NEGATIVE ADJUSTABLE
VOLTAGE REGULATOR
Semelab Limited
Semelab LimitedSemelab Limited
Semelab Limited
Coventry Road, Lutterworth, Leicestershire, LE17 4JB
Telephone +44 (0) 1455 556565 Fax +44 (0) 1455 552612 Email: sales@semelab-tt.com Website: http://www.semelab-tt.com
Document Number 8380
Issue 1
Page 3 of 7
ELECTRICAL CHARACTERISTICS(1)(3)
(TC = 25°C unless otherwise stated)
LM137A, IP137A, LM137AHV, IP137AHV
Symbols Parameters Test Conditions Min.
Typ Max.
Units
IOUT = 10mA
-1.238
-1.250
-1.262
VREF Reference Voltage 10mA ≤ IOUT ≤ IMAX, P ≤ PMAX,
3V ≤ (VIN-VOUT) ≤ VMAX
●
-1.220
-1.250
-1.280
V
0.005 0.010
IN
OUT
V
V
∆
∆
Line Regulation (2)
3V ≤ (VIN-VOUT) ≤ VMAX,
IOUT = 10mA
●
0.010 0.030
%/V
VOUT ≤ 5V
5 25 mV
VOUT ≥ 5V
0.1 0.5 %
VOUT ≤ 5V
●
10 50 mV
OUT
I
OUT
V
∆
∆ Load Regulation (2)(3) 10mA ≤ IOUT ≤ IMAX
VOUT ≥ 5V
●
0.2 1.0 %
Thermal Regulation VIN = -14.58V, IOUT = 1.5A,
PD = 20W, TA = 25°C, 10ms Pulse
0.002 0.02 %/W
VOUT = -10V CADJ = 0
60 66
Ripple Rejection
f = 120Hz CADJ = 10µF
●
70 80
dB
IADJ Adjust Pin Current
●
65 100
10mA ≤ IOUT ≤ IMAX
●
0.2 2
3V ≤ (VIN-VOUT) ≤ 40V
●
1.0 5
∆IADJ Adjust Pin Current Change
3V ≤ (VIN-VOUT) ≤ 50V (HV Series)
(HV Series)(HV Series)
(HV Series)
●
2 6
µA
(VIN - VOUT) ≤ 40V
●
2.5 5
IMIN Minimum Load Current (VIN - VOUT) ≤ 10V
●
1.2 3
mA
(VIN - VOUT) ≤ 15V
●
1.5 2.2 3.2
(VIN - VOUT) = 40V
●
0.24 0.4 1.0
ICL Current Limit
(VIN - VOUT) = 50V (HV Series)
(HV Series)(HV Series)
(HV Series)
●
0.2 0.4 0.8
A
TEMP
OUT
V
∆
∆ Temperature Stability
●
0.6 1.5
TIME
OUT
V
∆
∆ Long Term Stability TA = 125°C, 1000Hrs
0.3 1.0
en RMS Output Noise
(% of VOUT) TA = 25°C, 10Hz ≤ f ≤ 10KHz
0.003
%
Notes
NotesNotes
Notes
The ● denotes the specifications which apply over the full operating temperature range.
(1) Test conditions unless otherwise stated: VIN - VOUT = 5V, IOUT = 0.5A, PMAX = 20W, IMAX = 1.5A
(2) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to heating
effects are covered under thermal regulation specifications. Load regulation is measured at
1
/
8
” below the bottom of the package.
(3) VMAX = 40V for LM137, IP137, LM137A, IP137A, LM337, IP337, LM337A, IP337A