DIN Rail Mount DataSheet SeriesOne DR Series ATEX DC AC * Ratings of 6 & 12 Amps * Load voltage ratings of 1-60VDC, 1-100VDC, 24-280VAC and 48-600VAC * Fits standard 35mm DIN Rail * LED input status indicator * AC or DC control * Zero Voltage (resistive loads) or Instantaneous (inductive loads) turn-on output * UL and cUL Listed, HP Rated CE & RoHS Compliant * UL 508 Endurance Rating for Enhanced Reliability * UL Class I and II, Division 2, for Hazardous Locations PRODUCT SELECTION Control Voltage 280, 6 A 280 V, 12 A 600 V, 6 A 600 V, 12 A 60 V, 6 A 60 V, 12 A 100 V, 6 A 100 V, 12 A 4-32 VDC 90-140 VAC 200-280 VAC 18-36 VAC DR24D06X DR24B06X DR24A06X DR24E06X DR24D12X DR24B12X DR24A12X DR24E12X DR48D06X DR48D12X DR48B12X DR48A12X DR48E12X DR06D06X DR06D12X DR10D06X DR10D12X AVAILABLE OPTIONS Series DR Operating Voltage 06: 1-60 VDC 10: 1-100 VDC 24: 24-280 VAC 48: 48-600 VAC 06 D Rated Load Current 06: 6 Amps 12: 12 Amps 12 X Switching Type Blank: Zero Voltage Turn-On (AC Output Only) R: Instantaneous Turn-On (AC Output, D suffix Only) R Control Voltage Agency Approvals D: 4-32 VDC X: ATEX II 3G Ex nA IIC T4 Gc A: 200-265 VAC approved AC Output B: 90-140 VAC Only E: 18-36 VAC (1) Required for valid part number For options only and not required for valid part number OUTPUT SPECIFICATIONS AC Output (2) Description DR24x06X DR24x12X DR48x06X DR48X12X Operating Voltage Range (47-63Hz) [Vrms] Transient Overvoltage [Vpk] Maximum Load Current, resistive [Arms] (3) Minimum Load Current [mArms] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/sec] (4) Maximum On-State Voltage Drop @ Rated Current [Vrms] Maximum Surge Current (50/60Hz, 1 cycle) [Apk] Maximum It for Fusing (50/60 Hz, 1/2 cycle) [A sec] HP Rating UL 508/IEC60947 [HP (KW)] @ 240V HP Rating UL 508/IEC60947 [HP (KW)] @ 380V HP Rating UL 508/IEC60947 [HP (KW)] @ 480V Minimum Power Factor (at Maximum Load) Min/Max stranded wire Min/Max solid wire Weight (Typical) 24-280 600 6 150 0.1 500 1.3 285/300 400/375 1/2 (.37) N/A N/A 0.5 22/14 AWG 22/14 AWG 1.76 oz. (50g) 24-280 600 12 150 0.1 500 1.3 715/750 2560/2330 1 (.75) N/A N/A 0.5 22/14 AWG 22/14 AWG 3.17 oz. (90g) 48-600 1200 6 150 0.1 500 1.3 285/300 410/375 1/2 (.37) 1 (1.5) 2 (1.5) 0.5 22/14 AWG 22/14 AWG 1.76 oz. (50g) 48-600 1200 12 150 0.1 500 1.3 715/750 2560/2330 1 (.75) 2 (1.5) 3 (2.2) 0.5 22/14 AWG 22/14 AWG 3.17 oz. (90g) Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. DIN Rail Mount DataSheet OUTPUT SPECIFICATIONS DC Output (2) Description DR06D06X DR10D06X DR06D12X DR10D12X Operating Voltage [VDC] Maximum Load Current [Adc] (3) Minimum Load Current [mAdc] Maximum Off-State Leakage Current @ Rated Voltage [mA] Maximum On-State Voltage Drop @ Rated Current [Vpk] Maximum Surge Current (10ms) [Apk] On-State resistance at rated current [Ohms] Min/Max stranded wire Min/Max solid wire Weight (typical) 1-60 6 2.5 0.1 0.6 60 0.1 22/14 AWG 22/14 AWG 1.94 oz. (55g) 1-100 6 2.5 0.1 0.6 60 0.1 22/14 AWG 22/14 AWG 1.76 oz. (50g) 1-60 12 2.5 0.1 0.6 100 0.45 22/14 AWG 22/14 AWG 3.17 oz (90g) 1-100 12 2.5 0.1 0.6 100 0.45 22/14 AWG 22/14 AWG 3.17 oz.