1
G
3
V
M
2
1
H
R
/
3
1
H
R
/
4
1
H
R
/
6
1
H
R
/
6
1
H
R
1
I
S
O
P
G3VM-21HR/31HR/41HR/61HR/61HR1
MOS FET Relays SOP 6-pin, High-current and Low-ON-resistance Type
MOS FET Relays in SOP 6-pin
packages that achieve the low ON
resistance and high switching capacitance
of a mechanical relay
Load voltage: 20 V, 30 V, 40 V, or 60 V
20-V Relay: Continuous load current of 2.5 A (5 A) max.*
30-V Relay: Continuous load current of 4 A (8 A) max.*
40-V Relay: Continuous load current of 2.5 A (5 A) max.*
60-V Relay: Continuous load current of 3.3 A (6.6 A) max.*
*Values in parentheses are for connection C.
Application Examples
Ordering Information
*The AC peak and DC value are given for the load voltage and continuous load current.
Note: To order tape packaging for Relays with surface-mounting terminals, add “(TR)” to the end of the model number.
RoHS Compliant
Package (Unit : mm, Average) Model Number Legend
Package Contact
form Terminals Load voltage
(peak value) *
Continuous load current
(peak value) *Stick packaging Tape packaging
Connection
A, B
Connection
CModel
Minimum
package
quantity
Model
Minimum
package
quantity
SOP6 1a
(SPST-NO)
Surface-mounting
Terminals
20 V 2.5 A 5 A G3VM-21HR
75
G3VM-21HR(TR) 2,500
30 V 4 A 8 A G3VM-31HR G3VM-31HR(TR05) 500
40 V 2.5 A 5 A G3VM-41HR G3VM-41HR(TR) 2,500
60 V 2.3 A 4.6 A G3VM-61HR G3VM-61HR(TR) 2,500
3.3 A 6.6 A G3VM-61HR1 G3VM-61HR1(TR05) 500
Note: The actual product is marked differently from the
image shown here.
Semiconductor test equipment
Communication equipment
Test & Measurement equipment
Security equipment
Industrial equipment
Power circuit
Amusement equipment
Note: The actual product is marked differently
from the image shown here.
SOP 6-pin
2.1
4.4
6.3
G3VM-@ @ @ @ @
12345
1. Load Voltage
2 : 20 V
3 : 30 V
4 : 40 V
6 : 60 V
2. Contact form
1 : 1a (SPST-NO)
3. Package
H : SOP 6-pin
5. Other informations
When specifications overlap, serial
code is added in the recorded order.
4. Additional functions
R: Low ON resistance
2
G3VM-21HR/31HR/41HR/61HR/61HR1
MOS FET Relays
G
3
V
M
2
1
H
R
/
3
1
H
R
/
4
1
H
R
/
6
1
H
R
/
6
1
H
R
1
I
S
O
P
Absolute Maximum Ratings (Ta = 25°C)
Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on
the light-receiving side.
Item Symbol G3VM-21HR G3VM-31HR G3VM-41HR G3VM-61HR G3VM-61HR1 Unit Measurement conditions
Input
LED forward current IF30 mA
LED forward current reduction
rate ΔIF/°C -0.3 mA/°C Ta 25°C
LED reverse voltage VR5V
Connection temperature TJ125 °C
Output
Load voltage (AC peak/DC) VOFF 20 30 40 60 V
Continuous
load current
Connection A
IO
2500 4000 2500 2300 3300 mA
Connection A:
AC peak/DC
Connection B and C:
DC
Connection B
Connection C 5000 8000 5000 4600 6600
ON current
reduction rate
Connection A
ΔIO/°C -33.3 -40 -33.3 -30.7 -33 mA/°C
G3VM-31HR/61HR1:
Ta 25°C
Others: Ta 50°C
Connection B
Connection C -66.7 -80 -66.7 -61.3 -66
Pulse ON current lop 7.5 12 7.5 7 10 A t=100 ms, Duty=1/10
Connection temperature TJ125 °C
Dielectric strength between I/O
