Timers GT3A Series GT3A Series -- Analog Timers Key features of the GT3A series include: * 4 selectable operation modes on each model * External start, reset, and pause inputs * Panel mount or socket mount * Large variety of timing functions * Power and output status indicating LEDs UL, c-uL Listed File No. E55996 GT3A-1 Operation GT3A-2 GT3A-3 Multi-mode Time Range 100 to 240V AC, 50/60Hz 12V DC 24V AC, 50/60Hz / 24V DC 125V AC/250V AC, 3A; 30V DC, 1A (resistive load) Contact Ratings Minimum Applicable Load 125V AC/250V AC, 5A; 30V DC, 5A (resistive load) 5V, 10mA (reference value) AF20 (100V AC): 85 to 264V AC AD24: 20.4 to 26.4V AC/21.6 to 26.4V DC D12: 10.8 to 13.2V DC Voltage Tolerance Timers Multi-mode with inputs (11 pins) 0.05s to 180 hours Rated Voltage G 0.2%, 10 msec (repeat, voltage, temperature) Error 10% maximum Specifications Setting Error Reset Time 60msec maximum Insulation Resistance 100M minimum Between power and output terminals: 2,000V AC, 1 minute Between contacts of different poles: 2,000V AC, 1 minute Between contacts of the same pole: 750V AC, 1 minute Dielectric Strength Power Consumption (approximate) Delayed SPDT Delayed SPDT + instantaneous SPDT Delayed DPDT Delayed DPDT 10.8VA (200V AC, 60Hz) 13.5VA (200V AC, 60Hz) 14.4VA (200V AC, 60Hz) 4.7VA (100V AC, 60Hz), 14.4VA (200V AC, 60Hz) 12VDC/1W 12VDC/1.1W 12VDC/0.8W 24VDC/0.7W 24VAC/1.2VA 24VDC/0.6W 24VAC/1.3VA 24VDC/0.6W 24VAC/1.3VA - Mechanical Life Electrical LIfe Weight (approximate) 10,000,000 operations minimum 5,000,000 operations minimum 50,000 operations minimum (rated load) 100,000 operations minimum (rated load) 63g Vibration Resistance 73g 79g Operating Temperature -10 to +50C Operating Humidity 45 to 85% RH Storage Temperature -30 to +80C Housing Color Gray www.idec.com 80g 100m/sec2 (approximate 10G) Operating extremes: 100m/sec2 (approximate 10G) Damage limits: 500m/sec2 (approximate 50G) Shock Resistance G-14 GT3A-4,-5,-6 GT3A Table of Contents Specifications -- G-14 Part Number List -- G-15 Timing Diagrams/Schematics -- G-16 Instructions: Setting Timer -- G-22 GT3 Accessories -- G-48 GT3 Instructions: Wiring Inputs -- G-50 GT3 Dimensions -- G-52 Timing Diagrams Overview -- G-4 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3A Series Part Number List Part Numbers: GT3A-1, -2, -3 Mode Of Operation Rated Voltage Code Time Range Output AF20: 100 to 240V AC (50/60Hz) A: ON-delay 1 B: Interval 1 C: Cycle 1 D: Cycle 3 AF20: 100 to 240V AC (50/60Hz) D12: 12V DC AD24: 24V AC (50/60Hz)/24V DC Contact Delayed SPDT 0.05s. to 180 hours 250V AC, 3A, 30V DC, 1A (resistive load) 240V AC, 5A, 24V DC, 5A (resistive load) Delayed SPDT + Instantaneous SPDT Delayed DPDT Complete Part No. 8-Pin 11-Pin GT3A-1AF20 GT3A-1EAF20 GT3A-2AF20 GT3A-2EAF20 GT3A-2D12 GT3A-2ED12 GT3A-2AD24 GT3A-2EAD24 GT3A-3AF20 GT3A-3EAF20 GT3A-3D12 GT3A-3ED12 GT3A-3AD24 GT3A-3EAD24 1. For wiring schematics and timing diagrams for GT3A-1, -2, -3, see pages G-16, G-17, or G-18 respectively. 2. For more details about time ranges, see instructions on page G-22. 3. For socket and accessory part numbers, see page G-48. Part Numbers: GT3A-4, -5, -6 Mode of Operation Rated Voltage Code A: ON-Delay 2 B: Cycle 2 C: Signal ON/OFF-Delay 1 D: Signal OFF-Delay 1 AF20: 100 to 240V AC (50/60Hz) D12: 12V DC AD24: 24V AC (50/60Hz)/24V DC A: One-Shot B: One-Shot ON-Delay C: One-Shot 2 D: Signal ON/OFF-Delay 3 4. 5. 6. 7. 8. AF20: 100 to 240V AC (50/60Hz) AD24: 24V AC (50/60Hz)/24V DC 0.05 seconds to 180 hours Output 250V AC, 5A, 24V DC, 5A (resistive load) Contact Delayed DPDT Input Start Reset Gate Complete Part No. A (11-pin) B (11-pin) GT3A-4AF20 GT3A-4EAF20 GT3A-4D12 GT3A-4ED12 GT3A-4AD24 GT3A-4EAD24 GT3A-5AF20 GT3A-5EAF20 GT3A-5AD24 GT3A-5EAD24 GT3A-6AF20 GT3A-6EAF20 GT3A-6AD24 GT3A-6EAD24 G Timers A: Interval 2 B: One-Shot Cycle C: Signal ON/OFF-Delay 2 D: Signal OFF-Delay 2 Time Range For wiring schematics and timing diagrams GT3A-4,-5,-6, see pages G-19, G-20, and G-21 respectively. For more details about time ranges, see instructions on page G-22. A (11-pin) and B (11-pin) differ in the way inputs are wired. For socket and accessory part numbers, see page G-48. For the timing diagrams overview, see page G-4. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-15 Timers GT3A Series Timing Diagrams/Schematics GT3A- 1 Timing Diagrams Delayed SPDT 8-Pin 4 5 3 6 11-Pin 5 4 6 7 8 3 (-) 2 8 1 POWER Operation Mode Selection Item ON-Delay 1 MODE A 7 (+) Terminal No. 2-7 (8p) Power (Power) 2-10 (11p) 5-8 (8p) (NC) 8-11 (11p) Delayed Contact 6-8 (8p) (NO) 9-11 (11p) (-) 9 10 2 1 11 (+) POWER Operation Set Time POWER Indicator OUT Timers G Item Interval 1 MODE B Terminal No. 2-7 (8p) Power (Power) 2-10 (11p) 5-8 (8p) (NC) 8-11 (11p) Delayed Contact 6-8 (8p) (NO) 9-11 (11p) Operation Set Time POWER Indicator OUT Item Cycle 1 (OFF first) MODE C Terminal No. 2-7 (8p) Power (Power) 2-10 (11p) 5-8 (8p) (NC) 8-11 (11p) Delayed Contact 6-8 (8p) (NO) 9-11 (11p) Operation Set Time POWER Indicator OUT Item Cycle 3 (ON first) MODE D Terminal No. 2-7 (8p) Power (Power) 2-10 (11p) 5-8 (8p) (NC) 8-11 (11p) Delayed Contact 6-8 (8p) (NO) 9-11 (11p) Operation Set Time POWER Indicator OUT G-16 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3A Series GT3A- 2 Timing Diagrams Delayed SPDT + Instantaneous SPDT 4 8-Pin 11-Pin 5 3 5 6 7 4 6 8 3 Operation Mode Selection (-) 2 8 1 POWER Item ON-Delay 1 MODE A 7 (+) Terminal No. 2-7 (8p) Power (Power) 2-10 (11p) 5-8 (8p) (NC) 8-11 (11p) Delayed Contact 6-8 (8p) (NO) 9-11 (11p) (-) 9 2 10 1 11 (+) POWER Operation Set Time Instan- (NC) 1-4 taneous Contact (NO) 1-3 POWER Indicator OUT Item MODE B 2-7 (8p) Power (Power) 2-10 (11p) 5-8 (8p) (NC) 8-11 (11p) Delayed Contact 6-8 (8p) (NO) 9-11 (11p) Operation Set Time G Timers Interval 1 Terminal No. Instan- (NC) 1-4 taneous Contact (NO) 1-3 POWER Indicator OUT Item Cycle 1 (OFF first) MODE C Terminal No. 2-7 (8p) Power (Power) 2-10 (11p) 5-8 (8p) (NC) 8-11 (11p) Delayed Contact 6-8 (8p) (NO) 9-11 (11p) Operation Set Time Instan- (NC) 1-4 taneous Contact (NO) 1-3 POWER Indicator OUT Item Cycle 3 (ON first) MODE D Terminal No. 2-7 (8p) Power (Power) 2-10 (11p) 5-8 (8p) (NC) 8-11 (11p) Delayed Contact 6-8 (8p) (NO) 9-11 (11p) Operation Set Time Instan- (NC) 1-4 taneous Contact (NO) 1-3 POWER Indicator OUT www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-17 Timers GT3A Series GT3A-3 Timing Diagrams Delayed DPDT 4 8-Pin 11-Pin 5 3 5 6 7 4 6 8 3 Operation Mode Selection (-) 2 8 1 POWER Item ON-Delay 1 MODE A 7 (+) Terminal No. 2-7 (8p) Power (Power) 2-10 (11p) 5-8 (8p) (NC) 1-4, 1-4, 8 -11(11p) Delayed Contact 1-3, 6-8 (8p) (NO)1-3, 9-11(11p) Indicator (-) 9 2 10 1 11 (+) POWER Operation Set Time POWER OUT Timers G Item Interval 1 MODE B Terminal No. 2-7 (8p) Power (Power) 2-10 (11p) 5-8 (8p) (NC) 1-4, 1-4, 8 -11(11p) Delayed Contact 1-3, 6-8 (8p) (NO)1-3, 9-11(11p) Operation Set Time POWER Indicator OUT Item Cycle 1 (OFF first) MODE C Terminal No. 2-7 (8p) Power (Power) 2-10 (11p) 1-4, 5-8 (8p) Delayed (NC) 1-4, 8 -11(11p) Contact 1-3, 6-8 (8p) (NO)1-3, 9-11(11p) Operation Set Time POWER Indicator OUT Item Cycle 3 (ON first) MODE D Terminal No. 2-7 (8p) Power (Power) 2-10 (11p) 5-8 (8p) (NC) 1-4, 1-4, 8 -11(11p) Delayed Contact 1-3, 6-8 (8p) (NO)1-3, 9-11(11p) Operation Set Time POWER Indicator OUT G-18 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3A Series GT3A-4 Timing Diagrams Delayed DPDT (A Type) (Contact Input) (Transistor Input) 5 6 7 4 9 2 Operation Mode Selection Reset Start Gate 8 ResetStartGate 3 (-) MODE A Input 6 Start Reset 5 7 4 (-) Note: T = Set time Ta = Shorter than set time T = T' + T" 6 7 8 3 9 2 Terminal No. 2-10 (POWER) (A) Start 2-6 5-7 (B)ON or L (A) Reset 2-7 6-7 (B)ON or L 4 8 3 10 1 11 (+) POWER Item Power ON-Delay 2 5 (B Type) 9 2 10 1 11 (+) POWER (-) 10 1 11 (+) POWER Operation Gate 2-5 (A) ON or L 1-4 Delayed 8-11(NC) Contact 1-3 9-11(NO) POWER Indicator OUT B Terminal No. 2-10 (POWER) (A) Start 2-6 5-7 (B)ON or L (A) Reset 2-7 6-7 (B)ON or L Gate 2-5 (A) ON or L 1-4 Delayed 8-11(NC) Contact 1-3 9-11(NO) POWER Indicator MODE C T T T T T T T Ta T T T T' Operation T'' T T T T T Input Signal ON/OFF-Delay 1 OUT Set Time Item Terminal No. Power 2-10 (POWER) (A) Start 2-6 5-7 (B)ON or L (A) Reset 2-7 6-7 (B)ON or L Gate 2-5 (A) ON or L 1-4 Delayed 8-11(NC) Contact 1-3 9-11(NO) POWER Indicator OUT Set Time T T Ta T MODE D Input Item Power Signal OFF-Delay 1 Terminal No. 2-10 (POWER) (A) Start 2-6 5-7 (B)ON or L 2-7 (A) Reset 6-7 (B)ON or L Ta T T Operation T T'' Ta Gate 2-5 (A) ON or L 1-4 Delayed 8-11(NC) Contact 1-3 9-11(NO) POWER Indicator Set Time www.idec.com G Operation