1
Guard Lock Safety-door Switch/D4SL-N-mounting Slide Key
D4SL-N
/
D4SL-NSK10-LK
@
World's smallest Class 6-contact Guard Lock
Safety-door Switch
<Guard Lock Safety-door Switch D4SL-N>
Wiring time is reduced with two types of wiring
methods capable of one-touch attachment and
removal.
A wide variety of built-in switches can be used for
various devices.
(4-, 5-, and 6-contact models are available)
Key holding force of 1,300 N.
It is possible to change the key insertion point
without detaching the head.
Drive solenoids directly from the Controller.
<Slide Key D4SL-NSK10-LK@>
Lockout Key to prevent workers from becoming
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch
can be easily mounted on 40 × 40 mm aluminum
frames.
The plastic material makes the Slide Key suitable
for lightweight doors.
Terminal
Block Type Connector Type
Guard Lock Safety-door Switch
Slide Key
Be sure to read the “Safety Precautions
on page 22.
Scan the 2D codes using the smartphone to see the D4SL-N promotional videos.
Reduction in time and effort Safe access application
D4SL-N / D4SL-NSK10-LK@
2
Model Number Structure
Model Number Legend
(1) Conduit Size
(2) Built-in Switch
(3) Head Material
(4) Door Lock and Release
(5) Indicator
(6) Release Key Type
(7) Connection Method
*1. M20, includes M20-to-1/2-14NPT conversion adapter.
*2. Connector cables are not included with the connector type and are to be purchased separately.
D4SL-N@@@@-@@@
(7)
Switch (Standard type)
(6)(5)(4)(3)(2)(1)
Contact Model Conduit Size
4-contact Model
5-contact Model
6-contact Model
2: G1/2
3: 1/2-14NPT *1
4: M20
Contact Model Built-in Switch
4-contact Model
Door monitor and Lock monitor are connected in series
internally.
A: 1NC/1NO + 1NC/1NO
B: 1NC/1NO + 2NC
C: 2NC + 1NC/1NO
D: 2NC + 2NC
Door monitor and Lock monitor are NOT connected in
series internally.
S: 1NC/1NO + 1NC/1NO
T: 1NC/1NO + 2NC
U: 2NC + 1NC/1NO
V: 2NC + 2NC
5-contact Model
E: 2NC/1NO + 1NC/1NO
F: 2NC/1NO + 2NC
G: 3NC + 1NC/1NO
H: 3NC + 2NC
6-contact Model
N: 2NC/1NO + 2NC/1NO
P: 2NC/1NO + 3NC
Q: 3NC + 2NC/1NO
R: 3NC + 3NC
Contact Model Head Material
4-contact Model F: Resin
5-contact Model
6-contact Model F: Resin
D: Metal
Common
Common
Contact Model Door Lock and Release
4-contact Model
5-contact Model
6-contact Model
A: Mechanical lock/24VDC solenoid release
G: 24VDC solenoid lock/mechanical release
Contact Model Indicator
4-contact Model : None
5-contact Model
6-contact Model D: 24VDC (orange LED indicator)
Contact Model Release Key Type
4-contact Model : Standard release key (metal)
5-contact Model
6-contact Model
: Standard release key (metal)
4: Special release key (resin)
(Note:Release keys are provided.)
Contact Model Connection Method
4-contact Model
5-contact Model
6-contact Model
: Terminal block
N: Connector *2
Common
Common
Common
Common
(2) Key Type
: No cushion rubber
G: Cushion rubber
S: No cushion rubber, short type
(1) Operation Key Type
1: Horizontal mounting
2: Vertical mounting
3: Adjustable mounting (horizontal)
5: Adjustable mounting (horizontal/vertical)
D4SL-NK@@
(1) (2)
Operation key
(1) Inner Lever
Blank: No inner lever
H: With inner lever
Slide key D4SL-NSK10-LK@-@
(1) (2)
(2) Lockout key Type
Lock out key can be created up to 30 types.
Specify keys in order starting from 01.
Blank: 01
02 to 30: 02 to 30
D4SL-N / D4SL-NSK10-LK@
3
Ordering Information
List of Models
Note: The recommended models for equipment and machinery being exported to Europe are those with an M20 conduit sizes, and for North
America, the recommended models are those with a 1/2-14NPT conduit sizes.
Release
Key Type Wiring
method
Solenoid voltage/
Indicator Lock and
release type
Contact configuration
(door open/closed detection switch
and lock monitor switch contacts)
Conduit
size
(See Note.) Model
Standard
(metal)
Connector
24VDC
(Orange)
Mechanical lock
Solenoid release
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FA-DN
1/2-14NPT D4SL-N3@FA-DN
M20 D4SL-N4@FA-DN
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FA-DN
1/2-14NPT D4SL-N3@FA-DN
M20 D4SL-N4@FA-DN
24VDC
(without indicator)
4-contact Model
Insert the built-in switch (A, B, C, D, S,
T, U or V) into the blank @.
G1/2 D4SL-N2@FA-N
1/2-14NPT D4SL-N3@FA-N
M20 D4SL-N4@FA-N
Terminal
block
24VDC
(Orange)
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FA-D
1/2-14NPT D4SL-N3@FA-D
M20 D4SL-N4@FA-D
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FA-D
1/2-14NPT D4SL-N3@FA-D
M20 D4SL-N4@FA-D
24VDC
(without indicator)
4-contact Model
Insert the built-in switch (A, B, C, D, S,
T, U or V) into the blank @.
G1/2 D4SL-N2@FA
1/2-14NPT D4SL-N3@FA
M20 D4SL-N4@FA
Connector
24VDC
(Orange)
Solenoid lock
Mechanical
release
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FG-DN
1/2-14NPT D4SL-N3@FG-DN
M20 D4SL-N4@FG-DN
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FG-DN
1/2-14NPT D4SL-N3@FG-DN
M20 D4SL-N4@FG-DN
24VDC
(without indicator)
4-contact Model
Insert the built-in switch (A, B, C, D, S,
T, U or V) into the blank @.
G1/2 D4SL-N2@FG-N
1/2-14NPT D4SL-N3@FG-N
M20 D4SL-N4@FG-N
Terminal
block
24VDC
(Orange)
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FG-D
1/2-14NPT D4SL-N3@FG-D
M20 D4SL-N4@FG-D
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FG-D
1/2-14NPT D4SL-N3@FG-D
M20 D4SL-N4@FG-D
24VDC
(without indicator)
4-contact Model
Insert the built-in switch (A, B, C, D, S,
T, U or V) into the blank @.
G1/2 D4SL-N2@FG
1/2-14NPT D4SL-N3@FG
M20 D4SL-N4@FG
D4SL-N / D4SL-NSK10-LK@
4
Note: The recommended models for equipment and machinery being exported to Europe are those with an M20 conduit sizes, and for North
America, the recommended models are those with a 1/2-14NPT conduit sizes.