(90g) INPUT SPECIFICATIONS (2) Description Control Voltage Range (5) Minimum Turn-On Voltage Must Turn-Off Voltage Minimum Input Current for [mA] (6) Maximum Input Current for [mA] (6) Maximum Turn-on Time [msec] (7) (8) Maximum Turn-off Time [msec] (9) Min/Max stranded/solid wire DRxxDxxX DRxxBxxX 4-32 VDC 4.0 VDC 1.0 VDC 9 11 1/2 Cycle 1/2 Cycle 22/16 AWG 90-140 Vrms 90 Vrms 10 Vrms 3 5 20 msec 30 msec 22/16 AWG GENERAL SPECIFICATIONS (2) Description Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 VDC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Recommended Terminal Screw Torque Range DRxxAxxX DRxxExxX 200-265 Vrms 200 Vrms 40 Vrms 2.5 3.3 20 msec 30 msec 22/16 AWG Parameters 4000 Vrms (10) 109 Ohm 10 pF -20 to 40 C -30 to 100 C 4.4-7.0 in-lb (0.5-0.8Nm) GENERAL NOTES (1) E option is UL certified for AC control voltage, but it works also with 18-36 VDC input range. (2) All parameters at 25C unless otherwise specified. (3) See Derating curves (4) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (5) DC control includes reverse polarity protection. (6) Input circuitry incorporates active current limiter. (7) Turn-on time for DC control random turn-on versions is 0.1 msec. (8) Turn-on time for DC output 600sec. (9) Turn-off time for DC output 300sec. (10) 2500Vrms for DC output. Standards of Compliance IEC 62314 LC A, Resistive or Slightly Inductive Load Ratings: 12 A @40C ambient for DR24x12X, 12 A @ 40C ambient for DR48x12X LC A, Resistive or Slightly Inductive Load Ratings: 6 A @ 40C ambient for DR24x06X, 6 A @ 40C ambient for DR48x06X LC B, Motor Loads Ratings: 0.75KW @ 240 VAC for DR24x06X and 2.2KW @ 480 VAC DR48x12X LC B, Motor Loads Ratings: 0.375KW @ 240 VAC for DR24x06X and 1.5KW @ 480 VAC DR48x12X Shock and Vibration (Applies to all part numbers) Vibration Resistence according to IEC 60068-2-6: 0.35mm and 0.75mm Amplitude over 10-55 Hz Shock Resistance according to IEC 60068-2-27: 15g/11ms EMC (Applies to all part numbers) IEC 61000-4-2: Electrostatic Discharge- Level 3 IEC 61000-4-4: Electrically Fast Transients- Level 3 IEC 61000-4-5: Electrical Surges- Level 3 ANSI / ISA 12.12.01-2013 Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazadous (classified) locations This equipment is open-type device and is meant to be installed in an enclosure suitable for the enviroment such that the equipment is only accesible with the use of a tool suitable for use in Class 1, Division 2, Group A,B,C and Hazardous locations, or Nonhazardous locations only WARNING-Explosion Hazard- Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations WARNING-Explosion Hazard- Substitution of any component may impair suitability for Class I, Division 2 ATEX Compliance with Essential Health and Safety Requirements has been assessed by reference to Standards EN 60079-0:2012+A11:2013 and EN 60079-15-:2010 Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. 18-36 Vrms (1) 18 Vrms 4 Vrms 3.5 8 20 msec 30 msec 22/16 AWG DIN Rail Mount DataSheet MECHANICAL SPECIFICATIONS (2) EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAMS Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. DIN Rail Mount DataSheet THERMAL DERATE INFORMATION Derating Curves are not approved for the ATEX Certification DRxxx06X 6 Load Current (Amps) 5 4 3 2 1 0 0 10 20 30 40 50 60 70 80 60 70 80 Ambient Temperature (C) DRxxx12X 12 Load Current (Amps) 10 8 6 4 2 0 0 10 20 30 40 50 Ambient Temperature (C) Installed single unit, distance to adjacent components 11 mm for DRxxx06X & 18mm for DRxxx12X Multiple units, no minimum spacing between components AGENCY APPROVALS Agency Approvals IND. CONT. EQ. 4WB8 E364559 II 3G Ex nA IIC T4 Gc Rev 052516 Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. DIN Rail Mount DataSheet