1-
EVM-1 with a AA battery, operation lifetime increases dramatically.
Features
Evaluation
Module
Accessory
Accessory for the
R-78S3.3-0.1-EVM-1
Mates with SensiBLE v1.0
Evaluation Module
Accessory
R-78S3.3-0.1-EVM-1/SBL-1
Notes:
Note1: The SensiBLE v1.0 module from SensiEDGE is not provided by RECOM
Quick Start Guide
Insert the AA battery into the battery holder.
Ensure that the coin battery is removed from the SensiBLE v1.0 module.
Insert the SensiBLE v1.0 module onto the R-78S3.3-0.1-EVM-1/SBL-1, and plug into header J7
(refer to pictures for correct orientation).
Turn on using the switch on the R-78S3.3-0.1-EVM-1 (Note: to reduce the power consumption,
no indicator LED is fitted). Remember to switch off to conserve the battery.
To connect with the SensiBLE v1.0 module, download and install the ST BlueMS App on your mobile
phone and touch “START SCANNING”.
This breakout board only connects to the power terminals of the SensiBLE v1.0 module.
Communication is via Bluetooth (App available).
CN2-pin 1 is connected to GND.
CN3-pin 1 is connected to VDDUSB (with connection to R-78S3.3-0.1-EVM-1 it is 3.3V).
All the other pins are not connected and serve only as mechanical connections.
www.recom-power.com/eval-ref-boards
Layout
CN2
CN1
CN4
CN3
FOR EVALUATION ONLY
BUTTON ON
THIS SIDE
R-78S3.3-0.1-EVM-1/SBL-1
30mm
20mm
30mm
24.5mm
www.recom-power.com REV.: 0/2018 P-2
Schematic
I
H
G
F
E
D
C
B
A
7
6
5
4
3
2
1
A
B
C
D
E
F
G
H
I
2
3
4
5
6
7
1
NAME
RECOM Engineering GmbH & CO KG
SCHEMATIC DIAGRAM TITLE
/
DATE
SIGNATURE
VERSION
FILENAME
Approver
Münzfeld 35 A-4810 Gmunden
PAGE NO.
Maria Mystica Alcantara
Designer
GND
VDDUSB
1
CN2-A
2
CN3-B
1
CN4-A
1
FD3
1
FD2
1
FD1
1
2
CN1
SSW-102-02-T-S-RA
2
CN2-B
1
CN3-A
2
CN4-B
Stanislav Suchovsky
15.09.2017
R-78S3.3-0.1-EVM-1_SBL-1
15.09.2017
01
R-78S3.3-0.1-EVM-1_SBL-1.scm
1 1
R-78S3.3-0.1 EVM-1/SBL-1
The
product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products
are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss
of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.
Assembled R-78S3.3-0.1-EVM-1/SBL-1 on the R-78S3.3-0.1-EVM-1
R-78S3.3-0.1-EVM-1/SBL-1 with the SensiBLE v1.0 module
Evaluation Module