TECHNICAL DATASHEET LED Driver LNE-150W Series / LNE-V150W LNE Highlights & Features - - - - - - Universal AC input voltage from 90-305Vac High efficiency > 94.0% With IP65/ 67 protection for most outdoor applications Built-in Active PFC and conforms to harmonic current IEC/EN 61000-3-2, Class C Adjustable constant current level through internal potentiometer Common mode 6kV and differential mode 4kV surge immunity Safety Standards CB Certified for worldwide use Model Number: LNE-V150W Unit Weight: 1.04 kg Dimensions (L x W x D): 228 x 68 x 38.8 mm General Description Delta LED drivers come in different series to suit different application needs. The LNE series features adjustable output voltage and current level. All the models come in full corrosion resistance aluminum casing and major international safety certifications. LNE series offers the capability to achieve different level of LED brightness via built-in dimming function to meet various application and energy optimization needs. The products are designed and rigorously tested to work with various indoor and outdoor LED lighting conditions. Featuring high surge immunity (CM: 6kV, DM: 4kV) and complying to IP65/IP67 make Delta LNE series an essential part of an energy efficient LED lighting power solution for both indoor and outdoor applications. Model Information LNE LED Driver Model Number Input Voltage Range Output Voltage Output Current LNE-12V150W 90-305Vac (LNE-V150WA) 12Vdc 12.50A LNE-24V150W 90-277Vac (LNE-V150WC) 24Vdc 6.30A 36Vdc 4.20A LNE-36V150W LNE-48V150W 48Vdc 3.20A LNE-54V150W 54Vdc 2.80A Model Numbering LNE - V LED Driver Output Voltage Output Power 12V (150W series 24V model) 36V 48V 54V 1 150W Package Type A - IP65 with adjustable VR D - IP67 with dimming and without adjustable VR Safety Approval A - UL approval C - ENEC, CE and CCC approval Variable A - Delta standard All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (May 2015, Rev. 00) TECHNICAL DATASHEET LED Driver LNE-150W Series / LNE-V150W Specifications Model Number LNE-12V150W LNE-24V150W LNE-36V150W LNE-48V150W LNE-54V150W Input Ratings / Characteristics Nominal Input Voltage 100-277Vac (LNE-V150WA) 100-240Vac (LNE-V150WC) Input Voltage Range 90-305Vac (LNE-V150WA) Nominal Input Frequency 90-277Vac (LNE-V150WC) 50-60Hz Input Frequency Range 47-63Hz Input Current 1.70A typ. @ 115Vac, 0.75A typ. @ 230Vac, 0.70A typ. @ 277Vac Efficiency at 100% Load 115Vac 89.0% typ. 91.5% typ. 91.0% typ. 91.5% typ. 91.5% typ. 230Vac 91.0% typ. 93.0% typ. 93.0% typ. 94.0% typ. 94.0% typ. 277Vac 91.0% typ. 93.0% typ. 93.0% typ. 94.0% typ. 94.0% typ. Max Inrush Current (Cold Start) 65A typ. @ 230Vac Power Factor at 100% Load 0.98 typ. @ 115Vac 0.95 typ. @ 230Vac 0.92 typ. @ 277Vac Leakage Current < 0.75mA @ 277Vac 2 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (May 2015, Rev. 00) TECHNICAL DATASHEET LED Driver LNE-150W Series / LNE-V150W Power Factor Vs Output Load LNE-12V150W LNE-24V150W LNE-36V150W LNE-48V150W LNE-54V150W 3 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (May 2015, Rev. 00) TECHNICAL DATASHEET LED Driver LNE-150W Series / LNE-V150W Efficiency Vs Output Load at Nominal Output Voltage LNE-12V150W LNE-24V150W LNE-36V150W LNE-48V150W LNE-54V150W 4 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (May 2015, Rev. 00) TECHNICAL DATASHEET LED Driver LNE-150W Series / LNE-V150W Model Number LNE-12V150W LNE-24V150W LNE-36V150W LNE-48V150W LNE-54V150W Nominal Output Voltage 12Vdc 24Vdc 36Vdc 48Vdc 54Vdc Output Voltage Adjustment Range* 10.8-13.5V 22.0-27.0V 33.0-40.0V 43.0-53.0V 49.0-58.0V Nominal Output Current 12.5A 6.3A 4.2A 3.2A 2.8A Output Current Adjustment Range* 12.50-6.25A 6.30-3.15A 4.20-2.10A 3.20-1.60A 2.80-1.40A Output Power 150W 151.2W 151.2W 153.6W 151.2W Line Regulation 0.5% (@ 100-277Vac input) Load Regulation (@ 100-277Vac input, 0-100% load) PARD (20MHz) 2.0% 1.0% 1.0% 0.5% 0.5% < 150mVpp < 150mVpp < 200mVpp < 200mVpp < 200mVpp Rise Time < 50ms @ 115Vac & 230Vac & 277Vac Start-up Time Hold-up Time 1000ms typ. @ 115Vac (100% load) 500ms typ. @ 230Vac & 277Vac (100% load) 16ms typ. @ 115Vac & 230Vac & 277Vac (100% load) Dynamic Response (Overshoot & Undershoot O/P Voltage) 5% @ 0-100% load (Slew Rate: 0.1A/S) Output Ratings / Characteristics * For LNE-150WA package type only. 5 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (May 2015, Rev. 00) TECHNICAL DATASHEET LED Driver LNE-150W Series / LNE-V150W Model Number LNE-12V150W LNE-24V150W LNE-36V150W LNE-48V150W LNE-54V150W Mechanical Casing Aluminium Dimensions (L x W x D) 228 x 68 x 38.8 mm Unit Weight 1.04 kg Cooling System Convection Wire Input Output Dimming Noise (1 Meter from power supply) 2 VDE H05RN-F3G1.0mm UL SJTW 18AWGX3C VDE UL VDE H07RN-F2x1.5mm SJTW 14AWGX2C H05RN-F2x1.0mm2 Line: Brown, Neutral: Blue, PE: Green/Yellow Line: Brown, Neutral: Blue, PE: Green/Yellow Positive: Red, Negative: Black Positive: Red, Negative: Black