Publication Number S29WS-P_00 Revision AAmendment 12 Issue Date January 28, 2008
S29WS-P
S29WS-P Cover Sheet
MirrorBit® Flash Family
S29WS512P, S29WS256P, S29WS128P
512/256/128 Mb (32/16/8 M x 16 bit)
1.8 V Burst Simultaneous Read/Write MirrorBit Flash Memory
Data Sheet
Notice to Readers: This document states the current technical specifications regarding the Spansion
product(s) described herein. Each product described herein may be designated as Advance Information,
Preliminary, or Full Production. See Notice On Data Sheet Designations for definitions.
2 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Notice On Data Sheet Designations
Spansion Inc. issues data sheets with Advance Information or Preliminary designations to advise readers of
product information or intended specifications throughout the product life cycle, including development,
qualification, initial production, and full production. In all cases, however, readers are encouraged to verify
that they have the latest information before finalizing their design. The following descriptions of Spansion data
sheet designations are presented here to highlight their presence and definitions.
Advance Information
The Advance Information designation indicates that Spansion Inc. is developing one or more specific
products, but has not committed any design to production. Information presented in a document with this
designation is likely to change, and in some cases, development on the product may discontinue. Spansion
Inc. therefore places the following conditions upon Advance Information content:
“This document contains information on one or more products under development at Spansion Inc.
The information is intended to help you evaluate this product. Do not design in this product without
contacting the factory. Spansion Inc. reserves the right to change or discontinue work on this proposed
product without notice.”
Preliminary
The Preliminary designation indicates that the product development has progressed such that a commitment
to production has taken place. This designation covers several aspects of the product life cycle, including
product qualification, initial production, and the subsequent phases in the manufacturing process that occur
before full production is achieved. Changes to the technical specifications presented in a Preliminary
document should be expected while keeping these aspects of production under consideration. Spansion
places the following conditions upon Preliminary content:
“This document states the current technical specifications regarding the Spansion product(s)
described herein. The Preliminary status of this document indicates that product qualification has been
completed, and that initial production has begun. Due to the phases of the manufacturing process that
require maintaining efficiency and quality, this document may be revised by subsequent versions or
modifications due to changes in technical specifications.”
Combination
Some data sheets contain a combination of products with different designations (Advance Information,
Preliminary, or Full Production). This type of document distinguishes these products and their designations
wherever necessary, typically on the first page, the ordering information page, and pages with the DC
Characteristics table and the AC Erase and Program table (in the table notes). The disclaimer on the first
page refers the reader to the notice on this page.
Full Production (No Designation on Document)
When a product has been in production for a period of time such that no changes or only nominal changes
are expected, the Preliminary designation is removed from the data sheet. Nominal changes may include
those affecting the number of ordering part numbers available, such as the addition or deletion of a speed
option, temperature range, package type, or VIO range. Changes may also include those needed to clarify a
description or to correct a typographical error or incorrect specification. Spansion Inc. applies the following
conditions to documents in this category:
“This document states the current technical specifications regarding the Spansion product(s)
described herein. Spansion Inc. deems the products to have been in sufficient production volume such
that subsequent versions of this document are not expected to change. However, typographical or
specification corrections, or modifications to the valid combinations offered may occur.”
Questions regarding these document designations may be directed to your local sales office.
Publication Number S29WS-P_00 Revision AAmendment 12 Issue Date January 28, 2008
Features
Single 1.8 V read/program/erase (1.70–1.95 V)
90 nm MirrorBit™ Technology
Simultaneous Read/Write operation with zero latency
Random page read access mode of 8 words with 20 ns intra
page access time
32 Word / 64 Byte Write Buffer
Sixteen-bank architecture consisting of
32/16/8 Mwords for 512/256/128P, respectively
Four 16 Kword sectors at both top and bottom of memory
array
510/254/126 64Kword sectors (WS512/256/128P)
Programmable linear (8/16/32) with or without wrap around
and continuous burst read modes
Secured Silicon Sector region consisting of 128 words each
for factory and 128 words for customer
20-year data retention (typical)
Cycling Endurance: 100,000 cycles per sector (typical)
Command set compatible with JEDEC (42.4) standard
Hardware (WP#) protection of top and bottom sectors
Dual boot sector configuration (top and bottom)
Handshaking by monitoring RDY
Offered Packages
WS512P/WS256P/WS128P: 84-ball FBGA
(11.6 mm x 8 mm)
Low VCC write inhibit
Persistent and Password methods of Advanced Sector
Protection
Write operation status bits indicate program and erase
operation completion
Suspend and Resume commands for Program and Erase
operations
Unlock Bypass program command to reduce programming
time
Synchronous or Asynchronous program operation,
independent of burst control register settings
ACC input pin to reduce factory programming time
Support for Common Flash Interface (CFI)
General Description
The Spansion S29WS512/256/128P are Mirrorbit® Flash products fabricated on 90 nm process technology. These burst mode
Flash devices are capable of performing simultaneous read and write operations with zero latency on two separate banks using
separate data and address pins. These products can operate up to 104 MHz and use a single VCC of 1.7 V to 1.95 V that
makes them ideal for today’s demanding wireless applications requiring higher density, better performance and lowered power
consumption.
Performance Characteristics
S29WS-P
MirrorBit® Flash Family
S29WS512P, S29WS256P, S29WS128P
512/256/128 Mb (32/16/8 M x 16 bit)
1.8 V Burst Simultaneous Read/Write MirrorBit Flash Memory
Data Sheet
Read Access Times
Speed Option (MHz) 104
Max. Synch Access Time (tIACC)103.8
Max. Synch. Burst Access, ns (tBACC)7.6
Max OE# Access Time, ns (tOE)7.6
Max. Asynch. Access Time, ns (tACC)80
Current Consumption (typical values)
Continuous Burst Read @ 104 MHz 36 mA
Simultaneous Operation 104 MHz 40 mA
Program 20 mA
Standby Mode 20 µA
Typical Program & Erase Times
Single Word Programming 40 µs
Effective Write Buffer Programming (VCC) Per Word 9.4 µs
Effective Write Buffer Programming (VACC) Per Word 6 µs
Sector Erase (16 Kword Sector) 350 ms
Sector Erase (64 Kword Sector) 600 ms
4 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Table of Contents
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Performance Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1. Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.1 Valid Combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2. Input/Output Descriptions & Logic Symbol. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3. Block Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4. Physical Dimensions/Connection Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.1 Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.2 Special Handling Instructions for FBGA Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.3 MCP Look-ahead Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5. Additional Resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6. Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6.1 Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
7. Device Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7.1 Device Operation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7.2 Asynchronous Read. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7.3 Page Mode Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
7.4 Synchronous (Burst) Read Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
7.5 Synchronous (Burst) Read Mode & Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . 28
7.6 Autoselect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
7.7 Program/Erase Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
7.8 Simultaneous Read/Program or Erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
7.9 Writing Commands/Command Sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
7.10 Handshaking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
7.11 Hardware Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
7.12 Software Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
8. Advanced Sector Protection/Unprotection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
8.1 Advanced Sector Protection Software Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
8.2 Lock Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
8.3 Persistent Protection Bits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
8.4 Dynamic Protection Bits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
8.5 Persistent Protection Bit Lock Bit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
8.6 Password Protection Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
8.7 Hardware Data Protection Methods. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
9. Power Conservation Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
9.1 Standby Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
9.2 Automatic Sleep Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
9.3 Hardware RESET# Input Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
9.4 Output Disable (OE#). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
10. Secured Silicon Sector Flash Memory Region . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
10.1 Factory Secured Silicon Sector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
10.2 Customer Secured Silicon Sector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
10.3 Secured Silicon Sector Entry/Exit Command Sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
11. Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
11.1 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
11.2 Operating Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
11.3 DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
11.4 Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
11.5 Key to Switching Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
11.6 Switching Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
11.7 Power-up/Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
January 28, 2008 S29WS-P_00_A12 S29WS-P 5
Data Sheet
11.8 CLK Characterization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
11.9 AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
11.10 Erase and Programming Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
12. Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
12.1 Common Flash Memory Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
13. Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
6 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Figures
Figure 4.1 84-Ball Fine-Pitch Ball Grid Array, 512, 256 & 128 Mb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 4.2 VBH084—84-ball Fine-Pitch Ball Grid Array, 11.6 x 8 mm MCP Compatible Package. . . . . 13
Figure 7.1 Synchronous/Asynchronous State Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 7.2 Synchronous Read Flow Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 7.3 Single Word Program. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 7.4 Write Buffer Programming Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Figure 7.5 Sector Erase Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Figure 7.6 Write Operation Status Flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Figure 8.1 Advanced Sector Protection/Unprotection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Figure 8.2 PPB Program/Erase Algorithm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Figure 8.3 Lock Register Program Algorithm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Figure 11.1 Maximum Negative Overshoot Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Figure 11.2 Maximum Positive Overshoot Waveform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Figure 11.3 Test Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Figure 11.4 Input Waveforms and Measurement Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Figure 11.5 VCC Power-up Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Figure 11.6 CLK Characterization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Figure 11.7 8-Word Linear Synchronous Single Data Rate Burst with Wrap Around . . . . . . . . . . . . . . . . 71
Figure 11.8 8-word Linear Single Data Read Synchronous Burst without Wrap Around . . . . . . . . . . . . . 71
Figure 11.9 Asynchronous Read Mode (AVD# Toggling - Case 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Figure 11.10 Asynchronous Read Mode (AVD# Toggling - Case 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Figure 11.11 Asynchronous Read Mode (AVD# Toggling - Case 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Figure 11.12 Asynchronous Read Mode (AVD# tied to CE#) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Figure 11.13 Asynchronous Page Mode Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Figure 11.14 Reset Timings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Figure 11.15 Asynchronous Program Operation Timings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Figure 11.16 Synchronous Program Operation Timings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Figure 11.17 Chip/Sector Erase Command Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Figure 11.18 Accelerated Unlock Bypass Programming Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Figure 11.19 Data# Polling Timings (During Embedded Algorithm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Figure 11.20 Toggle Bit Timings (During Embedded Algorithm). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Figure 11.21 Synchronous Data Polling Timings/Toggle Bit Timings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Figure 11.22 DQ2 vs. DQ6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Figure 11.23 Latency with Boundary Crossing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Figure 11.24 Wait State Configuration Register Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Figure 11.25 Back-to-Back Read/Write Cycle Timings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
January 28, 2008 S29WS-P_00_A12 S29WS-P 7
Data Sheet
Tables
Table 2.1 Input/Output Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Table 6.1 S29WS512P Sector & Memory Address Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Table 6.2 S29WS256P Sector & Memory Address Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Table 6.3 S29WS128P Sector & Memory Address Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Table 7.1 Device Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Table 7.2 Page Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Table 7.3 Address Latency for 11 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Table 7.4 Address Latency for 10 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Table 7.5 Address Latency for 09 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Table 7.6 Address Latency for 8 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Table 7.7 Address Latency for 7 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Table 7.8 Address Latency for 6 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Table 7.9 Address Latency for 5 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Table 7.10 Address Latency for 4 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Table 7.11 Address Latency for 3 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Table 7.12 Address Latency for 11 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Table 7.13 Address Latency for 10 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Table 7.14 Address Latency for 9 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Table 7.15 Address Latency for 8 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Table 7.16 Address Latency for 7 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Table 7.17 Address Latency for 6 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Table 7.18 Address Latency for 5 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Table 7.19 Address Latency for 4 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Table 7.20 Address Latency for 3 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Table 7.21 Address Latency for 11 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Table 7.22 Address Latency for 10 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Table 7.23 Address Latency for 9 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Table 7.24 Address Latency for 8 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Table 7.25 Address Latency for 7 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Table 7.26 Address Latency for 6 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Table 7.27 Address Latency for 5 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Table 7.28 Address Latency for 4 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Table 7.29 Address Latency for 3 Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Table 7.30 Burst Address Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Table 7.31 Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Table 7.32 Autoselect Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Table 7.33 Autoselect Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Table 7.34 Autoselect Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Table 7.35 Single Word Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Table 7.36 Write Buffer Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Table 7.37 Program Suspend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Table 7.38 Program Resume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Table 7.39 Sector Erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Table 7.40 Chip Erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Table 7.41 Erase Suspend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Table 7.42 Erase Resume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Table 7.43 Unlock Bypass Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Table 7.44 Unlock Bypass Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Table 7.45 Unlock Bypass Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Table 7.46 DQ6 and DQ2 Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Table 7.47 Write Operation Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
Table 7.48 Reset (LLD Function = lld_ResetCmd) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Table 8.1 Sector Protection Schemes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
Table 8.2 Lock Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
8 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Table 8.3 S29WS512P Sector Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Table 8.4 S29WS256P Sector Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Table 8.5 S29WS128P Sector Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Table 10.1 Secured Silicon Sector Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Table 10.2 Secured Silicon Sector Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Table 10.3 Secured Silicon Sector Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Table 10.4 Secured Silicon Sector Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Table 11.1 CMOS Compatible . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Table 11.2 Test Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Table 11.3 VCC Power-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Table 11.4 Non-Continuous Burst Mode with Wrap Around Burst Mode. . . . . . . . . . . . . . . . . . . . . . . . . .70
Table 11.5 Continuous Burst Mode with No Wrap Around Burst Mode. . . . . . . . . . . . . . . . . . . . . . . . . . .70
Table 11.6 Hardware Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
Table 11.7 Example of Programmable Wait States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82
Table 12.1 Memory Array Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84
Table 12.2 Sector Protection Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86
Table 12.3 CFI Query Identification String . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
Table 12.4 System Interface String . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
Table 12.5 Device Geometry Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
Table 12.6 Primary Vendor-Specific Extended Query . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
January 28, 2008 S29WS-P_00_A12 S29WS-P 9
Data Sheet
1. Ordering Information
The ordering part number is formed by a valid combination of the following:
1.1 Valid Combinations
Valid Combinations list configurations planned to be supported in volume for this device. Consult your local
sales office to confirm availability of specific valid combinations and to check on newly released
combinations.
Notes:
1. Type 0 is standard. Specify other options as required.
2. BGA package marking omits leading S29 and packing type designator from ordering part number.
S29WS 512 P xx BA W 00 0
Packing Type
0 = Tray (standard; see note 1)
2 = 7-inch Tape and Reel
3 = 13-inch Tape and Reel
Model Number
(Chip Enable Options)
00 = Default
Temperature Range
W = Wireless (–25°C to +85°C)
Package Type And Material
BA = Very Thin Fine-Pitch BGA, Lead (Pb)-free Compliant Package
BF = Very Thin Fine-Pitch BGA, Lead (Pb)-free Package
Speed Option (Burst Frequency)
0L = 54 MHz
0P = 66 MHz
0S = 80 MHz
AB = 104 MHz
Process Technology
P = 90 nm MirrorBit®Te c h n o l o g y
Flash Density
512= 512 Mb
256= 256 Mb
128= 128 Mb
Device Family
S29WS =1.8 Volt-only Simultaneous Read/Write, Burst Mode Flash Memory
S29WS512P Valid Combinations (Notes 1, 2)
Model
Numbers
Package Type
(Note 2)
Base Ordering
Part Number
Product
Status
Speed
Option
Package Type, Material, &
Temperature Range
Packing
Type
S29WS512P
Advance 0L, 0P,
0S, AB
BAW (
Lead (Pb)-free
Compliant),
BFW (
Lead (Pb)-free)
0, 2, 3
(Note 1) 00
11.6 mm x 8 mm
84-ball
MCP-Compatible
S29WS256P
S29WS128P
11.6 mm x 8 mm
84-ball
MCP-Compatible
10 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
2. Input/Output Descriptions & Logic Symbol
Table identifies the input and output package connections provided on the device.
Table 2.1 Input/Output Descriptions
Symbol Type Description
AMAX–A0 Input Address lines (Amax = 24 for WS512P 1CE# option, 23 for WS512P 2CE# option, 23 for WS256P, and
22 for WS128P)
DQ15–DQ0 I/O Data input/output.
CE# Input Chip Enable. Asynchronous relative to CLK.
OE# Input Output Enable. Asynchronous relative to CLK.
WE# Input Write Enable.
VCC Supply Device Power Supply
VCCQ Supply Device Input/Output Power Supply (Must be ramped simultaneously with VCC)
VSS Supply Ground.
NC No Connect Not connected internally.
RDY Output Ready. Indicates when valid burst data is ready to be read.
CLK Input Clock Input. In burst mode, after the initial word is output, subsequent active edges of CLK increment
the internal address counter. Should be at VIL or VIH while in asynchronous mode.
AVD# Input
Address Valid. Indicates to device that the valid address is present on the address inputs.
When low during asynchronous mode, indicates valid address; when low during burst mode, causes
starting address to be latched at the next active clock edge.
When high, device ignores address inputs.
RESET# Input Hardware Reset. Low = device resets and returns to reading array data.
WP# Input Write Protect. At VIL, disables program and erase functions in the four outermost sectors. Should be at
VIH for all other conditions.
ACC Input Acceleration Input. At VHH, accelerates programming; automatically places device in unlock bypass
mode. At VIL, disables all program and erase functions. Should be at VIH for all other conditions.
RFU Reserved Reserved for future use (see MCP look-ahead pinout for use with MCP).
January 28, 2008 S29WS-P_00_A12 S29WS-P 11
Data Sheet
3. Block Diagrams
Notes:
1. AMAX-A0 = A24-A0 for the WS512P, A23-A0 for the WS256P, and A22-A0 for the WS128P.
2. n = 15 for WS512P / WS256P / WS128P.
4. Physical Dimensions/Connection Diagrams
This section shows the I/O designations and package specifications for the S29WS-P.
4.1 Related Documents
The following documents contain information relating to the S29WS-P devices. Click on the title or go to
www.spansion.com to download the PDF file, or request a copy from your sales office.
Considerations for X-ray Inspection of Surface-Mounted Flash Integrated Circuits
4.2 Special Handling Instructions for FBGA Package
Special handling is required for Flash Memory products in FBGA packages.
Flash memory devices in FBGA packages may be damaged if exposed to ultrasonic cleaning methods. The
package and/or data integrity may be compromised if the package body is exposed to temperatures above
150°C for prolonged periods of time.
V
SS
V
CC
Bank Address
RESET#
ACC
WE#
CEx#
AVD#
RDY
DQ15–DQ0
WP#
S TAT E
CONTROL
&
COMMAND
REGISTER
Bank 1
X-Decoder
Y-Decoder
Latches and
Control Logic
Bank 0
X-Decoder
Y-Decoder
Latches and
Control Logic
DQ15–DQ0
DQ15–DQ0
DQ15–DQ0
DQ15–DQ0
DQ15–DQ0
Bank (n-1)
Y-Decoder
X-Decoder
Latches and
Control Logic
Bank (n)
Y-Decoder
X-Decoder
Latches and
Control Logic
OE#
Status
Control
AMAX–A0
AMAX–A0
AMAX–A0
AMAX–A0
Bank Address
Bank Address
Bank Address
V
CCQ
12 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Figure 4.1 84-Ball Fine-Pitch Ball Grid Array, 512, 256 & 128 Mb
Notes:
1. Balls F6 and G8 are RFU on the WS128P.
2. Ball G8 is RFU on the WS256P.
3. VCC pins must ramp simultaneously.
H4 H5 H6 H7 H8 H2
G7 G8 G9
F7 F8 F9
E7 E8 E9
D7 D8 D9
C5
H2
H2
C6 C7
F-CE#
H3
OE#
RFU DQ0
C2 C3
B2 B3
AVD# VSS
WP# A7 A8WE#ACCRFU
B4 B5 B6 B7
C8 C9
RFUA11
B8 B9
RFURFURFUVCCRFUCLK
A15A12A19
A21A13A9
A22A14A10
A16A24DQ6
G6
F6
E6
RFU
A20
A23
RFU
G4 G5
F4 F5
E4 E5
D5
RESET#RFU
RDYA18
RFUA17
RFUDQ1
RFUDQ15DQ13DQ4DQ3DQ9
DQ7RFUVCCDQ10
G2 G3
F2 F3
E2 E3
D2 D3
A6A3
A5A2
A4A1
VSSA0
L2 L3
RFU DQ8
RFU RFU
VSSDQ12
RFUDQ14DQ5RFUDQ11DQ2
L4 L5 L6 L7 L8 L9
VCCQRFURFUVCCVSS
A1
NC
A10
NC
RFU
M10
NC
M1
NC
H2
C4
D4 D6
Reserved fo
r
Future Use
Do Not Use
Ground
J4 J5 J6 J7 J8 J9
J2 J3
K2 K3 K4 K5 K6 K7 K8 K9
Power
Legend
(Top View, Balls Facing Down, MCP Compatible)
January 28, 2008 S29WS-P_00_A12 S29WS-P 13
Data Sheet
Figure 4.2 VBH084—84-ball Fine-Pitch Ball Grid Array, 11.6 x 8 mm MCP Compatible Package
Note:
BSC is an ANSI standard for Basic Space Centering.
4.3 MCP Look-ahead Connection Diagram
Spansion Inc. provides this standard look-ahead connection diagram that supports
NOR Flash and SRAM densities up to 4 Gigabits
NOR Flash and pSRAM densities up to 4 Gigabits
NOR Flash and pSRAM and data storage densities up to 4 Gigabits
The physical package outline may vary between connection diagrams and densities. The connection diagram
for any MCP, however, is a subset of the pinout.
3339 \ 16-038.25b
NOTES:
1. DIMENSIONING AND TOLERANCING PER ASME Y14.5M-1994.
2. ALL DIMENSIONS ARE IN MILLIMETERS.
3. BALL POSITION DESIGNATION PER JESD 95-1, SPP-010 (EXCEPT
AS NOTED).
4. e REPRESENTS THE SOLDER BALL GRID PITCH.
5. SYMBOL "MD" IS THE BALL ROW MATRIX SIZE IN THE
"D" DIRECTION.
SYMBOL "ME" IS THE BALL COLUMN MATRIX SIZE IN THE
"E" DIRECTION.
N IS THE TOTAL NUMBER OF SOLDER BALLS.
6 DIMENSION "b" IS MEASURED AT THE MAXIMUM BALL
DIAMETER IN A PLANE PARALLEL TO DATUM C.
7 SD AND SE ARE MEASURED WITH RESPECT TO DATUMS
A AND B AND DEFINE THE POSITION OF THE CENTER
SOLDER BALL IN THE OUTER ROW.
WHEN THERE IS AN ODD NUMBER OF SOLDER BALLS IN
THE OUTER ROW PARALLEL TO THE D OR E DIMENSION,
RESPECTIVELY, SD OR SE = 0.000.
WHEN THERE IS AN EVEN NUMBER OF SOLDER BALLS IN
THE OUTER ROW, SD OR SE = e/2
8. NOT USED.
9. "+" INDICATES THE THEORETICAL CENTER OF DEPOPULATED
BALLS.
10 A1 CORNER TO BE IDENTIFIED BY CHAMFER, LASER OR INK
MARK, METALLIZED MARK INDENTATION OR OTHER MEANS.
PACKAGE VBH 084
JEDEC N/A
11.60 mm x 8.00 mm NOM
PACKAGE
SYMBOL MIN NOM MAX NOTE
A --- --- 1.00 OVERALL THICKNESS
A1 0.18 --- --- BALL HEIGHT
A2 0.62 --- 0.76 BODY THICKNESS
D 11.60 BSC. BODY SIZE
E 8.00 BSC. BODY SIZE
D1 8.80 BSC. BALL FOOTPRINT
E1 7.20 BSC. BALL FOOTPRINT
MD 12 ROW MATRIX SIZE D DIRECTION
ME 10 ROW MATRIX SIZE E DIRECTION
N 84 TOTAL BALL COUNT
φb 0.33 --- 0.43 BALL DIAMETER
e 0.80 BSC. BALL PITCH
SD / SE 0.40 BSC. SOLDER BALL PLACEMENT
(A2-A9, B10-L10, DEPOPULATED SOLDER BALLS
M2-M9, B1-L1)
BOTTOM VIEW
TOP VIEW
SIDE VIEW
A1 CORNER
A2
A
10
9
10
ML JK
e
C0.05
(2X)
(2X)
C0.05
A1
E
D
7
BACEDFHG
8
7
6
5
4
3
2
1
e
D1
E1
SE
7
BCA
C
M
φ 0.15
φ 0.08 M
6
0.10 C
C0.08
NXφb
SD
A
B
C
SEATING PLANE
A1 CORNER
INDEX MARK
14 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
In some cases, outrigger balls may exist in locations outside the grid shown. These outrigger balls are
reserved; do not connect them to any other signal.
