Supercapacitors FT Series Overview Applications FT Series Supercapacitors, also known as Electric DoubleLayer Capacitors (EDLCs), are intended for high energy storage applications. Supercapacitors have characteristics ranging from traditional capacitors and batteries. As a result, supercapacitors can be used like a secondary battery when applied in a DC circuit. These devices are best suited for use in low voltage DC hold-up applications such as embedded microprocessor systems with flash memory. Benefits * Wide range of temperature from -40C to +85C * Maintenance free * Maximum operating voltage of 5.5 VDC * Highly reliable against liquid leakage * Lead-free and RoHS compliant Part Number System FT 0H 104 Z F Series Maximum Operating Voltage Capacitance Code Capacitance Tolerance Environmental FT FTW 0H = 5.5 VDC First two digits represent significant figures. Third digit specifies number of zeros to follow F code. Z = -20/+80% F = Lead-free One world. One KEMET (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com S6014_FT * 7/17/2020 1 Supercapacitors - FT Series 0.3 Minimum Sleeve H Maximum o D 0.5 Minimum Dimensions - Millimeters P 0.5 d1 0.1 d2 0.1 (Terminal) Part Number oD H P d1 d2 FT0H104ZF FT0H224ZF FT0H474ZF FT0H105ZF FT0H225ZF FT0H335ZF FT0H565ZF FTW0H104ZF 11.5 14.5 16.5 21.5 28.5 36.5 44.5 11.5 8.5 12.0 13.0 13.0 14.0 15.0 17.0 8.5 5.08 5.08 5.08 7.62 10.16 15.00 20.00 5.08 2.7 2.2 2.7 3.0 6.1 6.1 6.1 2.7 0.4 0.4 0.4 0.6 0.6 0.6 1.0 0.4 1.2 1.2 1.2 1.2 1.4 1.7 1.4 1.2 (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com S6014_FT * 7/17/2020 2 Supercapacitors - FT Series Performance Characteristics Supercapacitors should not be used for applications such as ripple absorption because of their high internal resistance (several hundred m to a hundred ) compared to aluminum electrolytic capacitors. Thus, its main use would be similar to that of secondary battery such as power back-up in DC circuit. The following list shows the characteristics of supercapacitors as compared to aluminum electrolytic capacitors for power back-up and secondary batteries. Secondary Battery Capacitor NiCd Lithium Ion Aluminum Electrolytic Supercapacitor Back-up ability - - - - Eco-hazard Cd - - - -20 to +60C -20 to +50C -55 to +105C -40 to +85C (FR, FT, FMR Type) Few hours Few hours Few seconds Few seconds Approximately 500 times Approximately 500 to 1,000 times Limitless (*1) Limitless (*1) Yes Yes None None Flow Soldering Not applicable Not applicable Applicable Applicable Automatic Mounting Not applicable Not applicable Applicable Applicable (FM and FC series) Leakage, explosion Leakage, combustion, explosion, ignition Heat-up, explosion Gas emission (*2) Operating Temperature Range Charge Time Charge/Discharge Life Time Restrictions on Charge/Discharge Safety Risks (*1) Aluminum electrolytic capacitors and supercapacitors have limited lifetime. However, when used under proper conditions, both can operate within a predetermined lifetime. (*2) There is no harm as it is a mere leak of water vapor which transitioned from water contained in the electrolyte (diluted sulfuric acid). However, application of abnormal voltage surge exceeding maximum operating voltage may result in leakage and explosion. Typical Applications Intended Use (Guideline) Back-up for 1 hour or less Power Supply (Guideline) 50 mA and below Application Examples of Equipment Embedded memory backup DVD player, television, game console, set-top box Motor driver DVD player, printer, projector, camera (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com Series FT series S6014_FT * 7/17/2020 3 Supercapacitors - FT Series Environmental Compliance All KEMET supercapacitors are RoHS compliant. Table 1 - Ratings & Part Number Reference Part Number Maximum Operating Voltage (VDC) Nominal Capacitance Charge System (F) Discharge System (F) Maximum ESR at 1 kHz () Maximum Current at 30 Minutes (mA) Weight (g) 1.6 FT0H104ZF 5.5 0.10 0.14 16 0.15 FT0H224ZF 5.5 0.22 0.28 10 0.33 4.1 FT0H474ZF 5.5 0.47 0.60 6.5 0.71 5.3 FT0H105ZF 5.5 1.0 1.3 3.5 1.5 10.0 FT0H225ZF 5.5 2.2 2.8 1.8 3.3 18.0 FT0H335ZF 5.5 3.3 4.2 1.0 5.0 38.0 FT0H565ZF 5.5 5.6 7.2 0.6 8.4 72.0 FTW0H104ZF 5.5 0.10 0.14 16 0.15 2.0 Part numbers in bold type represent popularly purchased components. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com S6014_FT * 7/17/2020 4 Supercapacitors - FT Series Specifications Item FT Type Test Conditions (conforming to JIS C 5160-1) Category Temperature Range -40C to +85C Maximum Operating Voltage 5.5 VDC Capacitance Refer to Table 1 Refer to "Measurement Conditions" Capacitance Allowance +80%, -20% Refer to "Measurement Conditions" ESR Refer to Table 1 Measured at 1 kHz, 10 mA; See also "Measurement Conditions" Current (30 minutes value) Refer to Table 1 Refer to "Measurement Conditions" Capacitance > 90% of initial ratings ESR 120% of initial ratings Current (30 minutes value) 120% of initial ratings Appearance No obvious abnormality Surge voltage: Charge: Discharge: Number of cycles: Series resistance: Surge Capacitance ESR Capacitance ESR Characteristics in Different Temperature Phase 2 Phase 3 Capacitance ESR 50% of initial value 300% of initial value 30% of initial value 700% of initial value 150% of initial value Phase 5 Satisfy initial ratings Current (30 minutes value) 1.5 CV (mA) Capacitance Within 20% of initial value ESR Phase 6 Current (30 minutes value) Lead Strength (tensile) Vibration Resistance Satisfy initial ratings Conforms to 4.9 Satisfy initial ratings Conforms to 4.13 Frequency: Testing Time: 10 to 55 Hz 6 hours Conforms to 4.11 Solder temp: Dipping time: +245 5C 5 0.5 seconds No obvious abnormality Over 3/4 of the terminal should be covered by the new solder Solderability +25 2C -25 2C -40 2C +25 2C +85 2C +25 2C No terminal damage Current (30 minutes value) Appearance Conforms to 4.17 Phase 1: Phase 2: Phase 3: Phase 4: Phase 5: Phase 6: 0 852C Satisfy initial ratings Capacitance ESR Discharge resistance: Temperature: 6.3 V 30 seconds 9 minutes 30 seconds 1,000 0.10 F 150 0.22 F 56 0.47 F 30 1.0 F 15 2.2 F 10 3.3 F 10 5.6 F 10 1.6 mm from the bottom should be dipped. Capacitance Solder Heat Resistance ESR Satisfy initial ratings Conforms to 4.10 Solder temp: Dipping time: No obvious abnormality 1.6 mm from the bottom should be dipped. Satisfy initial ratings Conforms to 4.12 Temperature Condition: Current (30 minutes value) Appearance Capacitance Temperature Cycle ESR Current (30 minutes value) Appearance No obvious abnormality (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com Number of cycles: +260 10C 10 1 seconds -40C Room temperature +85C Room temperature 5 cycles S6014_FT * 7/17/2020 5 Supercapacitors - FT Series Specifications cont. Item High Temperature and High Humidity Resistance High Temperature Load FT Type Capacitance Within 20% of initial value ESR 120% of initial ratings Current (30 minutes value) 120% of initial ratings Appearance No obvious abnormality Capacitance Within 30% of initial value ESR < 200% of initial ratings Current (30 minutes value) < 200% of initial ratings Appearance No obvious abnormality Test Conditions (conforming to JIS C 5160-1) Conforms to 4.14 Temperature: Relative humidity: Testing time: Conforms to 4.15 Temperature: Voltage applied: Series protection resistance: Testing time: +402C 90 to 95% RH 2408 hours +852C Maximum operating voltage 0 1,000+48 (+48/-0) hours Marking Date Code Serial Number A1 Supercapacitor Supercapacitor 001 FT FT A1 5.5 V 85C 0.22 F 5.5 V 85C 0.22 F Maximum Operating Voltage Nominal Capacitance Negative Polarity Identification Mark Packaging Quantities Part Number Bulk Quantity per Box FT0H104ZF FT0H224ZF FT0H474ZF FT0H105ZF FT0H225ZF FT0H335ZF FT0H565ZF FTW0H104ZF 1,000 pieces 400 pieces 400 pieces 90 pieces 50 pieces 30 