P F C UNIVERTER ®S E R I E S
375-1000 WATTS 85-265VAC INPUT 3/4 & FULL BRICK POWER FACTOR
MODEL SELECTION
Model Input Output Output
Number Voltage Voltage Power*
PFC-650 85-265VAC 375VDC 650 Watts
PFC-1000 170-265VAC 380VDC 1000 Watts
* See Derating Specication
DESCRIPTION
UniVerter PFC modules accept 85-265 VAC
(PFC-600, PFC-650) or 170-265 VAC (PFC-1000) and
convert it to 380 VDC to power 300VDC input
DC-DC converters. Power factor correction
meets low harmonic distortion requirements
of IEC 1000-3-2 and the European EN55022
emissions speci cation when used with the
Model HH-1199-6 EMI lter. UniVerter modules
utilize a boost converter incorporating a solid
state series switch for active inrush and short
circuit current limiting. The series switch is
also used to provide over temperature
shutdown with automatic recovery.
FEATUR ES
600, 650 & 1000 Watts
UL/CSA/TUV/CE MARK
Meets European EN55022 Emissions
when used with HH-1199-6 EMI Filter
Unity Power Factor
Active Inrush Limiting and Short Circuit
Protection
Very Low Harmonic Distortion
Auxiliary Supply
Power Fail Warning Via DC OK Signal
Load Enable Signal to Control DC-DC
Converters
Very Low Thermal Resistance
Superior Thermal Design
100°C Baseplate Operation
PFC-600 85-265VAC 380VDC 600 Watts
Visit www.astrodyne.com. Call toll free 800-823-8082. Email sales@astrodyne.com
PFC UNIVERTER SERIES SPECIFICATIONS
PFC-600 PFC-1000
Power (Watts) 600 W 1000 W
Derate output power linearly below Derate output power linearly below
105 VAC from 600W at 105 VAC 205 VAC from 1000W at 205 VAC
to 400W at 85 VAC to 750W at 170 VAC
Input Range 85-265 VAC 170-265 VAC
Input Frequency 47-63 Hz (operation up to 440Hz is 47-63 Hz (operation up to 440Hz is
available with reduced speci cations) available with reduced speci cations)
Power Factor .99 .99
Harmonic Distortion <5% (conforming to IEC 1000-3-2) <5% (conforming to IEC 1000-3-2)
Output Voltage 380 VDC 380 VDC
Eciency See Curves on Page 79 90/94 % (120/240 VAC) typical 94 % (240 VAC input)
Inrush Limiting <15 A peak typical 30 A (max)
Short Circuit Protection Trip point 1.8 A (Shutdown, automatic 2.8 A (Shutdown, automatic
recovery after removal of short) recovery after removal of short)
Thermal Protection 105-110 °C 105-110 °C
(Shutdown, automatic recovery) (Shutdown, automatic recovery)
Auxiliary Supply 14 V @ 10 mA 14 V, @10 mA
DC OK Signal Provides power fail warning when Provides power fail warning when
output drops below 355VDC output drops below 355VDC
Load Enable Direct interface with MicroVerter, Direct interface with MicroVerter
MegaVerter and PicoVerter DC-DC MegaVerter and PicoVerter DC-DC
Converter logic on/o pin Converter logic on/o pin
Operating Temp. -40 to +100 °C Case -40 to +100 °C Case
Overvoltage Protection 415 VDC non-shutdown 415 VDC non-shutdown
Safety UL1950, CSA22.2-234-M90, UL1950, CSA22.2-234-M90,
EN 60950 EN 60950
Thermal Resistance (Case To Ambient) 3.3 °C/W 3.3 °C/W
Isolation: Input-Output Non-isolated Non-isolated
Input/Output-Case 2500 VDC 2500 VDC
SYSTEM D IAGRAM
RO Associates | Tel: 408.744.1450 | Fax: 408.744.1521 | email: sales@roassoc.com
43
AC INPUT EMI
FILTER
UNIVERTER
POWER
FACTOR
CORRECTION
MODULE
HOLD UP
CAP
300V INPUT DC-DC
CONVERTER MODULE
300V INPUT DC-DC
CONVERTER MODULE
300V INPUT DC-DC
CONVERTER MODULE