EN5365QI Ev aluation Board
Instructions
The numbers in the instructions below correspond
to the num bers in Figure 1. By fol lowing the num be r
sequence below, the device can be turned on by
step 5.
1) ENABLE – The jumper on the left two pins
enables the device by connecting ENABLE
to AVIN. Remove this jumper and then
connect it to the right two pins to connect
ENABLE to ground and disable the device.
Leave the pins open and use an external
signal to the center pin to toggle the
ENABLE on (>1.8V) and off (<0.8V).
2) Output Voltage Settings (VSx) - As
shown, output voltage is set to 1.8V. The
left pin of VS2, VS1, VS0 pulls VS2, VS1,
VS0 pin to AVIN (high = 1), respectively.
The r ight pin pulls the VS2, VS1, VS0 pin to
ground (low = 0). DO NOT change the
output voltage when the device is in
regulation; otherwise, damage may occur.
Follow the Table below for other output
voltage settings.
VS2 VS1 VS0 VOUT
3) PVIN (J2) - Connect 2.5V to 5.5V supply on
J2 (VIN). Do not turn on until everything is
connected correctly.
4) Ground (J3 and J4) - Connect the input
supply ground to J4 and the output ground
to J3.
5) VO UT ( J5) - Connect the load to J5. If th e
instructions were followed up to this point,
the device may be power ed to turn on.
6) POK - This is the open drain POK flag,
which is pulled up to AVIN by R1. When
VOUT is between 90% and 120% of the
nominal regulation output voltage, POK will
be pulled high to AVIN; otherwise, the POK
pin is pulled low.
7) Soft Start Capacito r (C1) – Th e soft star t
capacitor is by defaulted 15nF and can be
adjusted to increase or decrease the soft-
start time. See the equation below.
Tss [s] = Css [F] * 75
The soft-start time (T ss) is in seconds and
the soft-start capacita nce (Css) is in Farad s .
See Datasheet for details.
8) Input Protection – The EN5365QI
evaluation board comes with some input
polar ity pr otection.
www.altera.com/enpirion, Page 2
10706 February 6, 2015 Rev C