Photologic® Slotted Optical Switch
“Wide Gap” Series
OPB900 through OPB913 Series (L, W__Z)
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue A.2 09/06
Page 3 of 4
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Electrical Characteristics (TA = -40°C to + 70° Unless otherwise noted)
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
Input Diode (See OPB240 for more information — for reference only)
VF Forward Voltage - - 1.7 V IF = 20 mA, TA = 25° C
IR Reverse Current - - 100 µA VR = 2 V, TA = 25° C
Output Photologic® Sensor (See OPB560 for more information — for reference only)
VCC Operating D.C. Supply Voltage 4.75 - 5.25 V
ICCL
Low Level Supply Current:
Buffered Totem-Pole Output
Buffered Open-Collector Output
- - 15 mA VCC = 5.25 V, IF = 0 mA(1)
Inverted Totem-Pole Output
Inverted Open-Collector Output - - 15 mA VCC = 5.25 V, IF = 20 mA(1)
ICCH
High Level Supply Current:
Buffered Totem-Pole Output
Buffered Open-Collector Output
- - 15 mA VCC = 5.25 V, IF = 20 mA(1)
Inverted Totem-Pole Output
Inverted Open-Collector Output - - 15 mA VCC = 5.25 V, IF = 0 mA(1)
VOL
Low Level Supply Current:
Buffered Totem-Pole Output
Buffered Open-Collector Output
- - 0.4 V VCC = 4.75 V, IOL = 12.8 mA, IF = 0 mA(1)
Inverted Totem-Pole Output
Inverted Open-Collector Output - - 0.4 V
VCC = 4.75 V, IOL = 12.8 mA , IF = 20 mA(1)
VOH
High Level Output Voltage:
Buffered Totem-Pole Output 2.4 - - V VCC = 4.75 V, IOH = -800 µA, IF = 20 mA(1)
Inverted Totem-Pole Output 2.4 - - V VCC = 4.75 V, IOH = -800 µA, IF = 0 mA(1)
IOH
High Level Output Current:
Buffered Open-Collector Output - - 100 µA VCC = 4.75 V, VOH = 30 V, TA = 25° C
Inverted Open-Collector Output - - 100 µA VCC = 4.75 V, VOH = 30 V, TA = 25° C
IF(+) LED Positive-Going Threshold Current - - 20 mA VCC = 5 V, TA = 25° C
IF(+)/IF(-) Hysteresis - 2 - - VCC = 5 V
IOS
Short Circuit Output Current:
Buffered Totem-Pole Output -30 - -100 mA
VCC = 5.25 V, IF = 20 mA
Output = GND
Inverted Totem-Pole Output -30 - -100 mA VCC = 5.25 V, IF = 0 mA
Output = GND
tr, tf Output Rise Time, Output Fall Time - 70 - ns
tPLH, tPHL Propagation Delay Low-High and High-
Low - 5 - µs
VCC = 5 V, TA = 25° C
IF = 0 or 20 mA
RL = 8 TTL Loads (Totem-Pole)
RL = 360 Ω (Open-Collector)
Notes:
(1) Normal application would be with light source blocked, simulated by IF = 0 mA.