111-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
MC13 Series
Features
u Industry Standard Size
u DIN Rail Mountable
6A to 30A, 500VAC 3 Phase EMI Filters
Model MC1306DIN MC1310DIN MC1320DIN MC1330DIN
Rated Voltage (AC) V 500 (50/60Hz) Three Phase
Rated Current (AC) (1) A 6 10 20 30
Test Voltage V 2000 (100mA) @ 25°C, 70%RH
(terminal to baseplate, AC 1 min.)
Isolation Resistance MΩ 100MΩ min. @ 25°C, 70%RH
(terminal to baseplate, 500VDC)
Leakage Current (500V, 60Hz) mA 5.0 max
DC Resistance (three lines) MΩ 90 max 68 max 23 max 11 max
Temperature Rise °C 30 max
Operating Temperature °C -25 to +85°C
Operating Humidity % 30% to 95% RH (non-condensing)
Storage Temperature °C -40 to +85°C
Storage Humidity % 10% to 95% RH (non-condensing)
Vibration - 10~55Hz, (Sweep for 1 min) 9.8m/s2, X, Y, Z axes, 1 hour each
Safety Standard - Approved to UL1283, CSA std.C22.2No.8(CUL), EN133200(VDE)
Size mm 135.5 (L) x 59.4 (H) x 63 (W)
Weight (Typ.) g 600
Specifi cations
Note (1) Value for Ta < 50°C.
For Ta > 50°C derate according to the derating curve.
121-800-526-2324 • www.us.tdk-lambda.com/lp/ Revision A3: May 2013
MC13 Series
For Additional Information, please visit
us.tdk-lambda.com/lp/products/mc13-series.htm
MC1306 MC1310 MC1320 MC1330
Attenuation (dB)
Frequency (MHz)
0.1 1 10
0
20
40
60
80
100
120
100
0
20
40
60
80
100
120
25 40 50 60 70 80 90
Current (%)
MC1306 MC1310 MC1320 MC1330
Attenuation (dB)
Frequency (MHz)
0.1 1 10
0
20
40
60
80
100
120
100
Outline Drawing
Typ. Attenuation, Symmetrical
Derating
Typ. Attenuation, Asymmetrical
Last time buy - June 1, 2014