CD143A-SR05LC – Steering/TVS Diode Array Series
Features
■RoHS compliant*
■Halogen free**
■ESD protection >15 kV
■Protects Vcc and two data lines
Applications
■Ethernet - 10/100/1000 Base T
■Firewire and USB
■Portable electronics
■Video/graphic cards
General Information
Absolute Maximum Ratings (@ TA= 25 °C Unless Otherwise Noted)
Electrical and Thermal Characteristics (@ TA= 25 °C Unless Otherwise Noted)
Notes:
1. See Peak Pulse Power vs. Pulse Time.
2. From Pin 4 to Pin 1.
3. See Pulse Wave Form.
4. From Pin 1 to Pin 3, Pin 1 to Pin 2, Pin 3 to Pin 4, Pin 2 to Pin 4.
5. GND is connected to ground, REF is connected to +VCC and input applies to VCC = 12 V. Vstgn = 30 mV, F = 1 MHz.
The Bourns®Model CD143A-SR05LC device provides ESD, EFT
and surge protection for the external ports of portable electronic
devices such as cell phones, handheld electronics and personal
computers.
The ESD protection provided by the component enables a data
port to withstand a minimum ±8 KV Contact / ±15 KV Air Discharge
per the ESD test method specified in IEC 61000-4-2. The device
measures 2.80 mm x 1.20 mm and is available in a SOT-143
package intended to be mounted directly onto an FR4 printed
circuit board.
The Bourns®device will meet IEC 61000-4-2 (ESD), IEC 61000-4-4
(EFT) and IEC 61000-4-5 (Surge) requirements.
Parameter Symbol Value Unit
Peak Pulse Power (tp= 8/20 µs)1PPP 250 W
Peak Pulse Current (tp= 8/20 µs) IPP 13 A
Operating Temperature TJ-55 to +125 ˚C
Storage Temperature TSTG -55 to +150 ˚C
Forward Voltage ( If= 15 mA, Pin 1-4) Vf1V
Parameter Symbol Value Unit
Breakdown Voltage Minimum @ 1 mA 2VBR 6.1 V
Working Peak Voltage 2VWM 5.0 V
Clamping Voltage Maximum @ IP= 1 A 2,3 VC9.0 V
Clamping Voltage Maximum @ IP 2,3 VC20 @ 17.5 A V
Leakage Current @ VWM 2ID1.0 µA
Capacitance Maximum per Data Line @ 0 V,
1 MHz 4,5 CJ3pF