(See note 1.) VI-O 1500 Vrms AC for 1 min
Ambient operating temperature Ta -40 to +85 °C With no icing or
condensation
Ambient storage temperature Tstg -55 to +125 °C
Soldering temperature 260 °C 10 s
Connection Diagram
Connection A
Connection B
Connection C
Load
or AC
DC
1
2
3
6
5
4
1
2
3
6
5
4
DC
Load
Load
DC
1
2
3
6
5
4
3
G3VM-21HR/31HR/41HR/61HR/61HR1
MOS FET Relays
G
3
V
M
2
1
H
R
/
3
1
H
R
/
4
1
H
R
/
6
1
H
R
/
6
1
H
R
1
I
S
O
P
Electrical Characteristics (Ta = 25°C)
Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
Spacing and Insulation
Item Symbol G3VM-21HR G3VM-31HR G3VM-41HR G3VM-61HR
G3VM-61HR1
Unit Measurement conditions
Input
LED forward voltage VF
Minimum 1.18
V IF=10 mATypical 1.33
Maximum 1.48
Reverse current IRMaximum 10 μAVR=5 V
Capacitance between
terminals CTTypical 70 pF V=0, f=1 MHz
Trigger LED forward current IFT
Typical 0.3 0.4 0.2 mA G3VM-61HR1 : IO=2000 mA
Others :
IO=100 mA
Maximum 3
Release LED forward current IFC Minimum 0.1 mA IOFF=10 μA
Output
Maximum
resistance
with output
ON
Connection A
RON
Typical
0.02 0.02 0.03 0.04 0.03
Ω
G3VM-31HR:
IF=5 mA
IO=4 A (Connection A, B)
IO=8 A (C connections), t<1s
Others:
IF=5 mA
IO=2 A (Connection A, B)
IO=4 A (C connections), t<1s
Connection B 0.01 0.008 0.015 0.02 0.015
Connection C 0.005 0.004 0.008 0.01 0.008
Connection A
Maximum
0.05 0.04 0.06 0.07 0.06
Connection B 0.025 0.02 0.03 0.04
Connection C 0.01
Current leakage when the
relay is open ILEAK
Typical nA VOFF= Load voltage ratings
Maximum 10 1000 10 20
Capacitance between
terminals COFF
Typical 1000 1100 1000 700 pF V=0, f=1 MHz
Maximum 1500
Capacitance between I/O
terminals CI-O Typical 0.8 pF f=1 MHz, VS=0 V
Insulation resistance between I/O
terminals RI-O
Minimum 1000 MΩVI-O=500 VDC, ROH60%
Typical 108
Turn-ON time tON
Typical 1.5 1.1 1.0 0.6
ms
G3VM-21HR :
IF=5 mA, RL=200 Ω,
VDD=10 V (See note 2.)
Others :
IF=5 mA, RL=200 Ω,
VDD=20 V (See note 2.)
Maximum 5
Turn-OFF time tOFF
Typical 0.1 0.1 0.15 0.2
Maximum 1
Note: 2. Turn-ON and Turn-OFF Times
Item Symbol G3VM-21HR G3VM-31HR G3VM-41HR G3VM-61HR G3VM-61HR1 Unit
Load voltage (AC peak/DC) VDD Maximum2024406048V
Operating LED forward current IF
Minimum 5
mA
Typical 10 7.5 10
Maximum 20 25 20 25
Continuous load current (AC peak/DC)
IOMaximum 2000 4000 2000 1800 3300
Ambient operating temperature Ta Minimum -20 °C
Maximum 65
Item Minimum Unit
Creepage distances 4.0
mm
Clearance distances 4.0
Internal isolation thickness 0.1
VOUT
IF
tON tOFF
10% 90%
IF1
2
6
4
RLVDD
VOUT
4
G3VM-21HR/31HR/41HR/61HR/61HR1
MOS FET Relays
G
3
V
M
2
1
H
R
/
3
1
H
R
/
4
1
H
R
/
6
1
H
R
/
6
1
H
R
1
I
S
O
P
Engineering Data
LED forward current vs.
Ambient temperature
Continuous load current vs.
Ambient temperature
G3VM-31HR/61HR1 G3VM-21HR/41HR/61HR
LED forward current vs.
LED forward voltage
Continuous load current vs.
On-state voltage
On-state resistance vs.
Ambient temperature
Trigger LED forward current vs.
Ambient temperature
Turn ON, Turn OFF time vs.