Release
Key Type Wiring
method
Solenoid voltage/
Indicator Lock and
release type
Contact configuration
(door open/closed detection switch
and lock monitor switch contacts)
Conduit size
(See Note.) Model
Special
(resin)
Connector
24VDC
(Orange)
Mechanical lock
Solenoid release
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FA-D4N
1/2-14NPT D4SL-N3@FA-D4N
M20 D4SL-N4@FA-D4N
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FA-D4N
1/2-14NPT D4SL-N3@FA-D4N
M20 D4SL-N4@FA-D4N
Terminal
block
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FA-D4
1/2-14NPT D4SL-N3@FA-D4
M20 D4SL-N4@FA-D4
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FA-D4
1/2-14NPT D4SL-N3@FA-D4
M20 D4SL-N4@FA-D4
Connector
Solenoid lock
Mechanical
release
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FG-D4N
1/2-14NPT D4SL-N3@FG-D4N
M20 D4SL-N4@FG-D4N
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FG-D4N
1/2-14NPT D4SL-N3@FG-D4N
M20 D4SL-N4@FG-D4N
Terminal
block
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FG-D4
1/2-14NPT D4SL-N3@FG-D4
M20 D4SL-N4@FG-D4
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FG-D4
1/2-14NPT D4SL-N3@FG-D4
M20 D4SL-N4@FG-D4
D4SL-N / D4SL-NSK10-LK@
5
Operation Keys
Connector Cables
Type Model
Horizontal mounting D4SL-NK1
Horizontal mounting
(Short) D4SL-NK1S
Horizontal mounting
(Cushion rubber) D4SL-NK1G
Vertical mounting D4SL-NK2
Vertical mounting
(Cushion rubber) D4SL-NK2G
Adjustable
(Horizontal) D4SL-NK3
Adjustable
(Horizontal/Vertical) D4SL-NK5
Cable length Model
1 m D4SL-CN1
3 m D4SL-CN3
5 m D4SL-CN5
10 m D4SL-CN10
D4SL-N / D4SL-NSK10-LK@
6
Slide Key
Note: 1. The Door Switch is not included. Select the Door Switch depending on the necessary number of contacts and the conduit size.
The contents are provided as a total set, individual contents cannot be ordered separately.
2. Perform risk assessment for the equipment in question, configure relay units and other safety circuits, and use properly.
*1. The number for the lockout key is 01.
*2. Replace the box with 02 to 30 (lockout key number). Ask your OMRON representative for delivery times.
*3. The inner lever for D4SL-NSK10 that can not be used for other products and applications.
Applicable Door Switches
D4SL-NSK10-LK
D4SL-NSK10-LKH
Type Specifications Contents Model Applicable
Door Switch
Weight: Approx. 0.6 kg
Mechanical durability:
20,000 operations min.
Slide Key: 1 (not yet mounted)
Inner Lever: None
D4SL-N mounting plate: 1
Door Switch special mounting screws: 3
D4SL-NK1 (operation key): 1
D4SL-NK1 special mounting screws: 2
Lockout keys: 2
Lockout key strap: 1
Caution labels (stickers): 2 sheets
(English and Japanese)
D4SL-NSK10-LK *1
D4SL-N
D4SL-NSK10-LK-@ *2
Weight: Approx. 0.1 kg Inner Lever: 1 D4SL-SK10H *3 ---
Weight: Approx. 0.7 kg
Mechanical durability:
20,000 operations min.
Slide Key: 1 (not yet mounted)
Inner Lever: 1
D4SL-N mounting plate: 1
Door Switch special mounting screws: 3
D4SL-NK1 (operation key): 1
D4SL-NK1 special mounting screws: 2
Lockout keys: 2
Lockout key strap: 1
Caution labels (stickers): 2 sheets
(English and Japanese)
D4SL-NSK10-LKH *1
D4SL-N
D4SL-NSK10-LKH-@ *2
+=
D4SL-ND4SL-NSK10-LK
+=
D4SL-ND4SL-NSK10-LKH
D4SL-N / D4SL-NSK10-LK@
7
Features
The lockout key prevents workers from becoming trapped without using a padlock.
Note: Using LEDs of D4SL-N enables confirming whether the door is open or closed and locked or unlocked.
D4SL-N / D4SL-NSK10-LK@
8
Structure and Nomenclature
Structure
Can be mounted
from four directions.
Two operation key holes
The switch has
a release key
on the back of
the switch as well.
The switch has an
indicator on the back
of the switch as well.
Can be mounted
from four directions.
Two operation key holes
The switch has
a release key
on the back of
the switch as well.
The switch has an
indicator on the back
of the switch as well.
4.5 dia. * 4.5 dia. *
E1 (+)
E2 ()
11
21
33
9
10
41
51
63
42
52
64
<LED>
ORANGE
1
2
3
4
5
67
8
12
22
34
for D4SL-N@N@@-D@
Note: Numbers inside the boxes are terminal
numbers printed on the product.
D4SL-@@@@-D@ Terminal Block TypeD4SL-N@@@@-D@N Connector Type
4 5 6 10321
Notched side is No. 1
13 579
106428
4.5 dia. *
4.5 dia. *
Connector/Terminal
Terminal Arrengement
* You can insert and secure a stud or
other projection in the 4.5-dia. hole to
make the installation even stronger.
For details, refer to “Switch and
Operation Key Mounting” on page 24.
D4SL-N / D4SL-NSK10-LK@
9
Operating Cycle Examples for Standard Models
D4SL-N@@@A-@ (Mechanical Lock Models)
D4SL-N@@@G-@ (Solenoid Lock Models)
Door open/closed detection and lock monitor contacts: Can be used in safety circuits because of the direct opening mechanisms.
Door open/closed detection contact: Can be used to confirm whether the key is inserted and to monitor the open/closed status of a door.
Lock monitor contact: Can be used to confirm whether power is supplied to the solenoid and to monitor whether or not a door can be opened or closed.
Note: 1. The door open/closed detection and lock monitor contact configuration depends on the model.
2. If a current is detected in the solenoid lock model, before the door is closed, the door will remain unlocked.
Be sure to supply power to the solenoid after the door is closed.
Door condition Condition 1 Condition 2 Condition 3 Turning the special
release key
Terminal No. and
Contact No. Function
Door open.
The door will lock
when the door closes.
Door closed.
The door is locked.
Door closed.
The door can be
opened.
Door closed.
No power is supplied
to the solenoid.
The door is unlocked
manually.
Solenoid ON
Door open/closed detection
and lock monitor contacts
Door open/closed detection
contact
Door open/closed detection
contact
Lock monitor contact
Lock monitor contact
Door condition Even when the door
is closed, it does not
lock until power is
supplied to the
solenoid.
Door closed.
The door is locked.
Door closed.
The door can be
opened.Terminal No. and
Contact No. Function
Solenoid ON
Door open/closed detection
and lock monitor contacts
Door open/closed detection
contact
Door open/closed detection
contact
Lock monitor contact
Lock monitor contact
Return to
condition 1
E1- 10 E2
9
42- 111 (NC)
2
52- 321 (NC)
4
21- 422 (NC)
3
31- 632 (NC)
5
33- 634 (NO)
5
41- 242 (NC)
1
61- 862 (NC)
7
63- 864 (NO)
7
The shaded areas indicate
the contact is closed and
power is supplied to the
solenoid.
E1- 10 E2
9
42- 111 (NC)
2
52- 321 (NC)
4
21- 422 (NC)
3
31- 632 (NC)
5
33- 634 (NO)
5
41- 242 (NC)
1
61- 862 (NC)
7
63- 864 (NO)
7
D4SL-N / D4SL-NSK10-LK@
10
Specifications
Standards and EC Directives
Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EMC Directive
EN ISO 14119
EN60204-1
GS-ET-19
Certified Standards
*1. Certification has been obtained for UL CSA C22.2 No. 14.
*2. Only certain models have been certified.
Certified Standard Ratings
TÜV (EN60947-5-1) CCC (GB14048.5)
Note: Use a 4 A fuse that conforms to IEC60127 as a short-circuit protection device. This fuse is not included with the switch.
*1. 11-42, 21-52, 21-22
*2. Other terminals
UL/CSA (UL508, CSA C22.2 No.14)
C150
R150
Solenoid Coil Characteristics
* A starting current is applied to the solenoid for Approx. 10 seconds.
After this, the internal circuit switches to a constant current.
Indicator
Certification body Standard File No.
TÜV SÜD EN60947-5-1 (certified direct opening) Consult your OMRON representative for details.
