TITLE
SPECIFICATION CONTROL DRAWING
COMPONENT WIRES -
1 of WTC-0013 (CHROMEL®)
1 of WTC-0014 (ALUMEL®)
SHIELD - TIN-COATED COPPER
PART NUMBER
1/
MAXIMUM 16.1
22.9
30.8
44.6
22
20
18
16
CTC-0039-22-*
CTC-0039-20-*
CTC-0039-18-*
CTC-0039-16-*
CONDUCTOR
SIZE
(AWG) MINIMUM NOMINAL
.010
.010
.010
.012
38
36
36
36
.012
.012
.012
.014
MAXIMUM
WEIGHT
(lbs/1000 ft.)
NOMINAL .167
.187
.211
.245
.159
.179
.201
.233
This specification sheet forms a part of the latest issue of Raychem Specification 55A.
Date Revision H
10-9-04
CTC-0039
TWO CONDUCTOR THERMOCOUPLE EXTENSION CABLE,
SHIELDED, JACKETED
OUTSIDE DIAMETER
(inch)
CABLE CONSTRUCTION DETAILS
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
ACCELERATED AGING: 300 ± 3°C for 7 hours
DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz
FLAMMABILITY: Procedure 1, 3 seconds (maximum);
3 in. (maximum); no flaming of facial
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 50% (minimum)
Tensile Strength, 5000 lbf/in2 (minimum)
JACKET FLAWS:
Spark Test, 1000 volts (rms)
Impulse Dielectric Test, 6.0 kV (peak)
LOW TEMPERATURE-COLD BEND: -65 ± 2°C for 4 hours
SHIELD COVERAGE: 85% (minimum)
VOLTAGE WITHSTAND TEST (Post Environmental):
1000 volts (rms), 60 Hz, 1 minute
JACKET THICKNESS
(inch)
SHIELD
SIZE
(AWG)
JACKET - RADIATION-CROSSLINKED
MODIFIED ETFE
PRODUCT IDENTIFICATION: The cable jacket shall be marked
in contrasting ink at 6 in. (nominal) intervals between marks
as follows: " CTC-0039-**-06090 "
The "**" in the product identification shall be replaced by the
AWG size, color sequence of components, and jacket color.
For example, if AWG size is 16 and color code is per
MIL-STD-687, the "**" should be replaced with "16-9/5-9".
PART NUMBER
The "*" in the part numbers above shall be replaced by
color code designators with a slash separating the
component wire colors and a dash separating the
component wire colors from the jacket color. The color
of CHROMEL® shall be shown first.
1/ Example: AWG 16,
Per MIL-STD-687: white and green; white jacket:
CTC-00395-16-9/5-9
Per ANSI MC 96.1: yellow and red;yellow jacket:
CTC-0039-16-4/2-4
Per British Standard Code BS:
brown and blue; red Jacket:
CTC-0039-16-1/6-2
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
The combination of the above thermoelements is referred to as type KX per ANSI MC 96.1.
EMF shall be 4.00 mV (minimum), 4.19 mV (maximum) as 100°C with reference junction at 0°C per ANSI MC96.1,
and shall be performed on every length of finished cable.
CHROMEL® and ALUMEL® are federally registered trademarks of Hoskins Manufacturing Company.
Alternative conductors, exhibiting the same performance characteristics, may be substituted for one
or both of the CHROMEL® and ALUMEL® conductors.
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
Page 1 of 1 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”.) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.