MC13 Series 6A to 30A, 500VAC 3 Phase EMI Filters Features u Industry Standard Size u DIN Rail Mountable Specifications Model Rated Voltage (AC) Rated Current (AC) (1) Test Voltage (terminal to baseplate, AC 1 min.) Isolation Resistance (terminal to baseplate, 500VDC) Leakage Current (500V, 60Hz) DC Resistance (three lines) Temperature Rise Operating Temperature Operating Humidity Storage Temperature Storage Humidity Vibration Safety Standard Size Weight (Typ.) Note (1) MC1306DIN V A V 6 MC1310DIN MC1320DIN 500 (50/60Hz) Three Phase 10 20 2000 (100mA) @ 25C, 70%RH M mA M C C % C % mm g MC1330DIN 30 100M min. @ 25C, 70%RH 5.0 max 90 max 68 max 23 max 11 max 30 max -25 to +85C 30% to 95% RH (non-condensing) -40 to +85C 10% to 95% RH (non-condensing) 10~55Hz, (Sweep for 1 min) 9.8m/s2, X, Y, Z axes, 1 hour each Approved to UL1283, CSA std.C22.2No.8(CUL), EN133200(VDE) 135.5 (L) x 59.4 (H) x 63 (W) 600 Value for Ta < 50C. For Ta > 50C derate according to the derating curve. 1-800-526-2324 * www.us.tdk-lambda.com/lp/ 11 Disclaimer: us.tdk-lambda.com/lp/legal.htm MC13 Series Outline Drawing Derating Current (%) 120 100 80 60 40 20 0 25 Typ. Attenuation, Symmetrical MC1310 MC1320 MC1330 MC1306 0 0 20 20 40 40 60 80 100 120 0.1 50 60 70 80 90 Typ. Attenuation, Asymmetrical Attenuation (dB) Attenuation (dB) MC1306 40 MC1310 MC1320 MC1330 60 80 100 1 10 Frequency (MHz) 120 0.1 100 1 10 Frequency (MHz) 100 For Additional Information, please visit us.tdk-lambda.com/lp/products/mc13-series.htm Last time buy - June 1, 2014 1-800-526-2324 * www.us.tdk-lambda.com/lp/ 12 Revision A3: May 2013