2
Current in A
Characteristics
6
Environment
Conformity to standards EN/IEC 60947-5-1
EN/IEC 60204-32, UL 508, CSA C22-2 n° 14
EN/IEC 60947-5-5 and EN/ISO 13850 for versions with trigger action Emergency stop
Product certifi cations UL type 4X A600-Q600, CSA type 4 A600-Q600
Protective treatment Standard version “TH”
Ambient air temperature For operation °C - 25…+ 70
For storage °C - 40…+ 70
Vibration resistance 15 gn (10…500 Hz) conforming to IEC 60068-2-6
Shock resistance 100 gn conforming to IEC 60068-2-27
Electric shock protection Class II conforming to IEC 61 140
Degree of protection IP 65 conforming to IEC 60529
IK 08 conforming to EN 50102
Mechanical durability
(in millions of operating cycles) 1
Enclosure Double insulated polypropylene, coloured yellow throughout
Cable entry Rubber sleeve with stepped entry diameter for cable Ø 7…Ø 15 mm
Contact block characteristics
Rated operational characteristics a AC-15: A600 or Ue = 600 V, le = 1.2 A or Ue = 240 V, Ie = 3 A
c DC-13: Q600 or Ue = 600 V, le = 0.1 A or Ue = 250 V, Ie = 0.27 A
conforming to EN/IEC 60947-5-1 Appendix A
Thermal current (lthe) A10
Rated insulation voltage (Ui) V600, degree of pollution 3, conforming to IEC 60947-1
Rated impulse withstand voltage (U imp) kV 6, conforming to IEC 60947-1
Positive operation Mushroom head pushbutton: N/C contact with positive opening operation conforming
to EN/IEC 60947-5-1 Appendix K
Contact operation Slow break
Resistance across terminals MΩy 25
Operating force
N
13 to 15
T erminal referencing By numbers conforming to CENELEC EN 50013
Short-circuit protection 10 A cartridge fuse type gG (gl)
Connection mm2Screw and captive cable clamp terminals.
Clamping capacity: 1 x 2.5 or 2 x 1.5 with or without cable end
Rated operational power Conforming to EN/IEC 60947-5-1 Appendix C. Utilisation categories AC-15 and DC-13.
Operating rate: 3600 operating cycles/hour . Load factor: 0.5.
a.c. supply a 50/60 Hz
o Inductive circuit d.c. supply c
Power broken in W for 1 million operating cycles
Voltage V 24 48 120
o W654840
,1
,2
,4
,6
1
230 V 127 V 24...48 V
Ithe
Millions of operating cycles
,1
,2
,4
,6
1
230 V 127 V 24...48 V
Ithe
Millions of operating cycles
References:
page 30072/3 Dimensions:
page 30072/5 Application schemes:
page 30072/5
References:
page 30072/3 Dimensions:
page 30072/5 Application schemes:
page 30072/5
References:
page 30072/3 Dimensions:
page 30072/5 Application schemes:
page 30072/5
References:
page 30072/3 Dimensions:
page 30072/5 Application schemes:
page 30072/5
Pendant control stations 6
Double insulated with intuitive operation,
type XAC A “Pistol grip”
For control circuits
30072-EN_Ver6.3.indd