For further information about the MCP look-ahead pinout, refer to the Design-In Scalable Wireless Solutions
with Spansion Products application note (publication number: Design_Scalable_Wireless_AN), available on
the web or through a Spansion sales office.
January 28, 2008 S29WS-P_00_A12 S29WS-P 15
Data Sheet
5. Additional Resources
Visit www.spansion.com to obtain the following related documents:
Application Notes
Using the Operation Status Bits in AMD Devices
Understanding Burst Mode Flash Memory Devices
Simultaneous Read/Write vs. Erase Suspend/Resume
MirrorBit® Flash Memory Write Buffer Programming and Page Buffer Read
Design-In Scalable Wireless Solutions with Spansion Products
Common Flash Interface Version 1.4 Vendor Specific Extensions
Specification Bulletins
Contact your local sales office for details.
Drivers and Software Support
Spansion low-level drivers
True Flash File System
CAD Modeling Support
VHDL and Verilog
IBIS
ORCAD® Schematic Symbols
Technical Support
Contact your local sales office or contact Spansion Inc. directly for additional technical support:
http://www.spansion.com/flash_memory_products/support/ses/index.html
Spansion Inc. Locations
915 DeGuigne Drive, P.O. Box 3453
Sunnyvale, CA 94088-3453, USA
Telephone: 408-962-2500 or
1-866-SPANSION
Spansion Japan Limited
Cube-Kawasaki 9F/10F,
1-14 Nisshin-cho, Kawasaki-ku, Kawasaki-shi, Kanagawa, 210-0024, Japan
Phone: 044-223-1700 (active from Nov.28th)
http://www.spansion.com
16 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
6. Product Overview
The S29WS-P family consists of 512, 256, and 128 Mbit, 1.8 volts-only, simultaneous read/write burst mode
Flash device optimized for today’s wireless designs that demand a large storage array, rich functionality, and
low power consumption.
These devices are organized in 32, 16, or 8 Mwords of 16 bits each and are capable of continuous,
synchronous (burst) read or linear read (8-, 16-, or 32-word aligned group) with or without wrap around.
These products also offer single word programming or a 32-word buffer for programming with program/erase
and suspend functionality. Additional features include:
Advanced Sector Protection methods for protecting sectors as required
256 words of Secured Silicon area for storing customer and factory secured information. The Secured
Silicon Sector is One Time Programmable.
6.1 Memory Map
The S29WS512/256/128P Mbit devices consist of 16 banks organized as shown in Tables 6.16.3.
Note
This table has been condensed to show sector-related information for an entire device on a single page. Sectors and their address ranges
that are not explicitly listed (such as SA005–SA033) have sector starting and ending addresses that form the same pattern as all other
sectors of that size. For example, all 128 KB sectors have the pattern xx00000h–xxFFFFh.
Table 6.1 S29WS512P Sector & Memory Address Map
Bank
Size
Sector
Count
Sector Size
(KB) Bank
Sector/
Sector Range Address Range Notes
4 MB
4
32
0
SA000 000000h–003FFFh
Sector Starting Address –
Sector Ending Address
32 SA001 004000h–007FFFh
32 SA002 008000h–00BFFFh
32 SA003 00C000h–00FFFFh
31
128 SA004 010000h–01FFFFh Sector Starting Address –
Sector Ending Address
(see note)
128 SA034 1F0000h–1FFFFFh
4 MB 32 128 1 SA035–SA066 200000h–3FFFFFh
First Sector, Starting Address –
Last Sector, Ending Address
(see note)
4 MB 32 128 2 SA067–SA098
4 MB 32 128 3 SA099–SA130
4 MB 32 128 4 SA131–SA162
4 MB 32 128 5 SA163–SA194
4 MB 32 128 6 SA195–SA226
4 MB 32 128 7 SA227–SA258 E00000h–FFFFFFh
4 MB 32 128 8 SA259–SA290 1000000-11FFFFF
4 MB 32 128 9 SA291–SA322
4 MB 32 128 10 SA323–SA354
4 MB 32 128 11 SA355–SA386
4 MB 32 128 12 SA387–SA418
4 MB 32 128 13 SA419–SA450
4 MB 32 128 14 SA451–SA482 1C00000h-1DFFFFFh
4 MB
31 128
15
SA483 1E00000h-1E0FFFFh Sector Starting Address –
Sector Ending Address
(see note)
SA513 1FE0000h-1FEFFFFh
432
SA514 1FF0000h-1FF3FFFh
Sector Starting Address –
Sector Ending Address
SA515 1FF4000h-1FF7FFFh
SA516 1FF8000h-1FFBFFFh
SA517 1FFC000h-1FFFFFFh
January 28, 2008 S29WS-P_00_A12 S29WS-P 17
Data Sheet
Note
This table has been condensed to show sector-related information for an entire device on a single page. Sectors and their address ranges
that are not explicitly listed (such as SA005–SA017) have sector starting and ending addresses that form the same pattern as all other
sectors of that size. For example, all 128 KB sectors have the pattern xx00000h–xxFFFFh.
Table 6.2 S29WS256P Sector & Memory Address Map
Bank
Size
Sector
Count
Sector
Size (KB) Bank
Sector/
Sector Range Address Range Notes
2 MB 432
0
SA000 000000h–003FFFh
Contains four smaller
sectors at bottom of
addressable memory.
SA001 004000h–007FFFh
SA002 008000h–00BFFFh
SA003 00C000h–00FFFFh
15 128 SA004 to SA018 010000h–01FFFFh to 0F0000h–0FFFFFh
All 128 KB sectors.
Pattern for sector
address range is
xx0000h–xxFFFFh.
(see note)
2 MB 16 128 1 SA019 to SA034 100000h–10FFFFh to 1F0000h–1FFFFFh
2 MB 16 128 2 SA035 to SA050 200000h–20FFFFh to 2F0000h–2FFFFFh
2 MB 16 128 3 SA051 to SA066 300000h–30FFFFh to 3F0000h–3FFFFFh
2 MB 16 128 4 SA067 to SA082 400000h–40FFFFh to 4F0000h–4FFFFFh
2 MB 16 128 5 SA083 to SA098 500000h–50FFFFh to 5F0000h–5FFFFFh
2 MB 16 128 6 SA099 to SA114 600000h–60FFFFh to 6F0000h–6FFFFFh
2 MB 16 128 7 SA115 to SA130 700000h–70FFFFh to 7F0000h–7FFFFFh
2 MB 16 128 8 SA131 to SA146 800000h–80FFFFh to 8F0000h–8FFFFFh
2 MB 16 128 9 SA147 to SA162 900000h–90FFFFh to 9F0000h–9FFFFFh
2 MB 16 128 10 SA163 to SA178 A00000h–A0FFFFh to AF0000h–AFFFFFh
2 MB 16 128 11 SA179 to SA194 B00000h–B0FFFFh to BF0000h–BFFFFFh
2 MB 16 128 12 SA195 to SA210 C00000h–C0FFFFh to CF0000h–CFFFFFh
2 MB 16 128 13 SA211 to SA226 D00000h–D0FFFFh to DF0000h–DFFFFFh
2 MB 16 128 14 SA227 to SA242 E00000h–E0FFFFh to EF0000h–EFFFFFh
2 MB
15 128
15
SA243 to SA257 F00000h–F0FFFFh to FE0000h–FEFFFFh
432
SA258 FF0000h–FF3FFFh
Contains four smaller
sectors at top of
addressable memory.
SA259 FF4000h–FF7FFFh
SA260 FF8000h–FFBFFFh
SA261 FFC000h–FFFFFFh
18 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Note:
This table has been condensed to show sector-related information for an entire device on a single page. Sectors and their address ranges
that are not explicitly listed (such as SA005–SA009) have sector starting and ending addresses that form the same pattern as all other
sectors of that size. For example, all 128 KB sectors have the pattern xx00000h–xxFFFFh.
7. Device Operations
This section describes the read, program, erase, simultaneous read/write operations, handshaking, and reset
features of the Flash devices.
Operations are initiated by writing specific commands or a sequence with specific address and data patterns
into the command registers (see Table 12.1 on page 84 and Table 12.2 on page 86). The command register
itself does not occupy any addressable memory location; rather, it is composed of latches that store the
commands, along with the address and data information needed to execute the command. The contents of
the register serve as input to the internal state machine and the state machine outputs dictate the function of
the device. Writing incorrect address and data values or writing them in an improper sequence may place the
device in an unknown state, in which case the system must write the reset command to return the device to
the reading array data mode.
Table 6.3 S29WS128P Sector & Memory Address Map
Bank
Size
Sector
Count
Sector
Size (KB) Bank
Sector/
Sector Range Address Range Notes
1 MB 4
32
0
SA000 000000h–003FFFh
Contains four smaller
sectors at bottom of
addressable memory.
32 SA001 004000h–007FFFh
32 SA002 008000h–00BFFFh
32 SA003 00C000h–00FFFFh
7 128 SA004 to SA010 010000h–01FFFFh to 070000h–07FFFFh
All 128 KB sectors.
Pattern for sector address
range is xx0000h–xxFFFFh.
(see note)
1 MB 8 128 1 SA011 to SA018 080000h–08FFFFh to 0F0000h–0FFFFFh
1 MB 8 128 2 SA019 to SA026 100000h–10FFFFh to 170000h–17FFFFh
1 MB 8 128 3 SA027 to SA034 180000h–18FFFFh to 1F0000h–1FFFFFh
1 MB 8 128 4 SA035 to SA042 200000h–20FFFFh to 270000h–27FFFFh
1 MB 8 128 5 SA043 to SA050 280000h–28FFFFh to 2F0000h–2FFFFFh
1 MB 8 128 6 SA051 to SA058 300000h–30FFFFh to 370000h–37FFFFh
1 MB 8 128 7 SA059 to SA066 380000h–38FFFFh to 3F0000h–3FFFFFh
1 MB 8 128 8 SA067 to SA074 400000h–40FFFFh to 470000h–47FFFFh
1 MB 8 128 9 SA075 to SA082 480000h–48FFFFh to 4F0000h–4FFFFFh
1 MB 8 128 10 SA083 to SA090 500000h–50FFFFh to 570000h–57FFFFh
1 MB 8 128 11 SA091 to SA098 580000h–58FFFFh to 5F0000h–5FFFFFh
1 MB 8 128 12 SA099 to SA106 600000h–60FFFFh to 670000h–67FFFFh
1 MB 8 128 13 SA107 to SA114 680000h–68FFFFh to 6F0000h–6FFFFFh
1 MB 8 128 14 SA115 to SA122 700000h–70FFFFh to 770000h–77FFFFh
1 MB
7128
15
SA123 to SA129 780000h–78FFFFh to 7E0000h–7EFFFFh
4
32 SA130 7F0000h–7F3FFFh
Contains four smaller
sectors at top of
addressable memory.
32 SA131 7F4000h–7F7FFFh
32 SA132 7F8000h–7FBFFFh
32 SA133 7FC000h–7FFFFFh
January 28, 2008 S29WS-P_00_A12 S29WS-P 19
Data Sheet
7.1 Device Operation Table
The device must be setup appropriately for each operation. Table 7.1 describes the required state of each
control pin for any particular operation.
Legend:
L = Logic 0, H = Logic 1, X = can be either VIL or VIH., = rising edge, = high to low, = toggle.
Note:
Address is latched on the rising edge of clock.
7.2 Asynchronous Read
All memories require access time to output array data. In an asynchronous read operation, data is read from
one memory location at a time. Addresses are presented to the device in random order, and the propagation
delay through the device causes the data on its outputs to arrive asynchronously with the address on its
inputs.
The device defaults to reading array data asynchronously after device power-up or hardware reset. To read
data from the memory array, the system must first assert a valid address on Amax–A0, while driving AVD#
and CE# to VIL. WE# must remain at VIH. The rising edge of AVD# latches the address, preventing changes
to the address lines from effecting the address being accessed.. Data is output on DQ15-DQ0 pins after the
access time (tACC) has elapsed from the falling edge of AVD#, or the last time the address lines changed
while AVD# was low.
Table 7.1 Device Operations
Operation CE# OE# WE# CLK AVD# Amax–A0 DQ15–0 RDY RESET#
Asynchronous Read
- Addresses Latched LL H X Addr InOutput
Valid HH
Asynchronous Read
AVD# Steady State LL H X L Addr InOutput
Valid HH
Asynchronous Write L H X L Addr In Input
Valid HH
Synchronous Write LH L Addr In I/O H H
Standby (CE#) H X X X X X HIGH Z HIGH Z H
Hardware Reset X X X X X X HIGH Z HIGH Z
Burst Read Operations
Latch Starting Burst Address by CLK L X H L Addr In Output
Invalid XH
Advance Burst read to next address L L H H X Output
Valid HH
Terminate current Burst read cycle H X H X X X HIGH Z HIGH Z H
Terminate current Burst read cycle
via RESET# X X H X X X HIGH Z HIGH Z L
Terminate current Burst read cycle
and start new Burst read cycle LX H Addr InOutput
Invalid XH
20 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
7.3 Page Mode Read
The device is capable of fast page mode read. This mode provides fast (tPAC C ) random read access speed for
locations within a page. Address bits Amax–A3 select an 8 word page, and address bits A2–A0 select a
specific word within that page. This is an asynchronous operation with the microprocessor supplying the
specific word location. It does not matter if AVD# stays low or toggles. However, the address input must be
always valid and stable if AVD# is low during the page read.
The random or initial page access is tACC or tCE (depending on how the device was accessed) and
subsequent page read accesses (as long as the locations specified by the microprocessor falls within that
page) is equivalent to tPA C C . When CE# is deasserted (=VIH), the reassertion of CE# for subsequent access
has access time of tCE. Here again, CE# selects the device and OE# is the output control and should be used
to gate data to the output inputs if the device is selected. Fast page mode accesses are obtained by keeping
Amax–A3 constant and changing A2–A0 to select the specific word within that page.
7.4 Synchronous (Burst) Read Operation
The device is capable of continuous sequential burst operation and linear burst operation of a preset length.
When the device first powers up, it is enabled for asynchronous read operations and can be automatically
enabled for burst mode. To enter into synchronous mode, the configuration register will need to be set.
Prior to entering burst mode, the system should determine how many wait states are desired for the initial
word (tIACC) of each burst access, what mode of burst operation is desired and how the RDY signal will
transition with valid data. The system would then write the configuration register command sequence.
Once the system has written the Set Configuration Register command sequence, the device is enabled for
synchronous reads only.
The data is output tIACC after the rising edge of the first CLK. Subsequent words are output tBACC after the
rising edge of each successive clock cycle, which automatically increments the internal address counter.
Note that data is output only at the rising edge of the clock. RDY indicates the initial latency.
7.4.1 Latency Tables for Variable Wait State
The following tables show the latency for variable wait state in a continuous Burst operation
Table 7.2 Page Select
Word A2 A1 A0
Word 0 0 0 0
Word 1 0 0 1
Word 2 0 1 0
Word 3 0 1 1
Word 4 1 0 0
Word 5 1 0 1
Word 6 1 1 0
Word 7 1 1 1
Table 7.3 Address Latency for 11 Wait States
Word Initial Wait
0
11 ws
D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D124 D125 D126 D127 2 ws D0
1 D1D2D3D4D5D6D71 ws D8 D9 D10 D124 D125 D126 D127 2 ws D0
2 D2D3D4D5D6D71 ws 1 ws D8 D9 D10 D124 D125 D126 D127 2 ws D0
3 D3D4D5D6D71 ws 1 ws 1 ws D8 D9 D10 D124 D125 D126 D127 2 ws D0
4 D4D5D6D71 ws 1 ws 1 ws 1 ws D8 D9 D10 D124 D125 D126 D127 2 ws D0
5D5D6D71 ws 1 ws 1 ws 1 ws 1 ws D8 D9 D10 D124 D125 D126 D127 2 ws D0
6D6D71 ws 1 ws 1 ws 1 ws 1 ws 1 ws D8 D9 D10 D124 D125 D126 D127 2 ws D0
7D71 ws 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws D8 D9 D10 D124 D125 D126 D127 2 ws D0
January 28, 2008 S29WS-P_00_A12 S29WS-P 21
Data Sheet
Table 7.4 Address Latency for 10 Wait States
Word Initial Wait
0
10 ws
D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D124 D125 D126 D127 1 ws D0
1 D1D2D3D4D5D6D71 ws D8 D9 D10 D124 D125 D126 D127 1 ws D0
2 D2D3D4D5D6D71 ws 1 ws D8 D9 D10 D124 D125 D126 D127 1 ws D0
3 D3D4D5D6D71 ws 1 ws 1 ws D8 D9 D10 D124 D125 D126 D127 1 ws D0
4 D4D5D6D71 ws 1 ws 1 ws 1 ws D8 D9 D10 D124 D125 D126 D127 1 ws D0
5D5D6D71 ws 1 ws 1 ws 1 ws 1 ws D8 D9 D10 D124 D125 D126 D127 1 ws D0
6D6D71 ws 1 ws 1 ws 1 ws 1 ws 1 ws D8 D9 D10 D124 D125 D126 D127 1 ws D0
7D71 ws 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws D8 D9 D10 D124 D125 D126 D127 1 ws D0
Table 7.5 Address Latency for 09 Wait States
Word Initial Wait
0
9 ws
D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D124 D125 D126 D127 D0
1 D1D2D3D4D5D6D71 ws D8 D9 D10 D124 D125 D126 D127 D0
2 D2D3D4D5D6D71 ws 1 ws D8 D9 D10 D124 D125 D126 D127 D0
3 D3D4D5D6D71 ws 1 ws 1 ws D8 D9 D10 D124 D125 D126 D127 D0
4 D4D5D6D71 ws 1 ws 1 ws 1 ws D8 D9 D10 D124 D125 D126 D127 D0
5D5D6D71 ws 1 ws 1 ws 1 ws 1 ws D8 D9 D10 D124 D125 D126 D127 D0
6D6D71 ws 1 ws 1 ws 1 ws 1 ws 1 ws D8 D9 D10 D124 D125 D126 D127 D0
7D71 ws 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws D8 D9 D10 D124 D125 D126 D127 D0
Table 7.6 Address Latency for 8 Wait States
Word Initial Wait
0
8 ws
D0 D1 D2 D3 D4 D5 D6 D7 D8
1 D1D2D3D4D5D6D7D8 D9
2 D2D3D4D5D6D71 ws D8 D9
3 D3D4D5D6D71 ws 1 ws D8 D9
4 D4D5D6D71 ws 1 ws 1 ws D8 D9
5D5D6D71 ws 1 ws 1 ws 1 ws D8 D9
6D6D71 ws 1 ws 1 ws 1 ws 1 ws D8 D9
7D71 ws 1 ws 1 ws 1 ws 1 ws 1 ws D8 D9
Table 7.7 Address Latency for 7 Wait States
Word Initial Wait
0
7 ws
D0 D1 D2 D3 D4 D5 D6 D7 D8
1 D1D2D3D4D5D6D7D8 D9
2 D2D3D4D5D6D7D8D9 D10
3 D3 D4 D5 D6 D7 1 ws D8 D9 D10
4 D4D5D6D71 ws 1 ws D8 D9 D10
5D5D6D71 ws 1 ws 1 ws D8 D9 D10
6D6D71 ws 1 ws 1 ws 1 ws D8 D9 D10
7D71 ws 1 ws 1 ws 1 ws 1 ws D8 D9 D10
22 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Table 7.8 Address Latency for 6 Wait States
Word Initial Wait
0
6 ws
D0 D1 D2 D3 D4 D5 D6 D7 D8
1 D1D2D3D4D5D6D7D8 D9
2 D2D3D4D5D6D7D8D9 D10
3 D3D4D5D6D7D8D9D10D11
4 D4D5D6D71 ws D8 D9 D10 D11
5D5D6D71 ws 1 ws D8 D9 D10 D11
6D6D71 ws 1 ws 1 ws D8 D9 D10 D11
7D71 ws 1 ws 1 ws 1 ws D8 D9 D10 D11
Table 7.9 Address Latency for 5 Wait States
Word Initial Wait
0
5 ws
D0 D1 D2 D3 D4 D5 D6 D7 D8
1 D1D2D3D4D5D6D7D8 D9
2 D2D3D4D5D6D7D8D9 D10
3 D3D4D5D6D7D8D9D10D11
4 D4D5D6D7D8D9D10D11D12
5D5D6D71 ws D8 D9 D10 D11 D12
6D6D71 ws 1 ws D8 D9 D10 D11 D12
7D71 ws 1 ws 1 ws D8 D9 D10 D11 D12
Table 7.10 Address Latency for 4 Wait States
Word Initial Wait
0
4 ws
D0 D1 D2 D3 D4 D5 D6 D7 D8
1 D1D2D3D4D5D6D7D8 D9
2 D2D3D4D5D6D7D8D9 D10
3 D3D4D5D6D7D8D9D10D11
4 D4D5D6D7D8D9D10D11D12
5 D5D6D7D8D9D10D11D12D13
6D6D71 ws D8 D9 D10 D11 D12 D13
7D71 ws 1 ws D8 D9 D10 D11 D12 D13
Table 7.11 Address Latency for 3 Wait States
Word Initial Wait
0
3 ws
D0 D1 D2 D3 D4 D5 D6 D7 D8
1 D1D2D3D4D5D6D7D8 D9
2 D2D3D4D5D6D7D8D9 D10
3 D3D4D5D6D7D8D9D10D11
4 D4D5D6D7D8D9D10D11D12
5 D5D6D7D8D9D10D11D12D13
6 D6D7D8D9D10D11D12D13D14
7D71 ws D8 D9 D10 D11 D12 D13 D14
January 28, 2008 S29WS-P_00_A12 S29WS-P 23
Data Sheet
7.4.2 Latency for Boundary Crossing during First Read
The following tables show the latency at End of Word Line for boundary corssing during First Read in
continuous burst operation
Table 7.12 Address Latency for 11 Wait States
Word Initial Wait
0
11 ws
D120 D121 D122 D123 D124 D125 D126 D127 2 ws D0
1 D121 D122 D123 D124 D125 D126 D127 1 ws 2 ws D0
2 D122 D123 D124 D125 D126 D127 1 ws 1 ws 2 ws D0
3 D123 D124 D125 D126 D127 1 ws 1 ws 1 ws 2 ws D0
4 D124 D125 D126 D127 1 ws 1 ws 1 ws 1 ws 2 ws D0
5 D125 D126 D127 1 ws 1 ws 1 ws 1 ws 1 ws 2 ws D0
6 D126 D127 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws 2 ws D0
7 D127 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws 2 ws D0
Table 7.13 Address Latency for 10 Wait States
Word Initial Wait
0
10 ws
D120 D121 D122 D123 D124 D125 D126 D127 1 ws D0
1 D121 D122 D123 D124 D125 D126 D127 1 ws 1 ws D0
2 D122 D123 D124 D125 D126 D127 1 ws 1 ws 1 ws D0
3 D123 D124 D125 D126 D127 1 ws 1 ws 1 ws 1 ws D0
4 D124 D125 D126 D127 1 ws 1 ws 1 ws 1 ws 1 ws D0
5 D125 D126 D127 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws D0
6 D126 D127 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws D0
7D1271 ws 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws D0
Table 7.14 Address Latency for 9 Wait States
Word Initial Wait
0
9 ws
D120 D121 D122 D123 D124 D125 D126 D127 D0
1 D121 D122 D123 D124 D125 D126 D127 1 ws D0
2 D122 D123 D124 D125 D126 D127 1 ws 1 ws D0
3 D123 D124 D125 D126 D127 1 ws 1 ws 1 ws D0
4 D124 D125 D126 D127 1 ws 1 ws 1 ws 1 ws D0
5 D125 D126 D127 1 ws 1 ws 1 ws 1 ws 1 ws D0
6 D126 D127 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws D0
7 D127 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws D0
Table 7.15 Address Latency for 8 Wait States
Word Initial Wait
0
8 ws
D120 D121 D122 D123 D124 D125 D126 D127 D0
1 D121D122D123D124D125D126D127 D0 D1
2 D122D123D124D125D126D1271 ws D0 D1
3 D123D124D125D126D1271 ws 1 ws D0 D1
4 D124 D125 D126 D127 1 ws 1 ws 1 ws D0 D1
5 D125 D126 D127 1 ws 1 ws 1 ws 1 ws D0 D1
6 D126 D127 1 ws 1 ws 1 ws 1 ws 1 ws D0 D1
7D1271 ws 1 ws 1 ws 1 ws 1 ws 1 ws D0 D1
24 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Table 7.16 Address Latency for 7 Wait States
Word Initial Wait
0
7 ws
D120 D121 D122 D123 D124 D125 D126 D127 D0
1 D121 D122 D123 D124 D125 D126 D127 D0 D1
2 D122 D123 D124 D125 D126 D127 D0 D1 D2
3 D123 D124 D125 D126 D127 1 ws D0 D1 D2
4 D124 D125 D126 D127 1 ws 1 ws D0 D1 D2
5 D125 D126 D127 1 ws 1 ws 1 ws D0 D1 D2
6 D126 D127 1 ws 1 ws 1 ws 1 ws D0 D1 D2
7 D127 1 ws 1 ws 1 ws 1 ws 1 ws D0 D1 D2
Table 7.17 Address Latency for 6 Wait States
Word Initial Wait
0
6 ws
D120 D121 D122 D123 D124 D125 D126 D127 D0
1 D121 D122 D123 D124 D125 D126 D127 D0 D1
2 D122 D123 D124 D125 D126 D127 D0 D1 D2
3 D123 D124 D125 D126 D127 D0 D1 D2 D3
4 D124 D125 D126 D127 1 ws D0 D1 D2 D3
5 D125 D126 D127 1 ws 1 ws D0 D1 D2 D3
6 D126 D127 1 ws 1 ws 1 ws D0 D1 D2 D3
7 D127 1 ws 1 ws 1 ws 1 ws D0 D1 D2 D3
Table 7.18 Address Latency for 5 Wait States
Word Initial Wait
0
5 ws
D120 D121 D122 D123 D124 D125 D126 D127 D0
1 D121 D122 D123 D124 D125 D126 D127 D0 D1
2 D122 D123 D124 D125 D126 D127 D0 D1 D2
3 D123 D124 D125 D126 D127 D0 D1 D2 D3
4 D124 D125 D126 D127 D0 D1 D2 D3 D4
5 D125 D126 D127 1 ws D0 D1 D2 D3 D4
6 D126 D127 1 ws 1 ws D0 D1 D2 D3 D4
7D1271 ws 1 ws 1 ws D0 D1 D2 D3 D4
Table 7.19 Address Latency for 4 Wait States
Word Initial Wait
0
4 ws
D120 D121 D122 D123 D124 D125 D126 D127 D0
1 D121 D122 D123 D124 D125 D126 D127 D0 D1
2 D122 D123 D124 D125 D126 D127 D0 D1 D2
3 D123 D124 D125 D126 D127 D0 D1 D2 D3
4 D124 D125 D126 D127 D0 D1 D2 D3 D4
5 D125 D126 D127 D0 D1 D2 D3 D12 D5
6D126D1271 ws D0 D1 D2 D3 D12 D5
7D1271 ws 1 ws D0 D1 D2 D3 D12 D5
January 28, 2008 S29WS-P_00_A12 S29WS-P 25
Data Sheet
7.4.3 Latency at End of Word Line for Boundary Crossing After Second Read in
Continuous Burst Operation
The following tables show the latency for boundary crossing after Second Read in a continuous Burst
operation.