Timers MODE Input Item Power Cycle 2 T" Note: While the gate input is on during time-delay operation, the POWER indicator flash rate slows down. T' Ta T Set Time OUT T Ta Ta T T' USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Ta G-19 Timers GT3A Series GT3A- 5 Timing Diagrams . Delayed DPDT (A Type) (Contact Input) (Transistor Input) 5 6 7 4 8 ResetStartGate 3 5 Reset Start Gate 1 (-) 11 Start Reset 6 2 1 POWER 11 MODE A Input Interval 2 Terminal No. 2-10 (POWER) (A) Start 2-6 5-7 (B)ON or L (A) Reset 2-7 6-7 (B)ON or L 8 2 10 (+) Note: T = Set time Ta = Shorter than set time T = T' + T" 9 1 (-) 11 10 (+) POWER POWER Item Power 7 3 9 (-) 6 4 8 3 10 (+) 5 7 4 9 2 Operation Mode Selection (B Type) Operation Gate 2-5 (A) ON or L 1-4 Delayed 8-11(NC) Contact 1-3 9-11(NO) POWER Indicator OUT T Set Time MODE B Input One-Shot Cycle T" T' Item Power Terminal No. 2-10 (POWER) (A) Start 2-6 5-7 (B)ON or L 2-7 Reset 6-7 (A) (B)ON or L Operation Gate 2-5 (A) ON or L 1-4 Delayed 8-11(NC) Contact 1-3 9-11(NO) POWER Indicator OUT T Set Time T T Ta Signal ON/OFF-Delay 2 MODE C Input Item Power Terminal No. 2-10 (POWER) (A) Start 2-6 5-7 (B)ON or L 2-7 Reset 6-7 (A) (B)ON or L T" T' T Operation Gate 2-5 (A) ON or L 1-4 Delayed 8-11(NC) Contact 1-3 9-11(NO) POWER Indicator OUT T Set Time T Ta T Item Power Signal OFF-Delay 2 MODE D Input Timers G Ta Terminal No. 2-10 (POWER) (A) Start 2-6 5-7 (B)ON or L (A) Reset 2-7 6-7 (B)ON or L Ta Ta T T' T" Ta Operation Gate 2-5 (A) ON or L 1-4 Delayed 8-11(NC) Contact 1-3 9-11(NO) POWER Indicator OUT Set Time G-20 www.idec.com T Ta Ta T T' T" USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3A Series GT3A- 6 Timing Diagrams Delayed DPDT (A Type) (Contact Input) (Transistor Input) 5 6 4 8 ResetStartGate 3 (-) 5 Reset Start Gate 6 3 10 1 11 (+) POWER A Input MODE 5 7 (-) 8 (-) Note: T = Set time Ta = Shorter than set time T = T' + T" 9 2 10 1 11 (+) POWER Terminal No. 2-10 (POWER) (A) Start 2-6 5-7 (B)ON or L 2-7 Reset 6-7 (A) (B)ON or L 7 3 9 2 6 4 8 Item Power One-Shot 1 Start Reset 4 9 2 Operation Mode Selection 7 (B Type) 10 1 11 (+) POWER Operation Gate 2-5 (A) ON or L 1-4 Delayed 8-11(NC) Contact 1-3 9-11(NO) POWER Indicator OUT Ta Set Time Ta T Ta B Terminal No. 2-10 (POWER) (A) Start 2-6 5-7 (B)ON or L 2-7 Reset 6-7 (A) (B)ON or L G Operation Timers MODE Input Item Power One-Shot ON-Delay T" T' Gate 2-5 (A) ON or L 1-4 Delayed 8-11(NC) Contact 1-3 9-11(NO) POWER Indicator OUT T Set Time T Ta T T One Shot 2 MODE C Input Item Power Terminal No. 2-10 (POWER) (A) Start 2-6 5-7 (B)ON or L (A) Reset 2-7 6-7 (B)ON or L T' T" Operation Gate 2-5 (A) ON or L 1-4 Delayed 8-11(NC) Contact 1-3 9-11(NO) POWER Indicator OUT T Set Time Ta T Signal ON/OFF-Delay 3 MODE D Input Item Power Terminal No. 2-10 (POWER) (A) Start 2-6 5-7 (B)ON or L 2-7 Reset 6-7 (A) (B)ON or L T" T' Operation Gate 2-5 (A) ON or L 1-4 Delayed 8-11(NC) Contact 1-3 9-11(NO) POWER Indicator Set Time www.idec.com OUT T T Ta T' T"' USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Ta Ta T G-21 Timers GT3A Series Instructions: Setting GT3A Series Timers POWER Indicator (flashes during time-delay period) Timed OUT Indicator Setting Knob Time Range Selector Operation Mode 1S, 10S, 10M, 10H Selector A, B, C, D A Dial Selector 0-1, 0-3, 0-6, 0-18 Step 1. Desired Mode of Operation For Timers Mode of Operation ON-delay 1 Interval 1 Cycle 1 Cycle 3 ON-delay 2 Cycle 2 Signal ON/OFF-delay 1 Signal OFF-delay 1 Interval 2 One-shot cycle Signal ON/OFF-delay 2 Signal OFF-delay 2 One-shot 1 One-shot ON-delay One-shot 2 Signal ON/OFF-delay 3 GT3A-1 GT3A-2 GT3A-3 Timers G GT3A-4 Select the desired mode of operation. GT3A-5 GT3A-6 Step 2. Desired Time Range Time Ranges Select the time range that contains the desired time period. 0.05 seconds to 1 second 0.05 seconds to 3 seconds 0.05 seconds to 6 seconds 0.15 seconds to 18 seconds 0.1 seconds to 10 seconds 0.3 seconds to 30 seconds 0.6 seconds to 60 seconds 1.8 seconds to 180 seconds 6 seconds to 10 minutes 18 seconds to 30 minutes 36 seconds to 60 minutes 108 seconds to 180 minutes 6 minutes to 10 hours 18 minutes to 30 hours 36 minutes to 60 hours 108 minutes to 180 hours Step 3. Selection Operation Mode Selector A B C D A B C D A B C D A B C D Dial Selector 0-1 0-3 0-6 0-18 0-1 0-3 0-6 0-18 0-1 0-3 0-6 0-18 0-1 0-3 0-6 0-18 Remarks The desired operation mode can be selected from the A, B, C, and D modes using the Operation Mode Selector. Change the operation mode from A to B, C, and D in turn by turning the operation mode selector clockwise using a flat screwdriver which is a maximum of 0.156" (4mm) wide. The selected mode is displayed in the window. Selection Time Range Selector Remarks 1S 10S The desired time range is selected by setting both Dial Selector and Time Range Selector. 10M 10H Selection Set the precise period of time desired by using the Setting Knob. G-22 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3D Series GT3D Series -- Digital Timers Key features of the GT3D series include: * Precise time setting using digital thumbwheel switches * Elapsed or time remaining LED display * 6 time ranges, 16 timing functions * Time delays up to 99.9 hours GT3D-2 GT3D-3 Operation System GT3D-8 Multi-mode. one-shot output Multi-mode Time Range 0.01s to 99.9 hours Rated Voltage 100 to 240V AC (50/60Hz), 24V AC (50/60Hz)/24V DC 125V AC/250V AC, 3A; 30V DC/1A (resistive load) Contact Ratings Delayed SPDT + instantaneous SPDT Contact Form Minimum Applicable Load 125V AC/250V AC, 5A; 30V DC/5A (resistive load) Delayed DPDT Delayed DPDT Delayed DPDT 5V, 10mA (reference value) AF20 (100-240V AC): 85 to 264V AC AD24 (AC): 20.4 to 26.4V AC AD24 (DC): 21.6 to 26.4V DC Voltage Tolerance G 0.3% 50ms (voltage, repeat, and temperature) Setting Error 0.5% 50ms Reset Time 60ms maximum 100M minimum Insulation Resistance Dielectric Strength AF20 AD24 AC/DC Between power and output terminals: 2,000V AC, 1 minute Between contacts of different poles: 2,000V AC, 1 minute Between contacts of the same pole: 750V AC, 1 minute 11.8VA 11.6VA 3.7VA (100V AC, 60Hz) 11.6VA (200V AC, 60Hz) 1VA/0.8W 2.1VA/0.9W 2.1VA /0.9W 10,000,000 operations minimum 5,000,000 operations minimum Electrical Life (at rated load) 50,000 operations minimum 100,000 operations minimum Outputs 250V AC, 3A, 30V DC, 1A (resistive load) 240V AC/, 24V DC, 5A (resistive load) Mechanical Life Relay Vibration Resistance 100N (approximate 10G) Operating extremes: 100N (approximate 10G) Damage limits: 500N (approximate 50G) Shock Resistance Operating Temperature -10 to +50C Storage Temperature -30 to +80C Operating Humidity 45 to 85% RH Weight (approximate) Housing Color www.idec.com Timers Error Specifications GT3D-4 Solid state CMOS circuitry Operation Power Consumption (approximate) Cert. No. BL9801133323911 (LVD) E9971113332388 (EMC) CSA Certified File No.LR58183 LR96764 LR83814 UL Recognized File No.E55996 70g 75g Gray 76g GT3D Table of Contents Specifications -- G-23 Part Number List -- G-24 Timing Diagrams/ Schematics -- G-25 Instructions: Setting Timer -- G-33 GT3 Accessories -- G-48 GT3 Instructions: Wiring Inputs -- G-50 GT3 Dimensions -- G-52 Timing Diagrams Overview -- G-4 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-23 Timers GT3D Series Part Number List Part Numbers: GT3D-1/GT3D-2/GT3D-3 Time Range Mode of Operation 1-A: ON-delay 1 1-B: Interval 1 first 1-C: Cycle 1 (OFF first) 1-D: Cycle 3 (ON first) 0.01s to 99.9 hours Output Contact 250V AC, 3A, 30V DC, 1A (resistive load) Delayed SPDT + instantaneous SPDT 240V AC/, 24V DC, 5A (resistive load) Delayed DPDT Rated Voltage Code Complete Part No. 8-Pin 100 to 240V AC (50/60Hz) GT3D-2AF20 24V AC/DC GT3D-2AD24 100 to 240V AC (50/60Hz) GT3D-3AF20 24V AC/DC GT3D-3AD24 11-Pin GT3D-2EAF20 -- GT3D-3EAF20 -- Part Numbers: GT3D-4 Time Range Mode of Operation Timers G 1-A: ON-delay 1 1-B: Interval 1 first 1-C: Cycle 1 (OFF first) 1-D: Cycle 3 (ON first) 2-A: ON-delay 2 2-B: Cycle 2 2-C: Signal ON/OFF-delay 1 2-D: Signal OFF-delay 1 2-E: Interval 2 2-F: One-shot cycle 3-A: Signal ON/OFF-delay 2 3-B: Signal OFF-delay 2 3-C: One-shot 1 3-D: One-shot ON-delay 3-E: One-shot 2 3-F: Signal ON/OFF-delay 3 0.01s to 99.9 hours Part Numbers: GT3D-8 Mode of Time Operation Range 1: ON-delay one-shot 1 2: Cycle one-shot 3: ON-delay one-shot 2 1. 2. 3. 4. 