Varistor Products
©2010 Littelfuse, Inc.
Revision: June 28, 2010
0201 MLA Varistor Series
Surface Mount Multilayer Varistors (MLVs) > 0201 MLA Series
Specifications are subject to change without notice.
Please refer to www.littelfuse.com/series/0201MLA.html for current information.
T
1
T
2
100
50
0
O1TIME
PERCENT OF PEAK VALUE
T
Peak Pulse Current Test Waveform for Clamping Voltage
01 = Virtual Origin of Wave
T = Time from 10% to 90% of Peak
T1 = Rise Time = 1.25 x T
T2 = Decay Time
Example - For an 8/20 μs Current Waveform:
8μs = T1 = Rise Time
20μs = T2 = Decay Time
Reliability and Environmental Specifications
Judge Criteria Test Condition
Solderability > 95% solder coverage 245 +/- ºC, 3 +/- 1 sec.
Leaching Resistance > 95% solder coverage 245 +/- ºC, 3 +/- 1 sec.
High Temperature Exposure Δ Vv / Vv < 10% 1000 hours 85ºC, un-powered
Thermal Shock Δ Vv / Vv < 10% -45 to +85 ºC, 30 min. cycle, 5 cycles
Operating Life Δ Vv / Vv < 10% 85 ºC, DC working voltage 1000 hours
Bias Humidity Δ Vv / Vv < 10% 40 ºC / 85% RH, DC working voltage 1000 hours
Multilayer Internal Construction
GRAINS
DEPLETION
FIRED CERAMIC
DIELECTRIC
REGION
METAL
ELECTRODES
DEPLETION
REGION
METAL END
TERMINATION
To avoid the possibility of generating stresses due to
thermal shock, a preheat stage in the soldering process
is recommended, and the peak temperature of the solder
process should be rigidly controlled.
When using a reflow process, care should be taken to
ensure that the ML chip is not subjected to a thermal
gradient steeper than 4 degrees per second; the ideal
gradient being 2 degrees per second. During the soldering
process, preheating to within 100 degrees of the solder's
peak temperature is essential to minimize thermal shock.
Once the soldering process has been completed, it is
still necessary to ensure that any further thermal shocks
are avoided. One possible cause of thermal shock is hot
printed circuit boards being removed from the solder
process and subjected to cleaning solvents at room
temperature. The boards must be allowed to cool gradually
to less than 50º C before cleaning.
Lead–free (Pb-free) Soldering Recommendations
MAXIMUM TEMPERATURE 260˚C,
TIME WITHIN 5˚C OF PEAK
20 SECONDS MAXIMUM
PREHEAT ZONE
RAMP RATE
<3˚C/s 60 - 150 SEC
> 217˚C
TEMPERATURE °C
TIME (MINUTES)
300
250
200
150
100
50
00 1.0 2.0 3.0 4.0 5.0 6.0 7.0