UL *1 UL508, CSA C22.2 No.14 E76675
CQC (CCC) GB14048.5 2012010305582059
KOSHA *2 EN60947-5-1 Consult your OMRON representative for details.
Utilization category AC-15 DC-13
Rated operating current (Ie) 1.5 A *1
1 A *2 0.22 A
Rated operating voltage (Ue) 120 V 125 V
Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC 2.5 A 15 1.5 1,800 180
Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
125 VDC 1.0 A 0.22 0.22 2828
Item 24 VDC
Rated operating voltage (100% ED) 24 VDC
Current consumption *
Power ON:
6-contact type Approx. 6.4 W at 0.26 A
4-contact/5-contact type Approx. 4.8 W at 0.2 A
Constant: Approx. 2.6 W (average) at 0.2 A (max.)
Insulation Class E (to 120°C)
Item LED type
Rated voltage 24 VDC
Current consumption Approx.10 mA
Color (LED) Orange
+10%
15%
D4SL-N / D4SL-NSK10-LK@
11
Characteristics
Note: 1. The above values are initial values.
2. The Switch contacts can be used with either standard loads or microloads.
Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads.
The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1).
Confirm that sealing properties are sufficient for the operating conditions and environment beforehand.
Although the switch box is protected from dust, oil or water penetration, do not use the D4SL in places where cutting chips, oil, water or
chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON
representative.
*3. Do not pass the 1 A, 125 VAC load through more than 3 circuits.
*4. These figures are minimum requirements for safe operation.
*5. This figure is based on the GS-ET-19 evaluation method.
*6. This value will vary with the switching frequency, environment, and reliability level.
Confirm that correct operation is possible with the actual load beforehand.
Degree of protection *1 IP67 (EN60947-5-1)
Durability *2 Mechanical 1,000,000 operations min.
Electrical 150,000 operations min. (1 A resistance at 125 VAC) *3
Operating speed 0.05 to 1 m/s
Operating frequency 4- and 5-contact Model: 30 operations minute max.
6-contact Model: 5 operations minute max.
Direct opening force *4 60 N min. (EN60947-5-1)
Direct opening travel *4 15 mm min. (EN60947-5-1)
Holding force *5 1,300 N min.
Contact resistance 200 mΩ max.
Minimum applicable load *6 1 mA resistive load at 5 VDC (N-level reference value)
Rated insulation voltage (Ui) 150 V (EN60947-5-1)
Rated frequency 50/60 Hz
Protection against electric shock Class II (double insulation)
Pollution degree (operating environment) 3 (EN60947-5-1)
Impulse
withstand voltage
(EN60947-5-1)
Between terminals of same polarity 1.5 kV
Between terminals of different polarity 1.5 kV
Between other terminals and
non-current carrying metallic parts 2.5 kV
Insulation resistance 100 Ω min. (at 500 VDC)
Vibration resistance Malfunction 10 to 55 Hz, 0.35 mm single amplitude
Shock resistance Malfunction 80 m/s2 min.
Destruction 1,000 m/s2 min.
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional free air thermal current (Ith) 2.5A (11-42, 21-52, 21-22)
1A (Others)
Ambient operating temperature 10 to 55°C (with no icing)
Ambient operations humidity 95% max.
Weight
Head: Resin
Approx. 290 g (Connector model)
Approx. 330 g (Terminal block model)
Head: Metal
Approx. 370 g (Connector model)
Approx. 410 g (Terminal block model)
D4SL-N / D4SL-NSK10-LK@
12
Connection
Internal Circuit Diagram
Without indicator With indicator
Note: The numbers in boxes are the terminal numbers given on the Switch.
Circuit Connection Example
Direct opening contacts used as safety-circuit input are indicated with the mark.
Do not switch circuits for three or more standard loads at the same time.
Doing so may adversely affect insulation performance.
DC solenoids have polarity. (E1: Positive, E2: Negative)
Confirm terminal polarity before wiring.
If a lock is required for safety, design the system so that the closing of the NC contacts on both the door open/closed detection switch and the
lock monitor switch is detected.
Connection Example for D4SL-N@AF@-@
Contacts 12 and 41 are internally connected.
Connection Example for D4SL-N@EF@-D@
Contacts 12 and 41 are internally connected.
Connection Example for D4SL-N@SF@-@
There is no internal connection, so connect contacts 22 and 42 or 21
and 42 externally.
Connection Example for D4SL-N@NF@-D@
Contacts 12 and 41 and contacts 22 and 51 are internally connected.
D
D24VDC
E1 (+)
E2 ()
Z
D
Control
circuit
9
10
D
D24VDC
R
LED
E1 (+)
E2 ()
ZDControl
circuit
9
10
E1
(+)
E2
()
To control circuit
11
33
Lock monitor
switch
9
10
41
63
42
64
1
2
3
4
5
67
8
12
34 To control circuit
To safety circuit
(Not use)(Not use)
Door open/
closed detection
switch
E1
(+)
E2
()
To safety circuit
To control circuit
11
21
33
Lock monitor
switch
9
10
LED
41
63
42
22
64
1
2
3
4
5
67
8
12
34 To control circuit
To safety circuit
Door open/
closed detection
switch
E1
(+)
E2
()
To control circuit
21
41
33
Lock monitor
switch
9
10
63
42
22
64
1
2
3
4
5
67
834 To control circuit
To safety circuit
To safety circuit
Shortcircuit
Door open/
closed detection
switch
E1
(+)
E2
()
To safety circuit
To control circuit
11
21
33
Lock monitor
switch
9
10
LED
41
51
63
42
52
64
1
2
3
4
5
67
8
12
22
34 To control circuit
To safety circuit
Door open/
closed detection
switch
D4SL-N / D4SL-NSK10-LK@
13
Contact Form
Indicates conditions where the Key is inserted and the lock is applied.
Model
Contact
(door open/
closed detection
and lock monitor)
Contact Form
Operating pattern Remarks
Lock
monitor
Door open/
closed
detection
D4SL-N@A@@-@1NC/1NO+
1NC/1NO
Only NC contact 11-12 has a
certified direct opening
mechanism.
The terminals 42-11, 34-33, and
64-63 can be used as unlike
poles.
D4SL-N@B@@-@1NC/1NO+2NC
Only NC contact 11-12 has a
certified direct opening
mechanism.
The terminals 42-11, 34-33, and
62-61 can be used as unlike
poles.
D4SL-N@C@@-@2NC+1NC/1NO
Only NC contact 11-12 and 31-
32 has a certified direct opening
mechanism.
The terminals 42-11, 32-31, and
64-63 can be used as unlike
poles.
D4SL-N@D@@-@2NC+2NC
Only NC contact 11-12 and 31-
32 has a certified direct opening
mechanism.
The terminals 42-11, 32-31, and
62-61 can be used as unlike
poles.
D4SL-N@S@@-@1NC/1NO+
1NC/1NO
Only NC contact 21-22 has a
certified direct opening
mechanism.
The terminals 42-41, 22-21, 34-
33, and 64-63 can be used as
unlike poles.
D4SL-N@T@@-@1NC/1NO+2NC
Only NC contact 21-22 has a
certified direct opening
mechanism.
The terminals 42-41, 22-21, 34-
33, and 62-61 can be used as
unlike poles.
D4SL-N@U@@-@2NC+1NC/1NO
Only NC contact 21-22 and 31-
32 has a certified direct opening
mechanism.
The terminals 42-41, 22-21, 32-
31, and 64-63 can be used as
unlike poles.
D4SL-N@V@@-@2NC+2NC
Only NC contact 21-22 and 31-
32 has a certified direct opening
mechanism.
The terminals 42-41, 22-21, 32-
31, and 62-61 can be used as
unlike poles.