5. G-24 0.01s to 99.9 hours Output 240V AC/24V DC, 5A (resistive load) Output 240V AC/24V DC, 5A (resistive load) Contact Rated Voltage Code Complete Part No. A (11-pin) B (11-pin) 100 to 240V AC (50/60Hz) GT3D-4AF20 24V AC/DC GT3D-4AD24 GT3D-4EAF20 Delayed DPDT Contact Rated Voltage Code -- Complete Part No. (11-pin) 100 to 240V AC (50/60Hz) GT3D-8AF20 24V AC/DC GT3D-8AD24 Delayed DPDT For wiring schematics and timing diagrams GT3D, see pages G-25 to G-32. For more details about time ranges, see instructions on page G-33. A (11-pin) and B (11-pin) differ in the way inputs are wired. For socket and accessory part numbers, see page G-48. For timing diagrams overview, see page G-4. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3D Series GT3D-2 Timing Diagrams Delayed SPDT + Instantaneous SPDT Contact 8-Pin 4 5 3 6 11-Pin 5 4 6 7 8 3 (-) 2 7 (+) 2 (-) 1 -- A Time Elapsed 1 -- A Terminal No. (8p) Power (Power) 2-7 2-10 (11p) 1-4, 5-8 (8p) Delayed (NC) 1-4, 8-11 (11p) Contact 6-8 (8p) (NO) 1-3, 1-3, 9-11 (11p) 1 -- B Time Elapsed 1 -- B Indicator OUT Digital Time Display DOWN UP Terminal No. (8p) Power (Power) 2-7 2-10 (11p) 1-4, 5-8 (8p) Delayed (NC) 1-4, 8-11 (11p) Contact 6-8 (8p) (NO) 1-3, 1-3, 9-11 (11p) Time Remaining 1 -- C Time Elapsed 1 -- C Operation Set Time G Instan- (NC) 1-4 taneous Contact (NO) 1-3 Indicator OUT Digital Time Display DOWN Item Cycle 1 (OFF first) Operation Set Time Timers Time Remaining (+) Instan- (NC) 1-4 taneous Contact (NO) 1-3 Item Interval 1 11 POWER Item Time Remaining 10 1 8 1 POWER ON-Delay 1 9 UP Terminal No. (8p) Power (Power) 2-7 2-10 (11p) 1-4, 5-8 (8p) Delayed (NC) 1-4, 8-11 (11p) Contact 6-8 (8p) (NO) 1-3, 1-3, 9-11 (11p) Set Time Operation Instan- (NC) 1-4 taneous Contact (NO) 1-3 Indicator OUT Digital Time Display UP DOWN Item Cycle 3 (ON first) Time Remaining 1 -- D Time Elapsed 1 -- D www.idec.com Terminal No. Operation Set Time 2-7 (8p) Power (Power) 2-10 (11p) 1-4, 5-8 (8p) Delayed (NC) 1-4, 8-11 (11p) Contact 6-8 (8p) (NO) 1-3, 1-3, 9-11 (11p) Instan- (NC) 1-4 taneous Contact (NO) 1-3 Indicator OUT Digital Time Display UP DOWN USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-25 Timers GT3D Series GT3D-3 Timing Diagrams Delayed DPDT Contact 8-Pin 4 5 3 6 11-Pin 5 4 6 7 8 3 (-) 2 7 (+) Operation Mode Selection Item ON-Delay 1 Time Remaining 1 -- A Time Elapsed 1 -- A Timers G Time Remaining 1 -- B Time Elapsed 1 -- B Indicator OUT Digital Time Display DOWN Time Remaining 1 -- C Time Elapsed 1 -- C Cycle 3 (ON first) Time Remaining 1 -- D Time Elapsed 1 G-26 -- D Terminal No. Indicator OUT Digital Time Display DOWN 10 1 11 (+) POWER Operation Set Time Operation Set Time UP Terminal No. 2-7 (8p) Power (Power) 2-10 (11p) 5-8 (8p) (NC) 1-4, 1-4, 8-11 (11p) Delayed Contact (NO) 1-3, 6-8 (8p) 1-3, 9-11 (11p) Indicator OUT Digital Time Display DOWN Item 2 UP 2-7 (8p) Power (Power) 2-10 (11p) 5-8 (8p) (NC) 1-4, 1-4, 8-11 (11p) Delayed Contact (NO) 1-3, 6-8 (8p) 1-3, 9-11 (11p) Item Cycle 1 (OFF first) Terminal No. 2-7 (8p) Power (Power) 2-10 (11p) 1-4, 5-8 (8p) Delayed (NC) 1-4, 8-11 (11p) Contact 6-8 (8p) (NO) 1-3, 1-3, 9-11 (11p) Item Interval 1 (-) 8 1 POWER 9 Operation Set Time UP Terminal No. 2-7 (8p) Power (Power) 2-10 (11p) 1-4, 5-8 (8p) Delayed (NC) 1-4, 8-11 (11p) Contact 6-8 (8p) (NO) 1-3, 1-3, 9-11 (11p) Indicator OUT Digital Time Display DOWN Operation Set Time UP www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3D Series GT3D-4 Timing Diagrams These timers require a start input. A gate and reset input are optional. Inputs are controlled by external pushbuttons. Reset occurs when the power is removed or when the reset input is supplied. The gate signal can be used to interrupt (freeze) timer functions. Timer functions resume when the gate input is removed. B style timers are not equipped for gate input. GT3D-4 Delayed DPDT (A Type) (Contact Input) (Transistor Input) 6 5 7 4 8 ResetStartGate 3 (-) Start Reset 5 6 7 3 5 (+) (-) A Time Elapsed 1 -- A Terminal No. GT3D-4 Power 2-10 (POWER) (NC) 1-4 8-11 8-11 Delayed Contact 1-3 (NO) 9-11 9-11 Indicator OUT Digital Time Display DOWN 1 -- B Time Elapsed 1 -- B T Terminal No. GT3D-4 Power 2-10 (POWER) (NC) 1-4 8-11 8-11 Delayed Contact 1-3 (NO) 9-11 9-11 Indicator OUT Digital Time Display DOWN Set Time www.idec.com G (+) Operation Item Time Remaining 11 UP Set Time Interval 1 1 Timers -- 9 10 POWER Item 1 8 2 POWER Time Remaining 7 3 10 11 6 4 9 2 ON-Delay 1 10 1 11 (+) POWER (-) 8 1 9 2 (Transistor Input) Start Reset 4 (-) 8 3 10 1 11 (+) POWER (B Type) (Contact Input) 7 4 9 2 6 5 Reset Start Gate Operation UP T USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-27 Timers GT3D Series GT3D-4 Timing Diagrams, continued Item Terminal No. GT3D-4 Power 2-10 (POWER) 1-4 (NC) 8-11 8-11 Delayed Contact 1-3 (NO) 9-11 9-11 Cycle 1 (OFF first) Time Remaining 1 -- C Indicator OUT Digital Time Display DOWN Operation Time Elapsed 1 -- C UP Set Time T T T T T Item Terminal No. GT3D-4 Power 2-10 (POWER) (NC) 1-4 8-11 8-11 Delayed Contact 1-3 (NO) 9-11 9-11 Cycle 3 (ON first) Time Remaining 1 -- D Time Elapsed G -- D Timers 1 Indicator OUT Digital Time Display DOWN Operation UP Set Time Item Input Power ON-Delay 2 Time Remaining 2 -- A Time Elapsed 2 -- A T T T T Terminal No. GT3D-4 2-10 (POWER) (A) Start ON or L 2-6 5-7 (B) (A) Reset ON or L 2-7 6-7 (B) T T Operation 3-6 3-7 Gate ON or L 2-5 (A) 3-5 1-4 (NC) 8-11 8-11 Delayed Contact 1-3 (NO) 9-11 9-11 Indicator OUT Digital Time Display DOWN Set Time G-28 T www.idec.com UP T Ta T' T' USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3D Series GT3D-4 Timing Diagrams, continued Terminal No. GT3D-4 2-10 (POWER) Power (A) Start ON or L 2-6 5-7 (B) 3-6 (A) Reset ON or L 2-7 6-7 (B) 3-7 Operation Input Item Cycle 2 Time Remaining 2 -- B Time Elapsed 2 -- B Gate ON or L 2-5 (A) 3-5 (NC) 1-4 8-11 8-11 Delayed Contact 1-3 (NO) 9-11 9-11 Indicator OUT Digital Time Display DOWN UP Set Time Item T T T T T T T Ta Terminal No. GT3D-4 T T T T T' T'' T T Operation Signal ON/OFF-Delay 1 Time Remaining 2 -- C Time Elapsed -- C 2-10 (POWER) 2-6 Start ON or L 5-7 (A) (B) 3-6 2-7 Reset ON or L 6-7 (A) (B) 3-7 Gate ON or L 2-5 (A) 3-5 (NC) 1-4 8-11 8-11 Delayed Contact 1-3 (NO) 9-11 9-11 Indicator OUT Digital Time Display DOWN G Timers 2 Input Power UP Set Time T T Ta T Ta Ta Operation Ta T T' Operation Signal OFF-Delay 1 Time Remaining 2 -- D Time Elapsed 2 -- D Terminal No. GT3D-4 Power 2-10 (POWER) (A) Start ON or L 2-6 5-7 (B) 3-6 (A) Reset ON or L 2-7 6-7 (B) 3-7 Indicator OUT Digital Time Display Set Time DOWN T'' Ta UP T Ta T'' Input Terminal No. GT3D-4 Power 2-10 (POWER) (A) Start ON or L 2-6 5-7 (B) 3-6 (A) Reset ON or L 2-7 6-7 (B) 3-7 Interval 2 Time Remaining -- E Time Elapsed 2 T' Gate ON or L 2-5 (A) 3-5 (NC) 1-4 8-11 8-11 Delayed Contact 1-3 (NO) 9-11 9-11 Item 2 T Input Item -- E www.idec.com Gate ON or L 2-5 (A) 3-5 (NC) 1-4 8-11 8-11 Delayed Contact (NO) 1-3 9-11 9-11 Indicator OUT Digital Time Display Set Time DOWN UP T Ta T' T'' USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-29 Timers GT3D Series GT3D-4 Timing Diagrams, continued One-Shot Cycle Time Remaining 2 -- F Time Elapsed 2 -- F Terminal No. GT3D-4 Power 2-10 (POWER) (A) Start ON or L 2-6 5-7 (B) 3-6 (A) Reset ON or L 2-7 6-7 (B) 3-7 Operation Input Item Gate ON or L 2-5 (A) 3-5 (NC) 1-4 8-11 8-11 Delayed Contact 1-3 (NO) 9-11 9-11 Indicator OUT Digital Time Display DOWN UP Set Time T T T Ta Signal ON/OFF-Delay 2 Time Remaining 3 G -- A Time Elapsed -- A Timers 3 Terminal No. GT3D-4 Power 2-10 (POWER) (A) Start ON or L 2-6 5-7 (B) 3-6 (A) Reset ON or L 2-7 6-7 (B) 3-7 Indicator OUT Digital Time Display DOWN 3 -- B Time Elapsed 3 -- B T Ta T Ta Ta Operation T Indicator OUT Digital Time Display DOWN C Time Elapsed Ta T Ta T Operation T' T'' C Gate ON or L 2-5 (A) 3-5 (NC) 1-4 8-11 8-11 Delayed Contact 1-3 (NO) 9-11 9-11 Indicator OUT Digital Time Display DOWN Set Time G-30 T Input Time Remaining -- T'' UP Terminal No. GT3D-4 Power 2-10 (POWER) (A) Start ON or L 2-6 5-7 (B) 3-6 (A) Reset ON or L 2-7 6-7 (B) 3-7 One-Shot 1 3 T' Gate ON or L 2-5 (A) 3-5 (NC) 1-4 8-11 8-11 Delayed Contact 1-3 (NO) 9-11 9-11 Item -- T Input Terminal No. GT3D-4 Power 2-10 (POWER) (A) Start ON or L 2-6 5-7 (B) 3-6 (A) Reset ON or L 2-7 6-7 (B) 3-7 Set Time 3 T UP Item Time Remaining T'' Gate ON or L 2-5 (A) 3-5 (NC) 1-4 8-11 8-11 Delayed Contact 1-3 (NO) 9-11 9-11 Set Time Signal OFF-Delay 2 T' Operation Input Item www.idec.com UP Ta Ta T Ta T' T'' USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3D Series GT3D-4 Timing Diagrams, continued One-Shot ON-Delay Time Remaining 3 -- D Time Elapsed 3 -- D Terminal No. GT3D-4 Power 2-10 (POWER) (A) Start ON or L 2-6 5-7 (B) 3-6 (A) Reset ON or L 2-7 6-7 (B) 3-7 Operation Input Item Gate ON or L 2-5 (A) 3-5 (NC) 1-4 8-11 8-11 Delayed Contact 1-3 (NO) 9-11 9-11 Indicator OUT Digital Time Display DOWN UP Set Time T T Ta T T Terminal No. GT3D-4 Power 2-10 (POWER) (A) Start ON or L 2-6 5-7 (B) 3-6 (A) Reset ON