Table 7.20 Address Latency for 3 Wait States
Word Initial Wait
0
3 ws
D120 D121 D122 D123 D124 D125 D126 D127 D0
1 D121 D122 D123 D124 D125 D126 D127 D0 D1
2 D122 D123 D124 D125 D126 D127 D0 D1 D2
3 D123 D124 D125 D126 D127 D0 D1 D2 D3
4 D124 D125 D126 D127 D0 D1 D2 D3 D4
5 D125 D126 D127 D0 D1 D2 D3 D4 D5
6 D126 D127 D0 D1 D2 D3 D4 D5 D6
7 D127 1 ws D0 D1 D2 D3 D4 D5 D6
Table 7.21 Address Latency for 11 Wait States
Word Initial Wait
0
11 ws
D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 2 ws D0
1 D113 D114 D115 D116 D117 D118 D119 1 ws D120 D121 D122 D123 D124 D125 D126 D127 2 ws D0
2 D114 D115 D116 D117 D118 D119 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 2 ws D0
3 D115 D116 D117 D118 D119 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 2 ws D0
4 D116 D117 D118 D119 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 2 ws D0
5 D117 D118 D119 1 ws 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 2 ws D0
6 D118 D119 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 2 ws D0
7 D119 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 2 ws D0
Table 7.22 Address Latency for 10 Wait States
Word Initial Wait
0
10 ws
D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 1 ws D0
1 D113 D114 D115 D116 D117 D118 D119 1 ws D120 D121 D122 D123 D124 D125 D126 D127 1 ws D0
2 D114 D115 D116 D117 D118 D119 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 1 ws D0
3 D115 D116 D117 D118 D119 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 1 ws D0
4 D116 D117 D118 D119 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 1 ws D0
5 D117 D118 D119 1 ws 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 1 ws D0
6 D118 D119 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 1 ws D0
7 D119 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 1 ws D0
Table 7.23 Address Latency for 9 Wait States
Word Initial Wait
0
9 ws
D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
1 D113 D114 D115 D116 D117 D118 D119 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
2 D114 D115 D116 D117 D118 D119 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
3 D115 D116 D117 D118 D119 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
4 D116 D117 D118 D119 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
5 D117 D118 D119 1 ws 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
6 D118 D119 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
7D1191 ws 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
26 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Table 7.24 Address Latency for 8 Wait States
Word Initial Wait
0
8 ws
D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
1 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
2 D113 D114 D115 D116 D117 D118 D119 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
3 D114 D115 D116 D117 D118 D119 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
4 D115 D116 D117 D118 D119 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
5 D116 D117 D118 D119 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
6 D117 D118 D119 1 ws 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
7 D118 D119 1 ws 1 ws 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
Table 7.25 Address Latency for 7 Wait States
Word Initial Wait
0
7 ws
D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
1 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
2 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
3 D113 D114 D115 D116 D117 D118 D119 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
4 D114 D115 D116 D117 D118 D119 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
5 D115 D116 D117 D118 D119 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
6 D116 D117 D118 D119 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
7 D117 D118 D119 1 ws 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
Table 7.26 Address Latency for 6 Wait States
Word Initial Wait
0
6 ws
D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
1 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
2 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
3 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
4 D113 D114 D115 D116 D117 D118 D119 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
5 D114 D115 D116 D117 D118 D119 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
6 D115 D116 D117 D118 D119 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
7 D116 D117 D118 D119 1 ws 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
Table 7.27 Address Latency for 5 Wait States
Word Initial Wait
0
5 ws
D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
1 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
2 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
3 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
4 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
5 D113 D114 D115 D116 D117 D118 D119 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
6 D114 D115 D116 D117 D118 D119 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
7 D115 D116 D117 D118 D119 1 ws 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
January 28, 2008 S29WS-P_00_A12 S29WS-P 27
Data Sheet
Table 7.28 Address Latency for 4 Wait States
Word Initial Wait
0
4 ws
D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
1 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
2 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
3 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
4 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
5 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
6 D113 D114 D115 D116 D117 D118 D119 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
7 D114 D115 D116 D117 D118 D119 1 ws 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
Table 7.29 Address Latency for 3 Wait States
Word Initial Wait
0
4 ws
D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
1 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
2 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
3 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
4 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
5 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
6 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D126 D127 D0
7 D113 D114 D115 D116 D117 D118 D119 1 ws D120 D121 D122 D123 D124 D125 D126 D127 D0
28 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
7.5 Synchronous (Burst) Read Mode & Configuration Register
See Configuration Registers on page 31, and Table 12.1, Memory Array Commands on page 84, for further
details.
Figure 7.1 Synchronous/Asynchronous State Diagram
Power-up/
Hardware Reset
Asynchronous Read
Mode Only
Synchronous Read
Mode Only
Set Burst Mode
Configuration Register
Command for
Synchronous Mode
(CR15 = 0)
Set Burst Mode
Configuration Register
Command for
Asynchronous Mode
(CR15 = 1)
January 28, 2008 S29WS-P_00_A12 S29WS-P 29
Data Sheet
Figure 7.2 Synchronous Read Flow Chart
7.5.1 Continuous Burst Read Mode
In the continuous burst read mode, the device outputs sequential burst data from the starting address given
and then wraps around to address 000000h when it reaches the highest addressable memory location. The
burst read mode continues until the system drives CE# high, or RESET#= VIL. Continuous burst mode can
also be aborted by asserting AVD# low and providing a new address to the device.
If the address being read crosses a 128-word line boundary with in the same bank, but not into a program or
erase suspended sector (as mentioned above), additional latency cycles are required as reflected by the
configuration register table (Table 7.31).
If the address crosses a bank boundary while the subsequent bank is programming or erasing, the device
provides read status information and the clock is ignored. Upon completion of status read or program or erase
operation, the host can restart a burst read operation using a new address and AVD# pulse.
Write Unlock Cycles:
Address 555h, Data AAh
Address 2AAh, Data 55h
Write Set Configuration Register
Command and Settings:
Address 555h, Data D0h
Address X00h, Data CR
Load Initial Address
Address = RA
Read Initial Data
RD = DQ[15:0]
Read Next Data
RD = DQ[15:0]
Wait t
IACC
+
Programmable Wait State Setting
Wait X Clocks:
Additional Latency Due to Starting
Address, Clock Frequency, and
Boundary Crossing
End of Data?
Yes
Crossing
Boundary?
No
Yes
Completed
Delay X Clocks
Unlock Cycle 1
Unlock Cycle 2
RA = Read Address
RD = Read Data
Command Cycle
CR = Configuration Register Bits CR15-CR0
CR13-CR11 sets initial access time
(from address latched to
valid data) from 2 to 7 clock cycles
Note: Setup Configuration Register parameters
Refer to the Latency tables.
30 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
7.5.2 8-, 16-, 32-Word Linear Burst Read with Wrap Around
In a linear burst read operation, a fixed number of words (8, 16, or 32 words) are read from consecutive
addresses that are determined by the group within which the starting address falls. The groups are sized
according to the number of words read in a single burst sequence for a given mode (see Table 7.30).
For example, if the starting address in the 8-word mode is 3Ch, the address range to be read would be 38-
3Fh, and the burst sequence would be 3C-3D-3E-3F-38-39-3A-3Bh. Thus, the device outputs all words in that
burst address group until all word are read, regardless of where the starting address occurs in the address
group, and then terminates the burst read.
In a similar fashion, the 16-word and 32-word Linear Wrap modes begin their burst sequence on the starting
address provided to the device, then wrap back to the first address in the selected address group.
Note
In this mode the address pointer does not cross the boundary that occurs every 128 words; thus, no
additional wait states are inserted due to boundary crossing.
7.5.3 8-, 16-, 32-Word Linear Burst without Wrap Around
If wrap around is not enabled for linear burst read operations, the 8-word, 16-word, or 32-word burst executes
up to the maximum memory address of the selected number of words. The burst stops after 8, 16, or 32
addresses and does not wrap around to the first address of the selected group.
For example, if the starting address in the 8-word mode is 3Ch, the address range to be read would be 3Ch-
43h, and the burst sequence would be 3C-3D-3E-3F-40-41-42-43h if wrap around is not enabled. The next
address to be read requires a new address and AVD# pulse. Note that in this burst read mode, the address
pointer may cross the boundary that occurs every 128 words, which will incur the additional boundary
crossing wait state.
Table 7.30 Burst Address Groups
Mode Group Size Group Address Ranges
8-word 8 words 0-7h, 8-Fh, 10-17h,...
16-word 16 words 0-Fh, 10-1Fh, 20-2Fh,...
32-word 32 words 00-1Fh, 20-3Fh, 40-5Fh,...
January 28, 2008 S29WS-P_00_A12 S29WS-P 31
Data Sheet
7.5.4 Configuration Registers
This device uses two 16-bit configuration registers to set various operational parameters. Upon power-up or
hardware reset, the device defaults to the asynchronous read mode, and the configuration register settings
are in their default state. The host system should determine the proper settings for the entire configuration
register, and then execute the Set Configuration Register command sequence before attempting burst
operations. The Configuration Register can also be read using a command sequence (see Table 12.1
on page 84). The following list describes the register settings.
Notes:
1. Device will be in the Asynchronous Mode upon power-up or hardware reset.
2. CR1.0 to CR1.3 and CR1.5 to CR1.15 = 1 (Default).
3. CR0.3 is ignored if in continuous read mode (no warp around).
4. A software reset command is required after reading or writing the configuration registers in order to set the device back to array read
mode.
Table 7.31 Configuration Register
CR Bit Function Settings (Binary)
CR0.15 Set Device
Read Mode
0 = Synchronous Read (Burst Mode) Enabled
1 = Asynchronous Mode (Default)
CR0.14 Reserved (Not
used)
0 = Reserved
1 = Reserved (Default)
CR1.0
Programmable
Wait State
0000 = initial data is valid on the 2nd rising CLK edge after addresses are latched
0001 = initial data is valid on the 3rd rising CLK edge after addresses are latched
0010 = initial data is valid on the 4th rising CLK edge after addresses are latched
0011 = initial data is valid on the 5th rising CLK edge after addresses are latched
0100 = initial data is valid on the 6th rising CLK edge after addresses are latched
0101 = initial data is valid on the 7th rising CLK edge after addresses are latched
0110 = Reserved
0111 = Reserved
1000 = initial data is valid on the 8th rising CLK edge after addresses are latched
1001 = initial data is valid on the 9th rising CLK edge after addresses are latched
1010 = initial data is valid on the 10th rising CLK edge after addresses are latched
1011 = initial data is valid on the 11th rising CLK edge after addresses are latched
1100 = Reserved
1101 = default
1110 = Reserved
1111 = Reserved
CR0.13
CR0.12
CR0.11
CR0.10 RDY Polarity 0 = RDY signal is active low
1 = RDY signal is active high (Default)
CR0.9 Reserved (Not
used)
0 = Reserved
1 = Reserved (Default)
CR0.8 RDY 0 = RDY active one clock cycle before data
1 = RDY active with data (Default)
CR0.7 Reserved (Not
used)
0 = Reserved
1 = Reserved (Default)
CR0.6 Reserved 0 = Reserved
1 = Reserved (Default)
CR0.5 Reserved 0 = Reserved (Default)
1 = Reserved
CR0.4 RDY Function 0 = RDY (Default)
1 = Reserved
CR0.3 Burst Wrap
Around
0 = No Wrap Around Burst
1 = Wrap Around Burst (Default)
CR0.2
Burst Length
000 = Continuous (Default)
010 = 8-Word Linear Burst
011 = 16-Word Linear Burst
100 = 32-Word Linear Burst
(All other bit settings are reserved)
CR0.1
CR0.0
32 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
5. Refer to Table 12.1 on page 84 for reading the settings and writing onto configuration registers command sequences.
6. Configuration Registers can not be programmed out of order. CR0 must be programmed prior to CR01 otherwise the configuration
registers will retain their previous settings.
7.6 Autoselect
The Autoselect is used for manufacturer ID, Device identification, and sector protection information. This
mode is primarily intended for programming equipment to automatically match a device with its corresponding
programming algorithm. The Autoselect codes can also be accessed in-system. When verifying sector
protection, the sector address must appear on the appropriate highest order address bits (see Table 7.32
on page 32). The remaining address bits are don't care. The most significant four bits of the address during
the third write cycle selects the bank from which the Autoselect codes are read by the host. All other banks
can be accessed normally for data read without exiting the Autoselect mode.
To access the Autoselect codes, the host system must issue the Autoselect command.
The Autoselect command sequence may be written to an address within a bank that is either in the read or
erase-suspend-read mode.
The Autoselect command may not be written while the device is actively programming or erasing.
Autoselect does not support simultaneous operations or burst mode.
The system must write the reset command to return to the read mode (or erase-suspend-read mode if the
bank was previously in Erase Suspend).
See Table 12.1 on page 84 for command sequence details.
Table 7.32 Autoselect Addresses
Description Address Read Data
Manufacturer ID
Word 00 (BA) + 00h 0001h
Device ID,
Word 01 (BA) + 01h 227Eh
Sector Lock/Unlock
Word 02 (SA) + 02h 0001h = Locked,
0000h = Unlocked
Indicator Bits
Word 03 (BA) + 03h
DQ15 - DQ8 = reserved
DQ7 - Factory Lock Bit;
1 = Locked, 0 = Not Locked
DQ6 -Customer Lock Bit;
1 = Locked, 0 = Not Locked
DQ5 - Handshake Bit;
1 = Reserved,
0 = Standard Handshake
DQ4 & DQ3 - WP# Protection Boot Code;
00 = WP# Protects both Top Boot and Bottom Boot
Sectors,
DQ2 - DQ0 = reserved
Device ID,
Word 0E (BA) + 0Eh
223Dh (WS512P)-1CE#
2242h (WS256P)
2244h (WS128P)
Device ID,
Word 0F (BA) + 0Fh 2200h
January 28, 2008 S29WS-P_00_A12 S29WS-P 33
Data Sheet
Software Functions and Sample Code
Notes:
1. Any offset within the device works.
2. BA = Bank Address. The bank address is required.
3. base = base address.
The following is a C source code example of using the autoselect function to read the manufacturer ID. Refer
to the Spansion Low Level Driver User’s Guide for general information on Spansion Flash memory software
development guidelines.
/* Here is an example of Autoselect mode (getting manufacturer ID) */
/* Define UINT16 example: typedef volatile unsigned short UINT16; */
UINT16 manuf_id;
/* Auto Select Entry */
*( (UINT16 *)bank_addr + 0x555 ) = 0x00AA; /* write unlock cycle 1 */
*( (UINT16 *)bank_addr + 0x2AA ) = 0x0055; /* write unlock cycle 2 */
*( (UINT16 *)bank_addr + 0x555 ) = 0x0090; /* write autoselect command */
/* multiple reads can be performed after entry */
manuf_id = *( (UINT16 *)bank_addr + 0x000 ); /* read manuf. id */
/* Autoselect exit */
*( (UINT16 *)base_addr + 0x000 ) = 0x00F0; /* exit autoselect (write reset command) */
Table 7.33 Autoselect Entry
(LLD Function = lld_AutoselectEntryCmd)
Cycle Operation Byte Address Word Address Data
Unlock Cycle 1 Write BA+AAAh BA+555h 0x00AAh
Unlock Cycle 2 Write BA+555h BA+2AAh 0x0055h
Autoselect Command Write BA+AAAh BA+555h 0x0090h
Table 7.34 Autoselect Exit
(LLD Function = lld_AutoselectExitCmd)
Cycle Operation Byte Address Word Address Data
Unlock Cycle 1 Write xxxxh xxxxh 0x00F0h
34 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
7.7 Program/Erase Operations
These devices are capable of several modes of programming and or erase operations which are described in
detail in the following sections. However, prior to any programming and or erase operation, devices must be
setup appropriately as outlined in the configuration register (Table 7.31 on page 31).
During synchronous write operations, including writing command sequences, the system must drive AVD#
and CE# to VIL, and OE# to VIH when providing an address to the device, and drive WE# and CE# to VIL, and
OE# to VIH when writing commands or programming data. Addresses are latched on the rising edge of AVD#
pulse or rising edge of CLK or falling edge of WE#, whichever occurs first.
During asynchronous write operations, addresses are latched on the rising edge of AVD# or falling edge of
WE# while data is latched on the 1st rising edge of WE#, or CE# whichever comes first.
Note the following:
When the Embedded Program/Erase algorithm is complete, the device returns to the read mode.
The system can determine the status of the Program/Erase operation. Refer to Write Operation Status
on page 47 for further information.
While 1 can be programmed to 0, a 0 cannot be programmed to a 1. Any such attempt will be ignored as
only an erase operation can covert a 0 to a 1. For example:
Old Data = 0011
New Data = 0101
Result = 0001
Any commands written to the device during the Embedded Program/Erase Algorithm are ignored except
the Program/Erase Suspend commands.
Secured Silicon Sector, Autoselect, and CFI functions are unavailable when a Program/Erase operation is
in progress.
A hardware reset and/or power removal immediately terminates the Program/Erase operation and the
Program/Erase command sequence should be reinitiated once the device has returned to the read mode
to ensure data integrity.
Programming is allowed in any sequence and across sector boundaries only for single word programming
operation. See Write Buffer Programming on page 36 when using the write buffer.
January 28, 2008 S29WS-P_00_A12 S29WS-P 35
Data Sheet
7.7.1 Single Word Programming
Single word programming mode is the simplest method of programming. In this mode, four Flash command
write cycles are used to program an individual Flash address. While the single word programming method is
supported by all Spansion devices, in general it is not recommended for devices that support Write Buffer
Programming. See Table 12.1 on page 84 for the required bus cycles and Figure 7.3 for the flowchart.
When the Embedded Program algorithm is complete, the device returns to the read mode and addresses are
no longer latched. The system can determine the status of the program operation by using DQ7 or DQ6.
Refer to the Write Operation Status section for information on these status bits.
Figure 7.3 Single Word Program
Write Unlock Cycles:
Address 555h, Data AAh
Address 2AAh, Data 55h
Write Program Command:
Address 555h, Data A0h
Program Data to Address:
PA , P D
Unlock Cycle 1
Unlock Cycle 2
Setup Command
Program Address (PA),
Program Data (PD)
Operation failed
Perform Polling Algorithm
(see Write Operation Status
flowchart)
Ye s
Ye s
No
No
Polling Status
= Busy?
Polling Status
= completed
Error condition
(Exceeded Timing Limits)
Operation successfully completed
36 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Software Functions and Sample Code
Note:
Base = Base Address.
The following is a C source code example of using the single word program function. Refer to the Spansion
Low Level Driver User’s Guide (available on www.spansion.com) for general information on Spansion Flash
memory software development guidelines.
/* Example: Program Command */
*( (UINT16 *)base_addr + 0x555 ) = 0x00AA; /* write unlock cycle 1 */
*( (UINT16 *)base_addr + 0x2AA ) = 0x0055; /* write unlock cycle 2 */
*( (UINT16 *)base_addr + 0x555 ) = 0x00A0; /* write program setup command */
*( (UINT16 *)pa ) = data; /* write data to be programmed */
/* Poll for program completion */
7.7.2 Write Buffer Programming
Write Buffer Programming allows the system to write a maximum of 32 words in one programming operation.