Positive: White, Negative: Blue UL SJTW 18AWGX2C Positive: White, Negative: Blue 2 Sound Pressure Level (SPL) < 25dbA Environment Surrounding Air Temperature Operating -40C to +70C Storage -40C to +85C Power De-rating > 60C de-rate power by 4% / C < 100Vac de-rate power by 2% / Vac Operating Humidity 5 to 95% RH (Non-Condensing) Operating Altitude 0 to 3,000 Meters Shock Test (Non-Operating) IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions Vibration (Non-Operating) IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction Pollution Degree 2 Protections Overvoltage 13.8-16.8V, Latch Mode 27.6-33.6V, Latch Mode Overload / Overcurrent 95-108%of rated load current, constant current limit Auto-Recovery when the fault is removed Over Temperature Hiccup Mode, Auto-Recovery when the fault is removed Short Circuit Constant current limit , Auto-Recovery when the fault is removed Degree of Protection IP65 (LNE-V150W A) Protection Against Shock IP67 (LNE-V150W D) Class I with PE* connection 41.4-50.4V, Latch Mode *PE: Primary Earth 6 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (May 2015, Rev. 00) 55.2-67.2V, Latch Mode 62.1-75.6V, Latch Mode TECHNICAL DATASHEET LED Driver LNE-150W Series / LNE-V150W Model Number LNE-24V150W LNE-12V150W LNE-36V150W LNE-48V150W LNE-54V150W Reliability Data MTBF > 700,000 hrs. as per Telcordia SR-332 I/P: 115Vac, O/P: 100% load, Ta: 25C Expected Cap Life Time 10 years (115Vac & 230Vac, 50% load @ 40C) Safety Standards / Directives Electrical Safety CB scheme to IEC 61347-1, IEC 61347-2-13 ENEC to EN 61347-1, EN 61347-2-13 cRUus to UL 8750 (LNE-V150WA) CCC to GB19519.1, GB19510.14 Compliance to IEC/EN/UL 60950-1 CE In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC Material and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation Input to Output 3.85kVac Input to Ground 2.0kVac Output to Ground 1.5kVac EMC EMC / Emissions EN 55015 Class B; Compliance to CISPR 22, EN 55022, FCC Title 47: Class B Immunity to Compliance to EN 61547, EN 55024 1) Electrostatic Discharge IEC 61000-4-2 Radiated Field IEC 61000-4-3 Electrical Fast Transient / Burst IEC 61000-4-4 Surge IEC 61000-4-5 Level 5 Criteria B2) Common Mode3): 6kV 4) Differential Mode : 4kV Conducted IEC 61000-4-6 Level 3 Criteria A 150kHz-80MHz, 10Vrms Power Frequency Magnetic Fields IEC 61000-4-8 Level 3 Criteria A1) 10A/Meter Voltage Dips IEC 61000-4-11 Level 4 Criteria A Air Discharge: 15kV Contact Discharge: 8kV 1) Level 3 Criteria A 80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation Level 3 Criteria A1) 2kV 1) 100% dip; 0.5 cycle; Self Recoverable 70% dip; 10 cycle; Self Recoverable Harmonic Current Emission IEC/EN 61000-3-2, Class C (115Vac & 230Vac @ 50% load & 277Vac @ 75% load) Voltage Fluctuation and Flicker IEC/EN 61000-3-3 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Temporary degradation or loss of function which is self-recoverable 3) Asymmetrical: Common mode (Line to earth) 4) Symmetrical: Differential mode (Line to line) 7 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (May 2015, Rev. 00) TECHNICAL DATASHEET LED Driver LNE-150W Series / LNE-V150W Block Diagram LNE-V150WA LNE-V150WD 8 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (May 2015, Rev. 00) TECHNICAL DATASHEET LED Driver LNE-150W Series / LNE-V150W Dimensions L x W x D: 228 x 68 x 38.8 mm LNE-V150WA LNE-V150WD Item 9 Device Description 1 Input Cable 2 Output Cable 3 Vo Adjust (Constant Voltage Adjustment) 4 Io Adjust (Constant Current Adjustment) 5 Dimming Cable All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (May 2015, Rev. 00) TECHNICAL DATASHEET LED Driver LNE-150W Series / LNE-V150W Engineering Data De-rating Note 1. 2. 3. 4. Fig. 1 De-rating for Horizontal Mounting Orientation > 60C de-rate power by 4% / C Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. If the output capacity is not reduced when the surrounding air temperature >60C, the device will run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! If the device has to be mounted in any other orientation, please do not hesitate to contact info@deltapsu.com for more details. Output De-rating VS. Input Voltage 10 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (May 2015, Rev. 00) No output power de-rating for the input voltage from:100Vac to 277Vac (LNE-V150WC), 100Vac to 305Vac (LNE-V150WA) TECHNICAL DATASHEET LED Driver LNE-150W Series / LNE-V150W Assembly & Installation The device is not recommended to be placed on low thermal conductive surfaces. For example, plastics. Base Mounting (Horizontal) Fig. 2 Recommended Mounting Orientation Safety Instructions - - - - - - - - 11 ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the device. If mains are not turned OFF, there is risk of explosion / severe damage. To guarantee sufficient convection cooling, keep a distance of 50mm above and lateral distance to other units. DO NOT insert any objects into the device. Note that