or L 2-7 6-7 (B) 3-7 One Shot 2 Time Remaining 3 -- E -- E Gate ON or L 2-5 (A) 3-5 (NC) 1-4 8-11 8-11 Delayed Contact 1-3 (NO) 9-11 9-11 Indicator OUT Digital Time Display DOWN G UP Set Time T Ta T Signal ON/OFF-Delay 3 Time Remaining -- F Time Elapsed 3 -- F Terminal No. GT3D-4 Power 2-10 (POWER) (A) Start ON or L 2-6 5-7 (B) 3-6 (A) Reset ON or L 2-7 6-7 (B) 3-7 T'' Gate ON or L 2-5 (A) 3-5 (NC) 1-4 8-11 8-11 Delayed Contact 1-3 (NO) 9-11 9-11 Indicator OUT Digital Time Display DOWN UP Set Time www.idec.com T' Operation Input Item 3 T'' Timers Time Elapsed 3 T' Operation Input Item T T Ta Ta Ta T' T'' USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Ta G-31 Timers GT3D Series GT3D-8 Timing Diagrams Delayed DPDT (Transistor Input) (Contact Input) 5 6 7 4 ResetStartGate 3 5 Reset Start Gate 8 4 (-) 10 1 11 (+) POWER Item Terminal No. Power 2-10 (POWER) Note: T = Set time Ta = Shorter than set time Tb = Shorter than single-shot output time T = T' + T" T0 = Single-shot output time (selected from A, B, C, D, E or F) 7 8 3 9 2 6 9 2 (-) 10 1 11 (+) POWER Operation ON-Delay One-Shot 1 Time Remaining 1 Time Elapsed 1 Input Start ON or L 2-6 Reset ON or L 2-7 Gate ON or L 2-5 (NC) 1-4 8-11 Delayed Contact (NO) 1-3 9-11 Indicator OUT G Timers Digital Time Display DOWN UP Set Time T Item Terminal No. Power 2-10 (POWER) To Ta T Tb T' T'' To T Tb Operation Input Start ON or L 2-6 Cycle One-Shot Time Remaining 2 Time Elapsed 2 Reset ON or L 2-7 Gate ON or L 2-5 1-4 (NC) 8-11 Delayed Contact 1-3 (NO) 9-11 Indicator OUT Digital Time Display DOWN UP Set Time T Item Terminal No. Power 2-10 (POWER) To T To T Ta To T Tb T T'' Ta To T' To Operation ON-Delay One-Shot 2 Time Remaining 3 Time Elapsed 3 Input Start ON or L 2-6 Reset ON or L 2-7 Gate ON or L 2-5 1-4 (NC) 8-11 Delayed Contact 1-3 (NO) 9-11 Indicator OUT Digital Time Display DOWN UP Set Time G-32 www.idec.com T To Ta T Tb Ta T Tb T' T'' Tb USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3D Series Instructions: Setting GT3D-2, GT3D-3 Timers Timed OUT Indicator Time Setting Digital Switch Digital Time Display (LCD backlit with red LED) Indication Mode Time Range Selector Selector 1 9.99S - 99.9H 1 Operation Mode Selector A, B, C, D Step 1 Step 2 Time elapsed 1 Time remaining 1 Time elapsed 1 Time remaining 1 Time elapsed 1 Time remaining 1 Time elapsed 1 Time remaining 1 Step 3 Operation Mode Selector A ON-delay 1 B 2. The Indicator Mode Selector determines whether the Digital Time Display shows the time elapsed or time remaining. The Operation Mode Selector determines the desired operation mode. Decide which display and mode is desired, then use these two selectors to set the operation mode. C Cycle 1 C 3. The Operation Mode Selector has two blank modes which are not intended for use. Always have this selector set to A, B, C, or D. D Cycle 3 Desired Operation D Selection Remarks Time Range 1. The Time Range Selector controls both the decimal point indicator (9.99, 99.9, 999) and the time increment indicators S (seconds), M (minutes), and H (hours). Selector Decimal Point Time Increment Indicator Indicator 0.01 seconds to 9.99 seconds 0.1 seconds to 99.9 seconds 1 second to 999 seconds 0.1 minutes to 99.9 minutes 9.99 99.9 999 99.9 1 minute to 999 minutes 999 M 0.1 hours to 99.9 hours 99.9 H Desired Operation A 1. Use the flat screwdriver to set the selectors. Since selectors do not turn all the way around, both clockwise and counterclockwise rotation may be necessary. B Interval Base Time Ranges Select a time range that contains the desired period of time. Remarks S Selection Set the precise period of time desired by using the Time Setting Digital Switch. 2. Chose which base time range contains the targeted timer setting. Then use the Time Range Selector to set the decimal point indicator and time increment indicator to its corresponding pair of settings. 3. Since these configurations offer a complete range of settings from 0.01 seconds to 99.9 hours, the setting of 9.99 for minutes and the 9.99 and 999 settings for hours are not listed and should not be used. Remarks Use the Time Setting Digital Switch to set the desired period of time. It is important to remember that the setting of the Time Range Selector determines the units of time measurement as well as the implied decimal point location. It is important to remember that the Time Range Selector not only selects the time range but also influences the interpretation of the Digital Time Display. Changing the Time Range Selector setting changes the units of time measurement (seconds, minutes, hours) as well as the decimal point location. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-33 G Timers Select the desired time display and operation modes. Desired Mode/Selection Time Indicator Mode Operation Display Selector Mode Mode Timers GT3D Series Instructions: Setting GT3D-4 Timers Timed OUT Indicator Time Setting Digital Time Display (LCD backlit with Red LED) Digital Switch Operation Mode Time Range Selector Selector/Indication Mode Selector 9.99S - 99.9H Operation Mode Selector A, B, C, D, E, F Step 1 Desired Mode/Selection Time Display Mode Timers G Select the desired time display and operation modes. Step 2 Indicator Mode Selector Time elapsed 1 Time remaining 1 Time elapsed 2 Time remaining 2 Time elapsed 3 Time remaining 3 Selector ON-delay 1 Interval 1 Cycle 1 D: Cycle 3 A B C D ON-delay 2 Cycle 2 Signal ON/OFF-delay 2 Signal OFF-delay 1 Interval 2 One-shot cycle Signal ON/OFF-delay 2 Signal OFF-delay 2 One-shot 1 One-shot ON-delay One-shot 2 Signal ON/OFF-delay 3 A B C D E F A B C D E F 3. When using the indicator mode setting "1," the Operation Mode Selector has two blank modes which are not intended for use. When using mode setting "1," always have the operation mode selector set to A, B, C, or D. 0.01 seconds to 9.99 seconds 0.1 seconds to 99.9 seconds 1 seconds to 999 seconds 0.1 minutes to 99.9 minutes 9.99 99.9 999 99.9 S 1 minute to 999 minutes 999 M 0.1 hours to 99.9 hours 99.9 H Desired Operation Selection Select the desired period of time by using the Time Setting Digital Switch. 1. Use a flat screwdriver to set the selectors. Since selectors do not turn all the way around, both clockwise and counterclockwise rotation is necessary. 2. The Indicator Mode Selector determines whether the Digital Time Display shows the time elapsed or time remaining. The Operation Mode Selector determines the desired operation mode. Decide which display and mode is desired; then use these two selectors to set the operation mode. Selection Time Range Selector Decimal Point Time Increment Indicator Indicator Base Time Ranges Step 3 Operation Mode Operation Mode Desired Operation Select a time range that contains the desired period of time. Remarks Remarks 1. The Time Range Selector controls both the decimal point indicator (9.99, 99.9, 999) and the time increment indicator: S (seconds), M (minutes), and H (hours). 2. Choose the base time range which contains the targeted timer setting. Then use the Time Range Selector to set the decimal point indicator and time increment indicator to its corresponding pair of settings. 3. Since these configurations offer a complete range of settings from 0.01 seconds to 99.9 hours, the setting of 9.99 for minutes and the 9.99 and 999 settings for hours are not listed and should not be used. Remarks Use the Time Setting Digital Switch to set the desired period of time. It is important to remember that the setting of the Time Range Selector determines the units of time measurement as well as the implied decimal point location. It is important to remember that the Time Range Selector not only selects the time range, but also influences the interpretation of the Digital Time Display. Changing the Time Range Selector setting changes the units of time measurement (seconds, minutes, hours) as well as the implied decimal point location. G-34 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3D Series Instructions: Setting GT3D-8 Timers Timed OUT Indicator Time Setting Digital Switch Digital Time Display (LCD backlit with Red LED) Time Range Selector Indication Mode 9.99S - 99.9H Selector 1 1 Single-Shot Output Time Selector A, B, C, D, E, F Step 1 Desired Mode of Operation Operation Mode Time Display Mode Selection Indicator Mode Selector Time elapsed 1 1. Use a flat screwdriver to set the selectors. Since selectors do not turn all the way around, both clockwise and counterclockwise rotation is necessary. ON-Delay One-Shot Select the time display and operation modes. Remarks 1 Time elapsed 2 Time remaining 2 Time elapsed 3 Time remaining 3 2. The GT3D-8 Indicator Mode Selector selects both whether the Digital Time Display displays the time elapsed or time remaining and also the mode of operation. Decide which display and mode is desired. Then use this selector to set the operation mode. Cycle one-shot ON-delay one-shot 2 Step 2 Select the single shot output time. Step 3 Desired Mode of Operation Desired Single-Shot Output Time Single-Shot Output Time Selector 0.1 seconds 0.5 seconds 1 second 5 seconds 10 seconds 50 seconds A B C D E F Desired Mode of Operation Base Time Ranges Select the time range that contains the desired period of time. Step 4 Selection Selection Remarks Time Range Selector 1. The Time Range Selector controls both the decimal point indicator (9.99, 99.9, 999) and the time increment indicator: S (seconds), M (minutes), and H (hours). Time Increment Indicator 0.01 seconds to 9.99 seconds 0.1 seconds to 99.9 seconds 1 second to 999 seconds 0.1 minutes to 99.9 minutes 9.99 99.9 999 99.9 S 1 minute to 999 minutes 999 M 0.1 hours to 99.9 hours 99.9 H Desired Mode of Operation Remarks On the GT3D-8 timers, the desired single-shot output time can be selected from the A, B, C, D, E, and F modes using the One-Shot Output Time Selector. Decimal Point Indicator Selection Select the desired period of time by using the Time Setting Digital Switch. 