This results in a faster effective word programming time than the standard word programming algorithms. The
Write Buffer Programming command sequence is initiated by first writing two unlock cycles. This is followed
by a third write cycle containing the Write Buffer Load command written at the Sector Address in which
programming will occur. At this point, the system writes the number of word locations minus 1 that will be
loaded into the page buffer at the Sector Address in which programming will occur. This tells the device how
many write buffer addresses will be loaded with data and therefore when to expect the Program Buffer to
Flash confirm command. The number of locations to program cannot exceed the size of the write buffer or the
operation will abort. (NOTE: the size of the write buffer is dependent upon which data are being loaded. Also
note that the number loaded = the number of locations to program minus 1. For example, if the system will
program 6 address locations, then 05h should be written to the device.)
The write-buffer addresses must be in the same sector for all address/data pairs loaded into the write buffer.
It is to be noted that Write Buffer Programming cannot be performed across multiple sectors. If the system
attempts to load programming data outside of the selected write-buffer addresses, the operation aborts after
the Write to Buffer command is executed. Also, the starting address must be the least significant address. All
subsequent addresses and write buffer data must be in sequential order.
The system then writes the starting address/data combination. This starting address is the first address/data
pair to be programmed, and selects the write-buffer-page address. All subsequent address/data pairs must
be in sequential order.
After writing the Starting Address/Data pair, the system then writes the remaining address/data pairs into the
write buffer. Write buffer locations must be loaded in sequential order starting with the lowest address in the
page. Note that if the number of address/data pairs do no match the word count, the program buffer to flash
command is ignored.
Note that if a Write Buffer address location is loaded multiple times, the address/data pair counter will be
decremented for every data load operation. Also, the last data loaded at a location before the Program Buffer
to Flash confirm command will be programmed into the device. It is the software’s responsibility to
comprehend ramifications of loading a write-buffer location more than once. The counter decrements for each
data load operation, NOT for each unique write-buffer-address location.
Once the specified number of write buffer locations have been loaded, the system must then write the
Program Buffer to Flash command at the Sector Address. Any other address/data write combinations will
abort the Write Buffer Programming operation. The device will then go busy. The Data Bar polling techniques
Table 7.35 Single Word Program
(LLD Function = lld_ProgramCmd)
Cycle Operation Byte Address Word Address Data
Unlock Cycle 1 Write Base + AAAh Base + 555h 00AAh
Unlock Cycle 2 Write Base + 554h Base + 2AAh 0055h
Program Setup Write Base + AAAh Base + 555h 00A0h
Program Write Word Address Word Address Data Word
January 28, 2008 S29WS-P_00_A12 S29WS-P 37
Data Sheet
should be used while monitoring the last address location loaded into the write buffer. This eliminates the
need to store an address in memory because the system can load the last address location, issue the
program confirm command at the last loaded address location, and then data bar poll at that same address.
DQ7, DQ6, DQ5, DQ2, and DQ1 should be monitored to determine the device status during Write Buffer
Programming.
The write-buffer embedded programming operation can be suspended using the standard suspend/resume
commands. Upon successful completion of the Write Buffer Programming operation, the device will return to
READ mode.
The Write Buffer Programming Sequence is ABORTED in the following ways:
Load a value that is greater than the buffer size during the Number of Locations to Program step (DQ7 is
not valid in this condition).
Write to an address in a sector different than the one specified during the Write-Buffer-Load command.
Write an Address/Data pair to a different write-buffer-page than the one selected by the Starting Address
during the write buffer data loading stage of the operation.
Write data other than the Confirm Command after the specified number of data load cycles.
Software Functions and Sample Code
Notes:
1. Base = Base Address.
2. Last = Last cycle of write buffer program operation; depending on number of words written, the total number of cycles may be
from 6 to 37.
3. For maximum efficiency, it is recommended that the write buffer be loaded with the highest number of words (N words) possible.
Table 7.36 Write Buffer Program
(LLD Functions Used = lld_WriteToBufferCmd, lld_ProgramBufferToFlashCmd)
Cycle Description Operation Byte Address Word Address Data
1 Unlock Write Base + AAAh Base + 555h 00AAh
2 Unlock Write Base + 554h Base + 2AAh 0055h
3 Write Buffer Load Command Write Program Address 0025h
4 Write Word Count Write Program Address Word Count (N–1)h
Number of words (N) loaded into the write buffer can be from 1 to 32 words.
5 to 36 Load Buffer Word N Write Program Address, Word N Word N
Last Write Buffer to Flash Write Sector Address 0029h
38 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
The following is a C source code example of using the write buffer program function. Refer to the Spansion
Low Level Driver User’s Guide (available on www.spansion.com) for general information on Spansion Flash
memory software development guidelines.
/* Example: Write Buffer Programming Command */
/* NOTES: Write buffer programming limited to 16 words. */
/* All addresses to be written to the flash in */
/* one operation must be within the same write buffer. */
/* A write buffer begins at addresses evenly divisible */
/* by 0x20.
UINT16 i; */
UINT16 *src = source_of_data; /* address of source data */
UINT16 *dst = destination_of_data; /* flash destination address */
UINT16 wc = words_to_program -1; /* word count (minus 1) */
*( (UINT16 *)base_addr + 0x555 ) = 0x00AA; /* write unlock cycle 1 */
*( (UINT16 *)base_addr + 0x2AA ) = 0x0055; /* write unlock cycle 2 */
*( (UINT16 *)dst ) = 0x0025; /* write write buffer load command */
*( (UINT16 *)dst ) = wc; /* write word count (minus 1) */
for (i=0;i<=wc;i++)
{
*dst++ = *src++; /* ALL dst MUST BE in same Write Buffer */
}
*( (UINT16 *)sector_address ) = 0x0029; /* write confirm command */
/* poll for completion */
/* Example: Write Buffer Abort Reset */
*( (UINT16 *)base_addr + 0x555 ) = 0x00AA; /* write unlock cycle 1 */
*( (UINT16 *)base_addr + 0x2AA ) = 0x0055; /* write unlock cycle 2 */
*( (UINT16 *)base_addr + 0x555 ) = 0x00F0; /* write buffer abort reset */
January 28, 2008 S29WS-P_00_A12 S29WS-P 39
Data Sheet
Figure 7.4 Write Buffer Programming Operation
7.7.3 Program Suspend/Program Resume Commands
The Program Suspend command allows the system to interrupt an embedded programming operation or a
Write to Buffer programming operation so that data can read from any non-suspended sector. When the
Program Suspend command is written during a programming process, the device halts the programming
operation within tPSL (program suspend latency). Bank address needs to be provided when writing the
Program Suspend Command. The status bits are undefined during the tPSL period. To verify that the device
is in the suspended state, either:
wait until after tPSL to check the status bits
perform a read and check that the status bits return array data
check whether any Autoselect commands are accepted.
After the programming operation has been suspended, the system can read array data from any non-
suspended sector. The Program Suspend command may also be issued during a programming operation
Write Unlock Cycles:
Address 555h, Data AAh
Address 2AAh, Data 55h
Issue
Write Buffer Load Command:
Program Address Data 25h
Load Word Count to Program
Program Data to Address:
SA = wc
Unlock Cycle 1
Unlock Cycle 2
wc = number of words – 1
Ye s
Ye s
Ye s
Ye s
No
No
No
No
wc = 0?
Write Buffer
Abort?
Polling Status
= Done?
Error?
FAIL. Issue reset command
to return to read array mode.
PASS. Device is in
read mode.
Confirm command:
29h
Perform Polling Algorithm
(see Write Operation Status
flowchart)
Write Next Word,
Decrement wc:
PA data , wc = wc – 1
RESET. Issue Write Buffer
Abort Reset Command
40 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
while an erase is suspended. In this case, data may be read from any addresses not in Erase Suspend or
Program Suspend. If a read is needed from the Secured Silicon Sector area, then user must use the proper
command sequences to enter and exit this region.
The system may also write the Autoselect command sequence when the device is in Program Suspend
mode. The device allows reading Autoselect codes in the suspended sectors, since the codes are not stored
in the memory array. When the device exits the Autoselect mode, the device reverts to Program Suspend
mode, and is ready for another valid operation. See Autoselect on page 32 for more information.
After the Program Resume command is written, the device reverts to programming. The system can
determine the status of the program operation using the DQ7 or DQ6 status bits, just as in the standard
program operation. See Write Operation Status on page 47 for more information.
Note: While a program operation can be suspended and resumed multiple times, a minimum delay of tPRS
(Program Resume to Suspend) is required from resume to the next suspend.
The system must write the Program Resume command (address bits are don't care) to exit the Program
Suspend mode and continue the programming operation. Further writes of the Program Resume command
are ignored. Another Program Suspend command can be written after the device has resumed programming.
Software Functions and Sample Code
The following is a C source code example of using the program suspend function. Refer to the Spansion Low
Level Driver User’s Guide (available on www.spansion.com) for general information on Spansion Flash
memory software development guidelines.
/* Example: Program suspend command */
*( (UINT16 *)base_addr + 0x000 ) = 0x00B0; /* write suspend command */
The following is a C source code example of using the program resume function. Refer to the Spansion Low
Level Driver User’s Guide (available on www.spansion.com) for general information on Spansion Flash
memory software development guidelines.
/* Example: Program resume command */
*( (UINT16 *)base_addr + 0x000 ) = 0x0030; /* write resume command */
7.7.4 Sector Erase
The sector erase function erases one or more sectors in the memory array (see Table 12.1 on page 84 and
Figure 7.5 on page 42). The device does not require the system to preprogram prior to erase. The Embedded
Erase algorithm automatically programs and verifies the entire memory for an all zero data pattern prior to
electrical erase. After a successful sector erase, all locations within the erased sector contain FFFFh. The
system is not required to provide any controls or timings during these operations.
After the command sequence is written, a sector erase time-out of no less than tSEA occurs. During the time-
out period, additional sector addresses and sector erase commands may be written. Loading the sector erase
buffer may be done in any sequence, and the number of sectors may be from one sector to all sectors. The
time between these additional cycles must be less than tSEA. Any sector erase address and command
following the exceeded time-out (tSEA) may or may not be accepted. Any command other than Sector Erase
or Erase Suspend during the time-out period resets that bank to the read mode. The system can monitor DQ3
to determine if the sector erase timer has timed out (see DQ3: Sector Erase Timeout State Indicator
on page 50). The time-out begins from the rising edge of the final WE# pulse in the command sequence.
Table 7.37 Program Suspend
(LLD Function = lld_ProgramSuspendCmd)
Cycle Operation Byte Address Word Address Data
1 Write Bank Address Bank Address 00B0h
Table 7.38 Program Resume
(LLD Function = lld_ProgramResumeCmd)
Cycle Operation Byte Address Word Address Data
1 Write Bank Address Bank Address 0030h
January 28, 2008 S29WS-P_00_A12 S29WS-P 41
Data Sheet
When the Embedded Erase algorithm is complete, the bank returns to reading array data and addresses are
no longer latched. Note that while the Embedded Erase operation is in progress, the system can read data
from the non-erasing banks. The system can determine the status of the erase operation by reading DQ7 or
DQ6/DQ2 in the erasing bank. Refer to Write Operation Status on page 47 for information on these status
bits.
Once the sector erase operation has begun, only the Erase Suspend command is valid. All other commands
are ignored. However, note that a hardware reset immediately terminates the erase operation. If that occurs,
the sector erase command sequence should be reinitiated once that bank has returned to reading array data,
to ensure data integrity.
Figure 7.5 on page 42 illustrates the algorithm for the erase operation. Refer to Program/Erase Operations
on page 34 for parameters and timing diagrams.
Software Functions and Sample Code
The following is a C source code example of using the sector erase function. Refer to the Spansion Low Level
Driver User’s Guide (available on www.spansion.com) for general information on Spansion Flash memory
software development guidelines.
/* Example: Sector Erase Command */
*( (UINT16 *)base_addr + 0x555 ) = 0x00AA; /* write unlock cycle 1 */
*( (UINT16 *)base_addr + 0x2AA ) = 0x0055; /* write unlock cycle 2 */
*( (UINT16 *)base_addr + 0x555 ) = 0x0080; /* write setup command */
*( (UINT16 *)base_addr + 0x555 ) = 0x00AA; /* write additional unlock cycle 1 */
*( (UINT16 *)base_addr + 0x2AA ) = 0x0055; /* write additional unlock cycle 2 */
*( (UINT16 *)sector_address ) = 0x0030; /* write sector erase command */
Table 7.39 Sector Erase
(LLD Function = lld_SectorEraseCmd)
Cycle Description Operation Byte Address Word Address Data
1 Unlock Write Base + AAAh Base + 555h 00AAh
2 Unlock Write Base + 554h Base + 2AAh 0055h
3 Setup Command Write Base + AAAh Base + 555h 0080h
4 Unlock Write Base + AAAh Base + 555h 00AAh
5 Unlock Write Base + 554h Base + 2AAh 0055h
6 Sector Erase Command Write Sector Address Sector Address 0030h
Unlimited additional sectors may be selected for erase; command(s) must be written within tSEA.
42 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Figure 7.5 Sector Erase Operation
Notes:
1. See Table 12.1 on page 84 for erase command sequence.
2. See the section on DQ3 for information on the sector erase timeout.
No
Write Unlock Cycles:
Address 555h, Data AAh
Address 2AAh, Data 55h
Write Sector Erase Cycles:
Address 555h, Data 80h
Address 555h, Data AAh
Address 2AAh, Data 55h
Sector Address, Data 30h
Write Additional
Sector Addresses
FAIL. Write reset command
to return to reading array.
PASS. Device returns
to reading array.
Perform Write Operation
Status Algorithm
Select
Additional
Sectors?
Unlock Cycle 1
Unlock Cycle 2
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Last Sector
Selected?
Done?
DQ5 = 1?
Command Cycle 1
Command Cycle 2
Command Cycle 3
Specify first sector for erasure
Error condition (Exceeded Timing Limits)
Status may be obtained by reading DQ7, DQ6 and/or DQ2.
Poll DQ3.
DQ3 = 1?
• Each additional cycle must be written within tSEA timeout
• Timeout resets after each additional cycle is written
• The host system may monitor DQ3 or wait tSEA to ensure
acceptance of erase commands
• No limit on number of sectors
• Commands other than Erase Suspend or selecting
additional sectors for erasure during timeout reset device
to reading array data
January 28, 2008 S29WS-P_00_A12 S29WS-P 43
Data Sheet
7.7.5 Chip Erase Command Sequence
Chip erase is a six-bus cycle operation as indicated by Table 12.1 on page 84. These commands invoke the
Embedded Erase algorithm, which does not require the system to preprogram prior to erase. The Embedded
Erase algorithm automatically preprograms and verifies the entire memory for an all zero data pattern prior to
electrical erase. After a successful chip erase, all locations of the chip contain FFFFh. The system is not
required to provide any controls or timings during these operations. Table 12.1 shows the address and data
requirements for the chip erase command sequence.
When the Embedded Erase algorithm is complete, that bank returns to the read mode and addresses are no
longer latched. The system can determine the status of the erase operation by using DQ7 or DQ6/DQ2. Refer
to Write Operation Status on page 47 for information on these status bits.
Any commands written during the chip erase operation are ignored. However, note that a hardware reset
immediately terminates the erase operation. If that occurs, the chip erase command sequence should be
reinitiated once that bank has returned to reading array data, to ensure data integrity.
Software Functions and Sample Code
The following is a C source code example of using the chip erase function. Refer to the Spansion Low Level
Driver User’s Guide (available on www.spansion.com) for general information on Spansion Flash memory
software development guidelines.
/* Example: Chip Erase Command */
/* Note: Cannot be suspended */
*( (UINT16 *)base_addr + 0x555 ) = 0x00AA; /* write unlock cycle 1 */
*( (UINT16 *)base_addr + 0x2AA ) = 0x0055; /* write unlock cycle 2 */
*( (UINT16 *)base_addr + 0x555 ) = 0x0080; /* write setup command */
*( (UINT16 *)base_addr + 0x555 ) = 0x00AA; /* write additional unlock cycle 1 */
*( (UINT16 *)base_addr + 0x2AA ) = 0x0055; /* write additional unlock cycle 2 */
*( (UINT16 *)base_addr + 0x000 ) = 0x0010; /* write chip erase command */
Table 7.40 Chip Erase
(LLD Function = lld_ChipEraseCmd)
Cycle Description Operation Byte Address Word Address Data
1 Unlock Write Base + AAAh Base + 555h 00AAh
2 Unlock Write Base + 554h Base + 2AAh 0055h
3 Setup Command Write Base + AAAh Base + 555h 0080h
4 Unlock Write Base + AAAh Base + 555h 00AAh
5 Unlock Write Base + 554h Base + 2AAh 0055h
6 Chip Erase Command Write Base + AAAh Base + 555h 0010h
44 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
7.7.6 Erase Suspend/Erase Resume Commands
The Erase Suspend command allows the system to interrupt a sector erase operation and then read data
from, or program data to, any sector not selected for erasure. The bank address is required when writing this
command. This command is valid only during the sector erase operation, after the minimum tSEA time-out
period during the sector erase command sequence. The Erase Suspend command is ignored if written during
the chip erase operation.
When the Erase Suspend command is written after the tSEA time-out period has expired and during the sector
erase operation, the device requires a minimum of tESL (erase suspend latency) to suspend the erase
operation. The status bits are undefined during the tESL period. To verify that the device is in the suspended
state, either:
wait until after tESL to check the status bits
perform a read and check that the status bits return array data
check whether any Autoselect commands are accepted
After the erase operation has been suspended, the bank enters the erase-suspend-read mode. The system
can read data from or program data to any sector not selected for erasure. (The device erase suspends all
sectors selected for erasure.) Reading at any address within erase-suspended sectors produces status
information on DQ7-DQ0. The system can use DQ7, or DQ6, and DQ2 together, to determine if a sector is
actively erasing or is erase-suspended. Refer to Table 7.47 on page 51 for information on these status bits.
After an erase-suspended program operation is complete, the bank returns to the erase-suspend-read mode.
The system can determine the status of the program operation using the DQ7 or DQ6 status bits, just as in
the standard program operation.
Note: While an erase operation can be suspended and resumed multiple times, a minimum delay of tERS
(Erase Resume to Suspend) is required from resume to the next suspend.
In the erase-suspend-read mode, the system can also issue the Autoselect command sequence. Refer to
Write Buffer Programming on page 36 and Autoselect on page 32 for details.
To resume the sector erase operation, the system must write the Erase Resume command. The bank
address of the erase-suspended bank is required when writing this command. Further writes of the Resume
command are ignored. Another Erase Suspend command can be written after the chip has resumed erasing.
Software Functions and Sample Code
The following is a C source code example of using the erase suspend function. Refer to the Spansion Low
Level Driver User’s Guide (available on www.spansion.com) for general information on Spansion Flash
memory software development guidelines.
/* Example: Erase suspend command */
*( (UINT16 *)bank_addr + 0x000 ) = 0x00B0; /* write suspend command */
The following is a C source code example of using the erase resume function. Refer to the Spansion Low
Level Driver User’s Guide (available on www.spansion.com) for general information on Spansion Flash
memory software development guidelines.
/* Example: Erase resume command */
*( (UINT16 *)bank_addr + 0x000 ) = 0x0030; /* write resume command */
/* The flash needs adequate time in the resume state */
Table 7.41 Erase Suspend
(LLD Function = lld_EraseSuspendCmd)
Cycle Operation Byte Address Word Address Data
1 Write Bank Address Bank Address 00B0h
Table 7.42 Erase Resume
(LLD Function = lld_EraseResumeCmd)
Cycle Operation Byte Address Word Address Data
1 Write Bank Address Bank Address 0030h
January 28, 2008 S29WS-P_00_A12 S29WS-P 45
Data Sheet
7.7.7 Accelerated Program/Erase
Accelerated single word programming, write buffer programming, sector erase, and chip erase operations are
enabled through the ACC function. This method is faster than the standard chip program and erase command
sequences.
The accelerated program and erase functions must not be used more than 10 times per sector. In
addition, accelerated program and erase should be performed at room temperature (25°C ±10°C).
If the system asserts VHH on this input, the device automatically enters the accelerated mode and uses the
higher voltage on the input to reduce the time required for program and erase operations. The system can
then use the Write Buffer Load command sequence provided by the Unlock Bypass mode. Note that if a
Write-to-Buffer-Abort Reset is required while in Unlock Bypass mode, the full 3-cycle RESET command
sequence must be used to reset the device. Removing VHH from the ACC input, upon completion of the
embedded program or erase operation, returns the device to normal operation.
Sectors must be unlocked prior to raising ACC to VHH.
The ACC pin must not be at VHH for operations other than accelerated programming accelerated erase, or
device damage may result.
The ACC pin must not be left floating or unconnected; inconsistent behavior of the device may result.
ACC locks all sector if set to VIL; ACC should be set to VIH for all other conditions.
7.7.8 Unlock Bypass
The unlock bypass feature allows the system to primarily program faster than using the standard program
command sequence, and it is not intended for use during erase. The unlock bypass command sequence is
initiated by first writing two unlock cycles. This is followed by a third write cycle containing the unlock bypass
command, 20h. The device then enters the unlock bypass mode. A two-cycle unlock bypass program
command sequence is all that is required to program in this mode. The first cycle in this sequence contains
the unlock bypass program command, A0h; the second cycle contains the program address and data.
Additional data is programmed in the same manner. This mode dispenses with the initial two unlock cycles
required in the standard program command sequence, resulting in faster total programming time. The erase
command sequences are four cycles in length instead of six cycles. Table 12.1 on page 84 shows the
requirements for the unlock bypass command sequences.
During the unlock bypass mode, only the Read, Unlock Bypass Program, and Unlock Bypass Reset
commands are valid. To exit the unlock bypass mode, the system must issue the two-cycle unlock bypass
reset command sequence. The first cycle must contain the bank address and the data 90h. The second cycle
need only contain the data 00h. The bank then returns to the read mode.
The device offers accelerated program operations through the ACC input. When the system asserts VHH on
this input, the device automatically enters the Unlock Bypass mode. The system may then write the two-cycle
Unlock Bypass program command sequence. The device uses the higher voltage on the ACC input to
accelerate the operation.
Refer to Erase/Program Timing on page 76 for parameters, and Figure 11.15 on page 77 and Figure 11.16
on page 77 for timing diagrams.
46 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Software Functions and Sample Code
The following are C source code examples of using the unlock bypass entry, program, and exit functions.
Refer to the Spansion Low Level Driver User’s Guide (available soon on www.spansion.com) for general
information on Spansion Flash memory software development guidelines.
/* Example: Unlock Bypass Entry Command */
*( (UINT16 *)bank_addr + 0x555 ) = 0x00AA; /* write unlock cycle 1 */
*( (UINT16 *)bank_addr + 0x2AA ) = 0x0055; /* write unlock cycle 2 */
*( (UINT16 *)bank_addr + 0x555 ) = 0x0020; /* write unlock bypass command */
/* At this point, programming only takes two write cycles. */
/* Once you enter Unlock Bypass Mode, do a series of like */
/* operations (programming or sector erase) and then exit */
/* Unlock Bypass Mode before beginning a different type of */
/* operations. */
/* Example: Unlock Bypass Program Command */
/* Do while in Unlock Bypass Entry Mode! */
*( (UINT16 *)bank_addr + 0x555 ) = 0x00A0; /* write program setup command */
*( (UINT16 *)pa ) = data; /* write data to be programmed */
/* Poll until done or error. */
/* If done and more to program, */
/* do above two cycles again. */
/* Example: Unlock Bypass Exit Command */
*( (UINT16 *)base_addr + 0x000 ) = 0x0090;
*( (UINT16 *)base_addr + 0x000 ) = 0x0000;
Table 7.43 Unlock Bypass Entry
(LLD Function = lld_UnlockBypassEntryCmd)
Cycle Description Operation Byte Address Word Address Data
1 Unlock Write Base + AAAh Base + 555h 00AAh
2 Unlock Write Base + 554h Base + 2AAh 0055h
3 Entry Command Write Base + AAAh Base + 555h 0020h
Table 7.44 Unlock Bypass Program
(LLD Function = lld_UnlockBypassProgramCmd)
Cycle Description Operation Byte Address Word Address Data
1 Program Setup Command Write Base + xxxh Base +xxxh 00A0h
2 Program Command Write Program Address Program Address Program Data
Table 7.45 Unlock Bypass Reset
(LLD Function = lld_UnlockBypassResetCmd)
Cycle Description Operation Byte Address Word Address Data
1 Reset Cycle 1 Write Base + xxxh Base +xxxh 0090h
2 Reset Cycle 2 Write Base + xxxh Base +xxxh 0000h
January 28, 2008 S29WS-P_00_A12 S29WS-P 47
Data Sheet
7.7.9 Write Operation Status
The device provides several bits to determine the status of a program or erase operation. The following
subsections describe the function of DQ1, DQ2, DQ3, DQ5, DQ6, and DQ7.
