JS VDE 1a/1c 10A cubic type power relays RoHS compliant JS RELAYS FEATURES TYPICAL APPLICATIONS * Miniature size with universal terminal footprint * High contact capacity: 10 A * TV-5 type available (Standard type) 1 Form A type TV-5 1 Form C type TV-5 (N.O. side only) * VDE, TUV also approved * Sealed construction for automatic cleaning (Standard type) * Class B and F coil insulation type also available. * EN60335-1 GWT compliant (Tested by VDE) type available * Surge voltage 6 kV type also available 1. Home appliances Air conditioner, heater, etc. 2. Office machines PPC, facsimile, etc. 3. Vending machines ORDERING INFORMATION JS F Contact arrangement 1: 1 Form C (Standard) 1a: 1 Form A (Standard) 1aP: 1 Form A (Long endurance type) Protective construction Nil: Sealed type F: Flux-resistant type Coil insulation class Nil: Class E insulation B: Class B insulation F: Class F insulation Nominal coil voltage (DC) 5V, 6V, 9V, 12V, 18V, 24V, 48V Contact material F: AgSnO2 type Flame resistance and tracking resistance Nil: - T: EN60335-1 (Conform) Surge voltage 6K: 6kV type Standard: UL, CSA, VDE, TUV (Standard type) UL, CSA, VDE (Long endurance type and EN60335-1 GWT compliant type) UL, CSA (Surge voltage 6kV type) Notes: 1. When ordering TV rated (TV-5) types, please consult us. 2. Contact arrangement 1aP type is Flux-resistant type only (Class B insulation only). Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ ASCTB186E 201202-T JS TYPES Contact arrangement Nominal coil voltage Sealed type Part No. Flux-resistant type Part No. 1 Form A (Standard) 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC JS1a-5V-F JS1a-6V-F JS1a-9V-F JS1a-12V-F JS1a-18V-F JS1a-24V-F JS1a-48V-F JS1aF-5V-F JS1aF-6V-F JS1aF-9V-F JS1aF-12V-F JS1aF-18V-F JS1aF-24V-F JS1aF-48V-F 1 Form A Long endurance type 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC - - - - - - - JS1aPF-B-5V-F JS1aPF-B-6V-F JS1aPF-B-9V-F JS1aPF-B-12V-F JS1aPF-B-18V-F JS1aPF-B-24V-F JS1aPF-B-48V-F 1 Form C (Standard) 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC JS1-5V-F JS1-6V-F JS1-9V-F JS1-12V-F JS1-18V-F JS1-24V-F JS1-48V-F JS1F-5V-F JS1F-6V-F JS1F-9V-F JS1F-12V-F JS1F-18V-F JS1F-24V-F JS1F-48V-F Standard packing Carton: 100 pcs. Case: 500 pcs. Notes: 1. Class B and F coil insulation types available. Ex) JS1aF-B-12V-F, JS1aF-F-12V-F 2. EN60335-1 GWT compliant types available. When ordering, please add suffix "T". Ex) JS1aF-B-12V-FT 3. Surge voltage 6kV types available. When ordering, please add suffix "6K" (except for Long endurance type and EN60335-1 GWT compliant type). Ex) JS1aF-B-12V-F-6K RATING 1. Coil data Nominal coil voltage 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC Pick-up voltage (at 20C 68F) 70%V or less of nominal voltage (Initial) Drop-out voltage (at 20C 68F) Nominal operating current [10%] (at 20C 68F) Coil resistance [10%] (at 20C 68F) 10%V or more of nominal voltage (Initial) 72 mA 60 mA 40 mA 30 mA 20 mA 15 mA 7.5mA 69.4 100 225 400 900 1,600 6,400 Nominal operating power (at 20C 68F) Max. applied voltage (at 70C 158F) 130%V of nominal voltage 360mW [When using relays at 85C 185F, see Note*] Note: * When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1C 33.8F with 20C 68F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range. ASCTB186E 201202-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ JS 2. Specifications Characteristics Contact Item Contact material Contact resistance (Initial) Arrangement Specifications AgSnO2 type Max. 100 m (By voltage drop 6 V DC 1A) 1 Form A, 1 Form C 1 Form A Long endurance type 10 A 250 V AC (NO), 10 A 125 V AC, 10 A 250 V AC, 10 A 277 V AC, 5 A 30 V DC 6 A 277 V AC, 5 A 30 V DC 2,500VA 150W (NO), 1,662VA 150W (NC) 2,770VA 150W 250V AC, 100V DC (0.5A) 10A (AC), 5A (DC) 360mW 100mA, 5V DC Min. 100M (at 500V DC) Measurement at same location as "Breakdown voltage" section. Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Nominal operating power Min. switching capacity*1 Insulation resistance (Initial) Rating Breakdown voltage (Initial) Electrical characteristics Between open contacts Between contact and coil 750 Vrms for 1 min. (Detection current: 10 mA) 1,500 Vrms for 1 min. (Detection current: 10 mA) Max. 35C 95F (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 10A, at 70C 158F) Max. 10 ms (excluding contact bounce time.) Max. 10 ms (excluding contact bounce time) (Without diode) 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.) 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10s.) 10 to 55 Hz at double amplitude of 2 mm Min. 107 Temperature rise (coil) Operate time (at nominal voltage) (at 20C 68F) Release time (at nominal voltage) (at 20C 68F) Functional Destructive Functional Vibration resistance Destructive Mechanical (at 180 times/min.) Shock resistance Mechanical characteristics Expected life Conditions 1x105 [10A 125V AC, 6A 277V AC, 5A 30V DC] 5x104 (NO contact only) [10A 250V AC] Electrical (resistive load) 2x105 [10A 277V AC] 1.5x105 [10A 250V AC (at 20 times/min., 105C 221F)] 1x105 [5A 30V DC] -40C to +70C -40F to +158F (Class E insulation) -40C to +85C -40F to +185F -40C to +105C -40F to +221F*3; (Class B insulation)*3 Humidity: 5 to 85% R.H. (Not freezing and -40C to +105C -40F to +221F condensing at low temperature) (Class F insulation)*3 Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. (at nominal switching capacity) Approx. 12 g .423 oz Conditions for operation, transport and storage*2 Max. operating speed Unit weight Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. *3. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1C 33.8F with 20C 68F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range. REFERENCE DATA 1. Maximum value for switching capacity 2.-(1) Coil temperature rise 2.-(2) Coil temperature rise Sample: 5 pcs., JS1a-24V-F Measured portion: Inside the coil Contact current: 5 A Sample: 5 pcs., JS1a-24V-F Measured portion: Inside the coil Contact current: 10 A 60 100 60 10 1 DC resistive load 10 30 100 Contact voltage, V Panasonic Corporation 26C 70C 85C 40 30 Temperature rise, C AC resistive load Temperature rise, C Contact current, A 26C 50 50 40 30 20 20 10 10 0 100 120 140 Coil applied voltage, %V Automation Controls Business Unit 160 70C 85C 0 100 120 140 160 Coil applied voltage, %V industrial.panasonic.com/ac/e/ ASCTB186E 201202-T JS 3. Life curve 4. Operate/release time 5. Ambient temperature characteristics Ambient temperature: Room temperature Sample: 25 pcs., JS1-12V-F Sample: 6 pcs., JS1-12V-F Life, x104 125V AC resistive load 10 Changing ration, % Operate/release time, ms 100 10 Operate time 8 10 6 20 40 60 80 4 1 2 3 4 5 6 7 8 9 0 10 80 Contact current, A 100 -20 140 Coil applied voltage, %V DIMENSIONS (mm inch) The CAD data of the products with a External dimensions CAD Data 120 Ambient temperature C -10 Max. - x Min. Max. - x Min. Release time 0 Drop-out voltage -60 -40 -20 0 2 1 Pick-up voltage 20 CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ Schematic (Bottom view) 1 Form A N.O. 16 .630 0.4 .016 PC board pattern (Bottom view) 1 Form A (Standard, High Power) 4-1.3 dia. 4-.051 dia. COM COIL 3.9 .154 0.24 .009 12 .472 0.8 .031 0.8 .031 1 Form C N.O. 0.4 .016 2 16 .630 1.2 .047 2.3 .091 COIL 12.2 .480 1 Form C 3 N.O. 12 .472 1 2 .079 COM N.C. (Standard) 4 N.C. 5 5-1.3 dia. 5-.051 dia. 0.4 .016 2 .079 12.2 .480 22 .866 12 .472 Note: Terminal No. 4 is only for Standard 1 Form C type Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: 2 .079 General tolerance 0.1 .004 0.2 .008 0.3 .012 12.2 .480 Tolerance: 0.1 .004 SAFETY STANDARDS File No. E43028 UL/C-UL (Recognized) Contact rating 10A 125V AC, 6A 277V AC 5A 30V DC, 1/8HP 125V AC 1/8HP 277V AC 12A 125V AC 12A 277V AC 10A 125V AC (N.O., 85C) 4FLA/4LRA125V AC 105C (N.O.) 2FLA/4LRA125V AC 105C (N.C.) 1/3HP 277V AC 75C N.O. CSA (Certified) File No. Contact rating LR26550 10A 125V AC 12A 125V AC 6A 277V AC 12A 277V AC 5A 30V DC 1/8HP 125V AC 1/8HP 277V AC File No. 40011475 VDE (Certified) Contact rating 10A 125V AC (cos =1.0) 6A 250V AC (cos =1.0) TV rating (UL/CSA) File No. Rating UL 1aTV-5 E43028 1cTV-5 (N.O.) CSA LR26550 TUV (Certified) File No. Rating B 10 02 10A 125V AC (cos =1.0) 13461 271 6A 250V AC (cos =1.0) For Cautions for Use. ASCTB186E 201202-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/