ACCESORIES Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. DIN Rail Mount DataSheet DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH. * Disconnect all power before installing or working with this equipment. * Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION. * Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo. * Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION * Eteindre toutes les sources d'energie de cet appareil avant de travailler dessus de cet appareil * Verifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lesions serieuses serieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION. * Stellen Sie jeglichen Strom ab, der dieses Gerat versorgt, bevor Sie an dem Gerat Arbeiten durchfuhren * Vor dem Drehen auf Energie alle Anschlusse uberprufen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen konnen zum Tode oder zu schweren Verletzungen fuhren. RISCHIO DI SCOSSA ELETTRICA O DELL'ESPLOSIONE. * Spenga tutta l'alimentazione che fornisce questa apparecchiatura prima di lavorare a questa apparecchiatura * * Verificare tutti i collegamenti e sostituire tutte le coperture prima dell'accensione L'omissione di queste istruzioni provochera la morte o lesioni serie WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER GEFAHR VON MATERIALSCHADEN UND GEHAUSEERHITZUNG * The product's side panels may be hot, allow the product to cool before touching. * Follow proper mounting instructions including torque values. * Do not allow liquids or foreign objects to enter this product. * Les panneaux lateraux du produit peuvent etre chauds. Laisser le produit refroidir avant de le toucher. * Respecter les consignes de montage, et notamment les couples de serrage. * Ne pas laisser penetrer de liquide ni de corps etrangers a l'interieur du produit. * Die Seitenwande konnen hei sein. Lassen Sie das Produkt abkuhlen, bevor Sie es beruhren. * Beachten Sie die Montageanweisungen, * Fuhren Sie keine Flussigkeiten oder Fremdkorper in das Produkt ein. Le non-respect de cette directive peut entrainer, Failure to follow these instructions can result in des lesions corporelles graves ou des serious injury, or equipment damage. dommages materiels. Die Nichtbeachtung dieser Anweisung kann Korperverletzung oder Materialschaden zur Folge haben. RIESGO DE DANOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO * Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfrie antes de tocarlo. * Respetar las instrucciones de montaje, y en particular los pares de apretado. * No dejar que penetren liquidos o cuerpos extranos en el producto. * I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo. * Seguire le istruzioni di montaggio corrette. * Non far entrare liquidi o oggetti estranei in questo apparecchio. Si no se respetan estas precauciones pueden producirse graves lesiones, danos materiales. La mancata osservanza di questa precauzione puo causare gravi rischi per l'incolumita personale o danni alle apparecchiature. Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. * * * DIN Rail Mount DataSheet ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People's Republic of China Electronic Industry Standard SJ/T11364 - 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr (VI)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) Semiconductor die Solder - SJ/T11364 - 2006, (Pb) (Hg) (Cd) (Cr (VI)) 50 Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. (PBB) (PBDE)