DQ7: Data# Polling
The Data# Polling bit, DQ7, indicates to the host system whether an Embedded Program or Erase algorithm
is in progress or completed, or whether a bank is in Erase Suspend. Data# Polling is valid after the rising
edge of the final WE# pulse in the command sequence. Note that the Data# Polling is valid only for the last
word being programmed in the write-buffer when write buffer programming is used. Reading Data# Polling
status on any word other than the last word to be programmed in the write-buffer-page returns false status
information. Similarly, attempting to program 1 over a 0 does not return valid Date# information.
During the Embedded Program algorithm, the device outputs on DQ7 the complement of the datum
programmed to DQ7. This DQ7 status also applies to programming during Erase Suspend. The system must
provide the program address to read valid status information on DQ7. If a program address falls within a
protected sector, Data# polling on DQ7 is active for approximately tPSP, then that bank returns to the read
mode.
During the Embedded Erase Algorithm, Data# polling produces a 0 on DQ7. When the Embedded Erase
algorithm is complete, or if the bank enters the Erase Suspend mode, Data# Polling produces a 1 on DQ7.
The system must provide an address within any of the sectors selected for erasure to read valid status
information on DQ7.
After an erase command sequence is written, if all sectors selected for erasing are protected, Data# Polling
on DQ7 is active for approximately tASP, then the bank returns to the read mode. If not all selected sectors are
protected, the Embedded Erase algorithm erases the unprotected sectors, and ignores the selected sectors
that are protected. However, if the system reads DQ7 at an address within a protected sector, the status may
not be valid.
Just prior to the completion of an Embedded Program or Erase operation, DQ7 may change asynchronously
with DQ6-DQ1 while Output Enable (OE#) is asserted low. That is, the device may change from providing
status information to valid data on DQ7. Even if the device has completed the program or erase operation and
DQ7 has valid data, the data outputs on DQ6-DQ1 may be still invalid. Valid data on DQ7-DQ1 appears on
successive read cycles.
See the following for more information: Table 7.47 on page 51, shows the outputs for Data# Polling on DQ7.
Figure 7.6 on page 48, shows the Data# Polling algorithm; and Figure 11.19 on page 79, shows the Data#
Polling timing diagram.
48 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Figure 7.6 Write Operation Status Flowchart
Notes:
1. DQ6 is toggling if Read2 DQ6 does not equal Read3 DQ6.
2. DQ2 is toggling if Read2 DQ2 does not equal Read3 DQ2.
3. May be due to an attempt to program a 0 to 1. Use the RESET command to exit operation.
4. Write buffer error if DQ1 of last read =1.
5. Invalid state, use RESET command to exit operation.
6. Valid data is the data that is intended to be programmed or all 1's for an erase operation.
7. Data polling algorithm valid for all operations except advanced sector protection.
START
Read 1
DQ7=valid
data?
YES
NO
Read 1
DQ5=1?
YES
NO
Write Buffer
Programming?
YES
NO
Device BUSY,
Re-Poll
Read3
DQ1=1?
YES
NO
Read 2
Read 3
Read 2
Read 3
Read 2
Read 3
Read3
DQ1=1
AND DQ7
Valid Data?
YES
NO
(Note 4)
Write Buffer
Operation
Failed
DQ6
toggling?
YES
NO
TIMEOUT
(Note 1) (Note 3)
Programming
Operation?
DQ6
toggling?
YES
NO
YES
NO
DQ2
toggling?
YES
NO
Erase
Operation
Complete
Device in
Erase/Suspend
Mode
Program
Operation
Failed
DEVICE
ERROR
Erase
Operation
Complete
Read3=
valid data?
YES
NO
Device BUSY,
Re-Poll
Device BUSY,
Re-Poll
Device BUSY,
Re-Poll
(Note 1)
(Note 2)
(Note 6)
(Note 5)
January 28, 2008 S29WS-P_00_A12 S29WS-P 49
Data Sheet
DQ6: Toggle Bit I
Toggle Bit I on DQ6 indicates whether an Embedded Program or Erase algorithm is in progress or complete,
or whether the device has entered the Erase Suspend mode. Toggle Bit I may be read at any address in the
same bank, and is valid after the rising edge of the final WE# pulse in the command sequence (prior to the
program or erase operation), and during the sector erase time-out.
During an Embedded Program or Erase algorithm operation, successive read cycles to any address cause
DQ6 to toggle. When the operation is complete, DQ6 stops toggling.
After an erase command sequence is written, if all sectors selected for erasing are protected, DQ6 toggles for
approximately tASP [all sectors protected toggle time], then returns to reading array data. If not all selected
sectors are protected, the Embedded Erase algorithm erases the unprotected sectors, and ignores the
selected sectors that are protected.
The system can use DQ6 and DQ2 together to determine whether a sector is actively erasing or is erase-
suspended. When the device is actively erasing (that is, the Embedded Erase algorithm is in progress), DQ6
toggles. When the device enters the Erase Suspend mode, DQ6 stops toggling. However, the system must
also use DQ2 to determine which sectors are erasing or erase-suspended. Alternatively, the system can use
DQ7 (see the subsection on DQ7: Data# Polling).
If a program address falls within a protected sector, DQ6 toggles for approximately tPA P after the program
command sequence is written, then returns to reading array data.
DQ6 also toggles during the erase-suspend-program mode, and stops toggling once the Embedded Program
Algorithm is complete.
See the following for additional information: Figure 7.6 on page 48, Figure 11.20 on page 79, and Table 7.46
on page 49 and Table 7.47 on page 51.
Toggle Bit I on DQ6 requires Read address to be relatched by toggling AVD# for each reading cycle.
DQ2: Toggle Bit II
The Toggle Bit II on DQ2, when used with DQ6, indicates whether a particular sector is actively erasing (that
is, the Embedded Erase algorithm is in progress), or whether that sector is erase-suspended. Toggle Bit II is
valid after the rising edge of the final WE# pulse in the command sequence. DQ2 toggles when the system
reads at addresses within those sectors that have been selected for erasure. But DQ2 cannot distinguish
whether the sector is actively erasing or is erase-suspended. DQ6, by comparison, indicates whether the
device is actively erasing, or is in Erase Suspend, but cannot distinguish which sectors are selected for
erasure. Thus, both status bits are required for sector and mode information. Refer to Table 7.46 to compare
outputs for DQ2 and DQ6. See the following for additional information: Figure 7.6 on page 48, DQ6: Toggle
Bit I on page 49, and Figures 11.1911.22.
Read address has to be relatched by toggling AVD# for each reading cycle.
Table 7.46 DQ6 and DQ2 Indications
If device is and the system reads then DQ6 and DQ2
programming, at any address at the bank being
programmed toggles, does not toggle.
actively erasing,
at an address within a sector selected
for erasure, toggles, also toggles.
at an address within sectors not
selected for erasure, toggles, does not toggle.
erase suspended,
at an address within a sector selected
for erasure, does not toggle, toggles.
at an address within sectors not
selected for erasure, returns array data, returns array data. The system can read
from any sector not selected for erasure.
programming in erase
suspend
at any address at the bank being
programmed toggles, is not applicable.
50 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Reading Toggle Bits DQ6/DQ2
Whenever the system initially begins reading toggle bit status, it must read DQ7–DQ0 at least twice in a row
to determine whether a toggle bit is toggling. Typically, the system would note and store the value of the
toggle bit after the first read. After the second read, the system would compare the new value of the toggle bit
with the first. If the toggle bit is not toggling, the device has completed the program or erases operation. The
system can read array data on DQ7–DQ0 on the following read cycle. However, if after the initial two read
cycles, the system determines that the toggle bit is still toggling, the system also should note whether the
value of DQ5 is high (see the section on DQ5). If it is, the system should then determine again whether the
toggle bit is toggling, since the toggle bit may have stopped toggling just as DQ5 went high. If the toggle bit is
no longer toggling, the device has successfully completed the program or erases operation. If it is still
toggling, the device did not complete the operation successfully, and the system must write the reset
command to return to reading array data. The remaining scenario is that the system initially determines that
the toggle bit is toggling and DQ5 has not gone high. The system may continue to monitor the toggle bit and
DQ5 through successive read cycles, determining the status as described in the previous paragraph.
Alternatively, it may choose to perform other system tasks. In this case, the system must start at the
beginning of the algorithm when it returns to determine the status of the operation. Refer to Figure 7.6
on page 48 for more details.
Note: When verifying the status of a write operation (embedded program/erase) of a memory bank, DQ6 and
DQ2 toggle between high and low states in a series of consecutive and contiguous status read cycles. In
order for this toggling behavior to be properly observed, the consecutive status bit reads must not be
interleaved with read accesses to other memory banks. If it is not possible to temporarily prevent reads to
other memory banks, then it is recommended to use the DQ7 status bit as the alternative method of
determining the active or inactive status of the write operation.
DQ5: Exceeded Timing Limits
DQ5 indicates whether the program or erase time has exceeded a specified internal pulse count limit. Under
these conditions DQ5 produces a 1, indicating that the program or erase cycle was not successfully
completed. The device does not output a 1 on DQ5 if the system tries to program a 1 to a location that was
previously programmed to 0. Only an erase operation can change a 0 back to a 1. Under this condition, the
device ignores the bit that was incorrectly instructed to be programmed from a 0 to a 1, while any other bits
that were correctly requested to be changed from 1 to 0 are programmed. Attempting to program a 0 to a 1 is
masked during the programming operation. Under valid DQ5 conditions, the system must write the reset
command to return to the read mode (or to the erase-suspend-read mode if a bank was previously in the
erase-suspend-program mode).
DQ3: Sector Erase Timeout State Indicator
After writing a sector erase command sequence, the system may read DQ3 to determine whether or not
erasure has begun. (The sector erase timer does not apply to the chip erase command.) If additional sectors
are selected for erasure, the entire time-out also applies after each additional sector erase command. When
the time-out period is complete, DQ3 switches from a 0 to a 1. If the time between additional sector erase
commands from the system can be assumed to be less than tSEA, the system need not monitor DQ3. See
Sector Erase Command Sequence for more details.
After the sector erase command is written, the system should read the status of DQ7 (Data# Polling) or DQ6
(Toggle Bit I) to ensure that the device has accepted the command sequence, and then read DQ3. If DQ3 is
1, the Embedded Erase algorithm has begun; all further commands (except Erase Suspend) are ignored until
the erase operation is complete. If DQ3 is 0, the device accepts additional sector erase commands. To
ensure the command has been accepted, the system software should check the status of DQ3 prior to and
following each sub-sequent sector erase command. If DQ3 is high on the second status check, the last
command might not have been accepted. Table 7.47 on page 51 shows the status of DQ3 relative to the
other status bits.
DQ1: Write to Buffer Abort
DQ1 indicates whether a Write to Buffer operation was aborted. Under these conditions DQ1 produces a 1.
The system must issue the Write to Buffer Abort Reset command sequence to return the device to reading
array data. See Write Buffer Programming Operation for more details.
January 28, 2008 S29WS-P_00_A12 S29WS-P 51
Data Sheet
Notes:
1. DQ5 switches to ‘1’ when an Embedded Program or Embedded Erase operation has exceeded the maximum timing limits. Refer to the
section on DQ5 for more information.
2. DQ7 and DQ2 require a valid address when reading status information. Refer to the appropriate subsection for further details.
3. Data are invalid for addresses in a Program Suspended sector.
4. DQ1 indicates the Write to Buffer ABORT status during Write Buffer Programming operations.
5. The data-bar polling algorithm should be used for Write Buffer Programming operations. Note that DQ7# during Write Buffer
Programming indicates the data-bar for DQ7 data for the LAST LOADED WRITE-BUFFER ADDRESS location.
7.8 Simultaneous Read/Program or Erase
The simultaneous read/program or erase feature allows the host system to read data from one bank of
memory while programming or erasing another bank of memory. An erase operation may also be suspended
to read from or program another location within the same bank (except the sector being erased). Figure 11.25
on page 82 shows how read and write cycles may be initiated for simultaneous operation with zero latency.
Refer to DC Characteristics on page 67 for read-while-program and read-while-erase current specification.
7.9 Writing Commands/Command Sequences
When the device is configured for Asynchronous read, only Asynchronous write operations are allowed, and
CLK is ignored. When in the Synchronous read mode configuration, the device is able to perform both
Asynchronous and Synchronous write operations. CLK and AVD# induced address latches are supported in
the Synchronous programming mode. During a synchronous write operation, to write a command or
command sequence (which includes programming data to the device and erasing sectors of memory), the
system must drive AVD# and CE# to VIL, and OE# to VIH when providing an address to the device, and drive
WE# and CE# to VIL, and OE# to VIH when writing commands or data. During an asynchronous write
operation, the system must drive CE# and WE# to VIL and OE# to VIH when providing an address, command,
and data. Addresses are latched on the last falling edge of WE# or CE#, while data is latched on the 1st rising
edge of WE# or CE#. An erase operation can erase one sector, multiple sectors, or the entire device.
Table 6.2 on page 17 and Table 6.3 on page 18 indicate the address space that each sector occupies. The
device address space is divided into sixteen banks: Banks 1 through 14 contain only 64 Kword sectors, while
Banks 0 and 15 contain both 16 Kword boot sectors in addition to 64 Kword sectors. A bank address is the set
of address bits required to uniquely select a bank. Similarly, a sector address is the address bits required to
uniquely select a sector. ICC2 in DC Characteristics on page 67 represents the active current specification for
the write mode. AC Characteristics-Synchronous and AC Characteristics-Asynchronous contain timing
specification tables and timing diagrams for write operations.
Table 7.47 Write Operation Status
Status
DQ7
(Note 2) DQ6
DQ5
(Note 1) DQ3
DQ2
(Note 2)
DQ1
(Note 4)
Standard
Mode
Embedded Program Algorithm DQ7# Toggle 0 N/A No toggle 0
Embedded Erase Algorithm 0 Toggle 0 1 Toggle N/A
Program
Suspend
Mode
(Note 3)
Reading within Program Suspended Sector
INVALID
(Not
Allowed)
INVALID
(Not
Allowed)
INVALID
(Not
Allowed)
INVALID
(Not
Allowed)
INVALID
(Not
Allowed)
INVALID
(Not
Allowed)
Reading within Non-Program Suspended
Sector Data Data Data Data Data Data
Erase
Suspend
Mode
Erase-Suspend-
Read
Erase
Suspended Sector 1 No toggle 0 N/A Toggle N/A
Non-Erase Suspended
Sector Data Data Data Data Data Data
Erase-Suspend-Program DQ7# Toggle 0 N/A N/A N/A
Write to
Buffer
(Note 5)
BUSY State DQ7# Toggle 0 N/A N/A 0
Exceeded Timing Limits DQ7# Toggle 1 N/A N/A 0
ABORT State DQ7# Toggle 0 N/A N/A 1
52 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
7.10 Handshaking
The handshaking feature allows the host system to detect when data is ready to be read by simply monitoring
the RDY pin which is a dedicated output and is controlled by CE#.
7.11 Hardware Reset
The RESET# input provides a hardware method of resetting the device to reading array data. When RESET#
is driven low for at least a period of tRP, the device immediately terminates any operation in progress, tristates
all outputs, resets the configuration register, and ignores all read/write commands for the duration of the
RESET# pulse. The device also resets the internal state machine to reading array data.
To ensure data integrity the operation that was interrupted should be reinitiated once the device is ready to
accept another command sequence.
When RESET# is held at VSS, the device draws CMOS standby current (ICC4). If RESET# is held at VIL, but
not at VSS, the standby current is greater.
RESET# may be tied to the system reset circuitry which enables the system to read the boot-up firmware
from the Flash memory upon a system reset.
See Figure 11.5 on page 69 and Figure 11.14 on page 75 for timing diagrams.
7.12 Software Reset
Software reset is part of the command set (see Table 12.1 on page 84) that also returns the device to array
read mode and must be used for the following conditions:
to exit Autoselect mode
when DQ5 goes high during write status operation that indicates program or erase cycle was not
successfully completed
exit sector lock/unlock operation.
to return to erase-suspend-read mode if the device was previously in Erase Suspend mode.
after any aborted operations
Exiting Read Configuration Registration Mode
Software Functions and Sample Code
Note:
Base = Base Address.
The following is a C source code example of using the reset function. Refer to the Spansion Low Level Driver
User’s Guide (available on www.spansion.com) for general information on Spansion Flash memory software
development guidelines.
/* Example: Reset (software reset of Flash state machine) */
*( (UINT16 *)base_addr + 0x000 ) = 0x00F0;
The following are additional points to consider when using the reset command:
This command resets the banks to the read and address bits are ignored.
Reset commands are ignored once erasure has begun until the operation is complete.
Once programming begins, the device ignores reset commands until the operation is complete
The reset command may be written between the cycles in a program command sequence before
programming begins (prior to the third cycle). This resets the bank to which the system was writing to the
read mode.
Table 7.48 Reset (LLD Function = lld_ResetCmd)
Cycle Operation Byte Address Word Address Data
Reset Command Write Base + xxxh Base + xxxh 00F0h
January 28, 2008 S29WS-P_00_A12 S29WS-P 53
Data Sheet
If the program command sequence is written to a bank that is in the Erase Suspend mode, writing the reset
command returns that bank to the erase-suspend-read mode.
The reset command may be also written during an Autoselect command sequence.
If a bank has entered the Autoselect mode while in the Erase Suspend mode, writing the reset command
returns that bank to the erase-suspend-read mode.
If DQ1 goes high during a Write Buffer Programming operation, the system must write the “Write to Buffer
Abort Reset” command sequence to RESET the device to reading array data. The standard RESET
command does not work during this condition.
To exit the unlock bypass mode, the system must issue a two-cycle unlock bypass reset command
sequence [see command table for details].
54 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
8. Advanced Sector Protection/Unprotection
The Advanced Sector Protection/Unprotection feature disables or enables programming or erase operations
in any or all sectors and can be implemented through software and/or hardware methods, which are
independent of each other. This section describes the various methods of protecting data stored in the
memory array. An overview of these methods in shown in Figure 8.1 on page 54.
Figure 8.1 Advanced Sector Protection/Unprotection
Hardware Methods Software Methods
ACC = V
IL
(
All sectors locked)
WP# = V
IL
(All boot
sectors locked)
Password Method
(DQ2)
Persistent Method
(DQ1)
Lock Register
(One Time Programmable)
PPB Lock Bit1,2,3
64-bit Password
(One Time Protect)
1 = PPBs Unlocked
0 = PPBs Locked
Memory Array
Sector 0
Sector 1
Sector 2
Sector N-2
Sector N-1
Sector N4
PPB 0
PPB 1
PPB 2
PPB N-2
PPB N-1
PPB N
Persistent
Protection Bit
(PPB)
5, 6
DYB 0
DYB 1
DYB 2
DYB N-2
DYB N-1
DYB N
Dynamic
Protection Bit
(DYB)
7, 8, 9
7. 0 = Sector Protected,
1 = Sector Unprotected.
8. DYB bits are only effective for
sectors that not protected via PPB
locking mechanism.
9. Volatile Bits: defaults to unprotected
after power up.
5. 0 = Sector Protected,
1 = Sector Unprotected.
6. PPBs programmed individually,
but cleared collectively
1. Bit is volatile, and defaults to “1” on
reset.
2. Programming to “0” locks all PPBs to
their current state.
3. Once programmed to “0”, requires
hardware reset to unlock.
4. N = Highest Address Sector.
January 28, 2008 S29WS-P_00_A12 S29WS-P 55
Data Sheet
8.1 Advanced Sector Protection Software Examples
Table 8.1 contains all possible combinations of the DYB, PPB, and PPB Lock Bit relating to the status of the
sector.
8.2 Lock Register
The Lock Register consists of 4 bits. The Secured Silicon Sector Protection Bit is DQ0, Persistent Protection
Mode Lock Bit is DQ1, Password Protection Mode Lock Bit is DQ2, Persistent Sector Protection OTP bit is
DQ3. If DQ0 is ‘0’, it means that the Customer Secured Silicon area is locked and if DQ0 is ‘1’, it means that it
is unlocked. When DQ2 is set to ‘1’ and DQ1 is set to ‘0’, the device can only be used in the Persistent
Protection Mode. When the device is set to Password Protection Mode, DQ1 is required to be set to ‘1’ and
DQ2 is required to be set to ‘0’. DQ3 is programmed in the Spansion factory. When the device is programmed
to disable all PPB erase command, DQ3 outputs a ‘0’, when the lock register bits are read. Similarly, if the
device is programmed to enable all PPB erase command, DQ3 outputs a ‘1’ when the lock register bits are
read. Likewise the DQ4 bit is also programmed in the Spansion Factory. DQ4 is the bit which indicates
whether Volatile Sector Protection Bit (DYB) is protected or not after boot-up. When the device is
programmed to set all Volatile Sector Protection Bit protected after power-up, DQ4 outputs a ‘0’ when the lock
register bits are read. Similarly, when the device is programmed to set all Volatile Sector Protection Bit un-
protected after power-up, DQ4 outputs a ‘1’. Each of these bits in the lock register are non-volatile. DQ15-
DQ5 are reserved and will be 1’s.
For programming lock register bits refer to Table 12.2 on page 86.
Notes:
1. If the password mode is chosen, the password must be programmed and verified before setting the corresponding lock register bit (DQ2).
Failing to program and verifying the password prior to setting lock register (DQ2), causes all sectors to lock out.
2. It is recommended a sector protection method to be chosen by programming DQ1 or DQ2 prior to shipment.
3. After the Lock Register Bits Command Set Entry sequence is written, reads and writes for Bank 0 are disabled, while reads from other
banks are allowed until exiting this mode. Simultaneous operation is only valid as long as lock register program command is not executed.
4. If both lock bits are selected to be programmed (to zeros) at the same time, the operation aborts.
5. Once the Password Mode Lock Bit is programmed, the Persistent Mode Lock Bit is permanently disabled, and no changes to the
protection scheme are allowed. Similarly, if the Persistent Mode Lock Bit is programmed, the Password Mode is permanently disabled.
6. During erase/program suspend, ASP entry commands are not allowed.
7. Data Polling can be done immediately after the lock register programming command sequence (no delay required). Note that status
polling can be done only in bank 0
8. Reads from other banks (simultaneous operation) are not allowed during lock register programming. This restriction applies to both
synchronous and asynchronous read operations.
