New Product Switch Mode Power Supply S8JX-G Series S8JX-G S8JX (15/35/50/100/150/300/600-W Models) Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V) S8JX-P * Easy Mounting: Front-mounted type, DIN rail-mounted type are available. Screw-mount at the top. (except 300-/600-W models) * Safety standards: UL 508/60950-1 cUL CSA C22.2 No. 107.1 cUR CSA C22.2 No. 60950-1 EN 50178 (= VDE 0160) Over voltage category III EN 60950-1 (= VDE 0805 Teil 1) * EMC: Conforms to EN 61204-3. (EMI:EN55011 ClassA) * Input conditions: The input voltage range of 15-W, 35-W, 50-W, 100-W, and 150-W models has been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.). For the most recent information on models that have been certified for safety standards, refer to your OMRON website. S8JX-P Series (Applicable to all capacities from 50 W to 600 W) * Limits for harmonic current emissions (conforms to EN61000-3-2) * Conforms to EMI EN55011 Class B * Applicable to input free voltage: 100 to 240 VAC * Extended DC input voltage range: 80 to 370 VDC * DC input is not subject to EC directives and safety standards. * Easy mounting: Front-mounting bracket type and DIN-Rail mounting type are included as standard with the product. Screw-mount at the top. (except 300-/600-W models) * Safety standards - UL508/60950-1, cUL CSA C22.2 No.107.1, cUR CSA C22.2 No.60950-1 - EN50178 (=VDE0160) Over voltage category III EN60950-1 (=VDE0805 Teil1) * High capacity application-covered functions are included as standard with the product. * Alarm detection function, Remote control function, Remote sensing function Common Precautions S8JX-P Series with EMI ClassB and Power Factor Correction is newly added to S8JX Series. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions on page 55. 1 S8JX Model Number Structure Model Number Legend Note: Not all combinations are possible. Refer to List of Models in Ordering Information on page 3. S8JX-G 15-/35-/50-/100-/150-W Models S8JX-G@@@@@@@ 1 1. Power Ratings 015: 15 W 035: 35 W 050: 50 W 100: 100 W 150: 150 W 2. Output Voltage 05: 5 V 12: 12 V 15: 15 V 24: 24 V 48: 48 V 2 3 4 3. Configuration (15/35/50/100/150 W model) None: Open type C: Covered 4. Configuration/mounting None: Front-mounting D: DIN Rail-mounting S8JX-P 300-/600-W Models S8JX-G@@@@@@ 1 1. Power Ratings 300: 300 W 600: 600 W 2 3 2. Output Voltage 05: 5V 12: 12 V 24: 24 V 48: 48 V 3. Configuration/mounting (covered type) C: Front-mounting CD: DIN Rail-mounting Note: Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for details. Common Precautions 2 S8JX Ordering Information List of Models Note: For details on normal stock models, contact your nearest OMRON representative. Configuration Input voltage S8JX-G DIN Rail-mounting * Power ratings 15 W 100 to 240 VAC (free) 50 W 100 W 150 W 300 W 3A 1.3 A 1A 0.65 A 0.35 A 7A 3A 2.4 A 1.5 A 0.75 A 10 A 4.2 A 2.1 A 1.1 A 20 A 8.5 A 4.5 A 2.1 A 30 A 13 A 6.5 A 3.3 A 60 A 27 A 14A 7A Built-in fan No Yes No Model S8JX-G01505CD S8JX-G01512CD S8JX-G01515CD S8JX-G01524CD S8JX-G01548CD S8JX-G03505CD S8JX-G03512CD S8JX-G03515CD S8JX-G03524CD S8JX-G03548CD S8JX-G05005CD S8JX-G05012CD S8JX-G05024CD S8JX-G05048CD S8JX-G10005CD S8JX-G10012CD S8JX-G10024CD S8JX-G10048CD S8JX-G15005CD S8JX-G15012CD S8JX-G15024CD S8JX-G15048CD S8JX-G30005CD S8JX-G30012CD S8JX-G30024CD S8JX-G30048CD * The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). DIN Rail-mounting * Configuration Input voltage Power ratings 15 W 100 to 240 VAC (free) Open type Power Supplies (80 to 370 VDC *) S8JX-G15005@@: Switchable between 100 to 120 VAC and 200 to 240 VAC. (DC power cannot be input.) 35 W 50 W 100 W 150 W Output voltage (VDC) 5V 12 V 15 V 24 V 48 V 5V 12 V 15 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V Output current 3A 1.3 A 1A 0.65 A 0.35 A 7A 3A 2.4 A 1.5 A 0.75 A 10 A 4.2 A 2.1 A 1.1 A 20 A 8.5 A 4.5 A 2.1 A 30 A 13 A 6.5 A 3.3 A Built-in fan No Model S8JX-G01505D S8JX-G01512D S8JX-G01515D S8JX-G01524D S8JX-G01548D S8JX-G03505D S8JX-G03512D S8JX-G03515D S8JX-G03524D S8JX-G03548D S8JX-G05005D S8JX-G05012D S8JX-G05024D S8JX-G05048D S8JX-G10005D S8JX-G10012D S8JX-G10024D S8JX-G10048D S8JX-G15005D S8JX-G15012D S8JX-G15024D S8JX-G15048D Common Precautions 100 to 120 VAC 200 to 240 VAC (Switchable) Output current S8JX-P Covered Power Supplies (80 to 370 VDC *) S8JX-G15005@@: Switchable between 100 to 120 VAC and 200 to 240 VAC. (DC power cannot be input.) 35 W Output voltage (VDC) 5V 12 V 15 V 24 V 48 V 5V 12 V 15 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V * The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). 3 S8JX Front-mounting * S8JX-G Configuration Input voltage Power ratings 15 W 100 to 240 VAC (free) S8JX-P Covered Power Supplies (80 to 370 VDC *) S8JX-G15005@@: Switchable between 100 to 120 VAC and 200 to 240 VAC. (DC power cannot be input.) 35 W 50 W 100 W 150 W 300 W Common Precautions 100 to 120 VAC 200 to 240 VAC (Switchable) 600 W Output voltage (VDC) Output current 5V 12 V 15 V 24 V 48 V 5V 12 V 15 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 3A 1.3 A 1A 0.65 A 0.35 A 7A 3A 2.4 A 1.5 A 0.75 A 10 A 4.2 A 2.1 A 1.1 A 20 A 8.5 A 4.5 A 2.1 A 30 A 13 A 6.5 A 3.3 A 60 A 27 A 14A 7A 120A 53A 27A 13A Built-in fan No Frontmounting bracket Provided Yes No No Yes * The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). 4 Model S8JX-G01505C S8JX-G01512C S8JX-G01515C S8JX-G01524C S8JX-G01548C S8JX-G03505C S8JX-G03512C S8JX-G03515C S8JX-G03524C S8JX-G03548C S8JX-G05005C S8JX-G05012C S8JX-G05024C S8JX-G05048C S8JX-G10005C S8JX-G10012C S8JX-G10024C S8JX-G10048C S8JX-G15005C S8JX-G15012C S8JX-G15024C S8JX-G15048C S8JX-G30005C S8JX-G30012C S8JX-G30024C S8JX-G30048C S8JX-G60005C S8JX-G60012C S8JX-G60024C S8JX-G60048C S8JX Front-mounting * S8JX-G Configuration Input voltage Power ratings 15 W 100 to 240 VAC (free) (80 to 370 VDC *) S8JX-G15005@@: Switchable between 100 to 120 VAC and 200 to 240 VAC. (DC power cannot be input.) 50 W 100 W 150 W Output current 5V 12 V 15 V 24 V 48 V 5V 12 V 15 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 3A 1.3 A 1A 0.65 A 0.35 A 7A 3A 2.4 A 1.5 A 0.75 A 10 A 4.2 A 2.1 A 1.1 A 20 A 8.5 A 4.5 A 2.1 A 30 A 13 A 6.5 A 3.3 A Built-in fan No Frontmounting bracket Provided Model S8JX-G01505 S8JX-G01512 S8JX-G01515 S8JX-G01524 S8JX-G01548 S8JX-G03505 S8JX-G03512 S8JX-G03515 S8JX-G03524 S8JX-G03548 S8JX-G05005 S8JX-G05012 S8JX-G05024 S8JX-G05048 S8JX-G10005 S8JX-G10012 S8JX-G10024 S8JX-G10048 S8JX-G15005 S8JX-G15012 S8JX-G15024 S8JX-G15048 S8JX-P Open type Power Supplies 35 W Output voltage (VDC) * The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). Common Precautions 5 S8JX Ratings, Characteristics, and Functions Input specification S8JX-G Efficiency 35 W Current *3 50/60 Hz (47 to 450 Hz) 100 V input 0.4 A max. 200 V input 0.25 A max. Harmonic current emissions Leakage current *3 Inrush current (for a cold start at 25C) *3 73% min. 100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *9) Frequency *2 Output *4 15 W 68% min. Voltage *2 Input 100 to 240 V input Power ratings *1 Item 1 A max. 0.6 A max. --- 100 V input 0.5 mA max. 200 V input 1 mA max. 100 V input 20 A max. 200 V input 40 A max. Voltage adjustment range *5 -10% to 15% (with V. ADJ) (48-V models: 10%) Ripple *3 2% (p-p) max. Input variation influence 0.4% max. with AC input voltage Load variation influence 0.8% max. (0 to 100% load, rated input voltage) Temperature variation influence 0.05%/C max. (at rated input and output) S8JX-P Startup time 500 ms max. (up to 90% of output voltage at rated input and output) Hold time *3 20 ms min. Overload protection *6 105% to 175% of rated load current, voltage drop, intermittent, automatic reset Overvoltage protection *7 Yes Additional Overheat protection functions Parallel operation No No (However, backup operation is possible; external diodes required.) Common Precautions Series operation Yes (For up to two Power Supplies; external diodes required.) Protective circuit operation indicator No Ambient operating temperature Refer to the derating curve in Engineering Data on page 17 (with no icing or condensation). Storage temperature -25 to 65C (with no icing or condensation) Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA) Insulation resistance 100 M min. (between all outputs and all inputs/PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in X, Y, Z directions Output indicator EMI Other EMS Yes (Color: Green) Conducted Emissions Conforms to EN 55011 Group 1 Class A and based on FCC Class A *9 Radiated Emissions Conforms to EN 55011 Group 1 Class A *9 Electrostatic Discharge Conforms to EN61000-4-2 Radiated Electromagnetic Field Conforms to EN61000-4-3 Electrical Fast Transient/Burst Conforms to EN61000-4-4 Surge Conforms to EN61000-4-5 Conducted Disturbance Conforms to EN61000-4-6 Voltage Dips/Short Interruptions Conforms to EN61000-4-11 UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition) Approved standards *9 cUL Listed: CSA C22.2 No.107.1 cUR: CSA C22.2 No. 60950-1 EN/VDE: EN50178 (= VDE 0160) Over voltage category III, EN 60950-1 (= VDE 0805 Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514)) SEMI SEMI F47-0200 (200-VAC input) Weight *8 250 g max. *1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not start. Refer to Overload Protection on page 20. *2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *3. Rated input voltage: 100 or 200 VAC at 100% load. *4. Output characteristics: Specified at power supply output terminals. *5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *6. For details, refer to Overload Protection on page 20. *7. To reset the protection, turn OFF the input power for seven minutes or longer and then turn it back ON. *8. The weight indicated is for Front-mounting, Open-frame Power Supply. *9. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). 6 S8JX Input specification 76% min. 76% min. 12 V Models 81% min. 81% min. 24 V Models 83% min. 83% min. 48 V Models 82% min. 83% min. 100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *9) Frequency *2 Inrush current (for a cold start at 25C) *3 Output *4 50/60 Hz (47 to 450 Hz) 100 V input 1.4 A max. 200 V input 0.8 A max. Harmonic current emissions Leakage current *3 100 W 5 V Models Voltage *2 Current *3 50 W 2.5 A max. 1.5 A max. --- 100 V input 0.5 mA max. 200 V input 1 mA max. 100 V input 20 A max. 200 V input 40 A max. -10% to 15% (with V. ADJ) (48-V models: 10%) Ripple *3 2% (p-p) max. Input variation influence 0.4% max. (with AC input voltage) Load variation influence 0.8% max. (0 to 100% load, rated input voltage) Temperature variation influence 0.05%/C max. (at rated input and output) Startup time 500 ms max. (up to 90% of output voltage at rated input and output) Hold time *3 20 ms min. Overload protection *6 105% to 175% of rated load current, voltage drop, intermittent, automatic reset Overvoltage protection *7 Yes Additional Overheat protection functions Parallel operation No No (However, backup operation is possible; external diodes required.) Yes (For up to two Power Supplies; external diodes required.) Protective circuit operation indicator No Ambient operating temperature Refer to the derating curve in Engineering Data on page 17 (with no icing or condensation). Storage temperature -25 to 65C (with no icing or condensation) Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA) Insulation resistance 100 M min. (between all outputs and all inputs/PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in X, Y, Z directions Output indicator EMS Yes (Color: Green) Conducted Emissions Conforms to EN 55011 Group 1 Class A and based on FCC Class A *9 Radiated Emissions Conforms to EN 55011 Group 1 Class A *9 Electrostatic Discharge Conforms to EN61000-4-2 Radiated Electromagnetic Field Conforms to EN61000-4-3 Electrical Fast Transient/Burst Conforms to EN61000-4-4 Surge Conforms to EN61000-4-5 Conducted Disturbance Conforms to EN61000-4-6 Common Precautions Series operation EMI S8JX-P Voltage adjustment range *5 Other S8JX-G Efficiency Input 100 to 240 V input Power ratings *1 Item Voltage Dips/Short Interruptions Conforms to EN61000-4-11 UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition) Approved standards *9 cUL Listed: CSA C22.2 No.107.1 cUR: CSA C22.2 No. 60950-1 EN/VDE: EN50178 (= VDE 0160) Over voltage category III, EN 60950-1 (= VDE 0805 Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514)) SEMI SEMI F47-0200 (200-VAC input) Weight *8 300 g max. 550 g max. *1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not start. Refer to Overload Protection on page 20. *2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *3. Rated input voltage: 100 or 200 VAC at 100% load. *4. Output characteristics: Specified at power supply output terminals. *5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *6. For details, refer to Overload Protection on page 20. *7. To reset the protection, turn OFF the input power for seven minutes or longer and then turn it back ON. *8. The weight indicated is for Front-mounting, Open-frame Power Supply. *9. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). 7 S8JX Input specification Power ratings *1 Item S8JX-G 5 V Models 12 V Models 24 V Models 48 V Models Efficiency Voltage *2 Frequency *2 Input 100 V input 200 V input Harmonic current emissions 100 V input Leakage current *3 200 V input 100 V input Inrush current (for a cold start at 25C) *3 200 V input Voltage adjustment range *5 Ripple *3 Input variation influence Load variation influence Temperature variation influence Startup time Hold time *3 Current *3 100/200 V switchable 150 W at 5 V 78% min. ------Switchable between 100 to 120 VAC (allowable range: 85 to 132 VAC) and 200 to 240 VAC (allowable range: 170 to 264 VAC). 50/60 Hz (47 to 450 Hz) 3.5 A max. 2.1 A max. 100 to 240 V input 150 W at 12 V 150 W at 24 or 48 V ----79% min. ----86% min. --85% min. 100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *9) 3.6 A max. 2.2 A max. 3.5 A max. 2.1 A max. S8JX-P --0.5 mA max. 1 mA max. 20 A max. 40 A max. -10% to 15% (with V. ADJ) (48-V models: 10%) 2% (p-p) max. 0.4% max. (with AC input voltage) Output *4 0.8% max. (0 to 100% load, rated input voltage) 0.05%/C max. (at rated input and output) 500 ms max. (up to 90% of output voltage at rated input and output) 20 ms min. 105% to 175% of rated load 105% to 175% of rated load current, voltage drop, Overload protection *6 current, voltage drop, intermittent, automatic reset automatic reset Yes Additional Overvoltage protection *7 No functions Overheat protection Parallel operation No (However, backup operation is possible; external diodes required.) Series operation Yes (For up to two Power Supplies; external diodes required.) Protective circuit operation indicator No Refer to the derating curve in Engineering Data on page 17 (with no icing or Ambient operating temperature condensation). Storage temperature -25 to 65C (with no icing or condensation) Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%) 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) Dielectric strength 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA) Insulation resistance 100 M min. (between all outputs and all inputs/PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in X, Y, Z directions Output indicator Yes (Color: Green) Conducted Emissions Conforms to EN 55011 Group 1 Class A and based on FCC Class A *9 EMI Radiated Emissions Conforms to EN 55011 Group 1 Class A *9 Other Electrostatic Discharge Conforms to EN61000-4-2 Radiated Electromagnetic Field Conforms to EN61000-4-3 Electrical Fast Transient/Burst Conforms to EN61000-4-4 EMS Surge Conforms to EN61000-4-5 Conducted Disturbance Conforms to EN61000-4-6 Voltage Dips/Short Interruptions Conforms to EN61000-4-11 UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition) cUL Listed: CSA C22.2 No.107.1 Approved standards *9 cUR: CSA C22.2 No. 60950-1 EN/VDE: EN50178 (= VDE 0160), Over voltage category III, EN 60950-1 (= VDE 0805 Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514)) SEMI --SEMI F47-0200 (200-VAC input) Weight *8 800 g max. 700 g max. 600 g max. Common Precautions *1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not start. Refer to Overload Protection on page 20. *2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *3. Rated input voltage: 100 or 200 VAC at 100% load. *4. Output characteristics: Specified at power supply output terminals. *5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *6. For details, refer to Overload Protection on page 20. *7. To reset the protection, turn OFF the input power for seven minutes or longer and then turn it back ON. *8. The weight indicated is for Front-mounting, Open-frame Power Supply. *9. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). 8 S8JX Input specification 100/200 V (Selected) Power ratings *1 Item 600 W 5 V models 71% min. 72% min. 12 V models 75% min. 78% min. 24 V models 82% min. 80% min. 48 V models 82% min. 80% min. Voltage *2 100 to 120 VAC (allowable range: 85 to 132 VAC) 200 to 240 VAC (allowable range: 170 to 264 VAC) (Switchable) Frequency *2 50/60 Hz (47 to 450 Hz) 100 V input 8 A max. 16 A max.(5V, 12V, 48V) 14 A max.(24V) 200 V input 4.5 A max. 9 A max.(5V, 12V, 48V) 8 A max.(24V) Current *3 Input Harmonic current emissions Leakage current *3 Inrush current (for a cold start at 25C) *3 --- 100 V input 0.5 mA max. 200 V input 1 mA max. 100 V input 25 A max. 30 A max. 200 V input 50 A max. 60 A max. Voltage adjustment range *5 -10% to 15% (with V. ADJ) (48-V models: 10%) Ripple *3 2.8% (p-p) max.(5V) *6 2% (p-p) max.(12V, 24V, 48V) Input variation influence 0.4% max. Load variation influence 0.8% max. (0 to 100% load, rated input voltage) Temperature variation influence 0.05%/C max. 3.8% (p-p) max.(5V) *6 2% (p-p) max.(12V) *6 2% (p-p) max.(24V, 48V) 650 ms max. Hold time *3 20 ms min. Overload protection *7 105% to 175% of rated load current, Inverted L voltage drop, the circuit will be shut OFF when the overload exceeds 5 s.(5V, 12V) *10 voltage drop, intermittent, automatic reset. (24V, 48V) 105% to 175% of rated load current, Inverted L voltage drop, the circuit will be shut OFF when the overload exceeds 5 s. *10 Yes (5V, 12V) *10 Yes (24V, 48V) *10 Yes *10 Overheat protection Yes (5V, 12V) *10 N0 (24V, 48V) *10 Yes *10 Parallel operation Yes (up to 5 units) Series operation Yes (For up to two Power Supplies; external diodes required.) Protective circuit operation indicator Yes (color: red) (5V, 12V) No (24V, 48V) Ambient operating temperature Refer to the derating curve in Engineering Data on page 17 (with no icing or condensation). Storage temperature -25 to 65C (with no icing or condensation) Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 25 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 25 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 25 mA) Insulation resistance 100 M min. (between all outputs and all inputs/PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in X, Y, Z directions Additional Overvoltage protection *8 functions Output indicator EMI Other EMS 500 ms max. Yes (color: red) Common Precautions Startup time S8JX-P Output *4 S8JX-G Efficiency 300 W Yes (Color: Green) Conducted Emissions *3 Conforms to EN 55011 Group 1 Class A and based on FCC Class A *11 Radiated Emissions Conforms to EN 55011 Group 1 Class A *11 *12 Electrostatic Discharge Conforms to EN61000-4-2 Radiated Electromagnetic Field Conforms to EN61000-4-3 Electrical Fast Transient/Burst Conforms to EN61000-4-4 Surge Conforms to EN61000-4-5 Conducted Disturbance Conforms to EN61000-4-6 Voltage Dips/Short Interruptions Conforms to EN61000-4-11 UL UR: UL 508 (Recognition), UL 60950-1 (Recognition) Approved standards *13 cUR: CSA C22.2 No. 60950-1 EN/VDE: EN50178 (= VDE 0160), Over voltage category III, EN 60950-1 (= VDE 0805 Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514)) Weight *9 1,800 g max. (5V, 12V) 1,600 g max. (24V, 48V) 2,500 g max. 9 S8JX S8JX-G S8JX-P Common Precautions 10 *1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not start. Refer to Overload Protection on page 20. *2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *3. Rated input voltage: 100 or 200 VAC at 100% load. *4. Output characteristics: Specified at power supply output terminals. *5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *6. Measurement methods are based on JEITA standard RC-9131A. Refer to Ripple Noise Voltage on page 57. *7. For details, refer to Overload Protection on page 20. *8. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON. *9. The weight indicated is for Front-mounting Power Supply. *10.The protection-ON alarm indicator will light as soon as the output is interrupted. For resetting, turn OFF the input power, leave for more than three minutes , and then turn it back ON again. *11.Noise values depend on the wiring methods and other factors. Insert noise filters and cores in the input and output lines. 300 W, 5 V: Two E04SR401938 (manufactured by SEIWA) on the output line. 300 W, 12 V: One E04SR401938 (manufactured by SEIWA) on the output line. 600 W, 5 V or 12 V: One FN2450G-16-61 (manufactured by Schaffner) on the input line. One E04RC613620 (manufactured by SEIWA) on the output line. *12.For the 600-W, 5-V and 12-V models, class A compliance was met with an aluminum plate placed under the Power Supply. *13.The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). S8JX Connections Block Diagrams AC (L) INPUT +V Fuse 2.0 A Noise filter DC OUTPUT -V AC (N) Inrush current protection Rectifier Smoothing circuit Rectifier/ Smoothing circuit S8JX-G S8JX-G01505@@ (15 W) S8JX-G01512@@ (15 W) S8JX-G01515@@ (15 W) S8JX-G01524@@ (15 W) Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Photocoupler S8JX-G01548@@ (15 W) Fuse: 2.0 A Noise filter DC OUTPUT -V AC (N) Inrush current protection Rectifier Smoothing circuit Rectifier/ smoothing circuit S8JX-P +V AC (L) INPUT Drive control circuit Overcurrent detection circuit Voltage detection circuit Overvoltage detection circuit Photocoupler AC (L) INPUT +V Fuse 3.15 A Noise filter DC OUTPUT -V AC (N) Inrush current protection Rectifier Smoothing circuit Rectifier/ Smoothing circuit Drive control Circuit Overcurrent detection circuit Voltage detection Common Precautions S8JX-G03505@@ (35 W) S8JX-G03512@@ (35 W) S8JX-G03515@@ (35 W) S8JX-G03524@@ (35 W) Overvoltage detection circuit Photocoupler S8JX-G03548@@ (35 W) +V AC (L) INPUT Fuse: 3.15 A Noise filter DC OUTPUT -V AC (N) Rectifier Inrush current protection Smoothing circuit Rectifier/ smoothing circuit Drive control circuit Overcurrent detection circuit Voltage detection circuit Overvoltage detection circuit Photocoupler 11 S8JX S8JX-G S8JX-G05005@@ (50 W) S8JX-G05012@@ (50 W) S8JX-G05024@@ (50 W) AC (L) INPUT +V Fuse 6.3 A Noise filter DC OUTPUT -V AC (N) Inrush current protection Rectifier Smoothing circuit Rectifier/ Smoothing circuit Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Photocoupler S8JX-G05048@@ (50 W) +V AC (L) S8JX-P INPUT Fuse: 6.3 A Noise filter DC OUTPUT -V AC (N) Inrush current protection Rectifier Smoothing circuit Rectifier/ smoothing circuit Drive control circuit Overcurrent detection circuit Voltage detection circuit Overvoltage detection circuit Photocoupler Common Precautions S8JX-G100@@@@ (100 W) AC (L) INPUT +V Fuse 8A Noise filter DC OUTPUT Inrush current protection Rectifier Smoothing circuit Rectifier/ Smoothing circuit Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Photocoupler 12 -V AC (N) S8JX S8JX-G15005@@ (150 W) +V Fuse: 8A INPUT Noise filter DC OUTPUT -V AC (N) Rectifier/ smoothing circuit Inrush current protection S8JX-G Rectifier/ smoothing circuit AC (L) Drive control circuit Overcurrent detection circuit Voltage detection circuit Overvoltage detection circuit Photocoupler Input voltage switch 100/200 V switching Note: Set the input voltage switch to "115V" for 100 to 120 VAC and to "230V" for 200 to 240 VAC. +V AC (L) INPUT Fuse 10 A Noise filter DC OUTPUT -V AC (N) Inrush current protection Smoothing circuit Rectifier S8JX-P S8JX-G15012@@ (150 W) S8JX-G15024@@ (150 W) S8JX-G15048@@ (150 W) Rectifier/ Smoothing circuit Drive control Circuit Overcurrent detection circuit Voltage detection S8JX-G30005@@ (300 W) S8JX-G30012@@ (300 W) Fan Rectifier/ Smoothing circuit Rectifier/Smoothing circuit AC (L) INPUT +V Fuse 10 A Noise filter DC OUTPUT -V AC (N) Common Precautions Overvoltage detection circuit Photocoupler Rectifier/Smoothing circuit Inrush current protection 100/200V (Selectable) Drive control Circuit Overcurrent detection circuit Voltage detection Overheat detection circuit Overvoltage detection circuit Photocoupler Parallel operation selector Overheat detection circuit Note: Short-circuit the input voltage selector terminals if the input is 100 to 120 VAC. Keep the terminals open if the input is 200 to 240 VAC. 13 S8JX S8JX-G30024@@ (300 W) S8JX-G30048@@ (300 W) S8JX-G Rectifier/ Smoothing circuit +V AC (L) Fuse 10 A INPUT Noise filter DC OUTPUT -V AC (N) Inrush current protection Rectifier/ Smoothing circuit 100/200V (Selectable) Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Photocoupler Parallel operation selector S8JX-P Note: Short-circuit the input voltage selector terminals if the input is 100 to 120 VAC. Keep the terminals open if the input is 200 to 240 VAC. S8JX-G60005@ (600 W) S8JX-G60012@ (600 W) S8JX-G60048@ (600 W) Fan Rectifier/ Smoothing circuit Rectifier/Smoothing circuit +V AC(L) INPUT Fuse 20 A Noise filter DC OUTPUT -V AC(N) Inrush current protection Rectifier/ Smoothing circuit 100/200V (Selectable) Common Precautions Control Circuit Overcurrent detection circuit Voltage detection Overheat detection circuit Overvoltage detection circuit Photocoupler Overheat detection circuit Parallel operation selector Note: Short-circuit the input voltage selector terminals if the input is 100 to 120 VAC. Keep the terminals open if the input is 200 to 240 VAC. S8JX-G60024@ (600 W) Rectifier/ Smoothing circuit +V AC (L) Fuse 20 A INPUT Noise filter DC OUTPUT -V AC (N) Inrush current protection Rectifier/ Smoothing circuit Fan 100/200V (Selectable) Drive control Circuit Overcurrent detection circuit Voltage detection Overheat detection circuit Overvoltage detection circuit Photocoupler Parallel operation selector Note: Short-circuit the input voltage selector terminals if the input is 100 to 120 VAC. Keep the terminals open if the input is 200 to 240 VAC. 14 S8JX Construction and Nomenclature Nomenclature 15-/35-/50-/100-/150-W Models D E A +V -V C C B -V AC (L) B AC (N) 2 AC Input Terminals (L), (N) Connect the input lines to these terminals. *1 3 Protective Earth Terminal (PE) ( Connect the ground line to these terminals. *2 4 Output Voltage Adjuster (V. ADJ) It is possible to increase or decrease the output voltage. 