Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232
WPC10 Series
10W Regulated 2:1 Wide Input Range DC/DC Converter
KDC_WPC10.D01 Page 1 of 3
www.murata-ps.com
For full details go to
www.murata-ps.com/rohs
 
www.murata-ps.com
SELECTION GUIDE
Order Code
Nominal
Input
Voltage
Output
Voltage
Output Current Voltage Regulation
Noise
Efficiency
Recommended
Alternative
Min
Load
Rated
Load Line Load
V V mA mA ± ± mVpp %
WPC10R24S05C Obsolete, recommended alternative:
(click to view data sheets)
NPH10S2405IC
WPC10R24S12C NPH10S2412IC
WPC10R24D15C BWR-15/575-D24A-C
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Voltage range Continuous operation 18 24 36 V
Reflected ripple current 20 50 mAp-p
OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Rated Power 10 W
Voltage set point accuracy ±1 %
Temperature coefficient ±0.02 %/ºC
Line regulation Low line to high line Singles ±0.2
%
Duals ±0.2
Load regulation Min load to rated load Singles ±0.2
Duals ±0.5
Ripple & noise BW = 5Hz to 20MHz 75 mVp-p
ABSOLUTE MAXIMUM RATINGS
Output short circuit protection Continuous
Internal power dissipation 2.5W
Maximum case temperature +110ºC
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Isolation test voltage 60Hz, 10 seconds 1500 Vpk
Resistance 10
Capacitance 1500 pF
Leakage current VISO = 240VAC, 60Hz 100 μArms
TEMPERATURE CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Specification (ambient) -40 71
ºC
Case temperature -40 100
Storage -55 125
GENERAL CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Switching frequency 350 KHz
MTTF MIL-HDBK-217F Ground benign 933 KHr
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
FEATURES
RoHS compliant
Safety approval (cULus)
Meets EN55022 level A & B for conducted
Emissions with a 10 micro farad external
capacitor
Industry standard pinouts
Industry standard package
Low profile 0.4 inch (10mm)
Short circuit protection
Temperature shutdown
DESCRIPTION
The WPC10 series is a family of DC/DC converters
that offer regulated outputs over an input voltage
range 18 - 36V and over a wide specification case
temperature range of -40°C to +100°C.
The 350kHz switching frequency and forward
converter topology provide optimum performance
in a space-saving package. The design uses
all surface mounted components, including
magnetics, to provide enhanced reliability.
All models will operate under very low load
conditions, although the minimum load is required
to guarantee full parametric functionality. A metal
package is utilized for decreased radiated noise.
The product range has been recognised by Under-
writers Laboratory (UL) to UL 1950 for operational
insulation, file number E179522 applies.
ide
OBSOLETE
10W R
0W R
OBSOLETE
OBSOLETE
Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232
WPC10 Series
10W Regulated 2:1 Wide Input Range DC/DC Converter
KDC_WPC10.D01 Page 2 of 3
www.murata-ps.com
THERMAL DERATING CURVE
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions WPC10 series of dc/dc converters are all 100% production tested at their stated isolation voltage. This is 1500V Vpk for 10 seconds.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The WPC10 series has been recognized by Underwriters Laboratory, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC.
The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be
expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded
as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard
requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materi-
als, construction and environment. While manufactured parts can withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any
material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of
tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from
specified test voltage.
FUSING
The WPC10 series DC/DC converter may be optionally fused with a 2A fuse. The input must be SELV or TNV according to EN60950/IEC950. UL recognition was obtained without an
input fuse.
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC for 10 seconds. The pin termination finish
on this product series is UNS C36000 brass plated with matte tin 100 micro-inches min., over nickel, 40-80 micro-inches. The series is backward
compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs
WPC10 Series
10W Regulated 2:1 Wide Input Range DC/DC Converter
KDC_WPC10.D01 Page 3 of 3
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice. © 2012 Murata Power Solutions, Inc.
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
www.murata-ps.com/locations
MECHANICAL DIMENSTIONS
Weight: 35g (Typ.)
All pins on a 0.1 (2.54) pitch and within ±0.01 (0.25) of true position.
Unless otherwise stated all dimensions are in inches (mm) ±0.01 (0.25).
4
6
1
2
.100 [2.54]
.400 [10.16]
.600 [15.24]
.900
[22.86]
.500
[12.70]
1.400
[35.56]
.600
[15.24]
.000
[0.00]
.000 [0.00]
1.000 [25.40]
2.000
[50.80]
.415
[10.54]
.020 [0.51]
5
.230 [5.84]
MIN
BOTTOM (PIN SIDE) VIEW
SIDE VIEW
PIN CONNECTIONS
Pin Function
Singles Duals
1+VIN +VIN
2-VIN -VIN
4+VOUT +VOUT
5 No pin Common
6-V
OUT -VOUT