Table 8.1 Sector Protection Schemes
Unique Device PPB Lock Bit
0 = locked
1 = unlocked
Sector PPB
0 = protected
1 = unprotected
Sector DYB
0 = protected
1 = unprotected Sector Protection Status
Any Sector 0 0 x Protected through PPB
Any Sector 0 0 x Protected through PPB
Any Sector 0 1 1 Unprotected
Any Sector 0 1 0 Protected through DYB
Any Sector 1 0 x Protected through PPB
Any Sector 1 0 x Protected through PPB
Any Sector 1 1 0 Protected through DYB
Any Sector 1 1 1 Unprotected
Table 8.2 Lock Register
DQ15-5 DQ4 DQ3 DQ2 DQ1 DQ0
1’s Reserved (default = 1)
PPB One Time Programmable Bit
0 = All PPB Erase Command
disabled
1 = All PPB Erase Command
enabled
Password
Protection
Mode Lock Bit
Persistent
Protection
Mode Lock Bit
Secured
Silicon Sector
Protection Bit
56 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
After selecting a sector protection method, each sector can operate in any of the following three states:
1. Constantly locked. The selected sectors are protected and can not be reprogrammed unless PPB
lock bit is cleared via a password, hardware reset, or power cycle.
2. Dynamically locked. The selected sectors are protected and can be altered via software
commands.
3. Unlocked. The sectors are unprotected and can be erased and/or programmed.
These states are controlled by the bit types described in Sections 8.38.6.
8.3 Persistent Protection Bits
The Persistent Protection Bits are unique and nonvolatile for each sector and have the same endurances as
the Flash memory. Preprogramming and verification prior to erasure are handled by the device, and therefore
do not require system monitoring.
Notes:
1. Each PPB is individually programmed and all are erased in parallel.
2. While programming PPB for a sector, array data can not be read from any other banks.
3. Entry command disables reads and writes for the bank selected.
4. Reads within that bank return the PPB status for that sector.
5. Reads from other banks are allowed while program/erase is not allowed.
6. All Reads must be performed using the Asynchronous mode.
7. The specific sector address (Amax-A14) are written at the same time as the program command.
8. If the PPB Lock Bit is set, the PPB Program or erase command does not execute and times-out
without programming or erasing the PPB.
9. There are no means for individually erasing a specific PPB and no specific sector address is
required for this operation.
10. The PPB Exit command must be issued after the execution which resets the device to read mode
and re-enables reads and writes for Bank 0
11. The programming state of the PPB for a given sector can be verified by writing a PPB Status Read
Command to the device as described by the flow chart shown in Figure 8.2 on page 57.
12. During PPB program / erase data polling can be done synchronously.
13. If the user attempts to program or erase a protected sector, the device ignores the command and
returns to read mode.
January 28, 2008 S29WS-P_00_A12 S29WS-P 57
Data Sheet
Figure 8.2 PPB Program/Erase Algorithm
Read Byte Twice
Addr = SA0
Enter PPB
Command Set.
Addr = BA
Program PPB Bit.
Addr = SA0
DQ5 = 1?
Yes
Yes
Yes
No
No
No
Yes
DQ6 =
Toggle?
DQ6 =
Toggle?
Read Byte.
Addr = SA
PASS
FAIL
End
Exit PPB
Command Set
DQ0 =
'1' (Erase)
'0' (Pgm.)?
Read Byte Twice
Addr = SA0
No
Wait 500 µs
58 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
8.4 Dynamic Protection Bits
Dynamic Protection Bits are volatile and unique for each sector and can be individually modified. DYBs only
control the protection scheme for unprotected sectors that have their PPBs cleared (erased to 1). By issuing
the DYB Set or Clear command sequences, the DYBs are set (programmed to 0) or cleared (erased to 1),
thus placing each sector in the protected or unprotected state respectively. This feature allows software to
easily protect sectors against inadvertent changes yet does not prevent the easy removal of protection when
changes are needed.
Notes
1. The DYBs can be set (programmed to 0) or cleared (erased to 1) as often as needed.
When the parts are first shipped, the PPBs are cleared (erased to 1).
2. The default state of DYB is unprotected after power up and all sectors can be modified depending
on the status of PPB bit for that sector, (erased to 1). Then the sectors can be modified depending
upon the PPB state of that sector (see Table 8.1 on page 55).
3. It is possible to have sectors that are persistently locked with sectors that are left in the dynamic
state.
4. The DYB Set or Clear commands for the dynamic sectors signify protected or unprotected state of
the sectors respectively. However, if there is a need to change the status of the persistently locked
sectors, a few more steps are required. First, the PPB Lock Bit must be cleared by either putting
the device through a power-cycle, or hardware reset. The PPBs can then be changed to reflect the
desired settings. Setting the PPB Lock Bit once again locks the PPBs, and the device operates
normally again.
5. Data polling is not available for DYB program / erase.
6. DYB read data can be done synchronously.
7. If the user attempts to program or erase a protected sector, the device ignores the command and
returns to read mode.
8.5 Persistent Protection Bit Lock Bit
The Persistent Protection Bit Lock Bit is a global volatile bit for all sectors. When set (programmed to 0), it
locks all PPBs and when cleared (programmed to 1), allows the PPBs to be changed. There is only one PPB
Lock Bit per device.
Notes
1. No software command sequence unlocks this bit unless the device is in the password protection
mode; only a hardware reset or a power-up clears this bit.
2. The PPB Lock Bit must be set (programmed to 0) only after all PPBs are configured to the desired
settings.
January 28, 2008 S29WS-P_00_A12 S29WS-P 59
Data Sheet
8.6 Password Protection Method
The Password Protection Method allows an even higher level of security than the Persistent Sector Protection
Mode by requiring a 64 bit password for unlocking the device PPB Lock Bit. In addition to this password
requirement, after power up and reset, the PPB Lock Bit is set 0 to maintain the password mode of operation.
Successful execution of the Password Unlock command by entering the entire password clears the PPB Lock
Bit, allowing for sector PPBs modifications.
Notes
1. If the password mode is chosen, the password must be programmed and verified before setting the
corresponding lock register bit (DQ2). Failing to program and verifying the password prior to setting
lock register (DQ2), causes all sectors to lock out.
2. There is no special addressing order required for programming the password. Once the Password
is written and verified, the Password Mode Locking Bit must be set in order to prevent access.
3. The Password Program Command is only capable of programming 0s. Programming a 1 after a
cell is programmed as a 0 results in a time-out with the cell as a 0.
4. The password is all 1s when shipped from the factory.
5. All 64-bit password combinations are valid as a password.
6. There is no means to verify what the password is after it is set.
7. The Password Mode Lock Bit, once set, prevents reading the 64-bit password on the data bus and
further password programming.
8. The Password Mode Lock Bit is not erasable.
9. The lower two address bits (A1–A0) are valid during the Password Read, Password Program, and
Password Unlock.
10. The exact password must be entered in order for the unlocking function to occur.
11. The Password Unlock command cannot be issued any faster than 1 µs at a time to prevent a
hacker from running through all the 64-bit combinations in an attempt to correctly match a
password.
12. Approximately 1 µs is required for unlocking the device after the valid 64-bit password is given to
the device.
13. Password verification is only allowed during the password programming operation.
14. All further commands to the password region are disabled and all operations are ignored.
15. If the password is lost after setting the Password Mode Lock Bit, there is no way to clear the PPB
Lock Bit.
16. Entry command sequence must be issued prior to any of any operation and it disables reads and
writes for Bank 0. Reads and writes for other banks excluding Bank 0 are allowed.
17. If the user attempts to program or erase a protected sector, the device ignores the command and
returns to read mode.
18. A program or erase command to a protected sector enables status polling and returns to read
mode without having modified the contents of the protected sector.
19. The programming of the DYB, PPB, and PPB Lock for a given sector can be verified by writing
individual status read commands DYB Status, PPB Status, and PPB Lock Status to the device.
60 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Figure 8.3 Lock Register Program Algorithm
8.7 Hardware Data Protection Methods
The device offers two main types of data protection at the sector level via hardware control:
When WP# is at VIL, the four outermost sectors (including Secured Silicon Area) are locked.
When ACC is at VIL, all sectors (including Secured Silicon Area) are locked.
There are additional methods by which intended or accidental erasure of any sectors can be prevented via
hardware means. The following subsections describes these methods:
Write Unlock Cycles:
Address 555h, Data AAh
Address 2AAh, Data 55h
Write
Enter Lock Register Command:
Address 555h, Data 40h
Program Lock Register Data
Address XXXh, Data A0h
Address 77h*, Data PD
Unlock Cycle 1
Unlock Cycle 2
XXXh = Address don’t care
* Not on future devices
Program Data (PD): See text for Lock Register
definitions
Caution: Lock register can only be progammed
once.
PASS. Write Lock Register
Exit Command:
Address XXXh, Data 90h
Address XXXh, Data 00h
Device returns to reading array.
Perform Polling Algorithm
(see Write Operation Status
flowchart)
Yes
Yes
No
No
Done?
DQ5 = 1? Error condition (Exceeded Timing Limits)
FAIL. Write rest command
to return to reading array.
January 28, 2008 S29WS-P_00_A12 S29WS-P 61
Data Sheet
8.7.1 WP# Method
The Write Protect feature provides a hardware method of protecting the four outermost sectors. This function
is provided by the WP# pin and overrides the previously discussed Sector Protection/Unprotection method.
If the system asserts VIL on the WP# pin, the device disables program and erase functions in the outermost
boot sectors, as well as Secured Silicon Area. The outermost boot sectors are the sectors containing both the
lower and upper set of sectors in a dual-boot-configured device.
If the system asserts VIH on the WP# pin, the device reverts to whether the boot sectors were last set to be
protected or unprotected. That is, sector protection or unprotection for these sectors depends on whether
they were last protected or unprotected.
Note that the WP# pin must not be left floating or unconnected as inconsistent behavior of the device may
result.
The WP# pin must be held stable during a command sequence execution
8.7.2 ACC Method
This method is similar to above, except it protects all sectors. Once ACC input is set to VIL, all program and
erase functions are disabled and hence all sectors (including the Secured Silicon Area) are protected.
8.7.3 Low VCC Write Inhibit
When VCC is less than VLKO, the device does not accept any write cycles. This protects data during VCC
power-up and power-down.
The command register and all internal program/erase circuits are disabled, and the device resets to reading
array data. Subsequent writes are ignored until VCC is greater than VLKO. The system must provide the
proper signals to the control inputs to prevent unintentional writes when VCC is greater than VLKO.
Table 8.3 S29WS512P Sector Protection
Dual Boot Configuration
Bank 0 SA000-SA003 WP# Protected
Bank 1-7 No Sector WP# Protection
Bank 8-14 No Sector WP# Protection
Bank 15 SA514-SA517 WP# Protected
Table 8.4 S29WS256P Sector Protection
Dual Boot Configuration
Bank 0 SA000-SA003 WP# Protected
Bank 1-7 No Sector WP# Protection
Bank 8-14 No Sector WP# Protection
Bank 15 SA258-SA261 WP# Protected
Table 8.5 S29WS128P Sector Protection
Dual Boot Configuration
Bank 0 SA000-SA003 WP# Protected
Bank 1-7 No Sector WP# Protection
Bank 8-14 No Sector WP# Protection
Bank 15 SA130-SA133 WP# Protected
62 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
8.7.4 Write Pulse Glitch Protection
Noise pulses of less than 3 ns (typical) on OE#, CE# or WE# do not initiate a write cycle.
8.7.5 Power-Up Write Inhibit
If WE# = CE# = RESET# = VIL and OE# = VIH during power up, the device does not accept commands on the
rising edge of WE#. The internal state machine is automatically reset to the read mode on power-up.
9. Power Conservation Modes
9.1 Standby Mode
When the system is not reading or writing to the device, it can place the device in the standby mode. In this
mode, current consumption is greatly reduced, and the outputs are placed in the high impedance state,
independent of the OE# input. The device enters the CMOS standby mode when the CE# and RESET#
inputs are both held at VCC ± 0.2 V. The device requires standard access time (tCE) for read access, before it
is ready to read data. If the device is deselected during erasure or programming, the device draws active
current until the operation is completed. ICC3 in DC Characteristics on page 67 represents the standby
current specification
9.2 Automatic Sleep Mode
The automatic sleep mode minimizes Flash device energy consumption only while in asynchronous main
array read mode. the device automatically enables this mode when addresses remain stable for tACC + 20 ns.
The automatic sleep mode is independent of the CE#, WE#, and OE# control signals. Standard address
access timings provide new data when addresses are changed. While in sleep mode, output data is latched
and always available to the system. While in synchronous mode, the automatic sleep mode is disabled. Note
that a new burst operation is required to provide new data. ICC6 in DC Characteristics on page 67 represents
the automatic sleep mode current specification.
9.3 Hardware RESET# Input Operation
The RESET# input provides a hardware method of resetting the device to reading array data. When RESET#
is driven low for at least a period of tRP, the device immediately terminates any operation in progress, tristates
all outputs, resets the configuration register, and ignores all read/write commands for the duration of the
RESET# pulse. The device also resets the internal state machine to reading array data. The operation that
was interrupted should be reinitiated once the device is ready to accept another command sequence to
ensure data integrity.
When RESET# is held at VSS ± 0.2 V, the device draws CMOS standby current (ICC4). If RESET# is held at
VIL but not within VSS ± 0.2 V, the standby current is greater.
RESET# may be tied to the system reset circuitry and thus, a system reset would also reset the Flash
memory, enabling the system to read the boot-up firmware from the Flash memory.
9.4 Output Disable (OE#)
When the OE# input is at VIH, output from the device is disabled. The outputs are placed in the high
impedance state.
January 28, 2008 S29WS-P_00_A12 S29WS-P 63
Data Sheet
10. Secured Silicon Sector Flash Memory Region
The Secured Silicon Sector provides an extra Flash memory region that enables permanent part identification
through an Electronic Serial Number (ESN). The Secured Silicon Sector is 256 words in length that consists
of 128 words for factory data and 128 words for customer-secured areas. All Secured Silicon reads outside of
the 256-word address range returns invalid data. The Factory Indicator Bit, DQ7, (at Autoselect address 03h)
is used to indicate whether or not the Factory Secured Silicon Sector is locked when shipped from the factory.
The Customer Indicator Bit (DQ6) is used to indicate whether or not the Customer Secured Silicon Sector is
locked when shipped from the factory.
Please note the following general conditions:
While Secured Silicon Sector access is enabled, simultaneous operations are allowed except for Bank 0.
On power-up, or following a hardware reset, the device reverts to sending commands to the normal
address space.
Reads can be performed in the Asynchronous or Synchronous mode.
Burst mode reads within Secured Silicon Sector wrap from address FFh back to address 00h.
Reads outside of sector 0 return memory array data.
Continuous burst read past the maximum address is undefined.
Sector 0 is remapped from memory array to Secured Silicon Sector array.
Once the Secured Silicon Sector Entry Command is issued, the Secured Silicon Sector Exit command
must be issued to exit Secured Silicon Sector Mode.
The Secured Silicon Sector is not accessible when the device is executing an Embedded Program or
Embedded Erase algorithm.
10.1 Factory Secured Silicon Sector
The Factory Secured Silicon Sector is always protected when shipped from the factory and has the Factory
Indicator Bit (DQ7) permanently set to a 1. This prevents cloning of a factory locked part and ensures the
security of the ESN and customer code once the product is shipped to the field.
These devices are available pre programmed with one of the following:
A random, 8 Word secure ESN only within the Factory Secured Silicon Sector
Customer code within the Customer Secured Silicon Sector through the Spansion® programming service.
Both a random, secure ESN and customer code through the Spansion programming service.
Customers may opt to have their code programmed through the Spansion programming services. Spansion
programs the customer's code, with or without the random ESN. The devices are then shipped from the
Spansion factory with the Factory Secured Silicon Sector and Customer Secured Silicon Sector permanently
locked. Contact your local representative for details on using Spansion programming services.
Table 10.1 Secured Silicon Sector Addresses
Sector Sector Size Address Range
Customer 128 words 000080h-0000FFh
Factory 128 words 000000h-00007Fh
64 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
10.2 Customer Secured Silicon Sector
The Customer Secured Silicon Sector is typically shipped unprotected (DQ6 set to 0), allowing customers to
utilize that sector in any manner they choose. If the security feature is not required, the Customer Secured
Silicon Sector can be treated as an additional Flash memory space.
Please note the following:
Once the Customer Secured Silicon Sector area is protected, the Customer Indicator Bit is permanently
set to 1.
The Customer Secured Silicon Sector can be read any number of times, but can be programmed and
locked only once. The Customer Secured Silicon Sector lock must be used with caution as once locked,
there is no procedure available for unlocking the Customer Secured Silicon Sector area and none of the
bits in the Customer Secured Silicon Sector memory space can be modified in any way.
The accelerated programming (ACC) and unlock bypass functions are not available when programming the
Customer Secured Silicon Sector, but reading in Banks 1 through 15 is available.
Once the Customer Secured Silicon Sector is locked and verified, the system must write the Exit Secured
Silicon Sector Region command sequence which return the device to the memory array at sector 0.
10.3 Secured Silicon Sector Entry/Exit Command Sequences
The system can access the Secured Silicon Sector region by issuing the three-cycle Enter Secured Silicon
Sector command sequence. The device continues to access the Secured Silicon Sector region until the
system issues the four-cycle Exit Secured Silicon Sector command sequence.
See Command Definition Table [Secured Silicon Sector Command Table, Appendix
Table 12.1 on page 84 for address and data requirements for both command sequences.
The Secured Silicon Sector Entry Command allows the following commands to be executed
Read customer and factory Secured Silicon areas
Program the customer Secured Silicon Sector
After the system has written the Enter Secured Silicon Sector command sequence, it may read the Secured
Silicon Sector by using the addresses normally occupied by sector SA0 within the memory array. This mode
of operation continues until the system issues the Exit Secured Silicon Sector command sequence, or until
power is removed from the device.
Software Functions and Sample Code
The following are C functions and source code examples of using the Secured Silicon Sector Entry, Program,
and exit commands. Refer to the Spansion Low Level Driver User’s Guide (available soon on
www.spansion.com) for general information on Spansion Flash memory software development guidelines.
Note:
Base = Base Address.
/* Example: Secured Silicon Sector Entry Command */
*( (UINT16 *)base_addr + 0x555 ) = 0x00AA; /* write unlock cycle 1 */
*( (UINT16 *)base_addr + 0x2AA ) = 0x0055; /* write unlock cycle 2 */
*( (UINT16 *)base_addr + 0x555 ) = 0x0088; /* write Secured Silicon Sector Entry Cmd
*/
Table 10.2 Secured Silicon Sector Entry
(LLD Function = lld_SecSiSectorEntryCmd)
Cycle Operation Byte Address Word Address Data
Unlock Cycle 1 Write Base + AAAh Base + 555h 00AAh
Unlock Cycle 2 Write Base + 554h Base + 2AAh 0055h
Entry Cycle Write Base + AAAh Base + 555h 0088h
January 28, 2008 S29WS-P_00_A12 S29WS-P 65
Data Sheet
Note:
Base = Base Address.
/* Once in the Secured Silicon Sector mode, you program */
/* words using the programming algorithm. */
Note:
Base = Base Address.
/* Example: Secured Silicon Sector Exit Command */
*( (UINT16 *)base_addr + 0x555 ) = 0x00AA; /* write unlock cycle 1 */
*( (UINT16 *)base_addr + 0x2AA ) = 0x0055; /* write unlock cycle 2 */
*( (UINT16 *)base_addr + 0x555 ) = 0x0090; /* write Secured Silicon Sector Exit cycle
3 */
*( (UINT16 *)base_addr + 0x000 ) = 0x0000; /* write Secured Silicon Sector Exit cycle
4 */
Table 10.3 Secured Silicon Sector Program
(LLD Function = lld_ProgramCmd)
Cycle Operation Byte Address Word Address Data
Unlock Cycle 1 Write Base + AAAh Base + 555h 00AAh
Unlock Cycle 2 Write Base + 554h Base + 2AAh 0055h
Program Setup Write Base + AAAh Base + 555h 00A0h
Program Write Word Address Word Address Data Word
Table 10.4 Secured Silicon Sector Exit
(LLD Function = lld_SecSiSectorExitCmd)
Cycle Operation Byte Address Word Address Data
Unlock Cycle 1 Write Base + AAAh Base + 555h 00AAh
Unlock Cycle 2 Write Base + 554h Base + 2AAh 0055h
Exit Cycle 3 Write Base + AAAh Base + 555h 0090h
Exit Cycle 4 Write Any address Any address 0000h
66 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
11. Electrical Specifications
11.1 Absolute Maximum Ratings
Notes:
1. Minimum DC voltage on input or I/Os is –0.5 V. During voltage transitions, inputs or I/Os may undershoot VSS to –2.0 V for periods of up
to 20 ns. See Figure 11.1. Maximum DC voltage on input or I/Os is VCC + 0.5 V. During voltage transitions outputs may overshoot to VCC
+ 2.0 V for periods up to 20 ns. See Figure 11.2.
2. Minimum DC input voltage on pin ACC is -0.5V. During voltage transitions, ACC may overshoot VSS to –2.0 V for periods of up to 20 ns.
See Figure 11.1. Maximum DC voltage on pin ACC is +9.5 V, which may overshoot to 10.5 V for periods up to 20 ns.
3. No more than one output may be shorted to ground at a time. Duration of the short circuit should not be greater than one second.
4. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only;
functional operation of the device at these or any other conditions above those indicated in the operational sections of this data sheet is not
implied. Exposure of the device to absolute maximum rating conditions for extended periods may affect device reliability.
Figure 11.1 Maximum Negative Overshoot Waveform
Figure 11.2 Maximum Positive Overshoot Waveform
11.2 Operating Ranges
Note
Operating ranges define those limits between which the functionality of the device is guaranteed.
Storage Temperature Plastic Packages –65°C to +150°C
Ambient Temperature with Power Applied –65°C to +125°C
Voltage with Respect to Ground: All Inputs and I/Os except as noted below (Note 1) –0.5 V to + 2.5 V
VCC (Note 1) –0.5 V to +2.5 V
ACC (Note 2) –0.5 V to +9.5 V
Output Short Circuit Current (Note 3) 100 mA
20 ns
20 ns
+0.8 V
–0.5 V
20 ns
–2.0 V
20 ns
20 ns
VCC
+2.0 V
VCC
+0.5 V
20 ns
1.0 V
Wireless (I) Devices Ambient Temperature (TA) –25°C to +85°C
Supply Voltages VCC Supply Voltages +1.70 V to +1.95 V
January 28, 2008 S29WS-P_00_A12 S29WS-P 67
Data Sheet
11.3 DC Characteristics
11.3.1 CMOS Compatible
Notes:
1. Maximum ICC specifications are tested with VCC = VCCmax.
2. ICC active while Embedded Erase or Embedded Program is in progress.
3. Device enters automatic sleep mode when addresses are stable for tACC + 20 ns. Typical sleep mode current is equal to ICC3.
