6.4V TEMPERATURE COMPENSATED
ZENER DIODE
1N4565 - 1N4584AD2A
1N4565 - 1N4584AD2B
Semelab
SemelabSemelab
Semelab
Limited
LimitedLimited
Limited
Coventry Road, Lutterworth, Leicestershire, LE17 4JB
Document Number 8251
Telephone +44 (0) 1455 556565
Fax +44 (0) 1455 552612
Issue 3
Email: sales@semelab-tt.com
Website: http://www.semelab-tt.com
Page 2 of 4
ELECTRICAL STABILITY CHARACTERISTICS
(TA = 25°C unless otherwise stated)
Type IZT ∆
∆∆
∆VZ ZZ
Zener Test
Current
Zener Voltage Coefficient
(1)
Dynamic Impedance
±0.01mA dc
(1)
At IZT At IZT, Isig = 10% IZT rms
max. TA ±2°C
max.
mA mV
°C
Ω
1N4565 0.5 48 0, +25, +75 200
1N4566 0.5 24 0, +25, +75 200
1N4567 0.5 10 0, +25, +75 200
1N4568 0.5 5 0, +25, +75 200
1N4569 0.5 2 0, +25, +75 200
1N4565A 0.5 100 -55, 0, +25, +75, +100 200
1N4566A 0.5 50 -55, 0, +25, +75, +100 200
1N4567A 0.5 20 -55, 0, +25, +75, +100 200
1N4568A 0.5 10 -55, 0, +25, +75, +100 200
1N4569A 0.5 5 -55, 0, +25, +75, +100 200
1N4570 1.0 48 0, +25, +75 100
1N4571 1.0 24 0, +25, +75 100
1N4572 1.0 10 0, +25, +75 100
1N4573 1.0 5 0, +25, +75 100
1N4574 1.0 2 0, +25, +75 100
1N4570A 1.0 100 -55, 0, +25, +75, +100 100
1N4571A 1.0 50 -55, 0, +25, +75, +100 100
1N4572A 1.0 20 -55, 0, +25, +75, +100 100
1N4573A 1.0 10 -55, 0, +25, +75, +100 100
1N4574A 1.0 5 -55, 0, +25, +75, +100 100
1N4575 2.0 48 0, +25, +75 50
1N4576 2.0 24 0, +25, +75 50
1N4577 2.0 10 0, +25, +75 50
1N4578 2.0 5 0, +25, +75 50
1N4579 2.0 2 0, +25, +75 50
1N4575A 2.0 100 -55, 0, +25, +75, +100 50
1N4576A 2.0 50 -55, 0, +25, +75, +100 50
1N4577A 2.0 20 -55, 0, +25, +75, +100 50
1N4578A 2.0 10 -55, 0, +25, +75, +100 50
1N4579A 2.0 5 -55, 0, +25, +75, +100 50
1N4580 4.0 48 0, +25, +75 25
1N4581 4.0 24 0, +25, +75 25
1N4582 4.0 10 0, +25, +75 25
1N4583 4.0 5 0, +25, +75 25
1N4584 4.0 2 0, +25, +75 25
1N4580A 4.0 100 -55, 0, +25, +75, +100 25
1N4581A 4.0 50 -55, 0, +25, +75, +100 25
1N4582A 4.0 20 -55, 0, +25, +75, +100 25
1N4583A 4.0 10 -55, 0, +25, +75, +100 25
1N4584A 4.0 5 -55, 0, +25, +75, +100 25
Notes
NotesNotes
Notes
(1) To guarantee voltage temperature stability, it is necessary to maintain a stable IZ as specified