the enclosure of the device can become very hot depending on the surrounding air temperature and load of the device. Risk of burns! If the device is continuously operating in a mounting orientation other than those shown in Fig. 2. or at high ambient temperature outside the shaded region shown in Fig. 1., the device may be damaged or degraded. When the PE terminal is not connected, the device must be installed on a metal plate with PE connection. The current rating for the output cable must be rated higher than or equal to the output current of the power supply. Please refer to the product specifications. For device with dimming function, always ensure the dimming control is working properly. All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (May 2015, Rev. 00) TECHNICAL DATASHEET LED Driver LNE-150W Series / LNE-V150W Functions Start-up Time The time required for the output voltage to reach 90% of its set value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its set value. Hold-up Time Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time required for the output to reach 95% of its set value, after the input voltage is removed. Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Inrush Current Dynamic Response Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. The power supply output voltage will remain within 5% of its steady state value, when subjected to a dynamic load from 0 to 100% of its rated current. 90% Duty / 1KHz 90% Duty / 120Hz 12 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (May 2015, Rev. 00) TECHNICAL DATASHEET LED Driver LNE-150W Series / LNE-V150W Driving Methods of LED Modules A typical LED power supply is able to either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs. DELTA's LED driver integrate CV+ CC characteristic that can be operating at both CV mode (with external LED driver, at area and CC mode (direct drive, at area ). In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact with Delta. Dimming Operations This operation is available for LNE-V150WD only. The Dimming connection diagram for turning the lighting fixture ON/OFF can be configured as below. LNE-V150WD Please refer an example of reference configuration as follows. 1. 2. 13 Built-in 3 in 1 dimming function, IP67 rated. Output constant current level can be adjusted through output cable by connecting a resistance or 1~10Vdc or 10V PWM signal between DIM+ and DIM-. The LED lighting fixture can be turned ON/OFF by the switch. All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (May 2015, Rev. 00) TECHNICAL DATASHEET LED Driver LNE-150W Series / LNE-V150W 3. 4. 5. Please DO NOT connect "DIM-" to "V-". Reference resistance value for output current adjustment (Typical). Resistance 10K 20K 30K 40K 50K 60K 70K 80K 90K 100K Rated Current (%) 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 1 ~ 10V dimming function for output current adjustment (Typical). Dimming Value Rated Current (%) 6. 7. 14 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Please note that LNE-V150WD can't turn the lighting fixture totally dark. Please refer to the connection method above to achieve 0% brightness of the lighting fixture connecting to the LED power supply unit. It is recommended to directly connect to LEDs, but is not suitable for using additional drivers. All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (May 2015, Rev. 00) TECHNICAL DATASHEET LED Driver LNE-150W Series / LNE-V150W Overload & Overcurrent Protections Overvoltage Protection Initially, the power supply's Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current between 95% and 108% of IO (Max load). In such occurrence, the VO will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into ""CC mode mode" (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. The power supply's overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 6 under "Protections". The power supply should be latch. Over Temperature Protection Short Circuit Protection The power supply's output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in "Hiccup mode", as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. As mentioned above, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the de-rating graph. Others Delta RoHS Compliant Restriction of the usage of hazardous substances The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation for "Restriction of the use of certain hazardous substances in electrical and electronic equipment". This product conforms to this standard. PFC - Norm EN 61000-3-2 Line Current Harmonic content Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a specific application. 15 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (May 2015, Rev. 00) Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Delta Electronics: LNE-12V150WAAA LNE-36V150WAAA LNE-24V150WDAA LNE-54V150WDAA LNE-36V150WDAA LNE48V150WDAA LNE-48V150WAAA LNE-54V150WAAA LNE-24V150WAAA LNE-12V150WDAA