2. Chose which base time range contains the targeted timer setting. Then use the Time Range Selector to set the decimal point indicator and time increment indicator to its corresponding pair of settings. 3. Since these configurations offer a complete range of settings from 0.01s to 99.9 hours, the setting of 9.99 for minutes and the 9.99 and 999 settings for hours are not listed and should not be used. Remarks Use the Time Setting Digital Switch to set the desired period of time. It is important to remember that the setting of the Time Range Selector selects the units of time measurement as well as the implied decimal point location. It is important to remember that the Time Range Selector not only selects the time range, but also influences the interpretation of the Digital Time Display. Changing the Time Range Selector setting changes the units of time measurement (seconds, minutes, hours) as well as the decimal point location. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G Timers Time remaining G-35 Timers GT3F Series GT3F Series -- True OFF Delay Timers Key features of the GT3F series include: * Mountable in sockets or flush panel * "True" power OFF-delay up to 10 minutes * No external control switch necessary * Available with reset inputs UL, c-uL Listed File No. E55996 GT3F-2 Time Range 0.05 seconds to 600 seconds Rated Voltage 100 to 240V AC, 50/60Hz 24V AC/DC Contact Rating 250V AC/30V DC, 5A (resistive load) 250V AC/30V DC, 3A (resistive load) Contact Form SPDT DPDT G Minimum Power Application Time 1 second Voltage Tolerance AF20: 100 to 240V AC AD24: 21.6 to 26.4VDC, 20.4 to 26.4VAC Repeat Error 0.2%, 10 msec Voltage Error 0.2%, 10 msec Temperature Error 0.2%, 10 msec Setting Error 10% maximum Insulation Resistance 100M minimum Dielectric Strength Between power and output terminals: 2,000V AC, 1 minute (SPDT) 1,500V AC, 1 minute (DPDT) Between contacts on different poles: 1,000V AC, 1 minute (DPDT) Between contacts of the same pole: 750V AC, 1 minute Power Consumption AF20: 3.7VA (200V AC, 60Hz) AD24: 0.8W (DC), 1.2VA (AC) Mechanical Life 20,000,000 operations minimum Electrical Life 100,000 operations minimum Vibration Resistance 100m/sec2 (approximate 10G) Shock Resistance Operating extremes: 100 m/sec2 (approximate 10G) Damage limits: 500 m/sec2 (approximate 50G) Operating Temperature -10 to +50C Storage Temperature -30 to +80C Operating Humidity 45 to 85% RH Weight (approximate) 77g Specifications True power OFF-delay Timers GT3F-1 Operation 79g 1. An inrush current flows during the minimum power application time. AF20: approximate 0.3A, AD24: approximate 0.6A 2. GT3F does not read the preset time range shown on the knob after power is turned off. Note that minimizing the preset time, by turning the knob to zero, does not shorten the delay time after power is removed. G-36 www.idec.com GT3F Table of Contents Specifications -- G-36 Part Number List -- G-37 Timing Diagrams/Schematics -- G-37 Instructions: Setting Timer -- G-39 Instructions: Wiring Inputs -- G-40 GT3 Accessories -- G-48 GT3 Instructions -- G-50 GT3 Dimensions -- G-52 Timing Diagrams Overview -- G-4 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3F Series Part Numbering List Part Numbers: GT3F Mode of Operation Time Range Rated Voltage Code 0.05 seconds to 600 seconds AF20: 100 to 240VAC (50/60Hz) Power OFF-delay AD24: 24V AC/DC Output Complete Part Number Optional Input Contact 250V AC, 5A, 30V DC, 5A (resistive load) Delayed SPDT Reset 250V AC, 3A, 30V DC, 3A (resistive load) Delayed DPDT None (8p) Reset (11p) 8-Pin 11-Pin GT3F-1AF20 GT3F-1EAF20 GT3F-1AD24 GT3F-1EAD24 GT3F-2AF20 GT3F-2EAF20 GT3F-2AD24 GT3F-2EAD24 1. Optional reset input resets the contact to the OFF state before time out. Timing Diagrams/Schematics GT3F-1 Timing Diagrams GT3F-1 (8-pin) GT3F-1E (11-pin) Delayed SPDT Output, with Reset Input 3 6 2 7 Reset 6 2 7 5 Reset (-) Item 3 8 1 POWER (+) (-) Terminal No. 7 4 Reset 8 3 (+) 8 1 POWER 6 10 1 11 (+) POWER 3 7 8 9 2 (-) 6 10 1 11 (+) POWER Operation 2-7 (8p) Power (Power) 2-10 (11p) Reset (ON or L) 1-4 (8p) In put 6-7 (11p) 5-8 (8p) (NC) 1-4 (11p) Delayed Contact (8p) (NO) 6-8 1-3 (11p) Indicator POWER Set Time 4 9 2 (-) 5 Reset T = Set Time Ta = Shorter than Set Time Ts = 1 Second Tr = Minimum Power Application Time * GT3F-1: 1 Second Tr T Ta Ts T 2. For time ranges, see page G-39. 3. For sockets and accessory part numbers, see page G-48. 4. When power is applied, the NO output contact closes. When power is removed, the timing period begins. When time has elapsed, the NO contact opens. 5. For the timing diagram overview, see page G-4. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-37 Timers (Contact Input) 4 5 G (Transistor Input) (Contact Input) (Transistor Input) 4 5 Timers GT3F Series GT3F-2 Timing Diagrams GT3F-2 (8-pin) GT3F-2E (11-pin) Delayed DPDT Output (Transistor Input) (Contact Input) 4 5 3 5 6 (-) 2 Reset 7 (+) 8-Pin Type Item 5 Reset 4 10 1 11 (+) POWER 9 2 (-) 7 8 3 9 6 10 1 11 (+) POWER Operation Power (Power) 2-7 1-4 Delayed (NC) 5-8 Contact (NO) 1-3 6-8 Indicator 8 3 (-) Terminal No. 7 4 2 8 1 POWER 6 T = Set Time Tr = Minimum Power Application Time: 1 Second POWER Set Time T Tr T Timers G 11-Pin Type Item Terminal No. Operation Power (Power) 2-10 Reset (ON or L) 6-7 (11p) In put 1-4 (NC) 8-11 Delayed Contact (NO) 1-3 9-11 POWER Indicator T = Set Time Ta = Shorter than Set Time Ts = 1 Second Tr = Minimum Power Application Time: 1 Second Tr Set Time T Ta Ts T When power is applied, the NO contact closes. When power is removed, the timing period begins. When time has elapsed, the NO contact opens. Optional reset input will return contacts to original state before time elapses. G-38 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3F Series Instructions: Setting GT3F Timers POWER Indicator Setting Knob Time Range Selector 1S, 10S Dial Selector 0-1, 0-3, 0-6, 0-18, 0-60 Steps 1. Select a time range that contains the desired period of time. Desired Operation Selection Dial Selector 0.05s to 1s 0 to 1 0.05s to 3s 0 to 3 0.05s to 6s 0 to 6 0.1s to 10s 0 to 1 0.3s to 30 0 to 3 0.6s to 60 0 to 6 1.8s to 180s 0 to 18 6s to 600s 0 to 60 Time Range Selector 1S Time range can be selected from 1S and 10S using a flat screwdriver and five different dials of 0 to 1, 0 to 3, 0 to 6, 0 to 18, and 0 to 60 are displayed in the six windows by turning the Dial Selector, allowing for selecting the best suited scale. Note that the switch does not turn infinitely. G 10S Timers Base Time Ranges Remarks Setting Examples: 2. The set time is selected by turning the Setting Knob. 1) When the Setting Knob is set at 2.5, with Dial Selector 0 to 3 and Time Range Selector 1S selected, then the set time is 2.5 seconds. 2) When the Setting Knob is set at 5.0, with Dial Selector 0 to 60 and Time Range Selector 10S selected, then the set time is 500 seconds. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-39 Timers GT3F Series Instructions: Wiring Inputs Inputs of GT3F To avoid electric shock, do not touch the input signal terminal during power voltage application. Never apply the input signals to two or more GT3F timers using the same contact or transistor. Incorrect Correct GT3 Series Input Contact Timer or Transistor Input } Terminal 2 Input } Terminal Power 10 ~ 2 Input } Terminal 2 Power 10 ~ Input } Terminal 10 2 10 In a transistor circuit for controlling input signals, with its primary and secondary power circuits isolated, do not ground the secondary circuit. GT3 Series Timer Input } Terminal G Circuit Rectifier Circuit Timers ~ Power Insulating Transformer On the GT3F timers, connect the input signals to terminal No.1 and 4 only on the 8-pin type; connect the input signals to terminal No. 6 and 7 only on the 11-pin type. Never apply voltage to other terminals; otherwise, the internal circuit may be damaged. Input signal lines must be made as short as possible and installed away from power cables and power lines. Use shielded wires or a separate conduit for input wiring. The GT3F, consisting of a high-impedance circuit, may not be reset due to the influence of an inductive voltage or residual voltage caused by a leakage current. If not reset, connect an RC filter or bleeder resistor between power terminals so that the voltage between power terminals can be reduced to less than 15% of the rated voltage. G-40 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3S Series GT3 (Star-Delta) Timers Star-Delta Star Output Indicator Delta Output Indicator Star Setting Knob Star-Delta Switching Time Selector 0.05 sec, 0.1 sec, 0.25 sec, 0.5 sec Star Dial Selector 0-5, 0-10, 0-50, 0-100 Operation Mode Star-Delta Rated Input Voltage Time Range Star: 0.05 to 100 sec Star-Delta switching time: 0.05 sec 0.1 sec 0.25 sec 0.5 sec AF20: 100 to 240V AC (50/60Hz) 250V AC/30V DC, 5A (resistive load) Contact Part No. 8-pin Type Star: Delayed SPST-NO Delta: Delayed SPST-NO GT3S-1AF20 Star: Delayed SPST-NO Delta: Delayed SPST-NO Instantaneous: SPST-NO GT3S-2AF20 G Timers Time Ranges: Star-Delta Switching Time Selector Star Dial Selector Dial Output Time Range UL c-uL Listed File No. E55996 Time 0-5 0.05 sec - 5 sec 0.05 sec 0-10 0.1 sec - 10 sec 0.1 sec 0-50 0.5 sec - 50 sec 0.25 sec 0-100 1 sec - 100 sec 0.5 sec Contact Ratings: Contact Ratings Life 250V AC/30V DC, 5A (resistive load) Mechanical 20,000,000 operations minimum Electrical 100,000 operations minimum (rated load) GT3S Table of Contents Specifications -- G-42 Operation Charts -- G-43 GT3 Accessories -- G-48 GT3 Instructions -- G-50 GT3 Dimensions -- G-52 Timing Diagrams Overview -- G-4 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-41 Timers GT3S Series General Specifications Operation System Operation Type Time Range Rated Operational Voltage Operating Temperature Storage Temperature Operating Humidity Voltage Tolerance Repeat Error Voltage Error Temperature Error Setting Error Reset Time Insulation Resistance Dielectric Strength Timers G Solid state CMOS circuitry Star-delta Star side: 0.05 to 100 sec Star-delta switching time: 0.05, 0.1, 0.25, 0.5 sec 100 to 240V AC (50/60Hz) -10 to +50C -30 to +80C 45 to 85% RH 85 to 264V AC 0.2%, 10 msec 0.2%, 10 msec 0.2%, 10 msec 10% maximum 500 msec maximum 100M minimum Between power and output terminals: 2,000V AC, 1 minute Between contacts of different poles: 2,000V AC, 1 minute Between contacts of the same pole: 750V AC, 1 minute Vibration Resistance 100 m/sec2 (Approx. 10G) Shock Resistance Operating extremes: 100m/sec2 (Approx. 10G) Damage limits: 500m/sec2 (Approx. 50G) Power Consumption (Approx.) G-42 Type GT3S-1 Type GT3S-2 3.0VA (100V AC, 60Hz), 10.4VA (200V AC, 60Hz) 4.0VA (100V AC, 60Hz), 12.0VA (200V AC, 60Hz) www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3S Series Operation Charts Product Series GT3S-1 Internal Connection & Terminal Arrangement Operation Chart (8-pin Type) 4 Star: Delayed SPST-NO Item 5 3 6 2 7 Star Delayed Contact 2-7 (8p) 2-10 (11p) (POWER) 5-8 (8p) 1-3 (11p) (NO) Delta Delayed Contact 6-8 (8p) 9-11 (11p) (NO) Delta: Delayed SPST-NO 1 8 POWER 5-8: Star contact 6-8: Delta contact (11pin Type) 6 Star Indicator Delta 7 5 Set Time 8 4 3 9 1 T1 T2 T3 The star delayed contact goes on when power is turned on and goes off after a set time for the star contact (T1). The delta delayed contact goes on after star-delta switching time (T2) and goes off when power is turned off. T1 = Star ON time (Set Time), T2 = Star-delta switching time, T3 = Delta ON time 10 2 Operation Terminal No. Power 11 POWER 1-3: Star contact 9-11: Delta contact GT3S-2 (8-pin Type) 3 6 2 7 1 8 POWER 5-8: Star contact 6-8: Delta contact Star Delayed Contact Delta Delayed Contact 6-8 (8p) 9-11 (11p) (NO) Instantaneous Contact 1-3 (8p) 6-7 (11p) (NO) G Star (11pin Type) Indicator 6 Delta 7 5 8 4 Set Time 3 9 10 2 1 11 POWER 1-3: Star contact 9-11: Delta contact 6-7: Instantaneous contact www.idec.com Operation Terminal No. 2-7 (8p) 2-10 (11p) (POWER) 5-8 (8p) 1-3 (11p) (NO) Power Timers Delta: Delayed SPST-NO Instantaneous SPST-NO Item 5 4 Star: Delayed SPST-NO T1 T2 T3 The star delayed contact goes on when power is turned on and goes off after a set time for the star contact (T1). The delta delayed contact goes on after star-delta switching time (T2) and goes off when power is turned off. The intantaneous contact goes on when power is turned on and goes off when power is turned off. T1 = Star ON time (Set Time), T2 = Star-delta switching time, T3 = Delta ON time USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-43 Timers GT3W Series GT3W Series -- Dual Time Range Timers Key features of the GT3W series include: * Sequential start, sequential interval, on-delay, recycler, and interval ON timing functions * 2 time settings in one timer * 8 selectable operation modes on each model * Mountable in sockets or flush panel * Power and output status indicating LEDs * Time ranges up to 300 hours c-uL Listed UL Listed File No.E55996 General Specifications Operation System Operation Type Time Range Pollution Degree Over voltage category Voltage Tolerance Multi-Mode 1: 0.1sec to 6hours, 3: 0.1sec to 300hours 2 (IE60664-1) III (IE60664-1) AF20 AD24 D12 AF20 AD24 D12 Disengaging value of Input Voltage Range of Ambient Operating Temperature Range of Ambient Storage and Transport Temperature Range of Relative Humidity Atmospheric Pressure Reset Time Repeat Error Voltage Error Temperature Error Setting Error Insulation Resistance 100-240V AC(50/60Hz) 24V AC(50/60Hz)/24V DC 12V DC 85-264V AC(50/60Hz) 20.4-26.4V AC(50/60Hz)/21.6-26.4V DC 10.8-13.2V DC Vibration Resistance Degree of Protection Conditional Short Circuit Electrical Mechanical 1/8HP, 240V AC 3A, 240V AC (Resistive) 5A, 120V AC/30V DC (Resistive) Fuse 5A, 250V 100,000 op. minimum (Resistive) 20,000,000 op. minimum -10 to +50C (without freezing) -30 to +75C (without freezing) 35 to 85%RH (without condensation) 80kPa to 110kPa (Operating), 70kPa to 110kPa (Transport) 60msec maximum 0.2%, 10msec* 0.2%, 10msec* 0.6%, 10msec* 10% maximum 100M minimum (500V DC) 100V AC/60Hz 2.3VA 200V AC/60Hz 4.6VA AF20 AD24 (AC/DC) Rated Load Life Rated Voltage x10% minimum Operating extremes: 98m/sec2 (approx.10G) Damage limits: 490m/sec2 (approx. 50G) 3 times in each of 3 axes IP40 (enclosure), IP20 (socket) (IEC60529) Shock Resistance Mounting Position Dimensions Weight (Approx.) Contact Ratings Allowable Contact Power 960VA/120W 250V AC/150V DC Allowable Voltage 5A Allowable Current Maximum permissible 1800 cycles per hour operating frequency Between power and output terminals: 2000V AC, 1 minute Between contacts of different poles: 2000V AC, 1 minute Between contacts of the same pole:750V AC, 1 minute 10 to 55Hz amplitude 0.75mm2 hours in each of 3 axes Dielectric Strength Power Consumption (Approx.) Timers G Rated Operational Voltage Solid state CMOS Circuit 1.8VA/0.9W Free 40Hx 36W x 70 mm 72g GT3W Table of Contents Specifications -- G-44 Part Number List -- G-45 Timing Diagrams / Schematics -- G-46 Instructions: Setting Timer -- G-47 GT3 Accessories -- G-48 GT3 Instructions -- G-50 GT3 Dimensions -- G-52 Timing Diagrams Overview -- G-4 ** For the value of the error against a preset time, whichever the largest. G-44 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3W Series Part Number List Part Numbers Mode of Operation Output Contact Time Range* Rated Voltage Pin Configuration New Part Numbers 8 pin GT3W-A11AF20N 11 pin GT3W-A11EAF20N 8 pin GT3W-A11AD24N 11 pin GT3W-A11EAD24N 8 pin GT3W-A11D12N 11 pin GT3W-A11ED12N 100 to 240V AC (50/60Hz) A: Sequential Start B: On-delay with course & fine 1: 0.1sec - 6 hours C: Recycler & instaneous *(See Time Range Settings for details.) D: Recycler outputs (OFF Start) 24V AC/DC Delayed SPDT + 5A, 120V AC/30V DC E: Recycler outputs Delayed (Resistive Load) (ON Start) SPDT 3A, 240V AC F: Interval ON 12V DC G: Interval ON Delay G H: Sequential Interval 3: 0.1sec - 300 hours Timers GT3W-A33AF20N 100 to 240V AC (50/60Hz) 8 pin 24V AC/DC GT3W-A33AD24N 1. For schematics, see page G-46. 