4. Total current during accelerated programming is the sum of VACC and VCC currents.
5. VCCQ = VCC during all ICC measurements.
6. VIH = VCC <Helv>± 0.2V and VIL
0.1V
Table 11.1 CMOS Compatible
Parameter Description Test Conditions (Note 1) Min Typ Max Unit
ILI Input Load Current VIN = VSS to VCC, VCC = VCCmax ±1 µA
ILO Output Leakage Current VOUT = VSS to VCC, VCC = VCCmax ±1 µA
ICCB VCC Active burst Read Current
CE# = VIL, OE# = VIH, WE# = VIH,
burst length = 8
54 Mhz 32 37 mA
66 Mhz 35 41 mA
80 Mhz 39 46 mA
104 Mhz 44 51 mA
CE# = VIL, OE# = VIH, WE# = VIH,
burst length = 16
54 Mhz 32 37 mA
66 Mhz 35 41 mA
80 Mhz 39 46 mA
104 Mhz 44 51 mA
CE# = VIL, OE# = VIH, WE# = VIH,
burst length = 32
54 Mhz 33 38 mA
66 Mhz 36 42 mA
80 Mhz 40 47 mA
104 Mhz 45 52 mA
CE# = VIL, OE# = VIH, WE# = VIH,
burst length = Continuous
54 Mhz 34 39 mA
66 Mhz 37 43 mA
80 Mhz 41 48 mA
104 Mhz 50 57 mA
ICC1
VCC Active Asynchronous Read
Current (Note 2) CE# = VIL, OE# = VIH, WE# = VIH
10 MHz 40 80 mA
5 MHz 20 40 mA
1 MHz 10 20 mA
ICC2
VCC Active Program/Erase
Current (Note 2) CE# = VIL, OE# = VIH, ACC = VIH
VACC 15µA
VCC 20 60 mA
ICC3 VCC Standby Current (Note 3) CE# = RESET# =
VCC ± 0.2 V
VACC 15µA
VCC 20 70 µA
ICC4 VCC Reset Current RESET# = VIL, CLK = VIL 30 60 µA
ICC5
VCC Active Current
(Read While Program/Erase) CE# = VIL, OE# = VIH, ACC = VIH, 5 MHz 40 60 mA
ICC6 VCC Sleep Current CE# = VIL, OE# = VIH, (VCCQ or VSSQ biased at Rail
to Rail for all inputs) 540µA
ICC7 VCC Active Page Read Current OE# = VIH, 8 word Page Read 10 15 mA
IACC
Accelerated Program Current
(Note 4)
CE# = VIL, OE# = VIH,
VACC = 9.5 V
VACC 710mA
VCC 15 20 mA
VIL Input Low Voltage –0.2 0.4 V
VIH Input High Voltage VCC
0.4
VCC +
0.4
VOL Output Low Voltage IOL = 100 µA, VCC = VCC min 0.1 V
VOH Output High Voltage IOH = –100 µA, VCC = VCC min
VCC
0.1 V
VHH Voltage for Accelerated Program 8.5 9.5 V
VLKO Low VCC Lock-out Voltage 1.4 V
68 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
11.4 Test Conditions
Figure 11.3 Test Setup
11.5 Key to Switching Waveforms
11.6 Switching Waveforms
Figure 11.4 Input Waveforms and Measurement Levels
Table 11.2 Test Specifications
Test Condition All Speed Options Unit
Output Load Capacitance, CL
(including jig capacitance) 30 pF
Input Rise and Fall Times 1.0 - 1.50 ns
Input Pulse Levels 0.0–VCC V
Input timing measurement reference levels VCC/2 V
Output timing measurement reference levels VCC/2 V
CL
Device
Under
Te s t
Waveform Inputs Outputs
Steady
Changing from H to L
Changing from L to H
Don’t Care, Any Change Permitted Changing, State Unknown
Does Not Apply Center Line is High Impedance State (High Z)
Table 11.3 VCC Power-up
Parameter Description Test Setup Time Unit
tVCS VCC Setup Time Min 30 µs
tRH Time between RESET# (high) and CE# (low) Min 200 ns
V
CC
0.0 V
OutputMeasurement LevelInput V
CC
/2 V
CC
/2All Inputs and Outputs
January 28, 2008 S29WS-P_00_A12 S29WS-P 69
Data Sheet
11.7 Power-up/Initialization
Power supply must reach its minimum voltage range before applying/removing the next supply voltage.
RESET# must ramp down to VIL level before VCC/VCCQ can start ramp up.
VCC and VCCQ must be ramped simultaneously for proper power-up.
The S29WS-P device ramp rate is > 1V/400 µs. For VCC ramp rate <1V/400 µs, a hardware reset is required.
Figure 11.5 VCC Power-up Diagram
11.8 CLK Characterization
Figure 11.6 CLK Characterization
VCC/ VCCQ
RESET#
tVCS
tRH
CE#
VCC min
VIH
Parameter Description 54 MHz 66 MHz 80 MHz 104 MHz Unit
fCLK CLK Frequency
Max546680 104 MHz
Min
60 KHz in 8 word Burst,
120 KHz in 16 word Burst,
250 KHz in 32 word Burst,
1 MHz in Continuous Mode
tCLK CLK Period Min 18.5 15.1 12.5 9.62 ns
tCL/tCH CLK Low/High Time Min 0.45 tCLK ns
Max 0.55 tCLK
tCR CLK Rise Time Max 3.0 3.0 2.5 1.5 ns
tCF CLK Fall Time
tCLK
tCL
tCH
tCR tCF
CLK
70 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
11.9 AC Characteristics
11.9.1 Synchronous/Burst Read
Notes:
1. Addresses are latched on the rising edge of CLK
2. Synchronous Access Time is calculated using the formula (#of WS - 1)*(clock period) + (tBACC or Clock to Out)
Parameter
Description 54 MHz 66 MHz 80 MHz 104 MHz UnitJEDEC Standard
tIACC Synchronous Access Time Max (WS-1) * tCK + tBACC ns
tBACC
Burst Access Time Valid Clock to Output
Delay Max 13.5 11.2 9 7.6 ns
tACS Address Setup Time to CLK (Note 1) Min 5 4 4 3.5 ns
tACH Address Hold Time from CLK (Note 1) Min 6 6 5 5 ns
tBDH Data Hold Time Min 4 3 3 2 ns
tRDY Chip Enable to RDY Active Max 10 ns
tOE Output Enable to RDY Low Max 13.5 11.2 9 7.6 ns
tCEZ Chip Enable to High Z Max 10 10 10 7 ns
tOEZ Output Enable to High Z Max 10 10 10 7 ns
tCES CE# Setup Time to CLK Min 6 ns
tRACC Ready Access Time from CLK Max 13.5 11.2 9 7.6 ns
tCAS CE# Setup Time to AVD# Min 0 ns
tAVC AVD# Low to CLK Setup Time Min 6 ns
tAVD AVD# Pulse Min tCLK ns
Table 11.4 Non-Continuous Burst Mode with Wrap Around Burst Mode.
Max Frequency Wait State Requirement
Frequency 27 MHz 3
27 MHz < Frequency 40 MHz 4
40 MHz < Frequency 54 MHz 5
54 MHz < Frequency 66 MHz 6
66 MHz < Frequency 80 MHz 7
80 MHz < Frequency 95 MHz 8
95 MHz < Frequency 104 MHz 11
Table 11.5 Continuous Burst Mode with No Wrap Around Burst Mode.
Max Frequency Wait State Requirement
Frequency 27 MHz 3
27 MHz < Frequency 40 MHz 4
40 MHz < Frequency 54 MHz 6
54 MHz < Frequency 66 MHz 7
67 MHz < Frequency 80 MHz 8
80 MHz < Frequency 95 MHz 9
95 MHz < Frequency 104 MHz 11
January 28, 2008 S29WS-P_00_A12 S29WS-P 71
Data Sheet
Figure 11.7 8-Word Linear Synchronous Single Data Rate Burst with Wrap Around
Notes:
1. Figure shows for illustration the total number of wait states set to seven cycles.
2. The device is configured synchronous single data rate mode and RDY active with data.
3. CE# (High) drives the RDY to Hi-Z while OE# (High) drives the DQ(15:0) pins to Hi-Z.
Figure 11.8 8-word Linear Single Data Read Synchronous Burst without Wrap Around
Notes:
1. Figure shows for illustration the total number of wait states set to seven cycles.
2. The device is configured synchronous single data rate mode and RDY active with data.
3. CE# (High) drives the RDY to Hi-Z while OE# (High) drives the DQ(15:0) pins to HI-Z.
DC DD
OE#
Data
Address
AC
AVD#
RDY
CLK
CE#
t
CES
t
ACS
t
AVC
t
AVD
t
ACH
t
OE
t
BDH
DE DB
7 cycles for initial access is shown as an illustration.
Hi-Z
t
RACC
1234567
t
BACC
t
RDY
t
IACC
tCLKH tCLKL
tCLK
High-Z
tCEZ
tOEZ
tCEZ
High-Z
DC DD
OE#
Data
Addresses Ac
AVD#
RDY
CLK
CE#
tCES
tACS
tAVC
tAVD
tACH
tOE
tIACC
tBDH
DE DF D13
7? cycles for initial access shown.
Hi-Z
tRACC
1234567
tRDYS
tBACC
tRDY
D10
tRACC
72 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
11.9.2 Asynchronous Mode Read
Figure 11.9 Asynchronous Read Mode (AVD# Toggling - Case 1)
Notes:
1. Valid Address and AVD# Transition occur before CE# is driven Low.
2. VA = Valid Read Address, RD = Read Data.
Parameter
Description Asynchronous UnitJEDEC Standard
tCE Access Time from CE# Low Max 83 ns
tACC Asynchronous Access Time Max 80 ns
tAVDP AVD# Low Time Min 7.5 ns
tAAVDS Address Setup Time to Rising Edge of AVD# Min 6 ns
tAAVDH Address Hold Time from Rising Edge of AVD# Min 4 ns
tOE Output Enable to Output Valid Max 13.5 ns
tOEH
Output Enable Hold
Time
Read Min 0 ns
Toggle and Data#
Polling Min 4 ns
tOEZ Output Enable to High Z Max 7.6 ns
tCAS CE# Setup Time to AVD# Min 0 ns
tPA C C Intra Page Access Time Max 20 ns
tCEZ Chip Enable to High Z Max 7.6 ns
CLK VIL or VIH
CE#
AVD #
OE#
WE#
DQ15-DQ0
Amax-A0
tOE
VA
RD
tCE tOEZ
Hi-Z
Hi-Z
RDY
tAV D P
tAAVDH
tCEZ
tCEZ
tRDY
tWEA
tOEH
tAAVDS
January 28, 2008 S29WS-P_00_A12 S29WS-P 73
Data Sheet
Figure 11.10 Asynchronous Read Mode (AVD# Toggling - Case 2)
Notes:
1. AVD# Transition occurs after CE# is driven to Low and Valid Address Transition occurs before AVD# is driven to Low.
2. VA = Valid Read Address, RD = Read Data.
Figure 11.11 Asynchronous Read Mode (AVD# Toggling - Case 3)
Notes:
1. AVD# Transition occurs after CE# is driven to Low and AVD# is driven low before Valid Address Transition.
2. VA = Valid Read Address, RD = Read Data.
CLK
V
IL or
V
IH
tOE
VA
RD
tOEZ
CE#
OE#
WE#
Amax-A0
AVD #
tAV D P
tAAVDH
DQ15-DQ0
tWEA
tCEZ
Hi-Z Hi-Z
RDY
tCAS
tRDY
tCEZ
tOEH
tAAVDS
tACC
CLK
V
tOE
VA
RD
tOEZ
CE#
OE#
WE#
Amax-A0
AVD #
tAV D P
tAAVDH
DQ15-DQ0
tWEA
tCEZ
Hi-Z Hi-Z
RDY
tCAS
tRDY
tCEZ
tOEH
tAAVDS
tACC
IL or
V
IH
74 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Figure 11.12 Asynchronous Read Mode (AVD# tied to CE#)
Notes:
1. AVD# is tied to CE#
2. VA = Valid Read Address, RD = Read Data.
Figure 11.13 Asynchronous Page Mode Read
Note
RA = Read Address, RD = Read Data.
CLK V
tRC
CE#
OE#
WE#
DQ15-DQ0
Amax-A0
tOE
VA
RD
tCE tOEZ
tACC
Hi-Z
Hi-Z
RDY
tCEZ
AVD #
tCEZ
tRDY
tOEH
tWEA
IL or VIH
Amax
-
A3
CE#
OE#
A2-A0
Data Bus
Page
A0 A1 A2 Ax
D0 D1 Dx D7
tACC
tPA C C tPA C C tPA C C
AVD#
January 28, 2008 S29WS-P_00_A12 S29WS-P 75
Data Sheet
11.9.3 Hardware Reset (RESET#)
Figure 11.14 Reset Timings
Table 11.6 Hardware Reset
Parameter
Description
All Speed
Options UnitJEDEC Std
tRP RESET# Pulse Width Min 30 µs
tRH Reset High Time Before Read Min 200 ns
RESET#
tRP
CE#, OE#
tRH
76 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
11.9.4 Erase/Program Timing
Notes
1. Sampled, not 100% tested.
2. In programming operations, addresses are latched on the active edge of CLK for programming synchronously or rising edge of AVD# for
programming asynchronously.
3. See the Erase and Programming Performance on page 83 section for more information. Does not include the preprogramming time.
Parameter
Description
54
MHz
66
MHz
80
MHz
104
MHz UnitJEDEC Standard
tAVAV tWC Write Cycle Time (Note 1) Min 60 ns
tAVWL tAS Address Setup Time (Note 2) Synchronous Min 5553.5
ns
Asynchronous 6666
tWLAX tAH Address Hold Time (Note 2) Synchronous Min 7765
ns
Asynchronous 7765
tAVDP AVD# Low Time Min 6 ns
tDVWH tDS Data Setup Time Min 20 ns
tWHDX tDH Data Hold Time Min 0 ns
tGHWL tGHWL Read Recovery Time Before Write Min 0 ns
tCAS CE# Setup Time to AVD# Min 0 ns
tWHEH tCH CE# Hold Time Min 0 ns
tWLWH tWP Write Pulse Width Min 25 ns
tWHWL tWPH Write Pulse Width High Min 20 ns
tSR/W Latency Between Read and Write Operations Min 0 ns
tVID VACC Rise and Fall Time Min 500 ns
tVIDS VACC Setup Time (During Accelerated Programming) Min 1 µs
tELWL tCS CE# Setup Time to WE# Min 4 ns
tAVSW AVD# Setup Time to WE# Min 4 ns
tAVHW AVD# Hold Time to WE# Min 4 ns
tAVSC AVD# Setup Time to CLK Min5553ns
tAVHC AVD# Hold Time to CLK Min5553ns
tSEA Sector Erase Accept Time-out Min 50 µs
tESL Erase Suspend Latency Max 40 µs
tPSL Program Suspend Latency Max 40 µs
tASP Toggle Time During Erase within a Protected Sector Typ 0 µs
tPSP Toggle Time During Programming Within a Protected Sector Typ 0 µs
January 28, 2008 S29WS-P_00_A12 S29WS-P 77
Data Sheet
Figure 11.15 Asynchronous Program Operation Timings
Notes:
1. PA = Program Address, PD = Program Data, VA = Valid Address for reading status bits.
2. In progress and complete refer to status of program operation.
3. CLK can be either VIL or VIH.
Figure 11.16 Synchronous Program Operation Timings
Notes:
1. PA = Program Address, PD = Program Data, VA = Valid Address for reading status bits.
2. In progress and complete refer to status of program operation.
3. Addresses are latched on the first rising edge of CLK.
OE#
CE#
Data
Addresses
AVD#
WE#
CLK
tAS
tWP
tAH
tWC
tWPH
PA
tCS
tDH
tCH
In
Progress
VA
Complete
VA
Program Command Sequence (last two cycles) Read Status Data
tDS
VIH
VIL
tAVDP
A0h
555h
PD
tCAS
OE#
CE#
Data
Addresses
AVD#
WE#
CLK
555h
PD
tWC
tWPH
tWP
PA
tDH
tCH
In
Progress
VA
Complete
VA
Program Command Sequence (last two cycles) Read Status Data
tDS
tAVDP
A0h
tAS
tCAS
tAH
tAVHC
tAVSC
tWC
tAVSW
tAVHW
78 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Figure 11.17 Chip/Sector Erase Command Sequence
Note:
SA is the sector address for Sector Erase.
Figure 11.18 Accelerated Unlock Bypass Programming Timing
Note:
Use setup and hold times from conventional program operation.
OE#
CE#
Data
Addresses
AVD#
WE#
CLK
t
AS
t
WP
t
AH
t
WC
t
WPH
SA
t
CS
t
DH
t
CH
In
Progress
t
WHWH2
VA
Complete
VA
Erase Command Sequence (last two cycles) Read Status Data
t
DS
10h for
chip erase
555h for
chip erase
V
IH
V
IL
t
AVDP
55h
2AAh
30h
CE#
AVD#
WE#
Addresses
Data
OE#
ACC
Don't Care Don't CareA0h Don't Care
PA
PD
V
HH
1 µs
V
IL
or V
IH
tVIDS
January 28, 2008 S29WS-P_00_A12 S29WS-P 79
Data Sheet
Figure 11.19 Data# Polling Timings (During Embedded Algorithm)
Notes:
1. Status reads in figure are shown as asynchronous.
2. VA = Valid Address. Two read cycles are required to determine status. When the Embedded Algorithm operation is complete, and Data#
Polling will output true data.
Figure 11.20 Toggle Bit Timings (During Embedded Algorithm)
Notes:
1. Status reads in figure are shown as asynchronous.
2. VA = Valid Address. Two read cycles are required to determine status. When the Embedded Algorithm operation is complete, the toggle
bits will stop toggling.
WE#
CE#
OE#
High Z
tOE
High Z
Addresses
AVD#
tOEH
tCE
tCH tOEZ
tCEZ
Status Data Status Data
tACC
VA VA
Data
WE#
CE#
OE#
High Z
tOE
High Z
Addresses
AVD#
tOEH
tCE
tCH tOEZ
tCEZ
Status Data Status Data
tACC
VA VA
Data
80 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Figure 11.21 Synchronous Data Polling Timings/Toggle Bit Timings
Notes:
1. The timings are similar to synchronous read timings.
2. VA = Valid Address. Two read cycles are required to determine status. When the Embedded Algorithm operation is complete, the toggle
bits will stop toggling.
3. RDY is active with data (D8 = 0 in the Configuration Register). When D8 = 1 in the Configuration Register, RDY is active one clock cycle
before data.
Figure 11.22 DQ2 vs. DQ6
Note:
DQ2 toggles only when read at an address within an erase-suspended sector. The system may use OE# or CE# to toggle DQ2 and DQ6.
CE#
CLK
AVD#
Addresses
OE#
Data
RDY
Status Data Status Data
VA VA
tIACC tIACC
Enter
Erase
Erase
Erase
Enter Erase
Suspend Program
Erase Suspend
Read Erase Suspend
Read
Erase
WE#
DQ6
DQ2
Erase
Complete
Erase
Suspend
Suspend
Program
Resume
Embedded
Erasing
January 28, 2008 S29WS-P_00_A12 S29WS-P 81
Data Sheet
Figure 11.23 Latency with Boundary Crossing
Notes:
1. RDY active with data (CR0.8 = 0 in the Configuration Register).
2. RDY active one clock cycle before data (CR0.8 = 1 in the Configuration Register).
3. Figure shows the device not crossing a bank in the process of performing an erase or program.
Figure 11.24 Wait State Configuration Register Setup
CLK
Address (hex)
D124 D125 D126 D127 D128 D129 D130
(stays high)
AVD#
RDY(Note 1)
Data
OE#,
CE# (stays low)
Address boundary occurs every 128 words, beginning at address
00007Fh: (0000FFh, 00017Fh, etc.) Address 000000h is also a boundary crossing.
7C 7D 7E 7F 7F 80 81 82 83
latency
RDY(Note 2) latency
tRACC tRACC
tRACC
tRACC
Invalid
Data
AVD#
OE#
CLK
12345
D0 D1
01
6
2
7
6
total number of clock cycles
following addresses being latched
Rising edge of next clock cycle
following last wait state triggers
next burst data
Total number of clock edges following addresses being latched
48
10 12 14
13
82 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Figure 11.25 Back-to-Back Read/Write Cycle Timings
Note:
Breakpoints in waveforms indicate that system may alternately read array data from the non-busy bank while checking the status of the
program or erase operation in the busy bank. The system should read status twice to ensure valid information.
Table 11.7 Example of Programmable Wait States
CR1.0
Programmable
Wait State
0000 = initial data is valid on the 2rd rising CLK edge after addresses are latched
0001 =initial data is valid on the 3rd rising CLK edge after addresses are latched
0010 = initial data is valid on the 4th rising CLK edge after addresses are latched
0011 = initial data is valid on the 5th rising CLK edge after addresses are latched
0100 = initial data is valid on the 6th rising CLK edge after addresses are latched
0101 = initial data is valid on the 7th rising CLK edge after addresses are latched
0110 = Reserved
0111 = Reserved
1000 = initial data is valid on the 8th rising CLK edge after addresses are latched
1001 = initial data is valid on the 9th rising CLK edge after addresses are latched
101 1= initial data is valid on the 10th rising CLK edge after addresses are latched
.
.
1101 = Reserved
1110 = Reserved
1111 = Reserved
CR0.13
CR0.12
CR0.11
OE#
CE#
WE#
tOEH
Data
Addresses
AVD#
PD/30h AAh
RA
PA/SA
tWC
tDS tDH
tRC tRC
tOE
tAS
tAH
tACC
tOEH
tWP
tGHWL
tOEZ
tWC
tSR/W
Last Cycle in
Program or
Sector Erase
Command Sequence
Read status (at least two cycles) in same bank
and/or array data from other bank
Begin another
write or program
command sequence
RD
RA 555h
RD
tWPH
January 28, 2008 S29WS-P_00_A12 S29WS-P 83
Data Sheet
11.10 Erase and Programming Performance
Notes:
1. Typical program and erase values are measured at TC = 25°C, 1.8 V VCC, 10,000 cycles using checkerboard patterns. Sampled, but not
100% tested.
2. Under worst case conditions of 90°C, VCC = 1.70 V, 100,000 cycles.
3. In the pre-programming step of the Embedded Erase algorithm, all words are programmed to 00h before erasure.
4. System-level overhead is the time required to execute the two- or four-bus-cycle sequence for the program command. See Table 12.1
on page 84 and Table 12.2 on page 86 for further information on command definitions.
11.10.1 BGA Ball Capacitance
Notes
1. Sampled, not 100% tested.
2. Test conditions tA - 25°C; f = 1.0 MHz
Parameter Typ (Note 1) Max (Note 2) Unit Comments
Sector Erase Time
64 Kword VCC 0.6 3.0
s
Excludes 00h
programming prior to
erasure (Note 3)
16 Kword VCC 0.35 1.75
Chip Erase Time VCC
78.4 (WS128P)
155.2 (WS256P)
308.8 (WS512P)
154 (WS128P)
308 (WS256P)
616 (WS512P)
s
Single Word Programming Time VCC 40 400
µs Excludes system level
overhead (Note 4)
ACC 24 240
Effective Word Programming Time
utilizing Program Write Buffer
VCC 9.4 94
µs
ACC 6 60
Total 32-Word Buffer Programming
Time
VCC 300 3000
ACC 192 1920
Chip Programming Time (using 32
word buffer)
VCC
50.4 (WS128P)
100.8 (WS256P)
201.6 (WS512P)
157.3 (WS128P)
314.6 (WS256P)
1008 (WS512P) sExcludes system level
overhead (Note 4)
ACC
33.6 (WS128P)
67.2 (WS256P)
134.4 (WS512P)
100.7 (WS128P)
201.3 (WS256P)
402.6 (WS512P)
Erase Suspend/Erase Resume (tERS)40 µs
Program Suspend/Program Resume
(tPRS)40 µs
Parameter Symbol
Parameter
Description Test Setup Typ Max Unit
CIN Input Capacitance VIN = 0 2 10 pF
COUT Output Capacitance VOUT = 0 2 10 pF
84 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
12. Appendix
This section contains information relating to software control or interfacing with the Flash device. For
additional information and assistance regarding software, see Additional Resources on page 15, or explore
the Web at www.spansion.com.
Legend
X = Don’t care
RA = Read Address
RD = Read Data
PA = Program Address. Addresses latch on the rising edge of the AVD# pulse or active edge of CLK, whichever occurs first.
PD = Program Data. Data latches on the rising edge of WE# or CE# pulse, whichever occurs first.
Notes
1. See Table 7.1 on page 19 for description of bus operations.
2. All values are in hexadecimal.
3. Except for the following, all bus cycles are write cycle: read cycle, fourth through sixth cycles of the Autoselect commands, fourth cycle of the configuration
register verify and password verify commands, and any cycle reading at RD(0) and RD(1).
