AC-DC
Specification
250/350 Watts
•200 W / 300 W with Convection Cooling
•High Efficiency - up to 88%
•Meets 1U, Low Profile Requirements
•AC OK & DC OK Signals
•Zero Voltage Switching Technology
•Remote On/Off & Remote Sense
•3 Year Warranty
JPS250/350 Series
Input
Input Voltage • 85-264 VAC (170-370 VDC)
Input Frequency • 47-63 Hz
Input Current • 2.75 A/1.40 A max at 115 VAC/ 230 VAC (JPS250)
4.5 A/2.2 A max at 115 VAC/230 VAC (JPS350)
Inrush Current • 30 A at 115 VAC, 60 A at 230 VAC
Power Factor • 0.9 typical
Earth Leakage Current • 3.0 mA max 264 VAC/60 Hz
Input Protection • Internal T5 A, 250 VAC fuse (JPS250)
Internal T6.3 A, 250 VAC fuse (JPS350)
Output
Output Voltage • See tables
Output Voltage Trim • ±10% on output 1 only (VR1)
Initial Set Accuracy • At 60% rated load ±1% on V1 & V2,
±5% on V3 & V4
Minimum Load • Single output models: No minimum load
required. Multi-output models, see note 4
Start Up Delay • 2 s typical
Start Up Rise Time • 80 ms typical (JPS250)
100 ms typical (JPS350)
Hold Up Time • 20 ms min at low line & rated load
Line Regulation • ±0.5% at rated load across input voltage range
Load Regulation • ±1% for single output models & V1 & V2 of
multi-output models, ±5% for V3 & V4
Transient Response • 4% max deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise • ±1% max pk-pk, 15 MHz bandwidth,
see note 2 under model tables
Overvoltage Protection • 115-140% on single outputs & V1 of quad
output models, recycle input to reset
Overtemperature • Shuts down at +110 °C, auto recovery,
Protection measured internally
Overload Protection • 110-130% of max rated load on all O/Ps,
auto recovery
Short Circuit Protection • Trip and restart (Hiccup mode), auto recovery
Temp. Coefficient • ±0.05%/°C
Remote Sense • Compensates for up to 0.5 V drop
Remote On/Off • On = Logic Low or Open, Off = Logic High
Current Share • Current share on single output models & V1
& V2 of multi-output models (4 supplies can
be paralleled)
Fan Output • See mechanical notes for ordering information
xppower.com
General
Efficiency • Up to 88%
Isolation • 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
Switching Frequency • 120 kHz typical for PFC and PWM
Power Density • 4.96 W/In3
Signals • AC OK, DC OK, Remote On/Off
(see control and supervisory signals)
MTBF • 125 kHrs to MIL-HDBK-217F
at +50 °C, GB (JPS250)
146 kHrs to MIL-HDBK-217F
at +50 °C, GB (JPS350)
Environmental
Operating Temperature • 0 °C to +70 °C, (see derating curve)
Full power to +50 °C
Cooling • 250 W with 18 CFM airflow (JPS250)
200 W convection cooling (JPS250)
350 W with 18 CFM airflow (JPS350)
300 W convection cooling (JPS350)
Operating Humidity • 5-95% RH, non-condensing
Storage Temperature • -20 °C to +85 °C
Operating Altitude • 2000 m
Vibration • 2 g, 10 Hz to 55 Hz, 30 mins each axis
EMC & Safety
Emissions • EN55022, level B conducted
FCC 20780, level B conducted
Harmonic Currents • EN61000-3-2
ESD Immunity • EN61000-4-2, level 3 Perf Criteria A
Radiated Immunity • EN61000-4-3, 10 V/m Perf Criteria A
EFT/Burst • EN61000-4-4, level 3 Perf Criteria A
Surge • EN61000-4-5, level 3 Perf Criteria A
Dips and Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
Safety Approvals • EN60950-1, UL60950-1,
CSA C22.2 No. 60950-1, CE Mark LVD