5 Output Indicator (DC ON: Green) Lights green while a direct current (DC) output is ON. 6 Input voltage switch *3 Switches the internal circuits according to the input voltage. "115V": 100 to 120 VAC "230V": 200 to 240 VAC AC (L) AC (N) Function 1 +V A Name DC Output Connect the load lines to these terminals. Terminals (-V), (+V) F ) Bottom 100 to 120 VAC 200 to 240 VAC *1. The fuse is located on the (L) side. It is NOT user-replaceable. For a DC power input, connect the low side to the positive (+) terminal. Note: The S8JX-G15005C is shown *2. This is the protective earth terminal specified in the safety standards. above. Always ground this terminal. *3. This item is applicable only to the S8JX-G15005@@. 300-W 5V, 12V Model 300-W Model No. AC(L) +V +V 1 2 AC Input Terminals (L), (N) Connect the input lines to these terminals. *1 3 Protective Earth Terminal (PE) ( Connect the ground line to these terminals. *2 4 Input Voltage Selector Terminals Short-circuit the terminals if the input is 100 to 120 VAC and open the terminals if the input is 200 to 240 VAC. 5 Output Indicator (DC ON: Green) Lights green while a direct current (DC) output is ON. 6 Output Voltage Adjuster (V. ADJ) It is possible to increase or decrease the output voltage. 7 Protection-ON Alarm Indicator (ALM: Red) The red indicator will be lit if the overvoltage or overheat protection circuit is triggered. This indicator will also be lit when overload is detected. *3 8 Selector of Parallel Operation Set the selector to PARALLEL if the Units are in parallel operation. -V Bottom Note: The S8JX-G30005C is shown above. 300-W 24V, 48V Model A AC (L) +V +V -V -V AC (N) Function ) Common Precautions -V Name DC Output Connect the load lines to these terminals. Terminals (+V), (-V) AC(N) E F S8JX-P Note: The S8JX-G05024CD is shown above. S8JX-G No. D E *1. The fuse is located on the (L) side. It is NOT user-replaceable. *2. This is the protective earth terminal specified in the safety standards. Always ground this terminal. *3. This is not applicable to 24-V and 48-V models. B D C Bottom Note: The S8JX-G30024C is shown above. H 15 S8JX 600-W 5V, 12V Model 600-W Model S8JX-G No. -V -V +V +V Side AC (L) S8JX-P 600-W 24V, 48V Model A 2 AC Input Terminals (L), (N) Connect the input lines to these terminals. *1 3 Protective Earth Terminal (PE) ( Connect the ground line to these terminals. *2 4 Input Voltage Selector Terminals Short-circuit the terminals if the input is 100 to 120 VAC and open the terminals if the input is 200 to 240 VAC. 5 Output Indicator (DC ON: Green) Lights green while a direct current (DC) output is ON. 6 Output Voltage Adjuster (V. ADJ) It is possible to increase or decrease the output voltage. 7 Protection-ON Alarm Indicator (ALM: Red) The red indicator will be lit if the overvoltage or overheat protection circuit is triggered. This indicator will also be lit when overload is detected. 8 Selector of Parallel Operation Set the selector to PARALLEL if the Units are in parallel operation. ) *1. The fuse is located on the (L) side. It is NOT user-replaceable. *2. This is the protective earth terminal specified in the safety standards. Always ground this terminal. FE G -V -V +V +V Function 1 AC (N) Note: The S8JX-G60005C is shown above. Name DC Output Connect the load lines to these terminals. Terminals (+V), (-V) Side H Common Precautions 16 AC (L) AC (N) D B C Note: The S8JX-G60024C is shown above. Reference Values Reliability (MTBF) S8JX-G15012@@ and S8JX-G15005@@ S8JX-G30005@@ and S8JX-G300012@@ S8JX-G6000@@@ Other models 240,000 hrs 200,000 hrs 170,000 hrs 250,000 hrs Definition MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates reliability of devices. Therefore, it does not necessarily represent a life of the product. Life expectancy 10 yrs. min. Definition The life expectancy indicates average operating hours under the ambient temperature of 40C and a load rate of 50%. Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor. S8JX Engineering Data Derating Curves (Standard Mounting) 15-/35-/50-/100-/150-W Models 100 A Load rate (%) Load rate (%) Covered Power Supplies 120 120 100 80 80 60 60 40 40 20 20 0 -20 -10 0 10 20 S8JX-G Open type Power Supplies 0 -20 -10 30 40 50 60 70 80 Ambient Temperature (C) A 0 10 20 30 40 50 60 70 80 Ambient Temperature (C) S8JX-P Note: 1. Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply in areas outside the derating curve (i.e., the area shown by shading 1 in the above graph). 2. If there is a derating problem, use forced air-cooling. 3. For Customers Using a DC Input When using an input voltage of less than 100 VDC, reduce the load calculated with the above derating curve by at least the following coefficients. 35-W and 100-W (5-V or 12-V output) models: 0.8 50-W/150-W models: 0.85 (DC power cannot be input only to the S8JX-G15005@@.) 15-W and 100-W (24-V or 48-V output): 0.9 300-/600-W 24V, 48V Models Parallel Operation Load rate (%) Load rate (%) Single Unit Operation 120 100 120 100 80 60 60 40 40 20 20 Solid line 0 -20 -10 0 10 20 0 -20 -10 30 40 50 60 70 80 Ambient Temperature (C) Dotted line 0 10 20 Front-mounting, Bottom-mounting, DIN Rail mounting, Side mounting (300W 5V, 12V/ 600W 24V, 48V Models) Side mounting (300W 24V, 48V Models) 30 40 50 60 70 80 Ambient Temperature (C) Note: 1. Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply in areas outside the derating curve (i.e., the area shown by shading 1 in the above graph). 2. If there is a derating problem, use forced air-cooling. Common Precautions 80 600-W 5V, 12V Models Parallel Operation 120 Load rate (%) Load rate (%) Single Unit Operation 100 120 100 80 80 60 60 40 40 20 20 0 -20 -10 0 10 20 30 40 50 60 70 80 Ambient Temperature (C) 0 -20 -10 0 10 20 30 40 50 60 70 80 Ambient Temperature (C) Note: 1. Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply in areas outside the derating curve (i.e., the area shown by shading 1 in the above graph). 17 S8JX Mounting 15-/35-/50-/100-/150-W Models S8JX-G The following three mounting methods are possible. . Front-mounting: Refer to Mounting Bracket Provided with Front-mounting Power Supplies . Bottom-mounting . Side-mounting Note: Additional mounting methods are also available using DIN Rail-mounting models. on page 26. B C Standard Mounting 15-/35-/50-/100-/150-W Models Front-mounting Bottom-mounting DIN Rail-mounting Vertical Side-mounting Horizontal Side-mounting * S8JX-P * * * Note: 1. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Use the standard mounting method only. 2. When mounting the Power Supply, mounting it to a metal plate (*) is recommended. 3. Install the Power Supply so that the air flow circulates around the Power Supply, as the Power Supply is designed to radiate heat by means of natural air flow. 300-W 5V, 12V Model e Bottom-mounting Front-mounting 20mm min. 20mm min. 20mm min. Side-mounting 20mm min. Common Precautions DIN Rail mounting Note: 1. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Use the standard mounting method only. 2. When mounting the Power Supply, mounting it to a metal plate (*) is recommended. 3. Do not cover the air holes (provided at fan mounted side and the opposite side) to have enough aircooling. 300-W 24V, 48V Model Bottom-mounting Front-mounting 20mm min. 20mm min. 20mm min. Side-mounting 20mm min. DIN Rail mounting Note: 1. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Use the standard mounting method only. 2. When mounting the Power Supply, mounting it to a metal plate (*) is recommended. 3. Install the Power Supply so that the air flow circulates around the Power Supply, as the Power Supply is designed to radiate heat by means of natural air flow. 18 S8JX 600-W Model Bottom-mounting 20mm min. Side-mounting 20mm min. 20mm min. 20mm min. S8JX-G Front-mounting Note: 1. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Use the standard mounting method only. 2. When mounting the Power Supply, mounting it to a metal plate (*) is recommended. 3. Do not cover the air holes (provided at fan mounted side and the opposite side) to have enough air-cooling. S8JX-P Common Precautions 19 S8JX Overload Protection S8JX-G The Power Supply is provided with an overload protection function that protects the power supply from possible damage by overcurrent. When the output current rises above 105% to 175% min. of the rated current, the protection function is triggered, decreasing the output voltage. When the output current falls within the rated range, the overload protection function is automatically cleared. Note: 1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the power supply may not start. 2. Internal parts may occasionally deteriorate or be damaged if a short-circuited or overcurrent state continues during operation. 3. Internal parts may possibly deteriorate or be damaged if the Power Supply is used for applications with frequent inrush current or overloading at the load end. Do not use the Power Supply for such applications. (Reference value) 300-W 5V, 12V/600-W Model Output voltage (V) Output voltage (V) 15-/35-/50-/100-/150-W (12-/24-/48-V) Models Intermittent operation S8JX-P Output interrupted 0 50 100 Load rate (%) Output voltage (V) 150-W, 5-V Models 50 100 Load rate (%) 300-W 24V, 48V Model Output voltage (V) Common Precautions 0 Intermittent operation 0 20 50 100 Load rate (%) 0 50 100 Load rate (%) If an excessive current flows for 5 s or more, the output will be turned OFF and simultaneously the protection-ON alarm indicator will be lit. To reset the S8JX, turn OFF the power, leave the S8JX for at least three minutes, and then turn it ON again. S8JX Overvoltage Protection 15-/35-/50-/100-/150-W Models S8JX-G Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in the power supply fails. When an excessive voltage that is approximately 130% of the rated voltage or more is output, the output voltage is shut OFF, preventing damage to the load due to overvoltage. Reset the input power by turning it OFF for at least seven minutes and then turning it back ON again. 