LED forward current
I
O
- Ta
Ambient temperature Ta (°C)
-20-40 100 80 60 40 020
0
1
2
3
4
5
6
7
8
9(Maximum value)
Continuous load current IO (A)
G3VM-31HR :
Connection A, B
G3VM-61HR1 :
Connection A, B
G3VM-31HR : Connection C
G3VM-61HR1 :
Connection C
I
O
- Ta
Ambient temperature Ta (°C)
-40 -20 0 20 40 60 80 100
0
1
2
3
4
5
6
(Maximum value)
Continuous load current I
O
(A)
G3VM-21HR/-41HR :
Connection A, B
G3VM-61HR :
Connection A, B
G3VM-21HR/-41HR : Connection C
G3VM-61HR : Connection C
I
F
- V
F
LED forward voltage V
F
(V)
0.80.6 1 1.2 1.4 1.6 1.8
(Average value)
0.1
1
10
100
LED forward current IF (mA)
Ta=25°C
G3VM-21HR
G3VM-41HR
G3VM-61HR
G3VM-31HR
G3VM-61HR1
I
O
- V
ON
On-state voltage V
ON
(V)
Continuous load current IO (A)
-5
-4
-3
-2
-1
0
1
2
3
4
5
- 0.1 0 0.1
Ta=25°C
IF=5mA
Connection A
G3VM-61HR1
G3VM-41HR
G3VM-31HR
G3VM-21HR
G3VM-61HR
(Average value)
R
ON
- Ta
Ambient temperature Ta (°C)
-20-40 10080 60 40 020
(Average value)
0
0.02
0.04
0.06
0.08
0.1
0.12
On-state resistance RON (Ω)
G3VM-61HR
G3VM-31HR G3VM-41HR
G3VM-21HR
G3VM-61HR1
IO=2A, IF=5mA, t<1s, Connection A
I
FT
- Ta
Ambient temperature Ta (°C)
-40 -20 100 80 60 40 020
(Average value)
0
0.2
0.4
0.6
0.8
1
IO=100mA
t<1s
Trigger LED forward current IFT (mA)
G3VM-61HR
G3VM-41HR
G3VM-31HR
G3VM-61HR1
G3VM-21HR
t
ON
, t
OFF
- I
F
LED forward current I
F
(mA)
101100
(Average value)
0.01
0.1
1
10
Turn ON, Turn OFF time tON, tOFF (ms)
G3VM-21HR : Ta=25°C, VDD=10V, RL=200Ω
Other : Ta=25°C, VDD=20V, RL=200Ω
tON
tOFF
G3VM-21HR
G3VM-41HR
G3VM-41HR
G3VM-61HR1
G3VM-31HR
G3VM-61HR
5
G3VM-21HR/31HR/41HR/61HR/61HR1
MOS FET Relays
G
3
V
M
2
1
H
R
/
3
1
H
R
/
4
1
H
R
/
6
1
H
R
/
6
1
H
R
1
I
S
O
P
Engineering Data
Turn ON, Turn OFF time vs.
Ambient temperature
Current leakage vs. Load voltage
G3VM-21HR/41HR/61HR
Current leakage vs.
Ambient temperature
G3VM-31HR/61HR1
Output terminal capacitance vs.
Load voltage
G3VM-21HR/41HR/61HR
t
ON
, t
OFF
- Ta
Ambient temperature Ta (°C)
-40 -20 10080 60 40 020
(Average value)
0.01
0.1
1
10
Turn ON, Turn OFF time tON, tOFF (ms)
tOFF
tON
G3VM-21HR : VDD=10V, RL=200Ω, IF=5mA
Other : VDD=20V, RL=200Ω, IF=5mA
G3VM-61HR1
G3VM-61HR
G3VM-41HR
G3VM-21HR
G3VM-31HR
I
LEAK
- V
OFF
Load voltage V
OFF
(V)
80 100
60
40 020
0
0.5
1
1.5
2
2.5
Current leakage ILEAK (nA)
G3VM-21HR
G3VM-61HR
G3VM-41HR
Ta=25°C
1
10
100
1000
10000
100000
1000000
I
LEAK
- Ta
Ambient temperature Ta (°C)
(Average value)
Current leakage ILEAK (pA)
-40 -20 0 20 40 60 80
100 120
VOFF=20V
G3VM-31HR
G3VM-61HR1
C
OFF
- V
OFF
Load voltage V
OFF
(V)
40
30
20010
(Average value)
0
0.2
0.4
0.6
0.8
1
Output terminal capacitance COFF/COFF(0V)
G3VM-21HR
G3VM-61HR
G3VM-41HR
Ta=25°C
6
G3VM-21HR/31HR/41HR/61HR/61HR1
MOS FET Relays
G
3
V
M
2
1
H
R
/
3
1
H
R
/
4
1
H
R
/
6
1
H
R
/
6
1
H
R
1
I
S
O
P
Appearance / Terminal Arrangement / Internal Connections
Dimensions (Unit: mm)
Approved Standards
UL recognized
Safety Precautions
Refer to the Common Precautions for All MOS FET Relays for precautions that apply to all MOS FET Relays.
Appearance Terminal Arrangement/Internal Connections
(Top View)
SOP (Small Outline Package)
SOP (Small Outline Package)
SOP 6-pin
OMRON logo
Pin 1 mark
Model name (See note 2.)
LOT.NO.
932
Mold pin mark (See note 3.)
Note: 1. The actual product is marked differently from the image shown here.
Note: 2. “G3VM” does not appear in the model number on the Relay.
Note: 3. The indentation in the corner diagonally opposite from the pin 1 mark
is from a pin on the mold.
654
13
2
Note: The actual product is marked differently from the image shown here.
Approved Standards Contact form File No.
UL (recognized) 1a (SPST-NO) E80555
Surface-mounting Terminals
Weight: 0.13 g
4.4
±0.25
6.3±0.25
0.4±0.1
2.54±0.25
2.1 max.
0.1±0.1
7.0±0.4
0.6±0.3
0.15
Actual Mounting Pad Dimensions
(Recommended Value, Top View)
6 to 6.3
1.2
0.8
2.542.54
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb Cat. No. K288-E1-02
0317(0217)(O)
Note: Do not use this document to operate the Unit.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanism
s.