42
64 63
41 12
Door open/closed
detection
Lock monitor
11
34 33
2
8
1
5
7 6
On
Stroke
42-11
34-33
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
62 61
41 12 11
34 33
Door open/closed
detection
Lock monitor
2
8
1
5
7 6
On
Stroke
42-11
34-33
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
64 63
41 12 11
32 31
Door open/closed
detection
Lock monitor
2
8
1
5
7 6
On
Stroke
42-11
32-31
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
62 61
41 12 11
3132
Door open/closed
detection
Lock monitor
2
8
1
5
7 6
On
Stroke
42-11
32-31
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
64 63
41
34 33
2122
Door open/closed
detection
Lock monitor
2
8
3
4
1
5
7 6
On
Stroke
42-41
22-21
34-33
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
62 61
41
34 33
2122
Door open/closed
detection
Lock monitor
2
8
3
4
1
5
7 6
On
Stroke
42-41
22-21
34-33
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
64 63
41
32 31
2122
Door open/closed
detection
Lock monitor
2
8
3
4
1
5
7 6
On
Stroke
42-41
22-21
32-31
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
62 61
41
32 31
2122
Door open/closed
detection
Lock monitor
2
8
3
4
1
5
7 6
On
Stroke
42-41
22-21
32-31
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
D4SL-N / D4SL-NSK10-LK@
14
Model
Contact
(door open/
closed detection
and lock monitor)
Contact Form
Operating pattern Remarks
Lock
monitor
Door open/
closed
detection
D4SL-N@E@@-@2NC/1NO+
1NC/1NO
Only NC contact 11-12 and 21-
22 has a certified direct opening
mechanism.
The terminals 42-11, 22-21, 34-
33, and 64-63 can be used as
unlike poles.
D4SL-N@F@@-@2NC/1NO+2NC
Only NC contact 11-12 and 21-
22 has a certified direct opening
mechanism.
The terminals 42-11, 22-21, 34-
33, and 62-61 can be used as
unlike poles.
D4SL-N@G@@-@3NC+1NC/1NO
Only NC contact 11-12 ,21-22
and 31-32 has a certified direct
opening mechanism.
The terminals 42-11, 22-21, 32-
31, and 64-63 can be used as
unlike poles.
D4SL-N@H@@-@3NC+2NC
Only NC contact 11-12 ,21-22
and 31-32 has a certified direct
opening mechanism.
The terminals 42-11, 22-21, 32-
31, and 62-61 can be used as
unlike poles.
D4SL-N@N@@-@2NC/1NO+
2NC/1NO
Only NC contact 11-12 and 21-
22 has a certified direct opening
mechanism.
The terminals 42-11, 52-21, 34-
33, and 64-63 can be used as
unlike poles.
D4SL-N@P@@-@2NC/1NO+3NC
Only NC contact 11-12 and 21-
22 has a certified direct opening
mechanism.
The terminals 42-11, 52-21, 34-
33, and 62-61 can be used as
unlike poles.
D4SL-N@Q@@-@3NC+2NC/1NO
Only NC contact 11-12 ,21-22
and 31-32 has a certified direct
opening mechanism.
The terminals 42-11, 52-21, 32-
31, and 64-63 can be used as
unlike poles.
D4SL-N@R@@-@3NC+3NC
Only NC contact 11-12 ,21-22
and 31-32 has a certified direct
opening mechanism.
The terminals 42-11, 52-21, 32-
31, and 62-61 can be used as
unlike poles.
42
64 63
41 12 11
34 33
2122
Door open/closed
detection
Lock monitor
2
8
3
1
4
5
7 6
On
Stroke
42-11
22-21
34-33
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
62 61
41 12 11
34 33
2122
Door open/closed
detection
Lock monitor
2
8
3
1
4
5
7 6
On
Stroke
42-11
22-21
34-33
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
64 63
41 12 11
32 31
2122
Door open/closed
detection
Lock monitor
2
8
3
1
4
5
7 6
On
Stroke
42-11
22-21
32-31
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
62 61
41 12 11
2122
3132
Door open/closed
detection
Lock monitor
2
8
3
1
4
5
7 6
On
Stroke
42-11
32-31
22-21
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
52 51
64 63
41 12
Door open/closed
detection
Lock monitor
11
34 33
2122
2
8
43
1
5
7 6
On
Stroke
42-11
52-21
34-33
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
52 51
62 61
41 12 11
34 33
2122
Door open/closed
detection
Lock monitor
2
8
43
1
5
7 6
On
Stroke
42-11
52-21
34-33
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
52 51
64 63
41 12 11
32 31
2122
Door open/closed
detection
Lock monitor
2
8
43
1
5
7 6
On
Stroke
42-11
52-21
32-31
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
52 51
62 61
41 12 11
2122
3132
Door open/closed
detection
Lock monitor
2
8
43
1
5
7 6
On
Stroke
42-11
52-21
32-31
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
D4SL-N / D4SL-NSK10-LK@
15
Dimensions and Operating Characteristics (Unit:mm)
Switches
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
22
±0.2
4
(10.85
)(8)
(1)
26 dia.
A
Release key
4.5 dia. *
(depth: 1.6)
Front-side mounting
Two, 4.3 dia.
Mounting hole
LED indicators
22
±0.2
10
B
Label
4.5 dia. *
(depth: 1.6)
Side mounting
Three, 4.3 dia.
Mounting hole
29.2
29.2
Pre-travel distance
9
Head cap
Operation Key
One, Conduit
Conduit cap
Two, Cover mounting screw
26.3
(10.85)
B-B A-A
Release key
4.5 dia. *
(depth: 1.6)
LED indicators
26.3
4.5 dia. *
(depth: 1.6)
Spacers
41.7
±0.2
(62.75)
(73.5)
A
41.7
±0.2
(155)
41.7
±0.2
39
112.1
±0.8
(73.5)
31.5 42.9
(62.75)
B
39
38.7
±0.2
37
41.7
±0.2
38.5
D4SL-N@@@@-@N (Connector Type)
Model
Operating characteristics D4SL-N@@@@-@N
Key insertion force
Key extraction force
15 N max.
30 N max.
Pre-travel distance 15 mm max.
Movement before being locked 3 mm min.
* You can insert and secure a stud or
other projection in the 4.5-dia. hole to
make the installation even stronger.
For details, refer to “Switch and
Operation Key Mounting” on page 24.
Operation Key
B-B A-A
22
±0.2
4
(10.85
)
26 dia.
(1) (8)
4.5 dia. *
(depth: 1.6)
22
±0.2
10
29.2
29.2
Pre-travel distance
9
26.3
(10.85)
26.3
Release key
Spacers
Front-side mounting
Two, 4.3 dia.
Mounting hole
B
B
4.5 dia. *
(depth: 1.6)
LED indicators
4.5 dia. *
(depth: 1.6)
Release key
Side mounting
Three, 4.3 dia.
Mounting hole
4.5 dia. *
(depth: 1.6)
39
37
41.7
±0.2
38.5
38.7
±0.2
LED indicators
41.7
±0.2
Head cap
One, Conduit
Conduit cap
Two, Cover mounting screw
(179.9)
41.7
±0.2
A
A
137
±0.8
(73.5)
31.5 42.9
(62.75)
39
41.7
±0.2
(62.75)
(73.5)
D4SL-N@@@@-@ (Terminal Block Type)
Model
Operating characteristics D4SL-N@@@@-@
Key insertion force
Key extraction force
15 N max.
30 N max.
Pre-travel distance 15 mm max.
Movement before being locked 3 mm min.
* You can insert and secure a stud or
other projection in the 4.5-dia. hole to
make the installation even stronger.
For details, refer to “Switch and
Operation Key Mounting” on page 24.
D4SL-N / D4SL-NSK10-LK@
16
Operation key
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
22.7
2
21.5
7
74.3 Four, R2.15
35 15
2928
D4SL-NK1
22.7
2
19.5
13
Four, R2.15
7
74.3
35 15
29
D4SL-NK1S
22.7
Two, 9 dia.Two, 4.3 dia.
Mounting rubber 2
21.5
35 20
(5.2)
12
2928
D4SL-NK1G
22.7
2
15.6
Four, R2.15
35
7
7
14.5
4.3
8
15
29
D4SL-NK2
22.7
17.2
35
2
14.5
8
Two, 9 dia.
Two, 4.3 dia.
Mounting rubber
20
12
29
D4SL-NK2G
29
22.7 30
15
4.5 dia.
8 dia.
9 dia. 40
Angle adjustment bolt
56
20°
17.7
4
D4SL-NK3
15°
4
22.7
21.4 29
18° 18
4.5
15
17
22.5
24.4
41
6.5 (7)
41
5530 43 8
43
Angle adjustment bolt
Mounting Holes
(Enlargement)
D4SL-NK5
D4SL-N / D4SL-NSK10-LK@
17
Connector Cables
Slide Key
D4SL-NSK10-LK
8 dia.
Connector
Cable
AWG22, 10 conductors
*
* All 10 lead wires laid bare.
(Cross section of conductor: 0.3mm2 /Insulator diameter: 1.45mm)
Connector pin No.
10
9
8
7
6
5
4
3
2
1
(30) L ±40 (150)
(5)
D4SL-CN@
Model L size
D4SL-CN1 1 m
D4SL-CN3 3 m
D4SL-CN5 5 m
D4SL-CN10 10 m
Connector No. Lead wire color Connector No. Lead wire color
1 Black 6 Green/White
2 Black/White 7 Yellow
3Red 8Yellow/White
4 Red/White 9 Brown
5 Green 10 Brown/White
SLIDE
LOCK
SLIDE
FREE
SLIDE
LOCK
SLIDE
FREE
40×40
107
(147)
50 (64)
17
11.5
17
11.5
Four, M6
mounting holes
D4SL-NK1S
Operation Key
Guard Lock Safety-door Switch
D4SL-N
Three, M4
Two, M6
mounting holes
(32.5)
38.7
(35)
(26.8)
(35)
(20)
(56.5)
(76.2)
(330)
(314)
12.5
10
(112)
(232.2) (81.8)
(30.2)
(90.4)
(19.5)
(71.8)
19.1
8
Slide base
Shot bolt
Lockout key
Open door Close door
Guide
Switch base
A
A
B
B
12.5
22
20
11.6
4
4
Cross-sectional view B-B
Cross-sectional view A-A
(Between Slide Key)
15
+10
5
D4SL-N / D4SL-NSK10-LK@
18
D4SL-NSK10-LKH
Operation key Mounting
SLIDE
LOCK
SLIDE
FREE
SLIDE
LOCK
SLIDE
FREE
Slide base
D4SL-NK1S
Operation Key
Guard Lock Safety-door Switch
D4SL-N@@@@-@@N
Guard Lock Safety-door Switch
D4SL-N@@@@-@@
Two, M6
mounting holes
(323)
Aluminum frame
40×40
12.5
10
(147)
(35) (121)
50 (64)
90.4
(19.5)
19.1
8
Four, M6
mounting holes
Shot bolt
Lockout key
Three, M4
Guide Inner Lever
Switch base
B
12.5
22
20
11.6
4
4
Cross-sectional view B-B
Cross-sectional view A-A
107
(35)
(20)
(Between Slide Key)
17
11.5
17
40
(26.8)
(39.2)
11.5
(32.5)
38.7
(56.5)
(76.2)
330
A
B
15+10
5
A
(81.8)
(71.8)
(115)
(78)
40 dia.
12 dia.
(241.2)
Open door Close door
59 min.
61.5 max.
Key insertion
position
Vertical
insertion radius
R>
=
200
Center tolerance of
key hole: ±0.8
59 min.
61.5 max.
(15)
Key insertion
position
Horizontal
insertion radius
R>
=
180
Center tolerance of
key hole: ±0.8
(37)
(37)
31.5
D4SL-N+D4SL-NK1 With Front-inserted Operation Key With Top-inserted Operation Key
(15)
Horizontal
insertion radius
R>
=
180
60.5 min.
63 max.
Key insertion
position
Center tolerance of
key hole: ±0.8
9
Center tolerance of
key hole: ±0.8
60.5 min.
63 max.
Key insertion
position
Vertical
insertion radius
R>
=
200
(38.5)
(38.5)
D4SL-N / D4SL-NSK10-LK@
19
Vertical
insertion radius
R>
=
200
Center tolerance of
key hole: ±0.8
50.5 min.
53 max.
(15)
Key insertion
position
50.5 min.
53 max.
Key insertion
position
Horizontal
insertion radius
R>
=
180
Center tolerance of
key hole: ±0.8
31.5
(37)
(37)
(15)
Horizontal
insertion radius
R>
=
180
52 min.
54.5 max.
Key insertion
position
Center tolerance of
key hole: ±0.8
9
Center tolerance of
key hole: ±0.8
52 min.
54.5 max.
Key insertion
position
Vertical
insertion radius
R>
=
200
(38.5) (38.5)
D4SL-N+D4SL-NK1S
With Front-inserted Operation Key With Top-inserted Operation Key
Vertical
insertion radius
R>
=
140
Center tolerance of
key hole: ±0.8
59 min.
61.5 max.
Key insertion
position
59 min.
61.5max.
Key insertion
position
Horizontal
insertion radius
Pitch 12 mm R>
=
120
Pitch 20 mm R>
=
170
Center tolerance of
key hole: ±0.8
(Pitch 12 mm)
(Pitch 20 mm)
(37)
31.5
(28.9)
(37)
60.5 min.
63 max.
Key insertion
position
Center tolerance of
key hole: ±0.8
(Pitch 12 mm)
(Pitch 20 mm)
Horizontal
insertion radius
Pitch 12 mm R>
=
120
Pitch 20 mm R>
=
170
(6.4)
9
Center tolerance of
key hole: ±0.8
Vertical
insertion radius
R>
=
140
60.5 min.
63 max.
Key insertion
position
(38.5) (38.5)
D4SL-N+D4SL-NK1G With Front-inserted Operation Key With Top-inserted Operation Key
53.1 min.
55.6 max
Key insertion
position
Vertical
insertion radius
R>
=
200
Center tolerance of
key hole: ±0.8
53.1 min.
55.6 max.
(15)
Key insertion
position
Horizontal
insertion radius
R>
=
180
Center tolerance of
key hole: ±0.8
(37)
31.5 (39.5)
(37)
(38.5)
Horizontal
insertion radius
R>
=
180
54.6 min.
57.1 max.
Key insertion
position
Center tolerance of
key hole: ±0.8
9
Center tolerance of
key hole: ±0.8
54.6 min.
57.1 max.
Key insertion
position
Vertical
insertion radius
R>
=
200
(15) (17)
(38.5)
D4SL-N+D4SL-NK2 With Front-inserted Operation Key With Top-inserted Operation Key
D4SL-N / D4SL-NSK10-LK@
20
Vertical
insertion radius
R>
=
140
Center tolerance of
key hole: ±0.8
54.7 min.
57.2 max.
Key insertion
position
54.7 min.
57.2 max.
Key insertion
position
Horizontal
insertion radius
Pitch 12 mm R>
=
120
Pitch 20 mm R>
=
170
Center tolerance of
key hole: ±0.8
(Pitch 12 mm)
(Pitch 20 mm)
(37)
(37)
31.5 (39.5)
Center tolerance of
key hole: ±0.8
(Pitch 12 mm)
(Pitch 20 mm)
Horizontal
insertion radius
Pitch 12 mm R>
=
120
Pitch 20 mm R>
=
170
56.2 min.
58.7 max.
Key insertion
position
9
(21.5)
Center tolerance of
key hole: ±0.8
Vertical
insertion radius
R>
=
140
56.2 min.
58.7 max.
Key insertion
position
(38.5) (38.5)
D4SL-N+D4SL-NK2G With Front-inserted Operation Key With Top-inserted Operation Key
55.2 min.
57.7 max.
Key insertion
position
Vertical
insertion radius
R>
=
200
Center tolerance of
key hole: ±0.8
55.2 min.
57.7 max.
Key insertion
position
Horizontal
insertion radius
R>
=
50
Center tolerance of
key hole: ±0.8
(37)
(37)
(40
±0.15
)
31.5
Horizontal
insertion radius
R>
=
50
56.7 min.
59.2 max.
Key insertion
position
Center tolerance of
key hole: ±0.8
(40
±
0.15
)
(9)
Center tolerance of
key hole: ±0.8
Vertical
insertion radius
R>
=
200
56.7 min.
59.2 max.
Key insertion
position
(38.5) (38.5)
D4SL-N+D4SL-NK3 With Front-inserted Operation Key With Top-inserted Operation Key
21.4
55
31.5
58.7 min.
61.2 max.
Key insertion
position *
58.7 min.
61.2 max.
Key insertion
position *
Horizontal
insertion radius
R>
=
50
Vertical
insertion radius
R>
=
50
Center tolerance of
key hole: ±0.8
Center tolerance of
key hole: ±0.8
(37)
(41 or 43)
(37)
(9)
Center tolerance of
key hole: ±0.8
Vertical
insertion radius
R>
=
50
60.4 min.
62.9 max.
Key insertion
position
(38.5)
Horizontal
insertion radius
R>
=
50
60.4 min.
62.9 max.
Key insertion
position
Center tolerance of
key hole: ±0.8
(38.5)
(41 or 43)
D4SL-N+D4SL-NK5 With Front-inserted Operation Key With Top-inserted Operation Key
* If you use the D4SL-NK5 turned over, the key insertion position is 60.3 min. and 61.2 max.
D4SL-N / D4SL-NSK10-LK@
21
Application Example
D4SL-N Application Example
Application Overview
If the guard is opened, it is detected with S2 and the power supply to the motor (M) is shut OFF.
When the guard is closed, the lock status can be detected and the power supply to the motor (M) remains shut OFF until limit switch S3 is pressed.
PL/Safety Category Applied models Stop category Reset method
Equivalent to PLe/4
D4SL-N@R@A-@ Compact
Safety Door Switch with Magnetic Lock (mechanical lock)
G9SA-301 (24 VAC/DC)
Safety Relay Unit
0 Manual
Feedback loop
Stop signal
Guard
Lock release signal
TH
SA
A1 A2
T11 T12
K1
K1
PE
T21 T23 T22
K2
K2
6
a
b
1
2
3
4
5
6
JP
13
T32T31
23 33 41
2
5
3
1
K1
K2
4
a
b
Control
Circuit
14 24 34 42
AB
KM1
KM2
M
KM1 KM2
9
1 2 3 4 5 6 7 8
10
S2
OPEN
S4
KM1
KM2
42
41
12
11
S1
KM1
KM2
S3
to PLC
to PLC
K1 and K2 (NC)
K1 and K2 (NO)
KM1 and KM2 (NC)
KM1 and KM2 (NO)
Guard can be opened
Reset switch S3
Stop signal
Lock release signal
S4
Limit switch S1
Guard Lock
Safety-door Switch
S2
Guard opens
Note: 1. The above circuit diagram is for Category 4.
2. Numbers inside the boxes are terminal numbers printed on the
product.
S1: Safety Limit Switch with direct opening mechanism
(D4B-N, D4N or D4F)
S2: D4SL-N
S3: Reset switch
S4: Lock release switch
KM1 and KM2: Magnetic Contactor
M: 3-phase motor
Timing Chart
D4SL-N / D4SL-NSK10-LK@
22
Safety Precautions
Be sure to read the precautions for All Safety Door Switches in the website at:http://www.ia.omron.com/.
D4SL-N
D4SL-NSK10-LK@
D4SL-N
Operating Environment
Do not use the Switch submersed in oil or water or in locations
continuously subject to splashes of oil or water. Doing so may result
in oil or water entering the Switch. (The IP67 degree of protection of
the Switch specifies the amount of water penetration after the Switch
is submerged in water for a certain period of time.)
Wiring
Do not switch circuits for three or more standard loads (125 VAC,
1A). Doing so may adversely affect insulation performance.
Do not allow the load current to exceed the rated value.
For metal connector, use a connector with the screw length of 9
mm or less. Otherwise it may result in electric shock.
Do not use metallic conduits. In the event of damage to the conduit
opening, this may cause seal failure and may result in electric
shock.
Do not use a metal connector for a 1/2-14NPT connector. In the
event of damage to the conversion adapter, this may cause seal
failure and may result in electric shock.
Always attach the cover after completing wiring and before using
the Switch. Do not supply power when the cover is not attached.
Electric shock may occur if the Switch is used without the cover
attached.
When using the terminal block type, make sure that foreign
material does not adhere to the terminal block board. Otherwise a
short circuit may occur between terminals and safety functions
may fail to work properly.
Installation
Make sure the Switch is mounted securely to prevent it from falling
off. Otherwise injury may result.
Do not use a Switch as a stopper.
Be sure to install a stopper as shown in the
following illustration so that the Operation
Key does not touch the head.
Do not subject the Switch to a shock that
exceeds the Switch's shock resistance of
1,000 m/s2.
Indicates an imminently hazardous
situation which, if not avoided, is likely to
result in serious injury or may result in
death. Additionally there may be severe
property damage.
Indicates a potentially hazardous situation
which, if not avoided, may result in minor
or moderate injury or in property damage.
Precautions
for Safe Use
Supplementary comments on what to do
or avoid doing, to use the product safely.
Precautions
for Correct
Use
Supplementary comments on what to do
or avoid doing, to prevent failure to
operate, malfunction or undesirable effect
on product performance.
DANGER
Injury may occasionally occur. Always check to make
sure that the safety functions operate correctly before
using the machine. The safety functions may not
operate correctly because of wiring mistakes, setting
mistakes, or Switch malfunction, causing some
machines to continue operating in situations where
they should be stopped.
CAUTION
Injury may occasionally occur. When the Switch
function is damaged, some machines may continue
operating in situations where they should be stopped.
Do not impose a force exceeding the key holding
force.
Always provide a lock separate from the Switch,
attach a warning seal to avoid excessive force applied
to the Switch, or provide an indicator lamp to show the
locked/unlocked status of the door.
Do not use this product mounted so that it slides
vertically.
This may cause malfunction, resulting in personal
injury.
Do not insert the operation key with the door open.
Devices may start to operate, resulting in injury.
DANGER
CAUTION
Precautions for Safe Use
StopperHead
Operation Key
Switch
D4SL-N / D4SL-NSK10-LK@
23
D4SL-NSK10-LK@
Do not drop the Product. Doing so may prevent the Product from
functioning to full capacity.
Mount the Product securely to prevent it from falling. Otherwise,
injury may occur.
Do not attempt to disassemble or modify the Switch. Doing so may
cause the Switch to malfunction.
Make sure that the gap between the shot bolt and the guide is ±0.5
mm.
Otherwise, excessive wear or damage may cause malfunction.
To ensure safety, do not operate the Switch with anything other
than the Slide Key Unit.
Your hand may be injured by being pinched between the Operation
Key and Switch when closing the door with your hand on the
Product.
Be careful to avoid pinching your hand when operating the Slide
Handle.
Do not impose a force of exceeding 1 Nm when operating the
Lockout Key.
Otherwise, the Product may be damaged and may not operate
properly.
To prevent damage, attach the supplied labels for display near the
Product.
Do not force the slide handle to move when the lockout key is not
inserted. Doing so may damage the product and make operation
impossible.
Do not force the slide handle to move when the door is locked.
Doing so may damage the product and make operation impossible.
Do not close the door with the shot bolt removed. Doing so may
damage the product and make operation impossible.
Turn the Lockout Key to the "SLIDE LOCK" position and remove it
when opening the door to prevent a third party from operating the
Slide Handle.
The durability of the Switch varies considerably depending on the
switching conditions. Always confirm the usage conditions by using
the Switch in an actual application, and use the Switch only for the
number of switching operations given in the performance
specifications.
The user must not maintain or repair equipment incorporating the
Switch. Contact the manufacturer of the equipment for any
maintenance or repairs required.
Refer to the D4SL-N Guard Lock Safety-door Switch Instruction
Sheet about storage conditions, ambient conditions,
Switch details, and handling methods.
Do not apply excessive force in the direction of the slide. This may
damage the product and cause it to malfunction.
Do not force the switch or cable. This may
damage the product. The cable should be fixed at
a point separate from the switch.
D4SL-N
Solenoid Lock Models
Be sure to supply power to the solenoid after the door is closed
(after the Operation Key is inserted).
The solenoid lock locks the door only when power is supplied to the
solenoid. Therefore, the door will be unlocked if the power supply
to the solenoid stops. Therefore, do not use solenoid lock models
for machines that may be operating and dangerous even after the
machine stops operating.
Release Key
The release key is used to unlock the Switch in case of emergency
or if the power supply to the Switch stops.
If the release key setting is changed from LOCK to UNLOCK, the
lock will be released and the safety door can be opened
(mechanical lock models only).
Å@
When a Switch with a solenoid lock is in a locked state (i.e., when
the solenoid is ON), do not change the release key from the LOCK
to the UNLOCK position. Internal parts may be damaged.
After setting the release key to UNLOCK to, for example, perform
maintenance, be sure to return it to LOCK setting before resuming
operation.
The release key is set in the unlock position at the factory for the
D4SL-N@@@A and to the lock position for the D4SL-N@@@G.
In the unlock position, even when the door of large machines or
stamping machines is closed during preliminary adjustment, the
door will remain unlocked and the machines will not be activated.
Do not use the release key to start or stop machines.
The auxiliary lock must be released only by authorized personnel.
Do not impose a force exceeding 0.2 Nm on the release key
screws. The release key may be damaged and may not operate
properly.
To prevent the release key from being used by unauthorized
personnel, set it to LOCK and seal it with sealing wax.
SLIDE
LOCK
SLIDE
FREE
Precautions for Correct Use
UNLOCK
LOCK
UNLOCK
LOCK
LOCK
UNLOCK
LOCK
UNLOCK
D4SL-N@@@@-@D4SL-N@@@@-@4
Front
D4SL-N@@@@-@D4SL-N@@@@-@4
Back
D4SL-N / D4SL-NSK10-LK@
24
Mounting Covers
Confirm that the seal rubber has no defects before use. If the seal
rubber is displaced or raised, or has foreign particles adhered to it,
the sealing capability of the seal rubber will be adversely affected.
Hinged Door
If the Switch is mounted too close to the hinge, the force imposed
on the lock will be much larger than for locations far from the hinge
and the lock may be damaged. Mount the Switch close to the
handle.
Mounting
Appropriate Tightening Torque
Loose screws may result in malfunction. Tighten the screws to the
specified torques.
Switch and Operation Key Mounting
Mount the Switch and Operation Key securely to the applicable
tightening torque with M4 screws. Always use washers.
The switch can be fastened more firmly by a stud (4 mm dia., 1.5
mm max height) inserted from back side at the hole of the switch.
Do not impose excessive force on the key top while the operation
key is inserted into the switch body or drop the switch with the
operation key inserted to avoid the deformation of the key or the
breakage of the switch body.
Do not use the operation key other than dedicated OMRON's
(D4SL-NK@). Otherwise switch may be damaged.
Do not use the operation key D4SL-K@. A lock will not be closed
and a machine will not be activated.
Be sure that the operation key can be inserted properly to key hole
with a tolerance of ±0.8 mm.
Insert the operation key into the key hole according to the specified
“operation key insertion radius in horizontal direction”.
When mounting at the side of switch body, mount the switch with 3
points including the head.
Attach cap heads to any operation key holes that are not being
used.
Securing the Door
When the door is closed (with the
Operation Key inserted), the Operation
Key may exceed the set zone because
of, for example, the door's own weight,
machine vibration, or the door cushion
rubber.
Secure the door with a stopper (hook)
so that the Operation Key remains
within the set zone.
Spacer
Do not remove a spacer. Rotate the spacer in accordance with the
Switch mounting direction. Use of the Switch without spacer will
reduce the lock strength.
Wiring
Circuit Connection Example
Direct opening contacts used as safety-circuit inputs are indicated
with the mark.
DC solenoids have polarity. (E1: +, E2: ) Confirm terminal polarity
before wiring.
The current of the 24 VDC solenoid is different from when it is first
turned ON as to when it is in operation. To take into account
possible voltage drops, it is important to apply a rated operation
voltage.
To enable the 24 VDC solenoid, it is necessary to select the
appropriate power supply capacity.
The ON and OFF contact operation will not engage
simultaneously.
Be sure to confirm operation under actual operating conditions.
If a lock is required for safety, design the system so that the closing
of the NC contacts on both the door open/closed detection switch
and the lock monitor switch is detected.
(D4SL-N@N@@-D@)
Contacts 12 and 41 and contacts 22 and 51 are internally connected.
Note: The numbers in boxes are the terminal numbers given on the
Switch.
Cover mounting
screw 0.4 to 0.5 Nm
Operation Key
mounting screw
2.4 to 2.8 Nm (D4SL-NK@ and -NK@S)
0.75 to 1.15 Nm (D4SL-NK@G)
Switch mounting
screw 0.75 to 1.15 Nm
Connector 1.8 to 2.2 Nm (except 1/2-14NPT)
1.4 to 1.8 Nm (1/2-14NPT)
Terminal screw
* Terminal block type
only
0.5 to 0.6 Nm (D4SL-N@@@@-@@)
15±0.1
40±0.1
10±0.1
Two, M4
12±0.1 or 20±0.1
Two, M4
Two, M4
Two, M4
38.7±0.1 Three, M4
22±0.1
41.7±0.15
41.7±0.15
Front D4SL-NK1/-NK2
D4SL-NK1G/-NK2G
D4SL-NK3
Side
Two, M 4
Stud: 4±0.1 dia., height: 1.5 max.
Stud: 4±0.1 dia., height: 1.5 max.
22±0.1
D4SL-NK5
41±0.1 or 43±0.1
Switch mounting Operation Key mounting
Set zone *
(0.5 to 3 mm)
Operation key
* If you use the D4SL-NK5 with the
front key hole oriented in the
direction shown in the right diagram,
the set zone will be 2.1 to 3.0 mm.
Spacer
Mounting side
E1
(+)
E2
()
To safety circuit
To control circuit
11
21
33
Lock monitor
switch
9
10
LED
41
51
63
42
52
64
1
2
3
4
5
67
8
12
22
34 To control circuit
To safety circuit
Door open/
closed detection
switch
D4SL-N / D4SL-NSK10-LK@
25
(D4SL-N@SF@-@)
There is no internal connection, so connect contacts 22 and 42 or 21
and 42 externally.
