SR820S THRU SR8200S SCHOTTKY BARRIER RECTIFIER VOLTAGE RANGE 20 to 200 Volts CURRENT 8.0 Amperes FEATURES High reliability Low switching loss Low forward voltage drop High current capability High switching capability D2-PAK .173 (4.40) .053 (1.35) .049 (1.25) .036 (0.91) .028 (0.71) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 o C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. .083 (2.10) .055 (1.40) .047 (1.20) .098 (2.50) .069 (1.75) .110 (2.80) .126 (3.20) .189 (4.80) .576 (14.64) PIN2 PIN1 .624 (15.84) .346 (8.8) * Epoxy: Device has UL flammability classification 94V-O * Case: Molded plastic * Lead: MIL-STD-202E method 208C guaranteed * Mounting: position: Any * Weight: 1.35 grams .323 (8.2) .049 (1.25 REF.) MECHANICAL DATA .053 (1.35) * * * * * .202 (5.13) .020 (0.50) .198 (5.03) .412 (10.46) .012 (0.30) PIN 1 .388 (9.86) For capacitive load, derate current by 20%. HEATSINK PIN 2 Dimensions in inches and (millimeters) MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) SYMBOL RATINGS SR820S SR830S SR835S SR840S SR845S SR850S SR860S SR880S SR8100S SR8150S SR8200S UNITS Maximum Recurrent Peak Reverse Voltage VRRM 20 30 35 40 45 50 60 80 100 150 200 Maximum RMS Voltage VRMS 14 21 25 28 32 35 42 56 70 105 140 Volts VDC 20 30 35 40 45 50 60 80 100 150 200 Volts Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at Derating Case Temperature Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Thermal Resistance (Note 1) Volts IO 8.0 Amps I FSM 150 Amps RJA RJC 60 0 3 C/W Typical Junction Capacitance (Note 2) CJ Operating Temperature Range TJ 150 0 C T STG -55 to + 150 0 C Storage Temperature Range 700 pF 450 ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted) CHARACTERISTICS Maximum Instantaneous Forward Voltage at 8.0A DC Maximum Average Reverse Current @T A = 25 o C at Rated DC Blocking Voltage @T A = 100 o C SYMBOL SR820S SR830S SR835S SR840S SR845S SR850S SR860S SR880S SR8100S VF IR NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted. 2. Measured at 1 MHz and applied reverse voltage of 4.0 volts. 3. "Fully ROHS compliant", "100% Sn plating (Pb-free)". 4. Suffix "R" for Reverse Polarity. 5. Suffix "K" for D-PAK Pkg. .65 .75 0.2 2 SR8150S SR8200S .85 UNITS Volts mA mA 2013-06 REV: A 8 SR8 50S 6 0S 4 820 82 ~S R SR R8 0S ~S 45 2 0 S AVERAGE FORWARD CURRENT, (A) 10 Single Phase Half Wave 60Hz Inductive or Resistive Load 0 50 100 150 INSTANTANEOUS REVERSE CURRENT, (mA) RATING AND CHARACTERISTICS CURVES ( SR820S THRU SR8200S ) 100 10 TA = 100 OC 1.0 TA = 25 OC 0.1 0.01 SR820S ~SR840S SR850S~SR8200S 0 20 O CJ, JUNCTION CAPACITANCE, (pF) 50 SR820S ~SR845S 10 SR850S ~SR860S SR880S ~SR8200S 1.0 TJ = 25 C Pulse width=300S 1% Duty Cycle O 0.1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 40 60 0.8 100 120 140 0.9 1.0 FIG.2 TYPICAL REVERSE CHARACTERISTICS 4000 2000 SR820S ~SR845S 1000 800 600 400 SR850S ~SR8200S 200 100 0.4 0.1 INSTANTANEOUS FORWARD VOLTAGE, (V) 1.0 4 10 40 REVERSE VOLTAGE, (V) FIG.3 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS 155 FIG.4 TYPICAL JUNCTION CAPACITANCE 8.3mS Single Half Sine-Wave JEDEC Method 150 145 140 135 130 125 1 80 PERCENT OF RATED PEAK REVERSE VOLTAGE, (%) FIG.1 TYPICAL FORWARD CURRENT DERATING CURVE PEAK FORWARD SURGE CURRENT, (A) INSTANTANEOUS FORWARD CURRENT, (A) CASE TEMPERATURE, ( C) 2 5 10 20 50 100 NUMBER OF CYCLES AT 60Hz FIG.5 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT 80100 RECTRON Attachment information about SR8XXS 1. Internal Circuit 2. Marking on the body Plant - code Rectron Logo V Y W W S R 8 XX S Part No. Year - code (Y: Last digit of year & A:2010,B:2011.....) Week - code (WW:01~52) Voltage-code 20-----20V 30-----30V 35-----35V 40-----40V 45-----45V 50-----50V 60-----60V 80-----80V 100-----100V 150-----150V 200-----200V PACKAGING OF DIODE AND BRIDGE RECTIFIERS BULK PACK EA PER BOX INNER BOX SIZE CARTON SIZE (mm) (mm) EA PER CARTON GROSS WEIGHT(Kg) PACKAGE PACKING CODE A-405 -B 1,000 194*84*21 450*220*255 50,000 15.64 BR-3/-6 -B 200 206*208*55 450*220*255 1,600 6.00 / 6.80 BR-8/-10 -B 200 236*236*50 497*251*282 2,000 12.24 BR-15/-25/-35/(W) -B 50 203*205*57 450*220*255 400 12.50 (14.40) DO-15 -B 500 194*84*21 450*220*255 25,000 12.74 DO-201 -B 500 300*73*40 347*320*271 12,000 15.90 DO-41 -B 1,000 194*75*21 415*220*255 50,000 16.2 HVM -B 200 165*214*52 353*226*290 2,000 --- HVP -B 40 236*236*40 502*251*145 240 8.80 MB-15/-25/-35(W) -B 50 203*205*57 450*220*255 400 13.60 (14.30) MP-15/-25/-35(W) -B 50 203*205*57 450*220*255 400 7.7 (8.26) R-1/-3 -B 1000 / 500 194*84*21 450*220*255 50,000 / 25,000 11.74 / 16.17 R-6 -B 200 300*73*40 347*320*271 4,800 12.93 RB-15 -B 1,000 165*252*59 347*320*271 10,000 11.6 RBU -B 450 240*239*35 502*251*126 2,700 13.00 RC-2 -B 600 165*252*59 347*320*271 6,000 9.4 RS-1 -B 600 240*239*35 497*255*162 4,800 9.264 RS-2L -B 400 213*162*52 450*220*255 4,000 13.65 RS-4L -B 300 230*162*52 502*251*126 1,800 11.3 RS-6/-8 -B 200 236*236*34 497*255*162 1,600 13.6 / 14.5 RS-2M -B 600 236*236*40 492*255*167 3,600 10.28 RS-4M/-10M -B 600 236*236*40 497*251*100 2,400 11.09 RS-6/8/15/20/25M -B 300 230*190*46 410*243*157 1,800 13.37 WOM -B 600 165*252*59 347*320*271 6,000 11.0 PACKAGE PACKING CODE EA PER BOX INNER BOX SIZE CARTON SIZE (mm) (mm) EA PER CARTON WEIGHT(Kg) BDB -C 2,000 450*140*84 464*305*283 12,000 14.18 D2PAK -C 2,000 550*140*92 572*308*120 4,000 10.20 DB-1 -C 2,500 450*140*84 464*305*283 15,000 14.30 DB-LS -C 4,000 450*140*84 464*305*283 24,000 16.45 DB-S -C 4,000 450*140*84 464*305*283 24,000 18.44 RBU -C 1,000 490*135*110 510*293*131 2,000 13.62 RS-1M/-2M -C 1,350 540*118*118 560*259*144 2,700 12.03 RS-4M/-10M -C 900 540*118*118 560*259*144 1,800 12.82 RS-6/8/15/20/25M -C 600 490*135*110 510*293*131 1,200 13.12 (I)TO-220/TO-220(A) -C 2,000 550*140*92 572*308*120 4,000 11.80 TO-247 -C 900 550*140*92 572*308*120 1,800 7.60 TUBE PACK Visit http:// www.rectron.com for complete datasheets D34 DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.