5-2.Electronic Characteristics
Characteristic Minimum Typical Maximum
Unit
Centre Frequency fC
(Centre frequency between 3dB points)
--
419.200
--
MHz
Insertion Loss
IL -- 3.0 4.5 dB
3dB Pass band BW3
±600 kHz
at fC -21.4MHz (Image) 30 38 --
at fC -10.7MHz (LO) 24 32 --
Rejection
Ultimate -- 60 --
dB
Turnover Temperature
TO
25 55 °C
Turnover Frequency fO
f
C
MHz
Temperature
Frequency Temperature Coefficient FTC
0.032
ppm/°C2
Frequency Aging - Absolute Value during the First Year |fA| 10 ppm/yr
iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling!
1. The frequency fC is defined as the midpoint between the 3dB frequencies.
2. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is
connected to a 50 Ω test system with VSWR ≤1.2:1. The test fixture L and C are adjusted for minimum insertion
loss at the filter centre frequency, fC. Note that insertion loss, bandwidth, and passband shape are dependent on
the impedance matching component values and quality.
3. Unless noted otherwise, specifications apply over the entire specified operating temperature range.
4. Frequency aging is the change in fC with time and is specified at +65°C or less. Aging may exceed the
specification for prolonged temperatures above +65°C. Typically, aging is greatest the first year after
manufacture, decreasing in subsequent years.
5. Turnover temperature, T0, is the temperature of maximum (or turnover) frequency, f0. The nominal frequency at
any case temperature, TC, may be calculated from: f = f0 [1 - FTC (T0 - TC)2].
6. The specifications of this device are based on the test circuit shown above and subject to change or
obsolescence without notice.
7. All equipment designs utilizing this product must be approved by the appropriate government agency prior to
manufacture or sale.
8. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications,
processes and circuits implemented within components or assemblies.
Issue : 1 C1
Date : SEPT 04