2. For socket and accessory part number information, see page G-48. 3. 8- and 11-pin models differ only in the number of pins (extra pins are not used). 4. For the timing diagram overview, see page G-4. 5. *For details on setting time ranges, see the instructions on page G-47. Time Range Table Time Range Code: 1 Time Range Selector Scale 1S Time Range Time Range Code: 3 Time Range Selector Scale Time Range 0.1 sec - 1 sec 1S 0.3 sec - 10 sec 1M 10M 15 sec - 10 min 1H 3 min - 3 hours 1S 0.1 sec - 6 sec 1S 0.6 sec - 30 sec 10S 1 sec - 60 sec 1M 36 sec - 30 min 6 sec - 6 min 1H 10S 1M 0-1 0-6 10M 1 min - 60 min 1H 6 min - 6 hours www.idec.com 10H 0.1 sec - 3 sec 0-3 0 - 30 3 sec - 3 min 36min - 30 hours 6 hours - 300 hours USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-45 Timers GT3W Series Timing Diagrams/Schematics 8-Pin 4 11-Pin 5 3 6 5 7 4 6 8 3 (-) 2 7 (+) (-) 8 1 POWER MODE Terminal No. E : Recycler outputs (ON Start) A : Sequential Start Indicator 1-4(8p) 1-4(11p) (NC) 1-3(8p) 1-3(11p) (NO) 5-8(8p) 8-11(11p) (NC) 6-8(8p) 9-11(11p) (NO) OUT1 OUT2 Set Time Timers G T2 Operation Delayed Contact Ry2 Indicator 1-4(8p) 1-4(11p) (NC) 1-3(8p) 1-3(11p) (NO) 5-8(8p) 8-11(11p) (NC) 6-8(8p) 9-11(11p) (NO) OUT1 T1 Terminal No. T2 Operation D : Recycler outputs (OFF Start) Item Indicator G-46 G : Interval ON Delay OUT1 OUT2 T1 Terminal No. T2 T1 Terminal No. T1 T2 T1 T2 Operation Delayed Contact Ry2 1-4(8p) 1-4(11p) (NC) 1-3(8p) 1-3(11p) (NO) 5-8(8p) 8-11(11p) (NC) 6-8(8p) 9-11(11p) (NO) OUT1 OUT2 Terminal No. Delayed Contact Ry1 T1 T2 Operation Delayed Contact Ry2 Indicator 1-4(8p) 1-4(11p) (NC) 1-3(8p) 1-3(11p) (NO) 5-8(8p) 8-11(11p) (NC) 6-8(8p) 9-11(11p) (NO) OUT1 OUT2 Set Time T2 Operation Item Terminal No. T1 T2 Operation 2-7(8p) Power 2-10(11p) 1-4(8p) 1-4(11p) (NC) 1-3(8p) 1-3(11p) (NO) 5-8(8p) 8-11(11p) (NC) 6-8(8p) 9-11(11p) (NO) OUT1 OUT2 Set Time OUT2 2-7(8p) 2-7(8p) Delayed Contact Ry2 OUT1 Power 2-10(11p) Power 2-10(11p) Delayed Contact Ry1 Delayed Contact Ry1 Item 1-4(8p) 1-4(11p) (NC) 1-3(8p) 1-3(11p) (NO) 5-8(8p) 8-11(11p) (NC) 6-8(8p) 9-11(11p) (NO) Set Time Indicator 1-4(8p) 1-4(11p) (NC) 1-3(8p) 1-3(11p) (NO) 5-8(8p) 8-11(11p) (NC) 6-8(8p) 9-11(11p) (NO) Set Time H : Sequential Interval C : Recycler and instaneous Indicator Delayed Contact Ry2 Indicator OUT2 2-7(8p) Delayed Contact Ry2 Delayed Contact Ry1 2-7(8p) Power 2-10(11p) Delayed Contact Ry1 Operation 2-7(8p) Power 2-10(11p) Set Time Item (+) Power 2-10(11p) Item 2-7(8p) Power 2-10(11p) Delayed Contact Ry1 Terminal No. Set Time F : Interval ON B : On-delay with course and fine Item T1 Terminal No. 11 Operation chart Item 2-7(8p) Delayed Contact Ry2 10 1 POWER Operation Power 2-10(11p) Delayed Contact Ry1 2 MODE Operation chart Item 9 T1 T2 www.idec.com T1 T2 Delayed Contact Ry1 Delayed Contact Ry2 Indicator 1-4(8p) 1-4(11p) (NC) 1-3(8p) 1-3(11p) (NO) 5-8(8p) 8-11(11p) (NC) 6-8(8p) 9-11(11p) (NO) OUT1 OUT2 Set Time T1 T2 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3W Series Instructions: Setting GT3W Timer T2 Time Range Selector T2 Setting Knob Operation Mode Selector T1 Setting Knob 1. The switches should be securely turned using a flat screwdriver 4mm wide (maximum). Note that incorrect setting may cause malfunction. The switches, which do not turn infinitely, should not be turned beyond their limits. 2. Since changing the setting during timer operation my cause malfunction, turn power off before changing. T1 Time Range Selector Safety Precautions Caution Caution notices are used where inattention might cause personal injury or damage to equipment. * The Electronic Timer is designed for installation in equipment. Do not install the Electronic Timer outside equipment. * Install the Electronic Timer in environments described in the specifications. If the Electronic Timer is used in places where it will be subjected to high-temperature, high-humidity, condensation, corrosive gases, excessive vibrations, or excessive shocks, then electrical shocks, fire hazard, or malfunction could result. * Use an IEC60127-approved fuse and circuit breaker on the power and output line outside the Electronic Timer. * Do not disassemble, repair, or modify the Electronic Timer. * When disposing of the Electronic Timer, do so as industrial waste. Warning Warning notices are used to emphasize that improper operation may cause sever personal injury or death. * Turn power off to the Electronic timer before starting installation, removal, Wiring, maintenance, and inspection on the Electronic Timer. * Failure to turn power off may cause electrical shocks or fire hazard. * Emergency stop and interlocking circuits must be configured outside the Electronic timer. If such a circuit is configured inside the Electronic Timer, failure of the Electronic timer may cause malfunction of the control system, or an accident. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-47 G Timers Special expertise is required to use Electronic Timers. * All Electronic Timer modules are manufactured under IDEC's rigorous quality control system, but users must add a backup or fail safe provision to the control system when using the Electronic Timer in applications where heavy damage or personal injury may occur should the Electronic Timer fail. * Install the Electronic Timer according to instructions described in this catalog. * Make sure that the operating conditions are as described in the specifications. If you are uncertain about the specifications, contact IDEC in advance. * In these directions, safety precautions are categorized in order of importance to Warning and Caution. Timers GT3 Series Accessories Accessories: GT3 Series DIN Rail Mounting Accessories Part Numbers: DIN Rail/Surface Mount Sockets and Hold-Down Springs DIN Rail Mount Socket Style Appearance Use with Timers Part No. 8-Pin Screw Terminal (dual tier) GT3A-1, 2, 3 (8-pin) GT3D-1, 2, 3 (8-pin) GT3F-1, 2 (8-pin) GT3W (8-pin) GT3S SR2P-05 11-Pin Screw Terminal (dual tier) GT3A-1, 2, 3 (11-pin) GT3A-4, 5, 6 GT3D-1, 2, 3 (11-pin) GT3D-4, 8 GT3F-1, 2 (11-pin) GT3W (11-pin) SR3P-05 8-Pin Fingersafe Socket GT3A-1, 2, 3 (8-pin) GT3D-1, 2, 3 (8-pin) GT3F-1, 2 (8-pin) GT3W (8-pin) GT3S SR2P-05C 11-Pin Fingersafe Socket GT3A-1, 2, 3 (11-pin) GT3A-4, 5, 6 GT3D-1, 2, 3 (11-pin) GT3D-4, 8 GT3F-1, 2 (11-pin) GT3W (11-pin) SR3P-05C 8-Pin Screw Terminal GT3A-1, 2, 3 (8-pin) GT3D-1, 2, 3 (8-pin) GT3F-1, 2 (8-pin) GT3W (8-pin) GT3S SR2P-06 11-Pin Screw Terminal GT3A-1, 2, 3 (11-pin) GT3A-4, 5, 6 GT3D-1, 2, 3 (11-pin) GT3D-4, 8 GT3F-1, 2 (11-pin) GT3W (11-pin) SR3P-06 DIN Mounting Rail Length 1000mm -- BNDN1000 Applicable Hold-Down Springs Appearance Part No. SFA-203 Timers G SFA-202 Installation of Hold-Down Springs DIN Rail Mount Socket Panel Mount Socket Insert the springs into the outer slots with the projections facing inside. Hold-down Spring SFA-402 Insert the springs into the slots. Insert Socket SR3P-05 Socket SR2P-06 G-48 Hold-down Spring (sold separately) SFA-202 (use two springs) www.idec.com Hold-down Spring (sold separately) SFA-203 (use two springs) 8-pin Socket SR2P-511 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3 Series Accessories Panel Mounting Accessories Part Numbers: Panel Mount Sockets and Hold-Down Springs Panel Mount Socket Style Appearance Use with Timers GT3A- (8-pin) GT3D- (8-pin) GT3W- (8-pin) GT3F- (8-pin) GT3S 8-Pin Solder Terminal Applicable HD Springs Part No. Appearance Part No. SR2P-51 SFA-402 GT3A- (11-pin) GT3D- (11-pin) GT3W- (11-pin) GT3F- (11-pin) 11-Pin Solder Terminal SR3P-51 1. For information on installing the hold-down springs, see page G-48. Part Numbers: Flush Panel Mount Adapter and Sockets that use an Adapter Accessory Description Appearance Part No. Adaptor for flush panel mounting GT3 timers All GT3 timers RTB-G01 8-pin screw terminal All 8-pin timers SR6P-M08G All 11-pin timers SR6P-M11G 8-pin solder terminal All 8-pin timers SR6P-S08 11-pin solder terminal All 11-pin timers SR6P-S11 11-pin screw terminal (Shown: SR6P-M08G for Wiring Socket Adapter) G Timers Panel Mount Adapter Use with Timers Sockets for use with Panel Mount Adapter 2. No hold down springs are available for flush panel mounting. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-49 Timers GT3 Series Instructions Instructions: Wiring Inputs for GT3 Series Inputs To avoid electric shock, do not touch the input signal terminal during power voltage application. When connecting the input signal terminals of two or more GT3A timers to the same contact or transistor, the input terminals of the same number should be connected. (Connect Terminals No.2 in common.) Incorrect Correct GT3 Series Input Contact Timer or Transistor Input } Terminal 2 Input } Terminal Power 10 ~ 2 Input } Terminal 2 Power 10 ~ Input } Terminal 10 2 10 In a transistor circuit for controlling input signals, with its primary and secondary power circuits isolated, do not ground the secondary circuit. G Timers GT3 Series Timer Input } Terminal Rectifier Circuit ~ Power Circuit Insulating Transformer Connect the input signal terminals of the GT3A timers to Terminal No.2 only. Never apply voltage to other terminals; otherwise, the internal circuit may be damaged. Ry 5, 6 and 7 Input Terminals 2 10 ~ Power Input signal lines must be made as short as possible and installed away from power cables and power lines. Use shielded wires or a separate conduit for input wiring. G-50 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3 Series Instructions Inputs Instructions: continued For contact input, use highly reliable gold-plated contacts to make sure that the residual voltage is less than 1V when the contacts are closed. A Type B Type Start Reset 6 5 4 2 1 11 8 3 9 (-) 7 4 8 ResetStartGate 3 6 5 7 9 2 10 (+mm) 1 (-) 11 10 (+) POWER POWER For transistor input, use transistors with the following specifications; VCE = 40V, VCES = 1V or less, IC = 50 mA or more, and ICBO = 50A or less. The resistance should be less than 1k when the transistor is on. When the output transistor switches on, a signal is input to the timer. A Type B Type Start Reset 5 Reset Start Gate 6 5 7 4 9 2 (-) 10 1 11 (+) POWER 7 4 8 3 6 8 3 9 2 (-) 10 1 11 (+) G POWER Timers Inputs: GT3A-1, -2, -3 Transistor output equipment such as proximity switches and photoelectric switches can input signals if they are voltage/current output type, with power voltage ranges from 18 to 30V and have1V. When the signal voltage switches from H to L, a signal is input to the timer. Transistor Output Circuit Transistor 5, 6 and 7 } Input Terminals 2 Inputs: GT3A-4, -5, -6 Start Input The start input initiates a time-delay operation and controls output status. Reset Input When the reset input is activated, the time is reset, and contacts return to original state. Gate Input The time-delay operation is suspended while the gate input is on (pause). www.idec.com No-voltage contact inputs and NPN open collector transistor inputs are applicable. 24V DC, 1mA maximum Input response time: 50msec maximum USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-51 Timers GT3 Series Dimensions Dimensions: GT3 Series 36.0 70.0 N40.0 5.6 Unit: mm NOTE: GT3W series are UL Listed when used in combination with following IDEC's sockets: GT3W-A11, A33: SR2P-06* pin type socket. GT3W-A11E, A33: SR3P-05* pin type socket. (*-May be followed by A,B,C or U) The socket to be used with these timers are rated: -Conductor Temperature Rating 60C min. -Use 14AWG max.(2mm2max.) Copper conductors only -Terminal Torque 1.0 to 1.3 N-m Analog GT3 Timer, 8-Pin with SR2P-06 Analog GT3 Timer, 11-Pin with SR3P-06 Analog Setting Type (When using DIN Rail) When using BAA/BAP: 99 maximum (When using DIN Rail) When using BAA/BAP: 99 maximum 64.2 13 18 40 36 22 Digital GT3 Timer, 8-Pin with SR2P-06 0.507" (13mm) 2.34" (60mm) 1.23" (31.7mm) 0.702" (18mm) 0.039" (1mm) 0.858" (22mm) DIN Rail (BAA/BAP/BADA) 64.2 13 52 16.5 20 28.5 G-52 www.idec.com 3 33 o27 40 8 0.507" (13mm) 0.702" (18mm) 0.039" (1mm) 0.858" (22mm) When Mounting on DIN Rail BNDN: 3.84" (98.5mm) Maximum 3.68" (94.5mm) Maximum 1.05" 1.29" (33mm) (27mm) (When using DIN Rail) BAA or BAP: 105.5 maximum Hold-down Spring (SFA-203) 2.5" 0.039" (64.2mm) (1mm) DIN Rail Digital GT3 Timer, 11-Pin with SR3P-05 101.5 maximum 36 18 22 1.56" (40mm) 1.404" (36mm) Analog GT3 Timer, 11-Pin with SR3P-05 Analog Setting Type 13 When Mounting on DIN Rail BNDN: 3.59" (92mm) Maximum 3.43" (88mm) Maximum HD Spring SFA-202 DIN Rail 0.066" (1.7mm) 1.56" (40mm) 2.5" 0.039" (64.2mm) (1mm) 64.2 Digital GT3 Timer, 11-Pin with SR3P-06 When Mounting on DIN Rail BNDN: 3.59" (92mm) Maximum 3.43" (88mm) Maximum HD Spring SFA-202 1.404" (36mm) 8 2.34" (60 mm) 8 DIN Rail 0.066" (1.7mm) 1.23" (31.7mm) 36 Holddown spring (SFA-202) DIN Rail 1 Timers Holddown Spring (SFA-202) 60 1.7 31.7 60 1.7 40 G 31.7 95 maximum 95 maximum 1 Analog Setting Type 1.56" (40mm) 1.404" (36mm) DIN Rail BNDN 2.03" (52mm) 0.507" 2.42" (13mm) 0.039" (64.2mm) (1mm) HD Spring SFA-203 0.644" 0.117" (16.5mm) (3mm) 0.78" 1.11" (28.5mm) (20mm) USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Timers GT3 Series Dimensions Panel Mount Adapter Digital GT3 Timer, 8-Pin and 11-Pin with SR6P-S08 or SR6P-S11 3.82" (98mm) Maximum Panel Mount Panel Thickness: Adapter 0.03" to 0.2" (0.8 to 5mm) Analog GT3 Timer, 8-Pin and 11-Pin with SR6P-S08 or SR6P-S11 98 maximum 48 11 1.87" (48mm) Back Wiring Socket 61.2 0.066" 1.66" (1.7mm)(42.5mm 1.87" (48mm) 42.5 48 1.7 Panel Thickness 0.8 to 5mm 0.12" (3mm) 2.39" (61.2mm) Wiring Socket Adapter 45 45 Mounting Hole Layout 45 G 48N--3 Timers Close Mounting Single Mounting Analog and Digital GT3 Timer, 8-Pin with SR6P-M08G 8-M3.5 Terminal Screw Panel Thickness 0.8 to 5mm 44.6 4 5 6 2 1 8 7 30.4 44.6 3.5 max. 3 5.6 min. o3.6 min. 6.9 max. 7 9.8 x 3 80.5 Analog and Digital GT3 Timer, 11-Pin with SR6P-M11G 11-M3.5 Teminal Screws 45 16.7 3.5 max. 2 1 11 3 8 7 6 45 34 6.9 max. 4 30.5 92 www.idec.com 5.8 min. o3.6 min. 5 9 10 7 8.5 x 4 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G-53 Timers General Instructions General Instructions for All Timer Series Load Current With inductive, capacitive, and incandescent lamp loads, inrush current more than 10 times the rated current may cause welded contacts and other undesired effects. The inrush current and steady-state current must be taken into consideration when specifying a timer. Time Setting The time range is calibrated at its maximum time scale; so it is desirable to use the timer at a setting as close to its maximum time scale as possible. For a more accurate time delay, adjust the control knob by measuring the operating time with a watch before application. Contact Protection Switching an inductive load generates a counter-electromotive force (back EMF) in the coil. The back EMF will cause arcing, which may shorten the contact life and cause imperfect contact. Application of a protection circuit is recommended to safeguard the contacts. Input Contacts Use mechanical contact switch or relay to supply power to the timer. When driving the timer with a solid-state output device (such as a two-wire proximity switch, photoelectric switch, or solid-state relay), malfunction may be caused by leakage current from the solid-state device. Since AC types comprise a capacitive load, the SSR dielectric strength should be two or more times the power voltage when switching the timer power using an SSR. Temperature and Humidity Use the timer within the operating temperature and operating humidity ranges and prevent freezing or condensation. After the timer has been stored below its operating temperature, leave the timer at room temperature for a sufficient period of time to allow it to return to operating temperatures before use. Generally, it is desirable to use mechanical contacts whenever possible to apply power to a timer or its signal inputs. When using solid state devices, be cautious of inrushes and back-EMF that may exceed the ratings on such devices. Some timers are specially designed so that signal inputs switch at a lower voltage than is used to power the timer (models designated as "B" type). Environment Avoid contact between the timer and sulfurous or ammonia gases, organic solvents (alcohol, benzine, thinner, etc.), strong alkaline substances, or strong acids. Do not use the timer in an environment where such substances are prevalent. Do not allow water to run or splash on the timer. Timers G Vibration and Shock Excessive vibration or shocks can cause the output contacts to bounce, the timer should be used only within the operating extremes for vibration and shock resistance. In applications with significant vibration or shock, use of hold down springs or clips is recommended to secure a timer to its socket. Timing Accuracy Formulas Timing accuracies are calculated from the following formulas: Repeat Error Voltage Error = 1 x Maximum Measured Value - Minimum Measured Value x 100% 2 Maximum Scale Value = Tv - Tr x 100% Tr Tv: Average of measured values at voltage V Tr: Average of measured values at the rated voltage Temperature Error = Tt - T20 x 100% T20 Tt: Average of measured values at C T20: Average of measured values at 20C Setting Error G-68 = Average of Measured Values - Set Value x 100% Maximum Scale Value www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC