G6E G6E
3
Characteristics
Contact
resistance
50 m
Ω
max.
Operate (set*) time
5 ms max. (mean value: approx. 2.9 ms; 48 VDC type: approx. 2.4 ms)
Release (reset*) time 5 ms max. (mean value: approx. 1.3 ms)
Bounce time
Operate:
3 ms max. (mean value: 0.37 ms)
Release:
3 ms max. (mean value: 1.12 ms)
Max. operating frequency
Mechanical:
36,000 operations/hr
Electrical:
1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
Ω
min. (at 500 VDC)
Dielectric withstand voltage
1,500 V
AC, 50/60 Hz for 1 min between coil and contacts
1,000 V
AC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage
1,500 V 10 x 160
µs (conforms to FCC Part 68)
V
ibration resistance
Destruction:
10 to 55 Hz, 5-mm double amplitude
Malfunction:
10 to 55 Hz, 3.3-mm double amplitude
Shock resistance
Destruction:
1,000 m/s
2
(approx. 100G)
Malfunction:
300 m/s
2
(approx. 30G)
Life expectancy
Mechanical:
100,000,000 operations min. (at 36,000 operations/hr)
Electrical:
100,000 operations min. (0.4 A at 125 V
AC resistive load;
0.2 A at 125 V
AC inductive load)
500,000 operations min. (2 A at 30 VDC resistive load;
1 A at 30 VDC inductive load)
200,000 operations min. (3 A at 30 VDC resistive load)
Ambient temperature
Operating: –40°
C to 70
°
C (with no icing)
Storage: –40°
C to 70
°
C (with no icing)
Ambient humidity
35% to 85%
Weight
Approx. 2.7 g
*Minimum set and reset signals width is 7 ms min.
Approved Standards
UL508 (File No. E41515)/CSA C22.2, No.14 (File No. LR31928)
Contact form
Coil ratings Contact ratings
SPDT
3 to 48 VDC
0.2 A, 250 V
AC (general use)
0.6 A, 125 V
AC (general use)
2 A, 30 VDC (resistive)
0.6 A, 125 VDC (resistive, Ag contact only)
Engineering Data
Max. Switching Capacity Ambient Temperature vs.
Maximum Voltage
Life Expectancy
Switching current (A)
Switching
voltage (V)
Switching current (A)
Life expectancy (x10 operations)
3
Ambient temperature (
°)
Maximum voltage (%)
DC resistive load
AC resis-
tive load
DC inductive load
(L/R = 7 ms)
AC inductive load
(cosφ
= 0.4)
30-VDC inductive load
(L/R = 7 ms)
30-VDC re-
sistive load
125-VAC re-
sistive load
125-VAC inductive load
(cosφ
= 0.4)
G6E-134P-US,
G6EK-134P-US,
G6EU-134P-US
G6E-134P-US
Only at 48VDC
100,000
50,000
3,000
10,000
5,000
3,000
1,000
500
300
100
50