pieces 20 pieces 1,000 pieces (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com S6014_FT * 7/17/2020 6 Supercapacitors - FT Series Measurement Conditions Capacitance (Charge System) Capacitanceiscalculatedfromexpression(9)bymeasuringthechargetimeconstant()ofthecapacitor(C).Priorto measurement, the capacitor is discharged by shorting both pins of the device for at least 30 minutes. In addition, use the polarity indicator on the device to determine correct orientation of capacitor for charging. Rc Capacitance: C= Eo: 3.0 (V) Product with maximum operating voltage of 3.5 V 5.0 (V) Product with maximum operating voltage of 5.5 V 6.0 (V) Product with maximum operating voltage of 6.5 V 10.0 (V) Product with maximum operating voltage of 11 V 12.0 (V) Product with maximum operating voltage of 12 V : TimefromstartofcharginguntilVcbecomes0.632Eo(V) (seconds) Rc: Seetablebelow(). (F) (9) Switch Eo Rc C + Vc - Charge Resistor Selection Guide Cap 0.010 F 0.022 F 0.033 F 0.047 F 0.10 F FA FE FS FYD FY FYH FR FM, FME FMR - - - - - - 1,000 - 1,000 2,000 2,000 2,000 - - - - - - 1,000 1,000 1,000 2,000 1,000 1,000 510 510 510 1,000 510 1,000 0.22 F 200 200 200 510 510 0.33 F 0.47 F 1.0 F 1.4 F 1.5 F 2.2 F 2.7 F 3.3 F 4.7 F 5.0 F 5.6 F 10.0 F 22.0 F 50.0 F 100.0 F 200.0 F - 100 51 - - - - - - - - - - - - - - 100 51 - 51 - - - - - - - - - - - - 100 100 - - - - - - 100 - - - - - - - 200 100 200 - 100 - - - - - - - - - - - 200 100 - - - - - - - - - - - - - FMC FG, FGR FGH FT 5,000 - 5,000 - - 2,000 - 2,000 - - Discharge - - - - 2000 1,000 2,000 - - 1000 1,000 1,000 Discharge 510 0H: Discharge 510 - 1,000 Discharge 200 0V:1000 - - Discharge - - - 200 - - 1,000 Discharge 100 100 - - 510 Discharge 100 - - - - - - - - - 510 - - - - - 200 - 51 - - - - - - - - - - - 51 - - - 100 - - - - - - - - - - - - - 20 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - FC, FCS HV - Discharge - - Discharge - - - - - Discharge - - Discharge Discharge - - - - - - - - - - - - - - - Discharge - - - Discharge - Discharge - - Discharge Discharge Discharge Discharge Discharge *Capacitance values according to the constant current discharge method. *HV Series capacitance is measured by discharge system. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com S6014_FT * 7/17/2020 7 Supercapacitors - FT Series Measurement Conditions cont. Capacitance (Discharge System) As shown in the diagram below, charging is performed for a duration of 30 minutes once the voltage of the capacitor terminal reaches 5.5 V. Then, use a constant current load device and measure the time for the terminal voltage to drop from 3.0 to 2.5 V upon discharge at 0.22 mA per 0.22 F, for example, and calculate the static capacitance according to the equation shown below. Note: The current value is 1 mA discharged per 1 F. C I x (T 2 T 1 ) V 1 V 2 (F) 5.5 V A C V (V) 0.22 mA (I) SW R 5.5 V V 1 : 3.0 V V1 V 2 : 2.5 V V2 T1 T2 Time (seconds) 30 minutes Capacitance (Discharge System - 3.5 V, 3.6 V) As shown in the diagram below, charging is performed for a duration of 30 minutes once the voltage of the capacitor terminal reaches 3.5 V (3.6 V). Then, use a constant current load device and measure the time for the terminal voltage to drop from 1.8 to 1.5 V upon discharge at 1.0 mA per 1.0 F, for example, and calculate the static capacitance according to the equation shown below. (V) SW C I x (T 2 T 1 ) V 1 V 2 (F) 3.5 V (3.6 V) A C V R 3.5 V (3.6 V) V 1 : 1.8 V V1 V 2 : 1.5 V V2 T1 T2 Time (seconds) 30 minutes Capacitance (Discharge System - HV Series) As shown in the diagram below, charging is performed for a duration of 30 minutes once the voltage of the capacitor terminal reaches maximum operating voltage. Then, use a constant current load device and measure the time for the terminal voltage to drop from 2.0 to 1.5 V upon discharge at 1.0 mA per 1.0 F, and calculate the static capacitance according to the equation