NES-35 35W Single Output Switching Power Supply series Features : Universal AC input/Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test 2 years warranty SPECIFICATION MODEL OUTPUT NES-35-5 NES-35-12 NES-35-15 NES-35-24 DC VOLTAGE 5V 12V 15V 24V 48V RATED CURRENT 7A 3A 2.4A 1.5A 0.8A CURRENT RANGE 0 ~ 7A 0 ~ 3A 0 ~ 2.4A 0 ~ 1.5A 0 ~ 0.8A RATED POWER 35W 36W 36W 36W 38.4W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 150mVp-p 200mVp-p 240mVp-p VOLTAGE ADJ. RANGE 10.8 ~ 13.2V 1.0% 13.5 ~ 16.5V 1.0% 21.6 ~ 26.4V 1.0% 43.2 ~ 52.8V 1.0% VOLTAGE TOLERANCE Note.3 INPUT LINE REGULATION Note.4 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION Note.5 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 500ms, 30ms/230VAC HOLD UP TIME (Typ.) 50ms/230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 78% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.75A/115VAC 83% 85% 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. -20 ~ +60 DIMENSION 86% 27.6 ~ 32.4V 55.2 ~ 64.8V (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 0.03%/ , 10 ~ 95% RH (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CB(IEC60950-1),CCC GB4943 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 PACKING NOTE 81% 0.5 A/230VAC OVERLOAD EMS IMMUNITY MTBF OTHERS 10ms/115VAC at full load 120 ~ 370VDC COLD START 45A <2mA / 240VAC WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE (Note 6) 1200ms, 30ms/115VAC at full load LEAKAGE CURRENT PROTECTION EMC 4.75 ~ 5.5V 2.0% NES-35-48 / 70% RH Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, light industry level, criteria A 394Khrs min. MIL-HDBK-217F (25 99*97*36mm (L*W*H) 0.36Kg; 45pcs/17.2Kg/0.93CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:NES-35-SPEC 2010-10-18 http://store.iiic.cc/ NES-35 35W Single Output Switching Power Supply Mechanical Specification Unit:mm 36 Case No. 905 2 3.5 51.5 1 9.5 series 3 5.5 97 8.2 4 20.5 55.5 2- M 3 5 55 +V ADJ. 3.5 4.5 89 99 6.5 87 Terminal Pin No. Assignment Assignment DC OUTPUT -V DC OUTPUT +V 3 18 3.5 74 Block Diagram fosc : 60KHz RECTIFIERS & FILTER EMI FILTER I/P 36 2-M 28 3.5 17.5 Pin No. 4 5 Assignment AC/L AC/N FG 7 Pin No. 1 2 3 RECTIFIERS & FILTER POWER SWITCHING +V -V DETECTION CIRCUIT FG O.L.P. CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 40 50 60 70 (HORIZONTAL) 60 50 40 85 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz AMBIENT TEMPERATURE ( ) File Name:NES-35-SPEC 2010-10-18 http://store.iiic.cc/