300-/600-W Models Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in the Power Supply fails. When an excessive voltage that is approximately 120% of the rated voltage or more is output, the output voltage is shut OFF, preventing damage to the load due to overvoltage (Except 300-W 24V, 48V models ). Reset the input power by turning it OFF for at least three minute and then turning it back ON again. Output voltage (V) (Reference value) Overvoltage protection Operating S8JX-P Rated output Voltage Variable range 0V Note: Do not turn ON the power again until the cause of the overvoltage has been removed. Overheat Protection 300-W 5V, 12V/600-W Model Inrush Current, Startup Time, Output Hold Time Input ON Input OFF AC input voltage Inrush current on input application AC input current Common Precautions If the internal temperature rises excessively as a result of fan failure or any other reason, the overheat protection circuit will be triggered to shut OFF the output voltage and simultaneously the protection-ON alarm indicator will be lit. Reset the input power by turning it OFF for at least three minutes and then turning it back ON again. 96.5% 90% Output voltage Startup time Hold time (20 ms min.) Note: A maximum startup time of 500 ms is required (650 ms for 300 W). Construct a system configuration that considers the startup time of other devices. 21 S8JX Dimensions (Unit: mm) Front-mounting Models S8JX-G S8JX-G015@@ (15 W) S8JX-G015@@C (15 W) S8JX-G035@@ (35 W) S8JX-G035@@C (35 W) 10 max. Panel mounting holes dimensions 90 Label 9.5 Surface screw mounting 8.2 Two, M3 3.5 (for mounting) Side Mounting 911 750.5 750.5 Five, M3.5 3.5 dia. (for mounting) 820.5 Cover Two, M3 4.5 35.5 820.5 Bottom Mounting 7.5 39.51 8.5 3.5 dia. (for mounting) 780.5 26.5 S8JX-P 17.5 Two, M3 (Depth: 4 mm max.) 15 780.5 3.5 (for mounting) 26.5 500.5 S8JX-G050@@ (50 W) S8JX-G050@@C (50 W) 10 max. Panel mounting holes dimensions 100 Surface screw mounting Label 9.5 8.2 Two, M3 3.5 (for mounting) Side Mounting 921 750.5 750.5 Five, M3.5 920.5 Common Precautions Cover 36 Two, M3 3.5 dia. (for mounting) 4.5 920.5 Bottom Mounting 8 401 3.5 dia. (for mounting) 4.5 920.5 920.5 3.5 (for mounting) 20 26.5 Two, M3 (Depth: 4 mm max.) 20 S8JX-G100@@ (100 W) S8JX-G100@@C (100 W) S8JX-G15024 (150 W) S8JX-G15024C (150 W) S8JX-G15048 (150 W) S8JX-G15048C (150 W) Label 10 max. 100W 650.5 150 150W Panel mounting holes dimensions 100*150W Surface screw mounting 9.5 8.2 Two, M3 3.5 (for mounting) 921 750.5 Side Mounting 750.5 Five, M3.5 1410.5 Cover Two, M3 48 5 3.5 dia. (for mounting) 501 5 Two, M3 (Depth: 4 mm max.) 3.5 dia. (for mounting) 1410.5 8 1410.5 1410.5 3.5 (for mounting) 28 16 22 1220.5 Bottom Mounting S8JX S8JX-G15005 (150 W) S8JX-G15005C (150 W) Two, M4 Label 13 10 Surface screw mounting 178 Two, M3 3.5 (for mounting) 921 Side Mounting S8JX-G Panel mounting holes dimensions 12 max. 680.5 680.5 8.2 9.5 Three, M3.5 Cover 1690.5 601 Two, M3 3.5 dia. (for mounting) 5 1690.5 Bottom Mounting 8 1690.5 Two, M3 5 (Depth: 4 mm max.) 3.5 dia. (for mounting) 1690.5 3.5 (for mounting) 1400.5 S8JX-P 230V 14 33.5 36 Input voltage switch S8JX-G15012 (150 W) S8JX-G15012C (150 W) Panel mounting holes dimensions 10 max. Surface screw mounting 178 Label 3.5 (for mounting) 8.2 Side Mounting 680.5 921 680.5 1690.5 Five, M3.5 Cover 601 Two, M3 3.5 dia. (for mounting) 5 1690.5 8 Bottom Mounting 1690.5 5 1690.5 Two, M3 (Depth: 4 mm max.) 3.5 dia. (for mounting) 3.5 (for mounting) Common Precautions 9.5 Two, M3 33.5 36 14 1400.5 23 S8JX S8JX-G30005C (300 W) S8JX-G30012C (300 W) S8JX-G Panel mounting holes dimensions Eight, M4 holes (Depth: 8 max. on both sides) 22.5 max. Four, M5 terminal screws Surface screw mounting 164.5 Five, M4 terminal screws Four, 4.5 dia. 10 Side Mounting 921 8.6 16 500.5 500.5 1360.5 26 13 Four, 4.5 dia. 21 17 1101 1360.5 Bottom Mounting Four, M4 holes (Depth: 8 max.) 900.5 1360.5 S8JX-P 900.5 10 17 1360.5 S8JX-G30024C (300 W) S8JX-G30048C (300 W) Nine, M4 terminal screws Panel mounting holes dimensions Eight, M4 holes (Depth: 8 max. on both sides) 167.1 20 max. Surface screw mounting Four, 4.5 dia. Common Precautions 10 Side Mounting 8.6 921 1360.5 Four, 4.5 dia. 21 1101 19 1360.5 Bottom Mounting 900.5 1360.5 900.5 Four, M4 holes (Depth: 8 max.) 10 19 24 500.5 500.5 1360.5 S8JX S8JX-G60005@ (600 W) S8JX-G60012@ (600 W) 26 Four, M5 terminal screws 16 26 max. 13 Surface screw mounting 159.8 Four, 4.5 dia. 16.9 Side Mounting 921 S8JX-G 2.5 Panel mounting holes dimensions Eight, M4 holes (Depth: 8 max. on both sides) 1501 500.5 1240.5 500.5 Four, 4.5 dia. 20.9 14.8 8.6 10 Five, M4 terminal screws Bottom Mounting 11 12405 1000.5 Four, M4 holes (Depth: 8 max.) 1370.5 S8JX-P 1000.5 42 14.8 1370.5 1501 3 Eight, M4 holes (Depth: 8 max. on both sides) 8.6 10 Nine, M4 terminal screws 26 max. (38.84) Four, 4.5 dia. OPERATION PARALLEL 921 70 Surface screw mounting 159.8 (14.2) 16 Panel mounting holes dimensions Side Mounting SINGLE 1240.5 500.5 Short bar Four, 4.5 dia. (14.2) 70 8.6 10 (23.8) 500.5 1240.5 Bottom Mounting 11 1000.5 Common Precautions S8JX-G60024C (600 W) S8JX-G60048C (600 W) Four, M4 holes (Depth: 8 max.) 1370.5 1000.5 42 1370.5 14.8 25 S8JX Mounting Bracket Provided with Front-mounting Power Supplies a 15-/35-/50-/100-/150-W Models S8JX-G S82Y-J00F Front-mounting Bracket Front-mounting Method Mounting dimensions Dimensions 1.5 4.6 150.2 11 9 Two, M3 Note: Mounting screws are not provided. Temporarily attach the enclosed mounting bracket as shown in the illustration on the right, hook the holes (parts a) in the Power Supply on hooks on the mounting bracket (parts b), and secure the Power Supply with two mounting screws. b a 60 60 Two, 3.5 dia. Mounting bracket Power Supply 74 4.6 5 b 20 11 20 31.5 4.7 15 t = 1.0 a 20.5 S8JX-P Material: Stainless steel 300-/600-W Models Front-mounting Bracket (S82Y-J30F) 10 dia. Attaching the Mounting Brackets Dimensions with Mounting Brackets 300-W Model R2.5 300-W Model 15 7.5 30 7.5 1450.3 Common Precautions 160 Two, 5 dia. 92 t = 1.6 1450.3 48 Note: To provide ventilation space, the body will shift forward by 21.6 mm from the mounting surface. 320.2 Note: Mounting Brackets are provided in a set, one for the right side and one for the left side. 800.5 Four, M4 600-W Model 600-W Model 1450.3 Note: To provide ventilation space, the body will shift forward by 23.6 mm from the mounting surface. 1200.5 26 Four, M4 S8JX Separately purchasable mounting brackets (Please ask your dealer for details of delivery.) For 30-W/50-W/100-W/150-W/300-W/600-W models (separately purchasable) Models compatible with the S82J-series Mounting Orientation Products names 50-W models 100-W 24 V models Underside mounting 100-W 5 V, 12 V, 150-W 24 V models Model Mounting bracket A (For S8JX-G-series 50-W models) S82Y-JX05B Mounting bracket B (For S8JX-G-series 100-W 24 V models) S82Y-JX10B Mounting bracket C (For S8JX-G-series 100-W 5 V, 12V, 150 W models) S82Y-JX15B 100-W 5 V, 12 V, 150-W 24 V models Front mounting Mounting bracket D (For S8JX-G-series 100-W 5 V, 12 V, 150 W models) S82Y-JX15F 25-W models Underside mounting Mounting bracket E (For S8JX-G-series 30-W models) S82Y-JX03B Underside mounting Mounting bracket F (For S8JX-G-series 300-W models) S82Y-JX30B Front mounting Mounting bracket G (For S8JX-G-series 300-W models) S82Y-JX30F Underside mounting Mounting bracket H (For S8JX-G-series 600-W models) S82Y-JX60B Front mounting Mounting bracket I (For S8JX-G-series 600-W models) S82Y-JX60F 300-W models 600-W models S8JX-G Bracket for changeover from S82J-series The mounting-hole pitch of mounting brackets A - I below is identical to that of our product S82J. These brackets can be used for switchover with the S82J-series. Note: Mounting brackets (A, B, C, D, E, F, G, H, I) are compatible with S82J mounting holes. S8JX-P Mounting Bracket A Method of Mounting S82Y-JX05B 6.5 3.5 dia. 161 150.50.5 R2 R0.5 R1.75 B 40 3.5 28 Thickness = 2 B * A Mounting Bracket B Method of Mounting S82Y-JX10B 170 6.5 4.5 dia. R2 1600.5 R2.25 R0.5 B Common Precautions Screws used A: Accessories (2 locations) Be sure to use the accessory screws. Mounting screw tightening torque (recommended): 0.49 N m B: M3 (2 locations) A 50 4.5 28 Thickness = 2 B A A Screws used A: Accessories (2 locations) Be sure to use the accessory screws. Mounting screw tightening torque (recommended): 0.49 N m B: M4 (2 locations) * 27 S8JX Mounting Bracket C S82Y-JX15B S8JX-G Method of Mounting 188 1780.5 3 R0.5 4.5 dia. R2.25 4.5 50 35 B R2 Thickness = 2 A Screws used A: Accessories (2 locations) Be sure to use the accessory screws. Mounting screw tightening torque (recommended): 0.49 N m B: M4 (2 locations) B S8JX-P * A Mounting Bracket D S82Y-JX15F Method of Mounting 45 54 45.6 4.5 25 B 5 dia. A Common Precautions 1100.5 119 A B Screws used A: Accessories (2 locations) Be sure to use the accessory screws Mounting screw tightening torque (recommended): 0.49 N m B: M4 (2 locations) Thickness = 1.6 * Mounting Bracket E S82Y-JX03B Method of Mounting 124 1120.5 6.5 3.5 dia. R0.5 R1.75 3.5 40 28 B R2 Thickness = 2 B A A 28 Screws used A: Accessories (2 locations) Be sure to use the accessory screws. Mounting screw tightening torque (recommended): 0.49 N m B: M3 (2 locations) * S8JX Mounting Bracket F S82Y-JX30B S8JX-G Method of Mounting 167 1500.1 7 Four, M4 110 Front 1000.1 A B A A B Screws used A: Accessories (4 locations) Be sure to use the accessory screws. B: M4 (4 locations) Screws of a length that will not project beyond the fixture (thickness: 3.2 mm) should be selected. B Thickness = 3.2 Mounting Bracket G S82Y-JX30F 10 dia. R2.5 Method of Mounting 29.6 S8JX-P 11.6 A 7.5 7.5 A 1450.3 160 A 1450.3 A Two, 5 dia. 92 Thickness = 1.6 Screws used A: Accessories (4 locations) Be sure to use the accessory screws. 48 320.2 900.5 Note: For ventilation of the back surface, the body should be placed 21.6 mm in front of the mounting side. Four, M4 Mounting Bracket H Method of Mounting 169 1500.1 9 B 1000.1 170 A Front B A B Eight, M4 A Screws used A: Accessories (4 locations) Be sure to use the accessory screws. B: M4 (4 locations) Screws of a length that will not project beyond the fixture (thickness: 3.2 mm) should be selected. (Although there are 8 holes in the bracket body, only 4 of these are used.) 45 Thickness = 3.2 Common Precautions S82Y-JX60B Mounting Bracket I S82Y-JX60F 10 dia. Method of Mounting R2.5 21.6 A 6.6 7.5 7.5 A 1450.3 160 Two, 5 dia. 92 1450.3 Thickness = 3.2 A A Screws used A: Accessories (4 locations) Be sure to use the accessory screws. 48 320.2 1400.5 Four, M4 Note: For ventilation of the back surface, the body should be placed 23.6 mm in front of the mounting side. 29 S8JX DIN Rail-mounting Models S8JX-G S8JX-G015@@D (15 W) S8JX-G015@@CD (15 W) S8JX-G035@@D (35 W) S8JX-G035@@CD (35 W) 441 90 10 max. 14.5 Label 8.2 9.5 911 Five, M3.5 47 Cover 98.6 35.5 7 (Sliding: 16.6 max.) 39.5 S8JX-P S8JX-G050@@D (50 W) S8JX-G050@@CD (50 W) 441 10 max. 14.5 100 Label 8.2 9.5 921 Five, M3.5 Cover 47 108.6 36 40 Common Precautions S8JX-G100@@D (100 W) S8JX-G100@@CD (100 W) S8JX-G15024D (150 W) S8JX-G15024CD (150 W) S8JX-G15048D (150 W) S8JX-G15048CD (150 W) 7 (Sliding: 16.6 max.) 10 max. 100W 150 150W 100*150W 14.5 Label 8.2 9.5 921 Five, M3.5 47 Cover 48 501 30 158.6 7 (Sliding: 16.6 max.) S8JX S8JX-G15005D (150 W) S8JX-G15005CD (150 W) 601 12 max. 14.5 178 13 921 8.2 9.5 Three, M3.5 S8JX-G Two, M4 Label 10 47 Cover 186.6 7 (Sliding: 16.6 max.) 230V S8JX-P Input voltage switch S8JX-G15012D (150 W) S8JX-G15012CD (150 W) 601 10 max. 178 14.5 Label 9.5 8.2 921 47 Five, M3.5 Cover 7 (Sliding: 16.6 max.) Common Precautions 186.6 31 S8JX S8JX-G30005CD (300W) S8JX-G30012CD (300W) Five, M4 terminal screws 7.5 175.3 22.5 max. S8JX-G 10 8.6 921 16 26 13 46.6 1101 179.3 4.4 (Sliding: 10 max.) S8JX-P Note: Use a metal DIN Rail when mounting a 300-W model to a DIN Rail. S8JX-G30024CD (300 W) S8JX-G30048CD (300 W) Nine, M4 terminal screws 20 max. 177.3 7.5 10 Common Precautions 8.6 1101 921 46.6 4.4 (Sliding: 10 max.) 1101 181.3 Note: Use a metal DIN Rail when mounting a 300-W model to a DIN Rail. 32 S8JX DIN Rail (Order Separately) 7.30.15 4.5 350.3 15 25 10 25 25 1,000 (500) 15 (5) * 25 10 270.15 Model PFP-100N PFP-50N 1 S8JX-G Mounting Rail (Material: Aluminum) * Value in parentheses are for PFP-50N. Mounting Rail (Material: Aluminum) 16 4.5 350.3 27 24 29.2 Model PFP-100N2 15 25 25 10 25 1,000 10 25 End Plate 15 1 1.5 10 1.8 1 50 1.8 35.5 35.5 Model 11.5 PFP-M 10 M4 spring washer S8JX-P 6.2 M4 x 8 panhead screw 1.3 4.8 Note: 1. If there is a possibility that the Unit will be subject to vibration or shock, use a steel DIN Rail. Otherwise, metallic filings may result from aluminum abrasion. 2. If the Unit may be subjected to sliding to either side, attach an End Plate (model PFP-M) on each side of the Unit. Terminal Cover (Order Separately) Terminal Cover model S82Y-JX-C5P S8JX-G-600W, 24-V or 48-V output S8JX-G-300W, input S8JX-G-600W, input S8JX-G-15W S8JX-G-30W S82Y-JTC1 S8JX-G-50W S8JX-G-100W S8JX-G-150W, 12-V, 24-V or 48-V model Replacement Fan (sold separately) Common Precautions S82Y-JX-C4P Applicable Power Supply and applicable location S8JX-G-300W, 24-V or 48-V output Model S82Y-JXFAN 33 MEMO 34 S8JX Model Number Structure Model Number Legend Note: Not all combinations are possible. Refer to List of Models in Ordering Information on page 36. S8JX-P@@@@@@@ 1 1. Power Ratings 050: 50 W 100: 100 W 150: 150 W 2. Output Voltage 05: 5 V 12: 12 V 24: 24 V 48: 48 V 2 3 4 3. Configuration (50/100/150 W model) None: Open type C: Covered 4. Configuration/mounting None: Front-mounting D: DIN Rail-mounting S8JX-G 50-/100-/150-W Models 300-/600-W Models 1 1. Power Ratings 300: 300 W 600: 600 W 2 3 2. Output Voltage 05: 5V 12: 12 V 24: 24 V 48: 48 V 3. Configuration/mounting (covered type) C: Front-mounting CD: DIN Rail-mounting N: Without mounting bracket S8JX-P S8JX-P@@@@@@ Note: Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for details. Common Precautions 35 S8JX Ordering Information List of Models Note: For details on normal stock models, contact your nearest OMRON representative. S8JX-G DIN Rail-mounting * Configuration Input voltage Power ratings 050 W 100 W S8JX-P Covered Power Supplies 100 to 240 VAC (free) 150 W (80 to 370 VDC *) 300 W Output voltage (VDC) 05 V 12 V 24 V 48 V 05 V 12 V 24 V 48 V 05 V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 600 W 24 V 48 V Output current 10 A 4.2 A 2.1 A 1.1 A 20 A 8.5 A 4.5 A 2.1 A 30 A 13 A 6.5 A 3.3 A 60 A 27 A 14 A peak current 16.5 A (200 VAC) 7A 120 A 53 A 27 A peak current 31 A (200 VAC) 13 A Built-in fan No S8JX-P05005CD S8JX-P05012CD S8JX-P05024CD S8JX-P05048CD S8JX-P10005CD S8JX-P10012CD S8JX-P10024CD S8JX-P10048CD S8JX-P15005CD S8JX-P15012CD S8JX-P15024CD S8JX-P15048CD S8JX-P30005CD S8JX-P30012CD S8JX-P30024CD Yes S8JX-P30048CD S8JX-P60005CD S8JX-P60012CD S8JX-P60024CD S8JX-P60048CD Common Precautions * The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). DIN Rail-mounting * Configuration Input voltage Power ratings 050 W Open type Power Supplies 100 to 240 VAC (free) (80 to 370 VDC *) 100 W 150 W Output voltage (VDC) 05 V 12 V 24 V 48 V 05 V 12 V 24 V 48 V 05 V 12 V 24 V 48 V Output current 10 A 4.2 A 2.1 A 1.1 A 20 A 8.5 A 4.5 A 2.1 A 30 A 13 A 6.5 A 3.3 A Built-in fan Model No S8JX-P05005D S8JX-P05012D S8JX-P05024D S8JX-P05048D S8JX-P10005D S8JX-P10012D S8JX-P10024D S8JX-P10048D S8JX-P15005D S8JX-P15012D S8JX-P15024D S8JX-P15048D * The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). 36 Model S8JX Front-mounting * S8JX-G Configuration Input voltage Power ratings 050 W 100 W 150 W 100 to 240 VAC (free) 300 W (80 to 370 VDC *) 05 V 12 V 24 V 48 V 05 V 12 V 24 V 48 V 05 V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 600 W 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 600 W 24 V 48 V 10 A 4.2 A 2.1 A 1.1 A 20 A 8.5 A 4.5 A 2.1 A 30 A 13 A 6.5 A 3.3 A 60 A 27 A 14 A peak current 16.5 A (200 VAC) 7A 120 A 53 A 27 A peak current 31 A (200 VAC) 13 A 60 A 27 A 14 A peak current 16.5 A (200 VAC) 7A 120 A 53 A 27 A peak current 31 A (200 VAC) 13 A Built-in fan Frontmounting bracket No Provided Model S8JX-P05005C S8JX-P05012C S8JX-P05024C S8JX-P05048C S8JX-P10005C S8JX-P10012C S8JX-P10024C S8JX-P10048C S8JX-P15005C S8JX-P15012C S8JX-P15024C S8JX-P15048C S8JX-P30005C S8JX-P30012C S8JX-P30024C S8JX-P30048C S8JX-P60005C S8JX-P60012C S8JX-P60024C S8JX-P60048C S8JX-P30005N S8JX-P30012N Yes S8JX-P30024N No S8JX-P30048N S8JX-P60005N S8JX-P60012N S8JX-P60024N S8JX-P60048N * The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). Front-mounting * Configuration Input voltage Power ratings 050 W Open type Power Supplies 100 to 240 VAC (free) (80 to 370 VDC *) 100 W 150 W Output voltage (VDC) 05 V 12 V 24 V 48 V 05 V 12 V 24 V 48 V 05 V 12 V 24 V 48 V Output current 10 A 4.2 A 2.1 A 1.1 A 20 A 8.5 A 4.5 A 2.1 A 30 A 13 A 6.5 A 3.3 A Built-in fan No Frontmounting bracket Provided Common Precautions 300 W Output current S8JX-P Covered Power Supplies Output voltage (VDC) Model S8JX-P05005 S8JX-P05012 S8JX-P05024 S8JX-P05048 S8JX-P10005 S8JX-P10012 S8JX-P10024 S8JX-P10048 S8JX-P15005 S8JX-P15012 S8JX-P15024 S8JX-P15048 * The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). 37 S8JX Ratings, Characteristics, and Functions Input specification S8JX-G Efficiency 79% min. 12 V Models 76% min. 78% min. 78% min. 24 V Models 77% min. 81% min. 81% min. 48 V Models 80% min. 81% min. 82% min. 100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *9) S8JX-P Output *4 50/60 Hz (47 to 63 Hz) 100 V input 0.75 A max. 1.4 A max. 2.1 A max. 200 V input 0.4 A max. 0.75 A max. 1.1 A max. 0.9 min. Harmonic current emissions Inrush current (for a cold start at 25C) *3 150 W 78% min. Power factor Leakage current *3 100 W 73% min. Frequency *2 Current *3 50 W 5 V Models Voltage *2 Input 100 to 240 V input Power ratings *1 Item Conforms to EN61000-3-2 100 V input 0.5 mA max. 200 V input 1 mA max. 100 V input 17.5 A max. 200 V input 35 A max. Voltage adjustment range *5 -10% to 15% (with V. ADJ) (48-V models: 10%) Ripple *3 2% (p-p) max. This shall be 3% (p-p) or less when the ambient temperature is less than 0C (for only 5 V type). Input variation influence 0.4% max. with AC input voltage Load variation influence 0.8% max. (0 to 100% load, rated input voltage) Temperature variation influence 0.05%/C max. (at rated input and output) Startup time 1,000 ms max. Hold time *3 20 ms min. Overload protection *6 105% to 160% of rated load 105% to 160% of rated load current, voltage drop, current, voltage drop, automatic reset intermittent, automatic reset Overvoltage protection *7 Additional functions Overheat protection Parallel operation Yes No Common Precautions Series operation No (However, backup operation is possible; external diodes required.) Yes (For up to two Power Supplies; external diodes required.) Alarm indicator No Ambient operating temperature Refer to the derating curve in Engineering Data on page 44 (with no icing or condensation). Storage temperature -25 to 75C (with no icing or condensation) Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA) Insulation resistance 100 M min. (between all outputs and all inputs/PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in X, Y, Z directions Output indicator EMI Other EMS Yes (Color: Green) Conducted Emissions Conforms to EN 55011 Group 1 Class B and based on FCC Class B *9 Radiated Emissions Conforms to EN 55011 Group 1 Class B *9 Electrostatic Discharge Conforms to EN61000-4-2 Radiated Electromagnetic Field Conforms to EN61000-4-3 Electrical Fast Transient/Burst Conforms to EN61000-4-4 Surge Conforms to EN61000-4-5 Conducted Disturbance Conforms to EN61000-4-6 Voltage Dips/Short Interruptions Conforms to EN61000-4-11 UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition) Approved standards *9 cUL Listed: CSA C22.2 No.107.1 cUR: CSA C22.2 No. 60950-1 EN/VDE: EN50178 (= VDE 0160) Over voltage category III, EN 60950-1 (= VDE 0805 Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514)) SEMI SEMI F47-0706 (200-VAC input) Weight *8 370 g max. 550 g max. 590 g max. *1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not start. Refer to Overload Protection on page 46. *2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *3. Rated input voltage: 100 or 200 VAC at 100% load. *4. Output characteristics: Specified at power supply output terminals. *5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *6. For details, refer to Overload Protection on page 46. *7. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON. *8. The weight indicated is for Front-mounting, Open-frame Power Supply. *9. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). 38 S8JX Input specification 75% min. 76% min. 12 V models 77% min. 76% min. 24 V models 79% min. 78% min. 48 V models 78% min. 79% min. 100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *8) Frequency *2 4.5 A max. 8.7 A max. 200 V input 2.2 A max. 4.3 A max. 0.9 min. Harmonic current emissions Inrush current (for a cold start at 25C) *3 Conforms to EN61000-3-2 100 V input 0.5 mA max. 200 V input 1 mA max. 100 V input 17.5 A max. 200 V input 35 A max. Voltage adjustment range *5 -10% to 15% (with V. ADJ) (5 V, 48 V models: 10%) Ripple *3 2% (p-p) max. 3% (p-p) max. (for only 5 V type) *12 Input variation influence 0.4% max. Load variation influence 0.8% max. (0 to 100% load, rated input voltage) Temperature variation influence 0.05%/C max. Startup time 1,000 ms max. Hold time *3 20 ms min. Overload protection *6 105% to 160% of rated load current, voltage drop, intermittent, automatic reset. Overvoltage protection *7 Yes Overheat protection Yes Parallel operation Yes (up to 5 Power Supplies) Additional Series operation functions Remote sensing Yes (For up to two Power Supplies; external diodes required.) Supported Remote control Supported Alarm detection indication Yes (color: red) Provided, open-collector output, 30 VDC max, 50 mA max. Ambient operating temperature Refer to the derating curve in Engineering Data on page 44 (with no icing or condensation). Storage temperature -25 to 75C (with no icing or condensation) Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 100 mA) 100 VAC for 1 min. (between all outputs and RC terminals; detection current: 100 mA) 500 VAC for 1 min. (between all outputs and ALM terminals; detection current: 20 mA) Insulation resistance 100 M min. (between all outputs and all inputs/PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in X, Y, Z directions *10 Output indicator Other EMS Yes (Color: Green) Conducted Emissions *3 Conforms to EN 55011 Group 1 Class B and based on FCC Class B *11 Radiated Emissions Conforms to EN 55011 Group 1 Class B *11 Electrostatic Discharge Conforms to EN61000-4-2 Radiated Electromagnetic Field Conforms to EN61000-4-3 Electrical Fast Transient/Burst Conforms to EN61000-4-4 Surge Conforms to EN61000-4-5 Conducted Disturbance Conforms to EN61000-4-6 Common Precautions Alarm output EMI S8JX-P Output *4 50/60 Hz (47 to 63 Hz) 100 V input Power factor Leakage current *3 600 W 5 V models Voltage *2 Current *3 300 W S8JX-G Efficiency Input 100 to 240 V input Power ratings *1 Item Voltage Dips/Short Interruptions Conforms to EN61000-4-11 UL UR: UL 508 (Recognition) *13 UL Listed: UL508 (Listing) *14 UL UR: UL 60950-1 (Recognition) Approved standards *8 cUR: CSA C22.2 No.107.1, CSA C22.2 No. 60950-1 EN/VDE: EN50178 (= VDE 0160) Over voltage category III, EN 60950-1 (= VDE 0805 Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514)) SEMI SEMI F47-0706 (200-VAC input) Weight 1,200 g max. *9 1,800 g max. *9 39 S8JX S8JX-G S8JX-P Common Precautions 40 *1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not start. Refer to Overload Protection on page 46. *2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *3. Rated input voltage: 100 or 200 VAC at 100% load. *4. Output characteristics: Specified at power supply output terminals. *5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *6. For details, refer to Overload Protection on page 46. *7. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON. *8. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). *9. The weight is of the type without a mounting bracket. *10.S8JX-P600@@CD: 100 m/s2 *11.The noise value will vary depending on wiring methods and other characteristics. 