shown below. (V) SW C I x (T 2 T 1 ) V 1 V 2 (F) 2.7 V (2.5 V) V A C R 2.7 V (2.5 V) V 1 : 2.0 V V1 V 2 : 1.5 V V2 T1 T2 Time (seconds) 30 minutes (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com S6014_FT * 7/17/2020 8 Supercapacitors - FT Series Measurement Conditions cont. Equivalent Series Resistance (ESR) ESR shall be calculated from the equation below. ESR VC 0.01 10mA () f:1kHz C VC Current (at 30 minutes after charging) Current shall be calculated from the equation below. Prior to measurement, both lead terminals must be short-circuited for a minimum of 30 minutes. The lead terminal connected to the metal can case is connected to the negative side of the power supply. Eo: 2.5 VDC (HV Series 50 F) 2.7 VDC (HV Series except 50 F) 3.0 VDC (3.5 V type) 3.6 VDC (3.6 V type) 5.0 VDC (5.5 V type) 6.0 VDC (6.5 V type) 10.0 VDC (11 V type) 12.0 VDC (12 V type) VR Current VR RC (A) EO RC SW C Rc: 1,000(0.01F,0.022F,0.047F) 100(0.10F,0.22F,0.33F,0.47F) 10(1.0F,1.4F,1.5F,2.2F,3.3F,4.7F,5.6F) 2.2(HVSeries) However, FS Seres 11 V type and 12 V type 1000.47F,1.0F 105.0F Self-Discharge Characteristic (0H - 5.5 V Products) Theself-dischargecharacteristicismeasuredbychargingavoltageof5.0VDC(chargeprotectionresistance:0) according to the capacitor polarity for 24 hours, then releasing between the pins for 24 hours and measuring the pin-topinvoltage.Thetestshouldbecarriedoutinanenvironmentwithanambienttemperatureof25Corbelowandrelative humidityof70%RHorbelow.Thesolderingischecked. 4. Dismantling There is a small amount of electrolyte stored within the capacitor. Do not attempt to dismantle as direct skin contact with theelectrolytewillcauseburning.Thisproductshouldbetreatedasindustrialwasteandnotisnottobedisposedofbyfire. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com S6014_FT * 7/17/2020 9 Supercapacitors - FT Series Notes on Using Supercapacitors or Electric Double-Layer Capacitors (EDLCs) 1. Circuitry Design 1.1 Useful life The FC Series Supercapacitor (EDLC) uses an electrolyte in a sealed container. Water in the electrolyte can evaporate while in use over long periods of time at high temperatures, thus reducing electrostatic capacity which in turn will create greater internal resistance. The characteristics of the supercapacitor can vary greatly depending on the environment in which it is used. Basic breakdown mode is an open mode due to increased internal resistance. 1.2 Fail rate in the field Based on field data, the fail rate is calculated at approximately 0.006 Fit. We estimate that unreported failures are ten times this amount. Therefore, we assume that the fail rate is below 0.06 Fit. 1.3 Exceeding maximum usable voltage Performance may be compromised and in some cases leakage or damage may occur if applied voltage exceeds maximum working voltage. 1.4 Use of capacitor as a smoothing capacitor (ripple absorption) As supercapacitors contain a high level of internal resistance, they are not recommended for use as smoothing capacitors in electrical circuits. Performance may be compromised and, in some cases, leakage or damage may occur if a supercapacitor is used in ripple absorption. 1.5 Series connections As applied voltage balance to each supercapacitor is lost when used in series connection, excess voltage may be applied to some supercapacitors, which will not only negatively affect its performance but may also cause leakage and/or damage. Allow ample margin for maximum voltage or attach a circuit for applying equal voltage to each supercapacitor (partial pressure resistor/voltage divider) when using supercapacitors in series connection. Also, arrange supercapacitors so that the temperature between each capacitor will not vary. 1.6 Case Polarity The supercapacitor is manufactured so that the terminal on the outer case is negative (-). Align the (-) symbol during use. Even though discharging has been carried out prior to shipping, any residual electrical charge may negatively affect other parts. 