294
Amphenol Corporation Tel: 800-627-7100 www.amphenolrf.com
Assembly Instructions-C20 Amphenol®
HN - Typical Clamp
Cut end of cable even. Push nut, washer and gasket over cable jacket.
Remove vinyl jacket .798" (20.3) from end of cable. For double shield
cables, remove vinyl jacket 1 3/16" (30.2) from end of cable.
Push clamp over copper braid, flush against cable jacket. Cut
exposed copper braid so that approximately .219" (5.6) remains and
fan over clamp. Trim braid even with end of taper. Cut cable dielectric
to Dim c.
Solder contact pin to conductor. Do not overheat dielectric. Do not
use excess solder. W ipe clean; see that dielectric is free from solder,
resin and foreign material.
Taper dielectric with AMPHENOL 103-301 (MX-103/U) trimming tool.
When tapering dielectric of cable for plug assembly, push contact stop
of tool to bottom of slot. Tool will stop cutting when shoulder of con-
tact butts against stop. Cable will be properly tapered when end of
center contact is flush with end of trimmer body.
Apply small amount of Dow Corning DC-4 Silicone Compound or
equivalent (per MIL-S-8660) on tapered surface of dielectric. Insert
assembly into connector body. T ighten nut securely with wrench.
Nut Washer Gasket Clamp Male
Contact Plug Body Female
Contact Jack Body
a
bc
Stripping dims. inches (millimeters)
Amphenol
Part # a b c
82-38 1.0 (25.4) .781 (19.8) .219 (5.6)