GU 1 Form A High Capacity (AQY212GH) VDE 4-pin high capacity of 1.1A, I/O isolation voltage of 5,000V 4.78 .188 6.4 .252 3.2 .126 4.78 .188 6.4 .252 2.9 .114 mm inch (Height includes standoff) 1 4 2 3 GU 1 Form A High Capacity (AQY212GH) FEATURES TYPICAL APPLICATIONS 1. Greatly increased capacity Continuous load current: 1.1A 2. Reinforced insulation I/O isolation voltage: 5,000 V AC 3. Compact 4-pin DIP type 4. The improved performance relative to mercury or mechanical relays * Measuring instruments * Security and disaster-preventing system: use in I/O for alarm and security devices, etc. RoHS compliant TYPES Output rating* AC/DC dual use Load voltage Load current 60 V 1.1 A Part No. Surface-mount terminal Through hole terminal Tape and reel packing style Picked from the Picked from the 1/2-pin side 3/4-pin side Tube packing style AQY212GH Packing quantity AQY212GHA AQY212GHAX AQY212GHAZ Tube Tape and reel 1 tube contains 100 pcs. 1 batch contains 1,000 pcs. 1,000 pcs. *Indicate the peak AC and DC values. Note: For space reasons, the three initial letters of the part number "AQY", the surface mount terminal shape indicator "A" and the packing style indicator "X" or "Z" are not marked on the device. RATING 1. Absolute maximum ratings (Ambient temperature: 25C 77F) Item LED forward current LED reverse voltage Peak forward current Power dissipation Load voltage (peak AC) Continuous load current Peak load current Power dissipation Input Output Total power dissipation I/O isolation voltage Temperature limits Operating Storage Panasonic Corporation Symbol IF VR IFP Pin VL IL Ipeak Pout PT Viso Topr Tstg AQY212GH(A) 50 mA 5V 1A 75 mW 60 V 1.1 A 3.0 A 500 mW 550 mW 5,000 V AC -40C to +85C -40F to +185F -40C to +100C -40F to +212F Automation Controls Business Unit Remarks f = 100 Hz, Duty factor = 0.1% Peak AC, DC 100ms (1 shot), VL = DC Non-condensing at low temperatures industrial.panasonic.com/ac/e ASCTB132E 201201-T GU 1 Form A High Capacity (AQY212GH) 2. Electrical characteristics (Ambient temperature: 25C 77F) Item Symbol Typical Maximum Minimum Typical Typical Maximum LED operate current Input LED turn off current LED dropout voltage AQY212GH(A) 1.1 mA 3 mA 0.3 mA 1.0 mA 1.32 V (1.14 V at IF = 5 mA) 1.5 V IFon IFoff VF Ron Off state leakage current Maximum IF = 50 mA IF = 5 mA IL = Max. Within 1 s on time IF = 0 mA VL = Max. IF = 5 mA IL = 100 mA VL = 10 V IF = 5 mA IL = 100 mA VL = 10 V 1 A ILeak 1.3 ms Typical Turn on time* Transfer characteristics IL = 100mA 0.7 Maximum Output IL = 100mA 0.34 Typical On resistance Condition Ton Maximum 5.0 ms Typical 0.1 ms Turn off time* Toff Maximum 0.5 ms Typical I/O capacitance Initial I/O isolation resistance 0.8 pF Ciso Maximum Minimum f = 1 MHz VB = 0 V 1.5 pF 1,000 M Riso 500 V DC *Turn on/Turn off time Input 90% Output 10% Ton Toff RECOMMENDED OPERATING CONDITIONS Please obey the following conditions to ensure proper device operation and resetting. Item Input LED current Symbol IF Recommended value Unit 5 to 10 mA For Dimensions. For Schematic and Wiring Diagrams. For Cautions for Use. These products are not designed for automotive use. If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation technical representative. For more information. REFERENCE DATA 1. Load current vs. ambient temperature characteristics 2. On resistance vs. ambient temperature characteristics 3. Turn on time vs. ambient temperature characteristics Allowable ambient temperature: -40C to +85C -40F to +185F Measured portion: between terminals 3 and 4; LED current: 5 mA; Load voltage: Max. (DC) Continuous load current: Max.(DC) LED current: 5 mA; Load voltage: 10 V (DC); Continuous load current: 100 mA (DC) 1.0 1 5 0.8 4 Turn on time, ms On resistance, Load current, A 1.5 0.6 0.4 3 2 0.5 1 0.2 0 -40 -20 0 20 40 60 80 85 100 0 Ambient temperature, C ASCTB132E 201201-T Panasonic Corporation -40 -20 80 85 0 20 40 60 Ambient temperature, C Automation Controls Business Unit 0 -40 -20 0 20 40 60 Ambient temperature, C industrial.panasonic.com/ac/e 80 85 GU 1 Form A High Capacity (AQY212GH) 4. Turn off time vs. ambient temperature characteristics 5. LED operate current vs. ambient temperature characteristics 6. LED turn off current vs. ambient temperature characteristics LED current: 5 mA; Load voltage: 10 V (DC); Continuous load current: 100 mA (DC) Load voltage: 10 V (DC); Continuous load current: 100mA (DC) Load voltage: 10 V (DC); Continuous load current: 100mA (DC) 0.8 0.6 0.4 0.2 5 LED turn off current, mA 5 LED operate current, mA Turn off time, ms 1 4 3 2 1 0 -40 -20 0 20 40 60 3 2 1 0 80 85 4 -40 -20 Ambient temperature, C 0 20 40 60 0 80 85 -40 -20 Ambient temperature, C 0 20 40 60 80 85 Ambient temperature, C 7. LED dropout voltage vs. ambient temperature characteristics 8. Current vs. voltage characteristics of output at MOS portion 9. Off state leakage current vs. load voltage characteristics LED current: 5 to 50 mA Measured portion: between terminals 3 and 4; Ambient temperature: 25C 77F Measured portion: between terminals 3 and 4; Ambient temperature: 25C 77F 1.4 2 1 1.3 -1 50mA 1.2 -0.5 0.5 Voltage, V 30mA 20mA -1 10mA 1.1 -40 -20 0 20 40 60 10-4 10-6 10-8 10-10 -2 5mA 1 1 Off state leakage current, A 3 Current, A LED dropout voltage, V 1.5 -3 80 85 10-120 10 20 Ambient temperature, C 30 40 50 60 Load voltage, V 11. Turn off time vs. LED forward current characteristics 12. Output capacitance vs. applied voltage characteristics Measured portion: between terminals 3 and 4; Load voltage: 10 V (DC); Continuous load current: 100 mA (DC); Ambient temperature: 25C 77F Measured portion: between terminals 3 and 4; Load voltage: 10 V (DC); Continuous load current: 100 mA (DC); Ambient temperature: 25C 77F Measured portion: between terminals 3 and 4; Frequency: 1 MHz; Ambient temperature: 25C 77F 0.5 4 0.4 3 2 800 Output capacitance, pF 5 Turn off time, ms Turn on time, ms 10. Turn on time vs. LED forward current characteristics 0.3 0.2 1 0.1 0 0 700 600 500 400 300 200 100 0 10 20 30 40 LED forward current, mA Panasonic Corporation 50 0 10 20 30 40 50 0 0 10 LED forward current, mA Automation Controls Business Unit industrial.panasonic.com/ac/e 20 30 40 50 60 Applied voltage, V ASCTB132E 201201-T