300-W/600-W models conform to Class B with an aluminum plate set under the product. For the 300-W 5V and 600-W 5V and 12V models, insert a noise filter (TDK-Lambda RSEN-2016) in the input line. *12.Measurement method conform to RC-9131A of the JEITA standards. For details, refer to Ripple Noise Voltage on page 57. *13.Applicable to the 300-W/600-W 5V and 12V models *14.Applicable to the 300-W/600-W 24V and 48V models S8JX Connections Block Diagrams S8JX-P050@@@@ (50 W) +V Fuse 2.5 A Noise filter DC OUTPUT AC(N) -V Rectifier High-frequency current regulation Inrush current protection Smoothing circuit Rectifier/ Smoothing circuit S8JX-G AC(L) INPUT Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Photocoupler AC(L) INPUT +V Fuse 6.3 A Noise filter DC OUTPUT AC(N) -V Rectifier High-frequency current regulation Inrush current protection Smoothing circuit Rectifier/ Smoothing circuit S8JX-P S8JX-P100@@@@ (100 W) S8JX-P150@@@@ (150 W) Drive control Circuit Overcurrent detection circuit Voltage detection Common Precautions Overvoltage detection circuit Photocoupler 41 S8JX S8JX-P300@@@@ (300 W) S8JX-G ALM Alarm display Fan detection AC(L) Fuse 10 A INPUT ALMC Noise filter Alarm output ALME Photocoupler AC(N) Rectifier Inrush current High-frequency Smoothing protection current regulation circuit Alarm detection +V DC OUTPUT -V Rectifier/ Smoothing circuit Drive circuit Control circuit +V Output voltage monitor -V Overcurrent detection circuit +S Remote sensing Rectifier/ Smoothing circuit Auxiliary power supply circuit Voltage detection Overheating detection Photocoupler Current balance circuit -S CB Power supply balance CBG S8JX-P Overvoltage detection circuit Fan Photocoupler +RC Photocoupler -RC Remote control Rectifier/ Smoothing circuit S8JX-P600@@@@ (600 W) ALM Alarm display Fan detection AC(L) INPUT Fuse 20 A AC(N) Common Precautions 42 ALMC Noise filter Alarm output ALME Rectifier Inrush current High-frequency Smoothing protection current regulation circuit Photocoupler Alarm detection +V DC OUTPUT -V Rectifier/ Smoothing circuit Drive circuit Control circuit +V Output voltage monitor -V Overcurrent detection circuit +S Remote sensing Rectifier/ Smoothing circuit Auxiliary power supply circuit Overheating detection Photocoupler -S CB Current balance circuit Power supply balance CBG Fan Rectifier/ Smoothing circuit Voltage detection Overvoltage detection circuit Photocoupler +RC Photocoupler -RC Remote control S8JX Construction and Nomenclature Nomenclature 50-/100-/150-W Models 5 4 1 1 -V -V 3 2 3 AC(L) 2 AC Input Terminals (L), (N) Connect the input lines to these terminals. *1 3 Protective Earth Terminal (PE) ( Connect the ground line to these terminals. *2 4 Output Voltage Adjuster (V. ADJ) It is possible to increase or decrease the output voltage. 5 Output Indicator (DC ON: Green) Lights green while a direct current (DC) output is ON. AC(L) 2 AC(N) AC(N) Note: The S8JX-P05005CD is shown above. Function 1 +V +V Name DC Output Connect the load lines to these terminals. Terminals (-V), (+V) ) S8JX-G No. 5 4 Note: The S8JX-P15005C is shown *1. The fuse is located on the (L) side. It is NOT user-replaceable. For a DC above. power input, connect the low side to the positive (+) terminal. *2. This is the protective earth terminal specified in the safety standards. Always ground this terminal. 300-W Models 7 No. Name Function Connect the input lines to these terminals. *1 1 Input Terminals (L), (N) 2 Protective Earth Terminal (PE) ( 3 DC Output Terminals (-V), (+V) Connect the load lines to these terminals. 4 Output Indicator (DC ON: Green) Lights green while a direct current (DC) output is ON. 5 Output Voltage Adjuster (V. ADJ) It is possible to increase or decrease the output voltage. 6 Alarm indicator (ALM: Red) This lamp lights up at the time of output voltage deterioration or fan stoppage, and in standby mode by remote control function. 6 ) Connect the ground line to these terminals. *2 S8JX-P 5 4 3 2 1 600-W Models 3 7 5 11 12 9 10 7 8 5 6 3 4 1 2 CN 1/2 4 6 7 1 2 Note: The S8JX-P60024N is shown above. 1: Output voltage monitor terminal (+V) 2: Remote sensing terminal (+S) 3: Output voltage monitor terminal (-V) 4: Remote sensing terminal (-S) 5: Current balance terminal (CB) 6: Current balance ground terminal (CBG) 7: Remote control terminal (+RC) 8: Remote control terminal (-RC) 9: (Not connected) 10: (Not connected) 11: Alarm detection output terminal (ALMC) (Collector side) 12: Alarm detection output terminal (ALME) (Emitter side) Common Precautions Signal output connector *3 Note: The S8JX-P30024N is shown above. *1. The fuse is located on the (L) side. Ensure that the (L) side is set to (+). *2. This is a PE (Protective Earth) terminal defined in safety standards and must be grounded. *3. Signal input/output connectors are included as standard and implemented in the CN1 before shipment. In this connector, the circuits of 1-2, 3-4, and 7-8 are shorted. Removal of the connector may deteriorate the output stability and accuracy, so be sure to perform the connection of +S and -S terminals. Never connect a load to the output voltage monitor terminal (+V, -V). Reference Values Reliability (MTBF) 50 W: 190,000 hrs 100 W: 160,000 hrs 150 W: 160,000 hrs 300 W: 160,000 hrs 600 W: 150,000 hrs Definition MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates reliability of devices. Therefore, it does not necessarily represent a life of the product. Life expectancy 10 yrs. min. Definition The life expectancy indicates average operating hours under the ambient temperature of 40C and a load rate of 50%. Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor. 43 S8JX Engineering Data Derating Curves (Standard Mounting) 50-/100-W Models 120 1 100 150-W Models Front-mounting, DIN Rail mounting, Bottom-mounting Load rate (%) Load rate (%) S8JX-G Front-mounting, DIN Rail mounting, Bottom-mounting, Side-mounting 120 1 100 80 80 Covered type 60 Covered type 60 Open-frame type Open-frame type 40 40 20 20 0 -20 -10 0 10 20 S8JX-P Note: 1. Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply in areas outside the derating curve (i.e., the area shown by shading 1 in the above graph). 2. If there is a derating problem, use forced air-cooling. 3. (For Customers using 100-W type for a DC Input) When using an input voltage of less than 100 VDC, reduce the load calculated with the above derating curve by at least the following coefficients. When using a voltage exceeding 340 VDC, the ambient temperature should be 60C or less. Coefficient S8JX-P 100-W Models 10 20 120 1 100 80 60 Covered type 40 0.9 30 40 50 60 70 80 Ambient Temperature (C) Horizontal-side-mounting Open-frame type 1.0 20 Maximum operating temperature 60C 80 100 340 370 Input voltage (VDC) 300-/600-W Models 120 100 1 80 0 -20 -10 0 10 20 30 40 50 60 70 80 Ambient Temperature (C) Note: 1. Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply in areas outside the derating curve (i.e., the area shown by shading 1 in the above graph). 2. If there is a derating problem, use forced air-cooling. 3. (For customers using 150-W type for a DC Input) When using an input voltage of less than 100 VDC, reduce the load calculated with the above derating curve by at least the following coefficients. When using a voltage exceeding 340 VDC, the ambient temperature should be 60C or less. S8JX-P 150-W Models Coefficient Common Precautions 0 0 Load rate (%) 0 30 40 50 60 70 80 Ambient Temperature (C) Load rate (%) 0 -20 -10 60 1.0 0.8 40 Maximum operating temperature 60C 20 0 -20 -10 0 10 20 30 40 50 60 70 80 Ambient Temperature (C) Note: 1. Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply in areas outside the derating curve (i.e., the area shown by shading 1 in the above graph). 2. The ambient temperature is defined at a location 50 mm forward from the center of the front surface of the product. 3. (For Customers using 300-/600-W type for a DC Input) Reduce the load calculated with the above derating curve by at least the following coefficients. Coefficient S8JX-P 300-/600-W Models 1.0 0.8 0 0 44 80 100 370 Input voltage (VDC) 0 0 80 100 340 370 Input voltage (VDC) S8JX Mounting 50-/100-/150-W Models S8JX-G The following three mounting methods are possible. . Front-mounting: Refer to Mounting Bracket Provided with Front-mounting Power Supplies on page 54. . Bottom-mounting . Side-mounting Note: Additional mounting methods are also available using DIN Rail-mounting models. B C Standard Mounting 50-/100-/150-W Models DIN Rail-mounting Front-mounting Bottom-mounting Vertical Side-mounting Horizontal Side-mounting * * S8JX-P * * Note: 1. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Use the standard mounting method only. 2. When mounting the Power Supply, mounting it to a metal plate (*) is recommended. 3. Install the Power Supply so that the air flow circulates around the Power Supply, as the Power Supply is designed to radiate heat by means of natural air flow. Bottom-mounting Front-mounting 300W 600W 300W 600W Side-mounting 300W 600W Note: 1. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Use the standard mounting method only. 2. When mounting the Power Supply, mounting it to a metal plate (*) is recommended. 3. Do not cover the air holes (provided at fan mounted side and the opposite side) to have enough air-cooling. Common Precautions 300-/600-W Models 45 S8JX S8JX-G Remote sensing function Alarm detection function Use this function when it is desirable to automatically compensate for voltage drops in the load line. The remote sensing function is operated by connecting +S terminal (2 pin on CN) to +side of the load terminal and -S terminal (4 pin on CN) to -side of the load terminal. When the remote sensing function is not used, using a connector provided as standard enables the connection between +S and +V terminals (1 pin on CN) and between -S and -V terminals (3 pin on CN) respectively. When output voltage drops due to overcurrent protection, overvoltage protection, or overheat protection in operation or input voltage drop, when the built-in fan stops, or when the Power Supply goes standby by remote control, the alarm indicator (LED: red) lights up to indicate the output voltage trouble. In addition, the transistor outputs that outside. *2 +V + S8JX -V CN +V +S -V Transistor output: 30 VDC max., 50 mA max. Residual voltage when the function is ON: 2 V max., leakage current when the function is OFF: 0.1 mA max. Detection voltage: approximately 80% of the output voltage setting value When trouble is detected, the transistor output is turned OFF (nonconductive pins 11-12 on CN) and the LED (red) lights up. *1 -S CN ALMC S8JX Vce max : DC30V Ic max : 50mA ALME Common Precautions Remote control function This function is to turn ON/OFF the output by an external signal using +RC terminal (7 pin on CN) and -RC terminal (8 pin on CN) while input voltage remains applied. To use this function, connect a switch or a transistor to +RC and -RC terminals. When not in use, use the standard supplied connector to short-circuit +RC and -RC terminals. +RC S8JX SW CN TR -RC Level Note: 1. The alarm detection function monitors the voltage at the Power Supply output end. To check an accurate voltage, measure a voltage at the load end. 2. Remove the standard supplied connector and prepare a connector separately. Overload Protection The Power Supply is provided with an overload protection function that protects the power supply from possible damage by overcurrent. When the output current rises above 105% to 160% min. of the rated current, the protection function is triggered, decreasing the output voltage. When the output current falls within the rated range, the overload protection function is automatically cleared. Note: 1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the power supply may not start. 2. Internal parts may occasionally deteriorate or be damaged if a short-circuited or overcurrent state continues during operation. 3. Internal parts may possibly deteriorate or be damaged if the Power Supply is used for applications with frequent inrush current or overloading at the load end. Do not use the Power Supply for such applications. (Reference value) 50-W Models Output voltage (V) S8JX-P Note: 1. Use a two-core shield wire for connection line (*1). 2. If the voltage drop on a load line (*2) is large, the output voltage of the power supply may rise by the voltage drop amount and activate the overvoltage protection. Therefore, be sure to use as thick a wire as possible. 3. The voltage drop in the load line must be 0.3 V or less. 4. If the load line is long, be sure to use an electrolytic capacitor between the load terminals. As the used electrolytic capacitor may be heated by ripple current due to the connected load, be sure to use an electrolytic capacitor having an allowable ripple current exceeding the used ripple current. 5. Opening status of +S and -S terminals may deteriorate the output stability and accuracy. Therefore, be sure to connect +S and -S terminals. 6. Remove a connector provided as standard and prepare a harness separately. Output voltage Built-in fan Short or L (0-0.8 V) ON Rotation Open or H (2.4-12 V) OFF Stop Intermittent operation 0 50 Max. applied voltage: 12 V max., Counter voltage: -1 V max., Sink current: 3.5 mA 100-/150-W Models 300-/600-W Models Output voltage (V) Output voltage (V) Note: 1. If counter voltage is applied to remote control terminals, output voltage cannot be turned ON/OFF. Please remember this when wiring. 2. Use a twist wire or a two-core shield wire for connection line. 3. Remote control circuit is disconnected from input and output circuits. 