Differential Phase Shift Circulators 3.00 Features Mechanical Outline @ WR-284 TO WR-28 Standard Mating Flanges Description The differential phase shift circulators shown represent only a sampling of M/A-COMs product capability. Consult the factory for custom options such as direction of circulation, RFI shielding, magnetic shielding, frequen- cy ranges, etc.. Specifications Isolation Insertion Power Frequency Mating (dB.) Loss VSWR | Peak | Avg? COOL Length Circulator Waveguide (GHz) Flange 1-3 | 2-1 (dB Max.)| Max. (kW) (W) Type Inches Model No. WR-284 2.7-2.9 CPR-284G 25 20 04 1.20 1000 | 5000 CONV | 25.90 8H132-104 WR-284 27-29 CPR-284G 25 20 0.4 1.20 500 10000} LIQ 27.30 8H145-104 WR-284 2.7-2.9 GPR-284F 25 20 04 1.20 3000 | 20000} LIQ 38.80 8H150-101 WR-284 2.9-3.1 GPR-284G 25 20 04 1.20 500 10000] LIQ 27.30 8H145-102 WR-284 2.9-3.1 GPR-284F 25 20 04 1.20 3000 | 20000} LIQ 38.80 8H150-102 WR-284 3.1-3.5 GPR-284G 25 20 04 1.20 500 10000] LIQ 27.30 8H145-103 WR-284 3.1-3.5 GPR-284F 25 20 04 1.20 3000 | 20000} LIQ 38.80 8H150-103 Notes 1. Peak power handling capability will depend on pressurization, duty cycle, pulsewidth, load mismatch and altitude. 2. Average power handling capability may be increased by heat sinking, fins or liquid cooling. 3. High power circulators may be built with a load at port 4 for a duplexer function or loads at ports 3 and 4 for an isolator application. Reflected power into load must be specified. Specifications Subject to Change Without Notice. M/A-COM, Inc. 1 North America: Tel. (800) 366-2266 m Asia/Pacific: Tel. +81 (03) 3226-1671 m Europe: Tel. +44 (1344) 869 595 Fax (800) 618-8883 Fax +81 (03) 3226-1451 Fax +44 (1344) 300 020 Differential Phase Shift Circulators V3.00 Specifications Isolation Insertion Power Frequency Mating (dB.) Loss VSWR | Peak? | Avg? COOL Length | Circulator Waveguide (GHz) Flange 1-3 | 2-1 (dB Max.) | Max. (kW) (Ww) Type Inches Model No. WR-187 44-5.0 UG-148C 25 20 05 1.20 300 3000 CONV | 22.00 8H24-101 WR-187 4.4-5.0 UG-148C 25 20 o4 1.20 5000 | 5000 CONV | 25.50 8H25-101 WR-187 445.0 UG-148C 25 20 04 1.20 400 10000} LIQ 25.50 8H183-101 WR-187 5.45.9 UG-148C 25 20 05 1.15 300 3000 CONV | 22.00 8H24-102 WR-187 .4-5.9 UG-148C 25 20 0.4 1.15 5000 | 5000 CONV | 25.50 8H25-102 WR-187 5.45.9 UG-148C 25 20 04 1.15 4000 10000 | LIQ 25.50 8H183-102 WR-159 5.85-6.425 | CPR159F 23 20 0.2 1.10 CWO 15000 | AIR 25.25 8H156-101 WR-137 5.9-6.4 GPR137F 25 20 0.25 1.15 50 1500 GONV | 17.50 8H35-101 WR-112 7.5-8.5 UG-138 25 20 0.4 1.15 350 1000 GONV | 14.25 8H41-101 WR-112 8.0-8.5 UG138 25 20 0.4 1.15 350 1000 GONV | 14.25 8H41-102 WR-112 8.5-9.6 UG-138 25 20 04 1.15 350 1000 CONV | 11.62 8H51-101 WR-112 8.5-9.6 UG-138 25 20 0.3 1.15 10 3000 AIR 12.09 8H42-101 WR-112 8.5-9.6 UG-52B 25 20 04 1.15 1200 1500 LIQ 11.50 8H58-101 WR-112 9.0-10.0 UG-138 25 20 0.4 1.20 350 1000 CONV | 11.62 8H51-103 WR-90 8.5-9.6 UG-135 25 20 04 1.15 300 500 CONV | 850 8H62-101 WR-90 8.5-9.6 UG-136 25 20 0.25 1.15 30 2500 CONV | 12.00 8H157-101 WR-90 8.5-9.6 UG-40B 25 20 0.4 1.15 250 5000 LIQ 11.85 8H176-101 WR-90 8.5-9.6 UG-136 25 20 0.25 1.15 250 10000) LIQ 17.00 8H184-101 WR-90 9.0-10.0 UG-135 25 20 0.4 1.20 300 500 CONV | 8.50 8H62-102 WR-90 9.0-10.0 UG-136 25 20 0.3 1.20 30 2500 CONV | 12.00 8H157-102 WR-90 9.0-10.0 UG-40B 25 6) 0.4 1.20 250 5000 LIQ 11.85 8H176-102 WR-90 9.0-10.0 UG-136 25 20 0.3 1.20 250 10000 | LIQ 17.00 8H184-102 WR-75 12.0-12.5 CPR-75F 25 20 0.3 1.15 10 3000 AIR 10.00 8H159-101 WR-75 14.0-14.5 CPR-75F 25 20 0.25 1.10 10 3000 AIR 10.00 8H159-102 WR-62 13.5-15.5 UG-1666 25 20 0.4 1.20 200 400 CONV | 6.66 8H83-101 WR-62 13.5-15.5 UG-1666 25 20 0.3 1.20 10 2500 AIR 9.50 8H185-101 WR-62 15.5-17.5 UG-1666 25 20 04 1.20 200 400 CONV | 6.66 8H&83- 102 WR-62 16.5-17.5 UG-1666 25 20 0.3 1.20 10 2500 AIR 9.50 8H185-102 WR-28 30.3-33.5 UG-539 20 20 0.5 1.25 100 100 GONV | 4.90 8H94-101 WR-28 32.1-33.1 UG-539 25 20 05 1.15 100 3000 CONV | 4.90 8H94-102 WR-28 33.0-36.0 UG-599 20 20 05 1.20 100 100 CONV | 4.90 8H94-103 WR-28 34.5-36.5 UG-539 20 20 05 1.20 100 100 CONV | 4.90 8H94-104 WR-28 34.5-36.5 UG-600 25 20 05 1.15 10 1200 CONV | 4.90 8H182-101 Notes 1. Peak power handling capability will depend on pressurization, duty cycle, pulsewidth, load mismatch and altitude. 2. Average power handling capability may be increased by heat sinking, fins or liquid cooling. 3. High power circulators may be built with a load at port 4 for a duplexer function or loads at ports 3 and 4 for an isolator application. Reflected power into load must be specified. Specifications Subject to Change Without Notice. M/A-COM, Inc. North America: Tel. (800) 366-2266 Fax (800) 618-8883 m Asia/Pacific: Tel. +81 (03) 3226-1671 Fax +81 (03) 3226-1451 Europe: Tel. +44 (1344) 869 595 Fax +44 (1344) 300 020