1.7 Use next to heat emitters Useful life of the supercapacitor will be significantly affected if used near heat emitting items (coils, power transistors and posistors, etc.) where the supercapacitor itself may become heated. 1.8 Usage environment This device cannot be used in any acidic, alkaline or similar type of environment. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com S6014_FT * 7/17/2020 10 Supercapacitors - FT Series Notes on Using Supercapacitors or Electric Double-Layer Capacitors (EDLCs) cont. 2. Mounting 2.1 Mounting onto a reflow furnace Except for the FC series, it is not possible to mount this capacitor onto an IR / VPS reflow furnace. Do not immerse the capacitor into a soldering dip tank. 2.2 Flow soldering conditions Keep solder under 260C and soldering time to within 10 seconds when using the flow automatic soldering method. (Except for the FC and HV series) 2.3 Installation using a soldering iron Care must be taken to prevent the soldering iron from touching other parts when soldering. Keep the tip of the soldering iron under 400C and soldering time to within 3 seconds. Always make sure that the temperature of the tip is controlled. Internal capacitor resistance is likely to increase if the terminals are overheated. 2.4 Lead terminal processing Do not attempt to bend or polish the capacitor terminals with sand paper, etc. Soldering may not be possible if the metallic plating is removed from the top of the terminals. 2.5 Cleaning, Coating, and Potting Except for the FM series, cleaning, coating and potting must not be carried out. Consult KEMET if this type of procedure is necessary. Terminals should be dried at less than the maximum operating temperature after cleaning. 3. Storage 3.1 Temperature and humidity Make sure that the supercapacitor is stored according to the following conditions: Temperature: 5 - 35C (Standard 25C), Humidity: 20 - 70% (Standard: 50%). Do not allow the build up of condensation through sudden temperature change. 3.2 Environment conditions Make sure there are no corrosive gasses such as sulfur dioxide, as penetration of the lead terminals is possible. Always store this item in an area with low dust and dirt levels. Make sure that the packaging will not be deformed through heavy loading, movement and/or knocks. Keep out of direct sunlight and away from radiation, static electricity and magnetic fields. 3.3 Maximum storage period This item may be stored up to one year from the date of delivery if stored at the conditions stated above. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com S6014_FT * 7/17/2020 11 Supercapacitors - FT Series KEMET Electronics Corporation Sales Offices Foracompletelistofourglobalsalesoffices,pleasevisitwww.kemet.com/sales. Disclaimer Allproductspecifications,statements,informationanddata(collectively,the"Information")inthisdatasheetaresubjecttochange.Thecustomerisresponsiblefor checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on KEMET Electronics Corporation's ("KEMET") knowledge of typical operating conditions for such applications,butarenotintendedtoconstitute-andKEMETspecificallydisclaims-anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET's products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product-related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. When providing KEMET products and technologies contained herein to other countries, the customer must abide by the procedures and provisions stipulated in all applicableexportlawsandregulations,includingwithoutlimitationtheInternationalTrafficinArmsRegulations(ITAR),theUSExportAdministrationRegulations (EAR) and the Japan Foreign Exchange and Foreign Trade Act. KEMET is a registered trademark of KEMET Electronics Corporation. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com S6014_FT * 7/17/2020 12