Characteristics
Note. The data given above are initial values.
*1. The values for dielectric strength shown are for models with a Separator (refer to "Micro Switch
Common Accessories").
*2. The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel
Position value for lever.
Close or open circuit of the contact is 1ms max.
*3. For testing conditions, consult your OMRON sales representative.
Item Model D2S-10 models D2S-5 models D2S-01 models
Permissible operating speed 0.1 mm to 1 m/s (for pin plunger models)
Permissible
operating
frequency
Mechanical 400 operations/min
Electrical 60 operations/min
Insulation resistance 100 M
Ω
min. (at 500 VDC with insulation tester)
Contact resistance
(initial value)
OF 1.47 N models 30m
Ω
max. 50 m
Ω
max.
OF 0.49 N models - 50 m
Ω
max. 100 m
Ω
max.
Dielectric
strength * 1
Between terminals of the same
polarity 1,000 VAC 50/60 Hz 1 min
Between current-carrying metal
parts and ground 1,500 VAC 50/60 Hz 1 min
Between each terminals and
non-current-carrying metal parts 1,500 VAC 50/60 Hz 1 min
Vibration
resistance * 2 Malfunction 10 to 55 Hz, 1.5 mm double amplitude
Shock
resistance
Durability OF 1.47 N models 1,000 m/s
2
{approx. 100G} max.
OF 0.49 N models 500 m/s
2
{approx. 50G} max.
Malfunction * 2 OF 1.47 N models 300 m/s
2
{approx. 30G} max.
OF 0.49 models 200 m/s
2
{approx. 20G} max.
Durability * 3
Mechanical 10,000,000 operations min.
(60 operations/min)
30,000,000 operations min.
(60 operations/min)
Electrical 50,000 operations min.
(30 operations/min)
200,000 operations min.
(30 operations/min)
Degree of protection IEC IP40
Ambient operating temperature -25°C to
+
85°C (at ambient humidity of 60% max.)
(with no icing or condensation)
Ambient operating humidity 85% max. (for
+
5°C to
+
35°C)
Weight Approx. 1.6 g (pin plunger models)
Ratings
Note. The above rating values apply under the
following test conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 30 operations/min
Approved Safety
Standards
The items shown in the "List of Models"
are not standard approved models.
Consult your OMRON sales
representative for specific models with
standard approvals.
UL (
UL1054)
/CSA
(CSA C22.2 No.55)
Model
Item
Rated voltage Resistive load
D2S-10
models 250 VAC 10.1 A
D2S-5
models
125 VAC
250 VAC
5 A
3 A
D2S-01
models
125 VAC 0.1 A
30 VDC 0.1 A
Rated
voltage
Model
D2S-10 D2S-5 D2S-01
125 VAC
250 V
-
10.1 A
5 A
3 A
0.1 A
-
30 VDC - - 0.1 A