5.1”
5.3”
1.8”
3.8”
6.2”
6.7”
2.3”
4.9”
8.2”
8.9”
3.4”
6.9”
X = 4.3” (109 mm) X = 5.4” (137 mm) X = 7.4” (188 mm)
X
X
1.4” 1.6”
2.0”
Standard EMI Version Standard EMI Version Standard EMI Version
Part No. AC 230 V, 50 Hz: 01800.0-00 01800.1-00 01801.0-00 01801.1-00 01802.0-00 01802.1-00
Part No. AC 120 V, 60 Hz: 01800.0-01 01800.1-01 01801.0-01 01801.1-01 01802.0-01 01802.1-01
Filter mat: Medium grade 350 g/m², filtering degree 94%, Particle Ø < 10 µm, G4 (EN 779)
Air volume
free blowing: 12 cfm (21 m³/h) 35 cfm (60 m³/h) 60 cfm (102 m³/h)
with exit filter: 9 cfm (16 m³/h) 24 cfm (42 m³/h) 40 cfm (68 m³/h)
Current consumption 230 V: 80 mA 100 mA 100 mA
120 V: 160 mA 180 mA 180 mA
Power consumption 230 V: 13W 15W 15W
120 V: 13W 15W 15W
Average noise level at 3 ft
DIN EN ISO 9614-2: 31 dB (A) 40 dB (A) 39 dB (A)
Mounting depth: 1.8” (45 mm) 2.3” (58 mm) 3.4” (86 mm)
Enclosure cut-out: 3.8” x 3.8” (97 x 97 mm +0.4) 4.9” x 4.9” (125 x 125 mm +0.4) 6.9” x 6.9” (176 x 176 mm +0.4)
Weight: 1.2 lbs (0.54 kg) 2.2 lbs (1.0 kg) 4.2 lbs (1.9 kg)
Air flow increases by approximately 15% for 120V / 60Hz models
FILTER FAN
FF 018 Series
EXHAUST FILTER EF 118 Series
Standard EMI Version Standard EMI Version Standard EMI Version
Part No.: 11800.0-00 11800.1-00 11801.0-00 11801.1-00 11802.0-00 11802.1-00
Filter mat: Medium grade 350 g/m², filtering degree 94%, Particle Ø < 10 µm, G4 (EN 779)
Mounting depth: 0.6” (16 mm) 0.6” (16 mm) 0.6” (16 mm)
Enclosure cut-out: 3.8” x 3.8” (97 x 97 mm +0.4) 4.9” x 4.9” (125 x 125 mm +0.4) 6.9” x 6.9” (176 x 176 mm +0.4)
Weight: 0.6 lbs (0.27 kg) 0.8 lbs (0.38 kg) 1.3 lbs (0.60 kg)
Mounting frame Hole centers for attaching with screws - hole Ø 1/8” (3 mm)
Ball bearing, aluminum frame, plastic impeller UL94V-O
Operational life min. 50,000 hrs at 77°F (RH 65%)
Ambient temperature -22°F to 158°F
2 lead wires 4” long with pressure clamps, type AWG 14 max.
DC Axial fan in 12 V, 24 V, 48 V available on request
Plastic, UL94V-O
Color light grey, temperature resistant -31°F to 158°F.
With double sided industrial adhesive band for affixing
to the outside of enclosure. Certain operating circumstances may
make the additional use of screws necessary.
OTHER TECHNICAL DATA:
Axial fan:
Filter fan & exhaust
filter housing:
Mounting frame:
Synthetic fiber with progressive construction, temperature resistant
to 212°F, self-extinguishing class F1.
Moisture resistant to 100% RH.
Can be cleaned by washing or vacuuming for reuse.
Replacement filter mats available on request.
The fan mounting on the EMI Version is plated and the mounting
frame is fitted with Be Cu contact strips.
Protection with standard filter mats G4: IP 54.
Using fine filter mats F5 increases the protection to IP 55 but
reduces the air volume.
Filter material:
STEGO, Inc. · 2270 Northwest Parkway · Suite 170 · Marietta, GA 30067 · Tel: (770) 984-0858 · Fax: (770) 984-0615
Toll free: 1-888-783-4611 (US & Canada only) · www.stegousa.com
U.S. Patent No. 6,699,301 B1
FF018-11-05/US
Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application.