AC-DC 60Watts VCTSeries xppower.com * Low Cost * Single Outputs from 5 V to 30 V * Peak Load Capability * Convection-cooled * <0.5 W No Load Input Power * 2"x 4"Package * Fits 1U Applications B R A N D Specification Input General * 85-264 VAC * 47-63 Hz * 1.7 A max at 115 VAC, 0.85 A max at 230 VAC Inrush Current * 80 A typ. at 230 VAC, cold start at 25 C Earth Leakage Current * 500 A at 264 VAC / 60 Hz Power Factor * EN61000-3-2, class A No Load Input Power * <0.5 W Input Protection * Internal T3.15A/250 V fuse in line Input Voltage Input Frequency Input Current Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response * * * * * * * * * * Ripple & Noise Overvoltage Protection Overload Protection Short Circuit Protection Temperature Coefficient * * * * * See table None 2% at 50 % load No minimum load requirement 2 s max 8 ms typical 8 ms typical at full load and 115 VAC 0.5% max 1.0% max (see note 1) 4% maximum deviation, recovering to less than 1% within 500 s for 50% step load 1% max pk-pk (see note 2) See table 133-166% Trip and restart (hiccup mode) 0.02% / C Efficiency Isolation Switching Frequency MTBF * See table * 3000 VAC Input to Output 1500 VAC Input to Ground 500 VDC Output to Ground * 60 kHz 10 kHz * >700 kHrs to Bell Core iss. 6 Environmental Operating Temperature * -10 C to +70 C derate from 100% load at 50 C to 50% load at 70 C Cooling * Natural convection Operating Humidity * 5% to 90% RH, non condensing Operating Altitude * 3000 m Storage Temperature * -20 C to +85 C Shock * IEC68-2-6, 30 g, 11 mins half sine, 3 times in each of 6 axes Vibration * IEC68-2-27, 10-500Hz, 2 g 10 mins / sweep. 60 mins for each of 3 axes EMC&Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals * * * * * * * EN55022, level B conducted & radiated EN61000-3-2 class A EN61000-3-3 EN61000-4-2, level 3, Perf Criteria A EN61000-4-3, 10 V/m, Perf Criteria A EN61000-4-4, level 3, Perf Criteria A EN61000-4-5, installation class 3, Perf Criteria A * EN61000-4-6, 10 V, Perf Criteria A * EN61000-4-11, 30% 10 ms, 60%, 100 ms, 100%, 5000 ms Perf Criteria A, B, B * UL60950-1, IEC60950-1, EN60950-1 Output Current Output Voltage(6) Nominal 8.00 A 5.00 A 4.00 A 2.50 A 5.0 V 12.0 V 15.0 V 24.0 V Peak(3) 10.0 A 6.3 A 5.0 A 3.1 A OVP Setting(5) Efficiency(4) Model Number 7.0 V 13.0 V 17.0 V 29.0 V 82% 87% 87% 88% VCT40US05 VCT60US12 VCT60US15 VCT60US24 Notes 1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% 40% full load). 2. Measured at the output connector with a 0.1 F ceramic capacitor and a 10 F electrolytic capacitor. 3. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal. 4. Average of efficiencies measured at 25%, 50%, 75% & 100% load and 230 VAC input. 5. Typical trip point. 6. Other voltages between 5 V and 30 V available on request, contact sales for details. MechanicalDetails 3.75 (95.3) 0.06 (1.6) PCB Thickness 0.12 (3.2) 2 1 1.75 (44.5) 2.0 (50.8) 1 4 0.09 (2.5) Lead Length 0.12 (3.1) O0.13 (3.5)-4 Places Output Connector 0.78 (20.0) 0.94 (24.1) 1 +Vout 2 +Vout 3 -Vout 4 -Vout Mates with: Molex Housing 09-50-3041 and Molex Series 2878 crimp terminals. Pin 1 Pin 2 4.0 (101.6) Input Connector Neutral Live Mates with: Molex Housing 09-50-3031 and Molex Series 2878 crimp terminals. Mounting holes marked with must be connected to safety earth Notes 1. All dimensions shown in inches (mm). 2. Weight 0.29 lbs (130 g) approx 3. Tolerance: x.xx = 0.04 (x.x = 0.1); x.xxx = 0.2 (x.xx = 0.5) 16-Aug-16 AC-DC VCT60 ModelsandRatings