SPECIFICATION
MODEL RS-25-3.3 RS-25-5 RS-25-12 RS-25-15 RS-25-24 RS-25-48
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISE,HOLDTIME
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
ACCURRENT
INPUT
INRUSHCURRENT(max.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
3.3V 5V 12V 15V 24V 48V
6A 5A 2.1A 1.7A 1.1A 0.57A
0~6A 0~5A 0~2.1A 0~1.7A 0~1.1A 0~0.57A
19.8W 25W 25.2W 25.5W 26.4W 27.36W
80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p
2.85V~3.6V 4.75~5.5V 10.8~13.2V 13.5~16.5V 22~27.6V 42~54V
3.0% 2.0% 1.0% 1.0% 1.0% 1.0%
0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
2.0% 1.0% 0.5% 0.5% 0.5% 0.5%
1200ms,20ms,50ms/230VAC2200ms,30ms,12ms/115VAC atfullload
88~264VAC125~373VDC (Withstand300VACsurgefor5sec.Withoutdamage)
47~63Hz
72%
3.8~4.45V 5.75~6.75V 13.8~16.2V 17.25~20.25V 27.6~32.4V 55.2~64.8V
77% 79% 82% 84% 85%
0.7A/115VAC0.4A/230VAC
COLDSTART 36A/230VAC
<2mA /240VAC
110~180% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
UL60950-1, TUVEN60950-1 Approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
-20~+70 (Refertooutputloadderatingcurve)
20~90%RH non-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,5G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
309.7Khrsmin.MIL-HDBK-217F(25 )
79*51*28mm(L*W*H)
FileName:RS-25-SPEC2004-07-13
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
EMICONDUCTION&RADIATION
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
25WSingleOutputSwitchingPowerSupply RS-25 seri es
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204lightindustrylevel,criteria A
0.2Kg;60pcs/13Kg/0.57CUFT
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
long life electrolytic capacitors
Features :