Wiring Precautions for D4SL-N@@@@-@@
Do not wire the Switch while power is being supplied. Doing so may
result in electric shock.
Do not let particles, such as small pieces of lead wire, enter the
switch body when wiring.
Do not directly wire the stranded wire to the terminal block.
When connecting to the terminals via insulating tube and bar
terminals, arrange the bar terminals so that they do not rise up onto
the case or the cover.
Applicable lead wire size: AWG22 to AWG18 (0.3 to 0.75 mm2).
Use lead wires of an appropriate length. Not doing so may result in
excess length causing the cover to rise and not fit properly.
Remove the terminal block board out of the unit to perform wiring.
Be sure to insert the connector properly.
Do not pull on the lead wires with excessive force. Doing so may
disconnect them.
Recommended Crimp Terminals
Wiring Precautions for D4SL-N@@@@-@@N
Do not wire the Switch while power is being supplied. Doing so may
result in electric shock.
Do not let particles, such as small pieces of lead wire, enter the
switch body when wiring.
Applicable lead wire size: AWG24 to AWG22 (0.2 to 0.3 mm2).
Do not apply a current of 2 A or more when using AWG24.
Use lead wires of an appropriate length. Not doing so may result in
excess length causing the cover to rise and not fit properly.
Do not pull on the lead wires with excessive force. Doing so may
disconnect them.
Do not forcibly insert the wired socket at the cable side into the
connector or D4SL-N’s conduit opening. Doing so may cause
cable break.
Be sure to insert the cable into the connector or D4SL’s conduit
opening before performing wiring to the socket, or insert the cable
into the connector or conduit opening from the opposite side of the
socket.
Applicable socket for cable side
Processing the Conduit Opening
Connect a recommended connector to the opening of the conduit
and tighten the connector to the proper torque. The case may be
damaged if excessive tightening torque is applied.
Use the cable with the connector-specified outside diameter.
For the 1/2-14NPT conduit, mount a provided conversion adapter
to use the connector above.
Recommended Connectors
Use a connector with a screw section not exceeding 9 mm.
Otherwise the screws will protrude into the case interior.
The connectors given in the following table have connectors with
screw sections not exceeding 9 mm.
Use the following connectors to ensure conformance to IP67.
Use LAPP connectors together with Seal Packing (JPK-16 for G1/
2, or GPM20 for M20), and tighten to the applicable torque. Seal
Packing is sold separately.
LAPP is a German manufacturer.
Ace Service Co. is a Japanese manufacturer.
Manufacturer Model Applicable wire lead
PHOENIX
CONTACT
AI0.34-8 TQ AWG22
AI0.5-8 WH AWG20
AI0.75-8 GY AWG18
E1
(+)
E2
()
To control circuit
21
41
33
Lock monitor
switch
9
10
63
42
22
64
1
2
3
4
5
67
834 To control circuit
Door open/
closed detection
switch
To safety circuit
To safety circuit
Shortcircuit
30±3 mm
40±3 mm
1 3 5 7 9
2 4 6 8
10
13579
2468
10
L1
L2
L1: 14 mm max.
L2: 8 mm max.
1 2
10
30
±3
mm
45610321
Manufacturer Name Model
J.S.T. Mfg Co.
Housing XHP-10
Contact
(applicable wire lead:
AWG24 to AWG22) SXH-001T-P0.6
Size Manufacturer Model Applicable cable
diameter Remarks
G1/2 LAPP ST-PF1/2
5380-1002 6.0 to 12.0 mm
Ace Service Co. LS-2G 6.0 to 11.0 mm Short type
M20 LAPP ST-M20×1.5
5311-1020 7.0 to 13.0 mm
1/2-
14NPT LAPP ST-NPT1/2
5301-6030 6.0 to 12.0 mm
D4SL-N / D4SL-NSK10-LK@
26
D4SL-NSK10-LK@
Use this product for a lightweight door (20 kg max). Otherwise the
product may be damaged.
This product is for D4SL-N Guard Lock Safety-door Switch only.
This product cannot be used with any other manufacturer's door
switches.
Use the Slide Handle in the direction A or B in the following figure.
Loose screws may result in malfunction. Use washers and tighten
the screws to the specified torques. Mount the Slide Base at four
points with screws. Adding adhesive is recommended for
preventing the screws from loosening.
Also, when mounting the Product to a door for disable-prevention
purposes, purchase and use tamper-resistant screws.
Approriate Tightening Torque
Technical Specifications
Do not store the Switch where corrosive gases (e.g., H2S, SO2,
NH3, HNO3 or Cl2) or dust is present, or in locations subject to high
temperature or humidity.
Perform maintenance inspections periodically.
When the lockout key is attached to your wrist, be careful that the
strap does not get stuck in equipment.
Nomenclature
Differences between Lockout Key and Trapped Key
(Reference)
When mounting the operation key, line up the inside edges of the
long operation key holes with the outer edges of the slide handle
as in the following figure to ensure easy position adjustment.
Use the supplied special screws to mount the operation key and
D4SL-N Guard Lock Safety-door Switch.
To tighten the screws, use the tip of a flat-head screwdriver on the
screw heads as shown in the following figure.
The special screws cannot be removed once they are tightened.
Mounting of innner lever
Mounting method
1) Detaching of mounting screw
Remove the handle mounting screw with TORX screwdriver (T30).
2) Mounting of inner lever
Tighten A portion of the inner lever to a suitable torque with wrench
(width across flat: 10mm).
This product is for Omron, the D4SL-NSK10 only. This product
cannot be used with any other products.
Do not operate the handle with the handle mounting screw
removed. Doing so may result in malfunction.
Be careful not to lose the spring washer and hexagonal nut when
remove the handle mounting screw. (Fig.1)
Loose inner lever may result in malfunction. Use washers and
tighten the inner lever to the specified torque. (Fig.2)
Slide Key mounting screw (M6) 6.0 to 7.0 Nm
Operation key special mounting screw
(screws supplied) 2.4 to 2.8 Nm
Switch special mounting screw
(screws supplied) 0.75 to 1.15 Nm
Inner Lever 9 to 10 Nm
Ambient operating temperature 10 to 55°C (with no icing)
Ambient operating humidity 95% max.
Mechanical durability 20,000 operations min.
AB
SLIDE
LOCK
SLIDE
FREE
SLIDE
LOCK
SLIDE
FREE
Slide Key Unit
D4SL-N Guard Lock Safety-door Switch
Release Key
Operation Key
Lockout key Slide Handle
Slide Base
Shot Bolt
Guide
Lockout key
Trapped key
(Refer to information on the
D4JL-@@@A-@7-@@)
Closing
the door
The door cannot be closed
unless the lockout key is
inserted in the slide and
turned.
The door cannot be closed
unless the trapped key is
inserted in the Door Switch
and turned.
Opening
the door
The door can be opened by
supplying power to the Door
Switch solenoid without
operating the lockout switch.
The door can never be opened
without both supplying power
to the Door Switch solenoid
and operating the trapped key.
Note: The special screws are
designed so that they cannot
be turned counter-clockwise
using a flat-head
screwdriver.
Handle mounting screw
(TORX_T30/M6)
Spring washer
(M6) Fig.1
Hexagonal nut (M6)
Handle
Spring washer
(M6)
Fig.1
Tightening Torque
Inner lever
A
Inner lever (M6) 9 to 10 N.m
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
Authorized Distributor:
In the interest of product improvement,
specifications are subject to change without notice.
Cat. No. C146-E1-03
© OMRON Corporation 2012-2015 All Rights Reserved.
OMRON Corporation Industrial Automation Company
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Contact: www.ia.omron.com
Kyoto, JAPAN
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 1015 (0412)
CSM_7_1_1016