4. Remove a connector provided as standard and prepare a harness separately. 100 Load rate (%) Intermittent operation 0 46 50 100 Load rate (%) 0 50 100 Load rate (%) S8JX Overvoltage Protection Overheat Protection 50-/100-/150-W Models 300-/600-W Models If the internal temperature rises excessively as a result of fan failure or any other reason, the overheat protection circuit will be triggered to shut OFF the output voltage. The alarm indicator lights at the same time. Reset the input power by turning it OFF for at least three minutes and then turning it back ON again. S8JX-G Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in the power supply fails. When an excessive voltage that is approximately 130% of the rated voltage or more is output, the output voltage is shut OFF, preventing damage to the load due to overvoltage. Reset the input power by turning it OFF for at least three minutes and then turning it back ON again. Inrush Current, Startup Time, Output Hold Time 300-/600-W Models Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in the Power Supply fails. When an excessive voltage that is approximately 130% of the rated voltage or more is output, the output voltage is shut OFF, preventing damage to the load due to overvoltage and simultaneously the alarm indicator will be lit. Reset the input power by turning it OFF for at least three minute and then turning it back ON again. Output voltage (V) Input OFF AC input voltage Inrush current on input application AC input current 96.5% 90% Overvoltage protection Operating Startup time Hold time (20 ms min.) Note: A maximum startup time of 1,000 ms is required. Construct a system configuration that considers the startup time of other devices. Rated output Voltage Variable range Output peak current (300-W 24V, 600-W 24V Models) The following conditions should be satisfied for the peak current value. * t1 10 s * Ip rated peak current * lave rated current t1 x100 [%] 35% (180 to 240 VAC) t1+t2 Common Precautions 0V Note: Do not turn ON the power again until the cause of the overvoltage has been removed. Duty= Output voltage S8JX-P (Reference value) Input ON output current [A] Ip: peak current lave: average current t1 t2 Note: 1. Do not hold peak load current over 10 seconds. In addition, you should not use duty cycle under conditions beyond above figure. It may cause damage in its power supply. 2. Please derate peak load current depending on ambient temperature and mounting orientation. 3. Please keep the average current of peak load cycle from becoming more than the rated value. 47 S8JX Dimensions (Unit: mm) Front-mounting Models S8JX-G S8JX-P050@@ (50 W) S8JX-P050@@C (50 W) 11.5 max. Panel mounting holes dimensions 129 Label 9.5 Surface screw mounting 3.5 (for mounting) 8.2 78.50.5 921 Two, M3 Side Mounting 78.50.5 1180.5 Five, M3.5 Cover Two, M3 421 3.5 dia. (for mounting) 1180.5 5 Bottom Mounting 7 1200.5 5 1200.5 3.5 (for mounting) 3.5 dia. (for mounting) 36 22 S8JX-P 15 Two, M3 (Depth: 4 mm max.) 860.5 S8JX-P100@@ (100 W) S8JX-P100@@C (100 W) S8JX-P15012 (150 W) S8JX-P15012C (150 W) S8JX-P15024 (150 W) S8JX-P15024C (150 W) S8JX-P15048 (150 W) S8JX-P15048C (150 W) Panel mounting holes dimensions Surface screw mounting 11.5 max. Two, M3 159 Label Common Precautions 9.5 3.5 (for mounting) 8.2 78.50.5 921 78.50.5 1480.5 Two, M3 Bottom Mounting Five, M3.5 1500.5 Cover 421 5 1480.5 5 1500.5 3.5 dia. (for mounting) 7 3.5 (for mounting) 3.5 dia. (for mounting) 36 22 15 48 Side Mounting Two, M3 (Depth: 4 mm max.) 980.5 S8JX S8JX-P15005 (150 W) S8JX-P15005C (150 W) 13 159 Panel mounting holes dimensions Label 10 Surface screw mounting 3.5 (for mounting) S8JX-G 13.5 max. Two, M4 Two, M3 78.50.5 921 9.5 8.2 Side Mounting 78.50.5 Three, M3.5 1480.5 Cover 421 3.5 dia. (for mounting) 5 1480.5 5 1500.5 7 Two, M3 3.5 (for mounting) Bottom Mounting 1500.5 3.5 dia. (for mounting) 36 15 Two, M3 (Depth: 4 mm max.) 980.5 S8JX-P 22 Common Precautions 49 S8JX S8JX-P300@@C (300 W) Two, 4.5 dia. S8JX-G 70 5 4850.5 5 22.5 max. 165 5 Panel mounting holes dimensions 13 Rear surface screw mounting 26 124.31 110.8 113.50.5 480.5 16 Four, M5 Three, 4.5 dia. 8.5 10 217.3 4.5 13.5 Front Mounting Three, M4 77.61 113.50.5 S8JX-P S8JX-P300@@N (300 W) 22.5 max. 7151 165 5 Four, M4 (Depth: 6 mm max.) Panel mounting holes dimensions Rear surface screw mounting 26 Four, 4.5 dia. 921 13 460.5 Standard Mounting 16 10 Four, M5 8.5 350.5 24.1 20 1200.5 1100.5 Three, M4 Common Precautions 50 Four, 4.5 dia. Four, M4 (Depth: 6 mm max.) 350.5 14 41.5 max. 1200.5 Side Mounting 460.5 1100.5 S8JX S8JX-P600@@C (600 W) Four, M5 Two, 4.5 dia. Panel mounting holes dimensions 16 22.5 max. 5 Rear surface screw mounting 164.8 930.5 110.8 124.31 113.50.5 Front Mounting 113.50.5 217.3 13.5 Three, M4 Three, 4.5 dia. S8JX-G 109 930.5 26 13 10 4.5 8.5 116.61 S8JX-P S8JX-P600@@N (600 W) 164.8 Four, M4 (Depth: 6 mm max.) 1101 26 16 22.5 max. Panel mounting holes dimensions 13 Rear surface screw mounting Four, M5 921 Standard Mounting 21 1250.5 640.5 25 Three, M4 10 1120.5 8.5 Four, M4 (Depth: 6 mm max.) Four, 4.5 dia. 25 Side Mounting 500.5 640.5 1250.5 1120.5 Common Precautions 500.5 Four, 4.5 dia. 40.5 max. 51 S8JX DIN Rail-mounting Models S8JX-G S8JX-P050@@D (50 W) S8JX-P050@@CD (50 W) 43.41 11.5 max. 14.5 129 Label 8.2 9.5 921 47 Five, M3.5 Cover S8JX-P S8JX-P100@@D (100 W) S8JX-P100@@CD (100 W) S8JX-P15012D (150 W) S8JX-P15012CD (150 W) S8JX-P15024D (150 W) S8JX-P15024CD (150 W) S8JX-P15048D (150 W) S8JX-P15048CD (150 W) 137.6 42 43.41 7 (Sliding: 16.6 max.) 11.5 max. 14.5 159 Label 9.5 8.2 921 47 Five, M3.5 Cover 167.6 42 7 (Sliding: 16.6 max.) Common Precautions S8JX-P15005D (150 W) S8JX-P15005CD (150 W) Label Two, M4 13 43.41 13.5 max. 159 14.5 10 921 9.5 8.2 47 Three, M3.5 Cover 42 52 167.6 7 (Sliding: 16.6 max.) S8JX S8JX-P300@@CD (300 W) 70 217.3 8.9 26 13 110.81 16 S8JX-G 22.5 max. 8.5 Four, M5 46 10 77.61 6.6 (Sliding: 12 max.) 222.8 Three, M4 Note: Use a metal DIN Rail when mounting a 300-W model to a DIN Rail. Four, M5 16 22.5 max. 217.3 8.9 S8JX-P 109 26 13 S8JX-P600@@CD (600 W) 110.81 46 Three, M4 8.5 116.61 6.6 (Sliding: 12 max.) Note: Use a metal DIN Rail when mounting a 600-W model to a DIN Rail. Common Precautions 222.8 10 53 S8JX Mounting Bracket Provided with Front-mounting Power Supplies a S8JX-G 50-/100-/150-W Models S82Y-J00F Front-mounting Bracket Front-mounting Method Mounting dimensions Dimensions 1.5 4.6 150.2 11 9 Two, M3 Note: Mounting screws are not provided. Temporarily attach the enclosed mounting bracket as shown in the illustration on the right, hook the holes (parts a) in the Power Supply on hooks on the mounting bracket (parts b), and secure the Power Supply with two mounting screws. b a 60 Two, 3.5 dia. 60 Mounting bracket 74 4.6 5 b 20 11 20 31.5 4.7 15 t = 1.0 a 20.5 S8JX-P Material: Stainless steel DIN Rail (Order Separately) Mounting Rail (Material: Aluminum) 7.30.15 4.5 350.3 15 25 10 25 25 1,000 (500) 15 (5) * 25 10 270.15 Model PFP-100N PFP-50N 1 * Value in parentheses are for PFP-50N. Common Precautions Mounting Rail (Material: Aluminum) 16 4.5 350.3 27 24 29.2 Model PFP-100N2 15 25 25 10 25 1,000 10 25 End Plate 15 1 1.5 10 6.2 M4 x 8 panhead screw 1.8 1 50 1.8 11.5 35.5 35.5 Model PFP-M 10 M4 spring washer 1.3 4.8 Note: 1. If there is a possibility that the Unit will be subject to vibration or shock, use a steel DIN Rail. Otherwise, metallic filings may result from aluminum abrasion. 2. If the Unit may be subjected to sliding to either side, attach an End Plate (model PFP-M) on each side of the Unit. Terminal Cover (Order Separately) Terminal Cover model Applicable Power Supply and applicable location S8JX-P50W S82Y-JTC1 S8JX-P100W S8JX-P150W 12-V, 24-V or 48-V output S82Y-JX-C4P1 S8JX-P 300 W output side S82Y-JX-C5P1 S8JX-P 300 W input side Replacement Fan (sold separately) Product 54 Model Replacement fan unit for 300-W models S82Y-JXP30FAN Replacement fan unit for 600-W models S82Y-JXP60FAN S8JX Safety Precautions Refer to Safety Precautions for All Power Supplies. Minor electric shock, fire, or Product failure may occasionally occur. Do not disassemble, modify, or repair the Product to touch the interior of the Product. S8JX-G CAUTION 15-/35-/50-/100-/150-W Models Standard Mounting (Front-mounting and DIN Rail-mounting) Standard Mounting (Bottom-mounting) *1 *1 Minor burns may occasionally occur. Do not touch the Product while power is being supplied or immediately after power is turned OFF. *1 Fire may occasionally occur. Tighten terminal screws to the specified torque. M3.5, M4:1.13 N*m. (The DC output terminal of S8JX-G15005@@ and S8JX-P15005:1.56 N*m.) M5:2.25 N*m. *3 *1 *2 Standard Mounting (Horizontal Mounting) *1 *1 *3 *2 S8JX-G Series 300-W 5V, 12V Model S8JX-P Minor injury due to electric shock may occasionally occur. Do not touch the terminals while power is being supplied. Always close the terminal cover after wiring. *2 Minor electric shock, fire, or Product failure may occasionally occur. Do not allow any pieces of metal or conductors or any clippings or cuttings resulting from installation work to enter the Product. Precautions for Safe Use * Take adequate measures to ensure proper heat dissipation to increase the long-term reliability of the Product. * The 300 W 24V, 48V models of S8JX-G series are designed to radiate heat by means of natural air-flow. Be sure to allow convection in the atmosphere around devices when mounting. Do not use in locations where the ambient temperature exceeds the range of the derating curve. * The 300 W 5V, 12V, 600 W models of S8JX-G series, and 300 W, 600 W models of S8JX-P series are designed to radiate heat by means of forced air-flow. Do not cover the air holes (provided at fan mounted side and the opposite side) to have enough air-cooling. * The screws must not protrude beyond the following values inside the Power Supply when screw holes provided on the chassis are used. 15 W, 35 W, 50 W, 100 W, or 150 W: 4 mm 300 W or 600 W of S8JX-P series: 6 mm 300 W or 600 W of S8JX-G series: 8 mm Mounting screw tightening torque (recommended value) : 0.54 N*m. * Front mounting is possible using provided mounting bracket. * When cutting out holes for mounting, make sure that cuttings do not enter the interior of the Products. * Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Use the standard mounting method only. * The internal parts may occasionally deteriorate and be broken due to adverse heat radiation. Do not loosen the screw on the side face of the main body. * When mounting two or more Power Supplies side-by-side, allow at least 20 mm for S8JX-G series and 15 mm for S8JX-P series spacing between them. * Provide a space of at least 20 mm back and forth for S8JX-G series, and 50 mm back and forth for S8JX-P series when mounting 300-W and 600-W models as well. * Use the metal plate as the mounting panel. * Minor fire may occasionally occur. Set the input voltage switch to the input voltage that is to be used (150-W, 5-V models of S8JX-G series only). S8JX-G Series 300-W 24V, 48V Model Standard Mounting (Front-mounting and DIN Rail-mounting) *1 *2 *1 Standard Mounting (Bottom-mounting) Common Precautions Mounting *1 *3 *2 *1. Convection of air *2. 20 mm min. (15 mm min. for S8JX-P series) *3. Use a metal plate as the mounting surface. 