http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
THD 15N Series 15 Watt
Input Specifications
Input current at no load (nominal input voltage) 12 Vin models: 8 mA typ.
24 Vin models: 5 mA typ.
48 Vin models: 4 mA typ.
Input current at full load (nominal input voltage) 12 Vin models: 1450 mA typ.
24 Vin models: 720 mA typ.
48 Vin models: 360 mA typ.
Start-up voltage / 12 Vin models: 9.0 VDC / 8.0 VDC
under voltage shut down 24 Vin models: 18 VDC / 16 VDC
48 Vin models: 36 VDC / 33 VDC
Surge voltage (1 sec. max.) 12 Vin models: 36 V max.
24 Vin models: 50 V max.
48 Vin models: 100 V max.
Conducted noise (input) EN 55022 level A, FCC part 15, level A
(without external components)
ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
Radiated immunity EN 61000-4-3 10 V/m, perf. criteriy A
Fast transient / Surge EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV perf. criteria A
with external input capacitor e.g. Nippon
chemi-con KY 220 µF, 100 V, ESR 48 mOhm
Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
Reflected ripple current 20 mAp-p typ.
Output Specifications
Voltage set accuracy ±1 % max
Regulation – Input variation single output models: 0.2 % max. (Vin min to Vin max.)
dual output models: 0.5 % max. (Vin min to Vin max.)
– Load variation 0 – 100% single output models: 0.5 % max.
dual output models: 1.0 % max. balanced load
– Load variation 10 – 90% single output models: 0.3 % max.
dual output models: 0.8 % max. balanced load
– Load cross regulation 25/100% 5.0 % max. (dual output models)
Minimum load 0 % of rated max. load
Temperature coefficient ±0.02 %/K
Ripple and noise (20 MHz bandwidth) 60 mVp-p typ.
Output current limitation at 150 % of Iout max. foldback
Short circuit protection indefinite, automatic recovery
Over voltage protection (single output models only) 3.3 VDC models: 3.9 VDC
5.1 VDC models: 6.2 VDC
12 VDC models: 15 VDC
15 VDC models: 18 VDC
Start up time (nominal Vin and constant resistive load) 30 ms typ. (for power on and remote on)
Transient response setting time (25% load step change) 250 µs typ.
Capacitive load 3.3 VDC models: 4700 µF max.
5.1 VDC models: 3300 µF max.
12 VDC models: 600 µF max.
15 VDC models: 400 µF max.
±5 VDC models: ±1500 µF max.
±12 VDC models: ±288 µF max.
±15 VDC models: ±200 µF max.