4. Data bits DQ15–DQ8 are don’t care in command sequences, except for RD, PD, WD, PWD, and PWD3-PWD0.
5. Unless otherwise noted, address bits Amax–A14 are don’t cares.
Table 12.1 Memory Array Commands
Command Sequence
(Notes)
Cycles
Bus Cycles (Note 1 - 6)
First Second Third Fourth Fifth Sixth
Addr
Data
(19) Addr
Data
(19) Addr
Data
(19) Addr
Data
(19) Addr
Data
(19) Addr
Data
(19)
Asynchronous Read (7) 1RA RD
Reset (8) 1 XXX F0
Autoselect (9)
Manufacturer ID 4 555 AA 2AA 55 (BA)
555 90 (BA)
X00 0001
Device ID (10) 6 555 AA 2AA 55 (BA)
555 90 (BA)
X01 227E (BA)X
0E (10) (BA)
X0F (10)
Indicator Bits 4 555 AA 2AA 55 (BA)
555 90 (BA)
X03 (12)
Sector Unlock/Lock Verify
(11) 4 555 AA 2AA 55 (SA)
555 90 (SA)
X02
0000/
0001
Single word 4 555 AA 2AA 55 555 A0 PA Data
Write Buffer to Flash Program (17) 6 555 AA 2AA 55 SA 25 SA WC PA
(20) PD WBL PD
Program Buffer to Flash 1 SA 29
Write to Buffer Abort Reset (12) 3 555 AA 2AA 55 555 F0
Chip Erase 6 555 AA 2AA 55 555 80 555 AA 2AA 55 555 10
Sector Erase 6 555 AA 2AA 55 555 80 555 AA 2AA 55 SA 30
Program/Erase Suspend (15) 1BA B0
Program/Erase Resume (16) 1BA 30
Set Configuration Register (21) 5 555 AA 2AA 55 555 D0 X00 CR0 X01 CR1
Read Configuration Register 4 555 AA 2AA 55 555 C6
X0
(0 or
1)
CR
(0 or
1)
CFI Query (17) 1(BA)
55 98
Unlock Bypass
Mode
Unlock Bypass Entry (18) 3 555 AA 2AA 55 555 20
Unlock Bypass Program (13,
14)2XX A0 PA PD
Unlock Bypass Sector Erase
(13, 14)2XX80SA30
Unlock Bypass Erase (13,
14)2XX 80XXX 10
Unlock Bypass CFI (13, 14)1 XX 98
Unlock Bypass Reset 2 XX 90 XXX 00
January 28, 2008 S29WS-P_00_A12 S29WS-P 85
Data Sheet
6. Writing incorrect address and data values or writing them in the improper sequence may place the device in an unknown state. The system must write the reset
command to return the device to reading array data.
7. No unlock or command cycles required when bank is reading array data.
8. The Reset command is required to return to reading array data (or to the erase-suspend-read mode if previously in Erase Suspend) when a bank is in the
autoselect mode, or if DQ5 goes high (while the bank is providing status information) or performing sector lock/unlock.
9. The fourth cycle of the autoselect address is a read cycle. The system must provide the bank address.
10. (BA) + 0Eh ----> For WS128 = 2244h, WS256 = 2242h, WS512 = 223Dh. (BA) + 0Fh ----> For WS064/128/256/512 = 2200h
11. The data is 0000h for an unlocked sector and 0001h for a locked sector
12. See Table 7.32, Autoselect Addresses on page 32.
13. The Unlock Bypass command sequence is required prior to this command sequence.
14. The Unlock Bypass Reset command is required to return to reading array data when the bank is in the unlock bypass mode.
15. The system may read and program in non-erasing sectors, or enter the autoselect mode, when in the Erase Suspend mode. The Program/Erase Suspend
command is valid only during a program/ erase operation, and requires the bank address.
16. The Program/Erase Resume command is valid only during the Program/Erase Suspend mode, and requires the bank address.
17. The total number of cycles in the command sequence is determined by the number of words written to the write buffer. The maximum number of cycles in the
command sequence is 37.
18. Write Buffer Programming can be initiated after Unlock Bypass Entry.
19. Data is always output at the rising edge of clock.
20. Must be the lowest address.
21. Configuration Registers can not be programmed out of order. CR0 must be programmed prior to CR01 otherwise the configuration registers will retain their
previous settings
86 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Table 12.2 Sector Protection Commands (Sheet 1 of 2)
Command Sequence
(Notes)
Cycles
Bus Cycles (Note 1 - 6)
First Second Third Fourth Fifth Sixth Seventh
Addr
Data
(10) Addr
Data(
(10) Addr
Data(
(10) Addr
Data(
(10) Addr
Data(
(10) Addr
Data(
(10) Addr
Data(
(10)
Secured
Silicon Sector
Entry (5) 3 555 AA 2AA 55 555 88
Program 4 555 AA 2AA 55 555 A0 PA PD
Read 1 SA data
Exit (7) 4 555 AA 2AA 55 555 90 XX 00
Lock Register
Register Command Set
Entry (5) 3 555 AA 2AA 55 555 40
Register Bits Program (6) 2 XX A0 00 data
Register Bits Read 1 00 data
Register Command Set
Exit (7) 2XX 90 XX 00
Password
Protection Command Set
Entry 3 555 AA 2AA 55 555 60
Program (9) 2XX A0
00/
01/
02/
03
PWD
0/
1/
2/
3/
Read Password (10) 400
PWD
001 PWD
102 PWD
203 PWD
3
Unlock (9) 70025000300
PWD
001 PWD
102 PWD
203 PWD
300 29
Protection Command Set
Exit 2XX 90 XX 00
PPB
Non-Volatile Sector
Protection Command Set
Entry (5)
3 555 AA 2AA 55 (BA)
555 C0
Program 2 XX A0 (BA)
SA 00
All Erase (8) 2XX 80 XX 30
Status Read 1 (BA)
SA RD(0)
Non-Volatile Sector
Protection Command Set
Exit (7)
2XX 90 XX 00
PPB Lock Bit
Global Volatile Sector
Protection Freeze
Command Set Entry (5)
3 555 AA 2AA 55 555 50
Set 2 XX A0 XX 00
Status Read 1 XX RD(0)
Global Volatile Sector
Protection Freeze
Command Set Exit (7)
2XX 90 XX 00
DYB
Volatile Sector Protection
Command Set Entry (5) 3 555 AA 2AA 55 (BA)
555 E0
Set 2 XX A0 (BA)
SA 00
Clear 2 XX A0 (BA)
SA 01
Status Read 1 (BA)
SA RD(0)
Volatile Sector Protection
Command Set Exit (7) 2XX 90 XX 00
January 28, 2008 S29WS-P_00_A12 S29WS-P 87
Data Sheet
Legend
X = Don’t care
RA = Read Address
RD = Read Data
PA = Program Address. Addresses latch on the rising edge of the AVD# pulse or active edge of CLK, whichever occurs first.
PD = Program Data. Data latches on the rising edge of WE# or CE# pulse, whichever occurs first.
SA = Sector Address: WS128P = A22–A14, WS256P = 23–A14
BA = Bank Address: WS128P = A22-A20, and A19; WS256P = A23-A20
CR = Configuration Register data bits D15–D0
PWD3–PWD0 = Password Data. PD3–PD0 present four 16 bit combinations that represent the 64-bit Password.
PWA = Password Address. Address bits A1 and A0 are used to select each 16-bit portion of the 64-bit entity.
PWD = Password Data
RD(0) = DQ0 protection indicator bit. If protected, DQ0 = 0, if unprotected, DQ0 = 1.
WBL = Write Buffer Location. Address must be within the same write buffer page as PA.
WC = Word Count. Number of write buffer locations to load minus 1.
Notes
1. See Table 7.1 for description of bus operations.
2. All values are in hexadecimal.
3. Except for the following, all bus cycles are write cycle: read cycle, fourth through sixth cycles of the Autoselect commands, fourth cycle of the configuration
register verify and password verify commands, and any cycle reading at RD(0) and RD(1).
4. Data bits DQ15–DQ8 are don’t care in command sequences, except for RD, PD, WD, PWD, and PWD3-PWD0.
5. Entry commands are required to enter a specific mode to enable instructions only available within that mode.
6. If both the Persistent Protection Mode Locking Bit and the Password Protection Mode Locking Bit are set at the same time, the command operation aborts and
returns the device to the default Persistent Sector Protection Mode during 2nd bus cycle. Note that on all future devices, addresses equal 00h, but is currently
77h for the WS512P only.
7. Exit command must be issued to reset the device into read mode; device may otherwise be placed in an unknown state.
8. “All PPB Erase” command pre-programs all PPBs before erasure to prevent over-erasure.
9. Entire two bus-cycle sequence must be entered for each portion of the password.
10. Full address range is required for reading password.
Accelerated
Program 2 555 A0 PA Data
Sector Erase 2 555 80 SA 30
Chip Erase 2 555 80 555 10
Asynchronous Read 1 RA RD
Write to Buffer 4 SA 25 SA WC PA PD WBL PD
Program Buffer to Flash 1 SA 29
Table 12.2 Sector Protection Commands (Sheet 2 of 2)
Command Sequence
(Notes)
Cycles
Bus Cycles (Note 1 - 6)
First Second Third Fourth Fifth Sixth Seventh
Addr
Data
(10) Addr
Data(
(10) Addr
Data(
(10) Addr
Data(
(10) Addr
Data(
(10) Addr
Data(
(10) Addr
Data(
(10)
88 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
12.1 Common Flash Memory Interface
The Common Flash Interface (CFI) specification outlines device and host system software interrogation
handshake, which allows specific vendor-specified software algorithms to be used for entire families of
devices. Software support can then be device-independent, JEDEC ID-independent, and forward- and back-
ward-compatible for the specified flash device families. Flash vendors can standardize their existing
interfaces for long-term compatibility.
This device enters the CFI Query mode when the system writes the CFI Query command, 98h, to address
(BA)555h any time the device is ready to read array data. The system can read CFI information at the
addresses given in Tables 12.3–12.6 within that bank. All reads outside of the CFI address range, within the
bank, returns non-valid data. Reads from other banks are allowed, writes are not. To terminate reading CFI
data, the system must write the reset command.
The following is a C source code example of using the CFI Entry and Exit functions. Refer to the Spansion
Low Level Driver User’s Guide (available on www.spansion.com) for general information on Spansion Flash
memory software development guidelines.
/* Example: CFI Entry command */
*( (UINT16 *)bank_addr + 0x555 ) = 0x0098; /* write CFI entry command */
/* Example: CFI Exit command */
*( (UINT16 *)bank_addr + 0x000 ) = 0x00F0; /* write cfi exit command */
For further information, please refer to the CFI Specification (see JEDEC publications JEP137-A and
JESD68.01). Please contact your sales office for copies of these documents.
Table 12.3 CFI Query Identification String
Addresses Data Description
10h
11h
12h
0051h
0052h
0059h
Query Unique ASCII string QRY
13h
14h
0002h
0000h Primary OEM Command Set
15h
16h
0040h
0000h Address for Primary Extended Table
17h
18h
0000h
0000h Alternate OEM Command Set (00h = none exists)
19h
1Ah
0000h
0000h Address for Alternate OEM Extended Table (00h = none exists)
Table 12.4 System Interface String
Addresses Data Description
1Bh 0017h VCC Min. (write/erase)
D7–D4: volt, D3–D0: 100 millivolt
1Ch 0019h VCC Max. (write/erase)
D7–D4: volt, D3–D0: 100 millivolt
1Dh 0000h VPP Min. voltage (00h = no VPP pin present)
1Eh 0000h VPP Max. voltage (00h = no VPP pin present)
1Fh 0005h Typical Program Time per single word write 2N µs (e.g. 30us)
20h 0009h Typical Program Time using buffer 2N µs (e.g. 300us) (00h = not supported)
21h 000Ah Typical time for sector erase 2N ms
22h 0000h Typical time for full chip erase 2N ms (00h = not supported)
23h 0003h Max. Program Time per single word [2N times typical value]
24h 0003h Max. Program Time using buffer [2N times typical value]
25h 0003h Max. time for sector erase [2N times typical value]
26h 0000h Max. time for full chip erase [2N times typical value] (00h = not supported)
January 28, 2008 S29WS-P_00_A12 S29WS-P 89
Data Sheet
Table 12.5 Device Geometry Definition
Addresses Data Description
27h
0018h (WS128P)
0019h (WS256P)
001Ah (WS512P)
Device Size = 2N byte
28h
29h
0001h
0000h
Flash Device Interface 0h=x8; 1h=x16; 2h=x8/x16; 3h=x32 [lower byte]
[upper byte] (00h = not supported)
2Ah
2Bh
0006h
0000h
Max. number of bytes in multi-byte buffer write = 2N [lower byte]
[upper byte] (00h = not supported)
2Ch 0003h Number of Erase Block Regions within device
01h = Uniform Sector; 02h = Boot + Uniform; 03h = Boot + Uniform + Boot
2Dh
2Eh
2Fh
30h
0003h
0000h
0080h
0000h
Erase Block Region 1 Information (Small Sector Section)
[lower byte] - Number of sectors. 00h=1 sector; 01h=2 sectors ... 03h=4 sectors
[upper byte]
[lower byte] - Equation =>(n = Density in Bytes of any 1 sector/256)h
[upper byte]
31h
32h
33h
34h
007Dh (WS128P)
00FDh (WS256P)
00FDh (WS512P)
0001h
0000h
0002h
Erase Block Region 2 Information (Large Sector Section)
[lower byte] - Number of sectors.
[upper byte]
[lower byte] - Equation =>(n = Density in Bytes of any 1 sector/256)h
[upper byte]
35h
36h
37h
38h
0003h
0000h
0080h
0000h
Erase Block Region 3 Information (Small Sector Section)
[lower byte] - Number of sectors. 00h=1 sector; 01h=2 sectors ... 03h=4 sectors
[upper byte]
[lower byte] - Equation =>(n = Density in Bytes of any 1 sector/256)h
[upper byte]
39h
3Ah
3Bh
3Ch
0000h
0000h
0000h
0000h
Erase Block Region 4 Information
90 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Table 12.6 Primary Vendor-Specific Extended Query (Sheet 1 of 2)
Addresses Data Description
40h
41h
42h
0050h
0052h
0049h
Query-unique ASCII string PRI
43h 0031h Major CFI version number, ASCII
44h 0034h Minor CFI version number, ASCII
45h 0101b
Address Sensitive Unlock (Bits 1-0)
00b = Required, 01b = Not Required
Silicon Technology (Bits 5-2) 0011b = 130nm; 0100b = 110nm; 0101b = 90nm
001010b = 000Ah
46h 0002h Erase Suspend
0 = Not Supported, 1 = To Read Only, 2 = To Read & Write
47h 0001h Sector Protection per Group
0 = Not Supported, X = Number of sectors in per group
48h 0000h Sector Temporary Unprotect
00 = Not Supported, 01 = Supported
49h 0008h Sector Protect/Unprotect scheme
08h = Advanced Sector Protection; 07h = New Sector Protection Scheme
4Ah
07Bh (WS128P)
0F3h (WS256P)
1E3h (WS512P)
Simultaneous Operation
Number of Sectors in all banks except boot bank
4Bh 0001h Burst Mode Type
00 = Not Supported, 01 = Supported
4Ch 0002h Page Mode Type
00 = Not Supported, 01 = 4 Word Page, 02 = 8 Word Page, 04 = 16 Word Page
4Dh 0085h ACC (Acceleration) Supply Minimum
00h = Not Supported, D7-D4: Volt, D3-D0: 100 mV
4Eh 0095h ACC (Acceleration) Supply Maximum
00h = Not Supported, D7-D4: Volt, D3-D0: 100 mV
4Fh 0001h Write Protect Function
00h = No Boot, 01h = Dual Boot, 02h = Bottom Boot, 03h = Top Boot
50h 0001h Program Suspend. 00h = not supported
51h 0001h Unlock Bypass
00 = Not Supported, 01=Supported
52h 0008h Secured Silicon Sector (Customer OTP Area) Size 2N bytes
53h 0014h Hardware Reset Low Time-out during an embedded algorithm to read mode Maximum 2N
ns (e.g. 10us => n=14)
54h 0014h Hardware Reset Low Time-out not during an embedded algorithm to read mode Maximum
2N ns (e.g. 10us => n=14)
55h 0005h Erase Suspend Time-out Maximum 2N µs
56h 0005h Program Suspend Time-out Maximum 2N µs
57h 0010h Bank Organization: X = Number of banks
58h
0007h (WS064P)
000Bh (WS128P)
0013h (WS256P)
0023h (WS512P)
Bank 0 Region Information. X = Number of sectors in bank
59h
0004h (WS064P)
0008h (WS128P)
0010h (WS256P)
0020h (WS512P)
Bank 1 Region Information. X = Number of sectors in bank
5Ah
0004h (WS064P)
0008h (WS128P)
0010h (WS256P)
0020h (WS512P)
Bank 2 Region Information. X = Number of sectors in bank
5Bh
0008h (WS128P)
0010h (WS256P)
0020h (WS512P)
Bank 3 Region Information. X = Number of sectors in bank
January 28, 2008 S29WS-P_00_A12 S29WS-P 91
Data Sheet
5Ch
0008h (WS128P)
0010h (WS256P)
0020h (WS512P)
Bank 4 Region Information. X = Number of sectors in bank
5Dh
0008h (WS128P)
0010h (WS256P)
0020h (WS512P)
Bank 5 Region Information. X = Number of sectors in bank
5Eh
0008h (WS128P)
0010h (WS256P)
0020h (WS512P)
Bank 6 Region Information. X = Number of sectors in bank
5Fh
0008h (WS128P)
0010h (WS256P)
0020h (WS512P)
Bank 7 Region Information. X = Number of sectors in bank
60h
0008h (WS128P)
0010h (WS256P)
0020h (WS512P)
Bank 8 Region Information. X = Number of sectors in bank
61h
0008h (WS128P)
0010h (WS256P)
0020h (WS512P)
Bank 9 Region Information. X = Number of sectors in bank
62h
0008h (WS128P)
0010h (WS256P)
0020h (WS512P)
Bank 10 Region Information. X = Number of sectors in bank
63h
0008h (WS128P)
0010h (WS256P)
0020h (WS512P)
Bank 11 Region Information. X = Number of sectors in bank
64h
0008h (WS128P)
0010h (WS256P)
0020h (WS512P)
Bank 12 Region Information. X = Number of sectors in bank
65h
0008h (WS128P)
0010h (WS256P)
0020h (WS512P)
Bank 13 Region Information. X = Number of sectors in bank
66h
0008h (WS128P)
0010h (WS256P)
0020h (WS512P)
Bank 14 Region Information. X = Number of sectors in bank
67h
000Bh (WS128P)
0013h (WS256P)
0023h (WS512P)
Bank 15 Region Information. X = Number of sectors in bank
Table 12.6 Primary Vendor-Specific Extended Query (Sheet 2 of 2)
Addresses Data Description
92 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
13. Revision History
Section Description
Revision A6 (November 3, 2006)
Features Removed Zero Hold mode
Switching Waveforms Revised VCC Power-up diagram
Timing Diagrams Changed tCR to tRDY in figure 11.7 and figure 11.8
Revision A7 (November 8, 2006)
Features Updated Effective Write Buffer Programming Per Word
Erase/Program Timing tESL changed to Max
tPSL changed to Max
CMOS Compatible Removed Note 2 from table.
Revision A8 (March 9, 2007)
Asynchronous Mode Read Changed tCR to tRDY in figures 11.9 through 11.12
Common Flash Memory Interface
Revised Device Geometry table:
Changed WS512P data to 00FDh
Address 32h - Data changed to 001h
Address 33h - Data changed to 000h
Address 34h - Data changed to 002h
Revised CFI table: removed Uniform Bottom, Uniform Top, and All sectors for Address 4Fh
DC Characteristics Revised ICCB Burst table
Revision A9 (March 28, 2007)
DC Characteristics Revised ICCB for 108 MHz frequencies to TBA
Synchronous/Burst Read Revised tRACC to 7.6 ns
Asynchronous Mode Read Revised tAAVDH to 4 ns
Revision A10 (April 20, 2007)
AC Characteristics
Removed wait state below 14 MHz, wait state 2
Added additional wait state to all wait state frequency in table 11.4
Added Continuous Burst Mode Synchronous Wait State Requirement table
Revised Burst Access Time to (WS-1) * tCK + (tBACC)
Revision A11 (September 28, 2007)
Data Sheet Status Changed to Production
Global Changed all 108 MHz to 104 MHz
Latency Added 10 wait state and 11 wait state latency tables
Configuration Registers Added two more configurations to CR0.11 for 10th and 11th rising CLK edge
AC Characteristics Revised tCES to 6 ns
Revised tAVD to tCLK
DC Characteristics Changed description of ICC2 to VCC Active Program/Erase Current
Change descritpion of ICC5 to VCC Active Current (Read while Program/Erase)
Erase/Program Timing and
Performance
Revised:
tERS to 40 µs
tESL to 40 µs
tPSL to 40 µs
tPRS to 40 µs
Output Slew Rate Deleted Programmable Outuput Slew Rate Control section
Revision A12 (January 28, 2008)
Configuration Registers Changed CR0.14 default setting to 1
January 28, 2008 S29WS-P_00_A12 S29WS-P 93
Data Sheet
AC Characteristics
Added device Vcc ramp rate limit. Updated timing diagrams for Synchronous/Burst Read,
Asynchronous Program Operation, Synchronous Program Operation, and Chip Sector Erase
Command Sequence.
Program/Erase Operations Added details to Program and Erase Suspend/Resume operations
Section Description
94 S29WS-P S29WS-P_00_A12 January 28, 2008
Data Sheet
Colophon
The products described in this document are designed, developed and manufactured as contemplated for general use, including without
limitation, ordinary industrial use, general office use, personal use, and household use, but are not designed, developed and manufactured as
contemplated (1) for any use that includes fatal risks or dangers that, unless extremely high safety is secured, could have a serious effect to the
public, and could lead directly to death, personal injury, severe physical damage or other loss (i.e., nuclear reaction control in nuclear facility,
aircraft flight control, air traffic control, mass transport control, medical life support system, missile launch control in weapon system), or (2) for
any use where chance of failure is intolerable (i.e., submersible repeater and artificial satellite). Please note that Spansion will not be liable to
you and/or any third party for any claims or damages arising in connection with above-mentioned uses of the products. Any semiconductor
devices have an inherent chance of failure. You must protect against injury, damage or loss from such failures by incorporating safety design
measures into your facility and equipment such as redundancy, fire protection, and prevention of over-current levels and other abnormal
operating conditions. If any products described in this document represent goods or technologies subject to certain restrictions on export under
the Foreign Exchange and Foreign Trade Law of Japan, the US Export Administration Regulations or the applicable laws of any other country,
the prior authorization by the respective government entity will be required for export of those products.
Trademarks and Notice
The contents of this document are subject to change without notice. This document may contain information on a Spansion product under
development by Spansion. Spansion reserves the right to change or discontinue work on any product without notice. The information in this
document is provided as is without warranty or guarantee of any kind as to its accuracy, completeness, operability, fitness for particular purpose,
merchantability, non-infringement of third-party rights, or any other warranty, express, implied, or statutory. Spansion assumes no liability for any
damages of any kind arising out of the use of the information in this document.
Copyright © 2006-2008 Spansion Inc. All rights reserved. Spansion®, the Spansion Logo, MirrorBit®, MirrorBit® Eclipse, ORNAND, HD-SIM
and combinations thereof, are trademarks of Spansion LLC in the US and other countries. Other names used are for informational purposes
only and may be trademarks of their respective owners.