55 S8JX S8JX-P Series 300-W Models S8JX-G For S8JX-P Series 300-/600-W models, PHD connectors manufactured by JST Mfg. Co., Ltd. should be used. *1 *1 *3 S8JX-G Series 600-W Models *1 *1 *3 S8JX-P Series 600-W Models S8JX-P *1 *1 *3 *1. Convection of air *3. Use a metal plate as the mounting surface. Wiring Common Precautions * Connect the ground completely. A protective earthing terminal stipulated in safety standards is used. Electric shock or malfunction may occur if the ground is not connected completely. * Minor fire may possibly occur. Ensure that input and output terminals are wired correctly. * Do not apply more than 75 N force to the terminal block when tightening it. * Be sure to remove the sheet covering the Product for machining before power-ON so that it does not interfere with heat dissipation. * Use the following material for the wires to be connected to the S8JX to prevent smoking or ignition caused by abnormal loads. Recommended Wire Type 15 W, 35 W AWG12 to AWG20 (a cross section of 0.517 to 3.309 mm2) UL-certified temperature of at least 75C 50W, 100W, 150 W (except for 5 V) AWG12 to AWG16 (a cross section of 1.309 to 3.309 mm2) UL-certified temperature of at least 60C or 60/75C Input side AWG12 to AWG16 (a cross-section of 1.309 to 3.309 mm2) UL-certified temperature of at least 60C or 60/75C Output side AWG8 to AWG14 (a cross-section of 2.081 to 8.368 mm2) UL-certified temperature of at least 60C or 60/75C 150 W at 5 V S8JX-G Input side series 300W 5V, 12V 600W 5V, 12V S8JX-P Output side series 300 W, 600 W AWG12 to AWG20 (a cross section of 0.517 to 3.309 mm2) UL-certified temperature of at least 60C or 60/75C S8JX-G series 300 W 24V, 48V, 600 W 24V, 48V AWG12 to AWG20 (a cross section of 0.517 to 3.309 mm2) UL-certified temperature of at least 60C or 60/75C AWG6 to AWG20 (a cross section of 0.517 to 13.30 mm2) UL-certified temperature of at least 60C or 60/75C * The rated current for the output terminals on the S8JX-G30005@@, S8JXG30012@@, S8JX-G60005@, S8JX-G60012@, S8JX-P300@@ and S8JXP600@@ is 60A for each terminal. The rated current for the output terminals on the S8JX-G30024@@, S8JX-G30048@@, S8JX-G60024@, and S8JXG60048@ is 20 A for each terminal. Use two terminals together if the current flow is higher than the rated terminal current. 56 Method of Manufacturing Connector Harness for Signal I/O Connector used S12B-PHDSS Housing PHDR-12VS Terminal SPHD-001T-P0.5 or BPHD-001T-P0.5 Manufactured by JST Mfg. Co., Ltd. To ensure correct wiring, the following points should be borne in mind when manufacturing the connector. It is recommended that the JST Mfg. Co., Ltd. catalog be read for further details. * Electric cable size AWG26 to AWG22 should be used. * The electric cable sheath stripping length should be approximately 2.3 mm. * Dedicated tool YC (Manufactured by JST Mfg. Co., Ltd.) should be used for crimping of terminals and wiring. * Although UL1007 (Twisted wire) and other equivalent twisted wires can be used for electric cables, UL1061 with a small outer sheath shape and equivalent twisted wires should be used for AWG22. * When accommodating crimped terminal wiring in the housing, insert the wiring as far as possible to the back of the housing in a single movement and check for an audible click. In addition, check that wiring inserted in the housing is properly locked in place. Installation Environment * Do not use the Power Supply in locations subject to shocks or vibrations. In particular, install the Power Supply as far away as possible from contactors or other devices that are a vibration source. * Install the Power Supply well away from any sources of strong, high-frequency noise and surge. Ambient Operating and Storage Environments * Store the Power Supply at a temperature of -25 to 65C (-25 to 75C for S8JX-P series) and a humidity of 25% to 90%. * The Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply outside the derating range (i.e., the area shown by shading 1 in the derating curve diagram on page 44.) * Use the Power Supply at a humidity of 25% to 85%. * Do not use the Power Supply in locations subject to direct sunlight. * Do not use locations where liquids, foreign matter, or corrosive gases may enter the interior of the Product. Overload Protection * Internal parts may possibly deteriorate or be damaged if a shortcircuited, overload or peak load state continues during operation. * Internal parts may possibly deteriorate or be damaged if the Power Supply is used for applications with frequent inrush current or overloading at the load end. Do not use the Power Supply for such applications. Charging a Battery When connecting a battery at the load, connect an overcurrent limiting circuit and overvoltage protection circuit. S8JX Output Voltage Adjuster (V.ADJ) Parallel Operation 15-/35-/50-/100-/150-W Models Parallel operation is not possible. Parallel Operation Incorrect AC (L) AC (N) Ripple Noise Voltage (S8JX-G Series 300 W 5 V and 600 W 5 V or 12 V Models) AC (L) AC (N) The specified standard for the ripple voltage noise was measured with a measurement circuit that is based on JEITA standard RC-9131A. +V -V S8JX-G * The output voltage adjuster (V.ADJ) may possibly be damaged if it is turned with unnecessary force. Do not turn the adjuster with excessive force. * After completing output voltage adjustment, be sure that the output capacity or output current does not exceed the rated output capacity or rated output current. +V -V S8JX-G Series 300-/600-W Models +V C1 C2 -V 150mm C1:100F C2:0.47F Oscilloscope Frequency band: 100 MHz Coaxial cable DIN Rail-mounting To mount the Power Supply to a DIN Rail, pull down the rail stopper until you hear it clicks open, hook portion (A) of the Power Supply onto the DIN Rail, press the Power Supply in direction (B), and then push up the rail stopper to lock the Power Supply in place. AC (N) AC (L) (B) AC (N) 30 mm min. (C) Track stopper Series Operation Two power supplies can be connected in series. The () voltage output can be accomplished with two Power Supplies. Series Operation Correct AC (L) (A) Output Voltage () Correct AC (L) +V AC (L) +V AC (N) -V AC (N) -V AC (L) +V AC (L) +V AC (N) -V AC (N) -V +V -V +V -V Common Precautions To dismount the Power Supply, pull down portion (C) with a flat-blade screwdriver and pull out the Power Supply. Parallel Operation Correct S8JX-P Parallel operation is possible under 80% of the rated value. * To operate in parallel, set the switch to the "PARALLEL" side. * The length and thickness of each wire connected to the load must be the same so that there is no difference in voltage drop value between the load and the output terminals of each Power Supply. * It is desirable to set the same value on the voltage adjuster of each Power Supply. Load S8JX Note: 1. If the load is short-circuited, a reverse voltage will be generated inside the Power Supply. If this occurs the Power Supply may possibly deteriorate or be damaged. Always connect a diode as shown in the figure. Select a diode having the following ratings. Type Schottky Barrier diode Dielectric strength (VRRM) Twice the rated output voltage or above Forward current (IF) Twice the rated output current or above 2. Although Products having different specifications can be connected in series, the current flowing through the load must not exceed the smaller rated output current. 57 S8JX In Case There Is No Output Voltage S8JX-P Series 300-/600-W Models S8JX-G Connecting CB terminal (5 pin on CN) and CBG terminal (6 pin on CN) enables the current balancing function and that allows the parallel operation at 80% or less of the total output capacity. Up to five Power Supplies can be connected. * Use 2-conductor shielded cable as a connection wire (*1). * Adjust the output voltage difference of each Power Supply to 100 mV or less or 1% or less of the rated output voltage, whichever is smaller, using the output voltage adjuster (V. ADJ). During parallel operation, load current may be biased to one side, resulting in damage to internal components. * Parallel operation is used to increase static capacity. The output voltage may drop with sudden load fluctuations. * There may be steps in the rising waveform of the output voltage during parallel operation. * Remove the standard supplied connector and prepare a connector separately. AC(L) S8JX-P AC(N) +V CB CB AC(L) AC(N) -V CBG *1 CBG +V CN S8JX Backup operation Backup operation is possible. (Requires an external diode.) D1 Load +V -V Common Precautions 58 B S8JX-P Series 300-/600-W Models Method of Checking Over-current Protection * Check (after removing load line) whether or not the load is in overcurrent status (including short circuits). -V A The possible cause for no output voltage may be that the overcurrent or overvoltage protection has operated. The internal protection may operate if a large amount of surge voltage such as a lightening surge occurs while turning ON the Power Supply. In case there is no output voltage, please check the following points before contacting us: * Checking overcurrent protected status: Check whether the load is in overcurrent status or is shortcircuited. Remove wires to load when checking. * Checking overvoltage or internal protection: Turn the power supply OFF once, and leave it OFF for at least 7 minutes for S8JX-G series and 3 minutes for S8JX-P series. Then turn it ON again to see if this clears the condition. There is a possibility that functions such as over-current protection, over-voltage protection or overheating protection are functioning. In addition, other possible causes include stoppage of the built-in fan and the remote control function (OFF). Please check the following 5 points and, if there is still no output voltage, contact your OMRON sales representative. S8JX CN S8JX-G Series S8JX-P Series 50-/100-/150-W Models D2 +V -V The same model should be used for power supplies A and B. * Type: Schottky Barrier diode * Withstand voltage (VRRM): Equivalent to or higher than the rated power supply output voltage * Forward current (IF): Double the rated power supply output current or higher * The output voltages of power supplies A and B output should be set higher only by a value equivalent to the drop in diode D1 and D2 forward voltages (VF). In addition, since power loss occurs resulting from power supply output current (IOUT) x diode forward voltage (VF), the diode should be cooled to ensure that its temperature is kept at the value indicated in the catalog or lower. * Since power loss occurs due to load power and the diode, care should be exercised to ensure that the rated power (Rated output voltage x rated output current) for one power supply is not exceeded. * For backup operation, do not connect the CB and CBG terminals on S8JX-P-series 300-W or 600-W models. Method of Checking Over-voltage Protection * Switch off the input power supply, and switch back on after at least 3 minutes have elapsed. * Check whether or not the +S and -S terminals are open. Method of Check Overheating Protection * Switch off the input power supply and switch back on after allowing sufficient time for cooling. Checking for Built-in Fan Stoppage * Check whether or not the built-in fan has stopped. The fan is a replaceable component. Checking the Remote Control Function * Check whether or not the +RC and -RC terminals are in open status. Carry out the regulated connections. S8JX Switching the AC Input Voltage between 100 and 200 VAC S8JX-G Series 150-W, 5-V Models Fan Replacement S8JX-G Series 300-W 5V, 12V/600-W Model The service life of the fan is approximately 50,000 hours (at 25C). The service life varies, however, depending on the ambient temperature or other surrounding environmental conditions such as dust. As a preventive maintenance measure, replace the fan within approx. two years if it is used at an ambient temperature of 40C. Purchase the S82Y-JX FAN Replacement Fan (sold separately) to replace the fan. S8JX-G The input voltage can be switched between 100 V and 200 V by using the input voltage switch. Make the setting shown in the following figure for the voltage that will be used. (The input voltage is factoryset to 200 V.) "115V": 100 to 120 VAC The input voltage switch is at the back on the bottom of the Power Supply. Fan Set: Fan (above), instruction sheet "230V": 200 to 240 VAC Replace the fan as shown in the following illustration. S8JX-P S8JX-G Series 300-/600-W Models The input voltage can be switched between 100 and 200 V by shorting or opening the input voltage selection terminals. Set the required voltage as shown below. (The voltage is factory-set to 200 V.) 100-V input 200-V input L N N VOLTAGE SELECT SHORT 100-120V OPEN 200-230V VOLTAGE SELECT SHORT 100-120V OPEN 200-230V SHORT BAR SHORT BAR Short with the short bar. Remove the short bar and leave the terminals open. Note: A 300-W model is shown above. S8JX-P Series 300-/600-W Models * Please contact your OMRON sales representative regarding fan replacement. Fans will be replaced at cost. In addition, a replacement fan unit (Model S82Y-JXP@@FAN) is available. Please use the curve below as a guideline for the timing of fan replacement. * Fan replacements made by the customer fall outside the scope of safety standards. Replacement should be implemented as shown below. Common Precautions L ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 59 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 (c) OMRON Corporation 2009-2016 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_19_2_0318 Cat. No. T041-E1-08 0316 (1111)