14
Low Voltage Products & Systems 14.21
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 400 008 C0201 (LV 008)
14
Accessories
S200
S2C-H6R
S2C-A_
Discount schedule CB8
Delivery Class
A - Standard item, stock to 2 weeks lead time
B - Stock to 4 weeks lead time
C - 6 to 8 week lead time
Accessories
S2C-S/H6R
S2C-UA_
Electrical For Catalog List Delivery Suggested Wgt. oz.
accessories use on: number price class order quantities (1 pc.)
Auxiliary contacts
For field mounting: right side S200 & S2C-H6R
1 N.O./ 1 N.C. S200P
$ 36 A 1 1.4
S200U
S200UP S2C-H6RU
The auxiliary contacts will signal whether the breaker is in the ON or OFF position. The contacts are rated 6A/240 VAC and 1.5A/110 VDC.
Minimum operating voltage is 12 VAC/VDC.
Wire size: 18 AWG to 16 AWG.
Bell alarm
S200 & *S2C-S/H6R
S200P
A 1 1.4
For field mounting, right side 48
S200U S2C-S6RU
S200UP
The bell alarm includes a set of contacts that will only signal when the breaker has tripped. Typically the contacts would be connected to an alarm
or bell to signal the operator that an overcurrent trip has occured. The bell alarm also includes a test button for testing the alarm contacts without
opening the breaker. The contact is rated 6A/240 VAC and 1.5A/110 VDC. Minimum operating voltage is 12 VAC/VDC.
* Combination bell alarm/auxiliary contact
Shunt trip
S200 & S2C-A1
For field mounting, right side S200P S2C-A2
A1-12-60 VAC (12-60VDC) 138 A 1 5.2
A2-110-415 VAC (110-250 VDC) S200U & S2C-A1U
S200UP S2C-A2U
For remote tripping of breaker, a shunt trip device can be added to the MCB. The solenoid device opens the breaker after control voltage is
applied. Shunt trips are available for on control system voltage (12-415 VAC/VDC).
Undervoltage release
For field mounting, right side
12 VDC S2C-UA12
24 VAC/VDC S2C-UA24
48 VAC/VDC S200 & S2C-UA48 216 A 1 5.2
110 VAC/VDC S200P S2C-UA110
220 VAC/VDC S2C-UA230
380 VAC S2C-UA400
When control voltage drops below approximately 50% of rated voltage, the UVR opens the breaker. The breaker can not be operated unless
proper control voltage is first applied to the UVR coil. Similar in size and mounting to the shunt trip accessory.
Factory mounting
All accessories can be easily mounted in the field. For factory mounting of any accessory devices, add $30
list to total price per breaker. To create complete catalog number, take suffix of accessory device following
“S2C-” and add suffix to end of breaker part number. Multiple suffixes must be added in alphabetical order.
Example: S202-K20A1 $ 264 (2 pole, 20A breaker with type A1 shunt trip) S202-K20 @ $96 + S2C-A1
@ $138 + factory mounting @ $30 = $264
S202-K20A2H6R $ 300 (2 pole, 20A breaker with type A2 shunt trip and H6R aux. contacts) S202-
K20 @ $96 + S2C-A1 @ $138 + S2C-H6R @ $36 + factory mounting @ $30 = $300
Auxiliary contacts and shunt trips may be mounted in combination.